DAIKIN BRC1H82W Madoka Wired Remote Controller User Manual
- June 5, 2024
- Daikin
Table of Contents
- DAIKIN BRC1H82W Madoka Wired Remote Controller
- General safety precautions
- About this document
- Remote controller: Overview
- Operation
- Date and time
- Maintenance and service
- Troubleshooting
- About the box
- Preparation
- Installation
- Starting up the system
- Maintenance
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
DAIKIN BRC1H82W Madoka Wired Remote Controller
General safety precautions
Please read these general safety precautions carefully before installing air
conditioning equipment, and be sure to install the equipment correctly.
Failure to follow these instructions properly may result in property damage or
personal injury, which may be serious depending on the circumstances.
For the user
WARNING
To clean the controller, do NOT use organic solvents, such as paint thinner.
WARNING
Do NOT use flammable materials (e.g. hairspray or insecticide) near the
controller.
WARNING
To prevent electric shocks or fire:
- Do NOT operate the controller with wet hands.
- Do NOT disassemble the controller and touch interior parts. Contact your dealer.
- Do NOT modify or repair the controller. Contact your dealer.
- Do NOT relocate or reinstall the controller by yourself. Contact your dealer.
WARNING
Do NOT play with the unit or its remote controller. Accidental operation by a
child may result in impairment of bodily functions and harm health.
For the installer
The precautions described in this document cover very important topics, follow
them carefully.
INFORMATION
This controller is an option and cannot be used standalone. Also see the
installation and operation manual of the indoor and outdoor units.
WARNING
Improper installation or attachment of equipment or accessories could result
in electrical shock, short-circuit, leaks, fire or other damage to the
equipment. ONLY use accessories, optional equipment and spare parts made or
approved by Daikin.
WARNING
All field wiring and components MUST be installed by a licensed electrician
and MUST comply with the applicable legislation.
NOTICE
The remote controller MUST be mounted indoors.
NOTICE
When the controller is used as room thermostat, select an installation
location where the average temperature in the room can be detected.
Do NOT install the controller in the following places:
- In places where it is exposed to direct sunlight.
- In places where it is near a heat source.
- In places that are affected by outside air or air draught due to e.g. door opening/closing.
- In places where the display can easily get dirty.
- In places where there is NO easy access to the controls.
- In places with temperatures <–10°C and >50°C.
- In places where the relative humidity is >95%.
- In places where there is machinery that emits electromagnetic waves. Electromagnetic waves may disturb the control system, and cause malfunction of the equipment.
- In places where it may be exposed to water, or in generally moist areas.
If you are NOT sure how to install or operate the unit, contact your dealer.
After finishing installation:
- Conduct a trial operation to check for faults.
- Explain the user how to operate the controller.
- Ask the user to store the manual for future reference.
INFORMATION
Consult your dealer regarding the relocation and reinstallation of the
controller.
About this document
Target audience
Authorised installers + end users
Documentation set
This document is part of a documentation set. The complete set consists of:
- Installation and operation manual:
- Installation instructions
- Basic operation instructions
- Installer and user reference guide:
- Extended installation and operation information
- Declaration of conformity:
INFORMATION: Declaration of conformity
Hereby, Daikin Europe N.V. declares that the radio equipment type BRC1H is in
compliance with the Directive 2014/53/EU. The original declaration of
conformity is available from the BRC1H product pages.
The documentation set is available from the BRC1H product pages:
-
BRC1H82W: https://qr.daikin.eu/?N=BRC1H82W
-
BRC1H82K: https://qr.daikin.eu/?N=BRC1H82K
-
BRC1H82S: https://qr.daikin.eu/?N=BRC1H82S
Latest revisions of the supplied documentation may be available on the
regional Daikin website or via your dealer.
The original documentation is written in English. All other languages are
translations.
Remote controller: Overview
About the controller
Depending on configuration, the controller is operable in either one of three modes. Each mode offers different controller functionality.
Mode | Functionality |
---|---|
Normal | The controller is fully functional. |
All functionality described under “4 Operation” ►[ 5] is available.
The controller can be a master or a slave controller.
Alarm only| The controller only acts as leak detection alarm for a single indoor unit.
No functionality described under “4 Operation” ►[ 5] is available.
For information on the leak detection alarm, see “6.2 Refrigerant leak
detection” ►[ 8].
The controller can be a master or a slave controller.
Supervisor| The controller only acts as leak detection alarm for the whole
system, i.e. multiple indoor units and their respective controllers.
This mode is intended for a controller that is to be used in a supervision
location, e.g. the reception desk of a hotel.
No functionality described under “4 Operation” ►[ 5] is available.For
information on the leak detection alarm, see “6.2 Refrigerant leak
detection” ►[ 8].
The controller can only be a slave controller.
Buttons
- a. ON/OFF
- When OFF, press to turn ON the system.
- When ON, press to turn OFF the system.
- ENTER/ACTIVATE /SET
- From the home screen, enter the main menu.
- From the main menu, enter one of the submenus.
- From their respective submenu, activate an operation/ventilation mode.
- In one of the submenus, confirm a setting.
- CYCLE/ADJUST
- Cycle left.
- Adjust a setting (default: decrease).
- CYCLE/ADJUST
- Cycle right.
- Adjust a setting (default: increase).
Status icons
Icon | Description |
---|
| System operation ON. Indicates that
the system is in operation.
**| System operation OFF. Indicates that the system is NOT in
operation.
| Bluetooth.(1) Indicates that the
controller is communicating with a mobile device, for use with the Madoka
Assistant app.
| Lock. Indicates that a function or
operation mode is locked and therefore cannot be used or selected.
| Centralized control. Indicates
that the system is controlled by central control equipment (optional
accessory) and that control of the system by the controller is limited.
| Changeover under centralized control.
Indicates that the cooling/heating changeover is under centralized control by
another indoor unit, or by an optional cool/ heat selector that is connected
to the outdoor unit.
| Defrost/Hot start. Indicates that the
defrost/hot start mode is active.
Icon| Description
---|---
| Schedule/Timer. Indicates that the
system operates according to a schedule, or that the OFF timer is enabled.
| Time not set. Indicates that controller’s time is not set.
| Self-cleaning filter operation.
Indicates that self- cleaning filter operation is active.
| Quick Start. Indicates that Quick Start
mode is active (Sky Air only).
| Test operation. Indicates that Test
Operation mode is active (Sky Air only).
| Inspection. Indicates that the indoor or outdoor unit is being
inspected.
| Periodic inspection. Indicates that the
indoor or outdoor unit is being inspected.
| Backup. Indicates that in the system an indoor unit is set as backup
indoor unit.
| Individual airflow direction. Indicates
that the individual airflow direction setting is enabled.
| Information. Indicates that the system
has a message to convey. To see the message, go to the information screen.
| Warning. Indicates that an error
occurred, or that an indoor unit component needs to be maintained.
| Power consumption limit. Indicates that the system’s power consumption
is being limited, and that it is running with restricted capacity.
| End of power consumption limit.
Indicates that the system’s power consumption is no longer being limited, and
that it is no longer running with restricted capacity.
| Rotation. Indicates that Rotation mode
is active.
| Setback. Indicates that the indoor unit is operating under setback
conditions.
| Ventilation**. Indicates that a heat reclaim ventilation unit is
connected.
INFORMATION
- For information on the operation mode and ventilation mode icons, see “4.2 Operation mode” [4 6] and “4.6.1 Ventilation mode” [4 7] respectively.
- Most icons are related to things set in the Madoka Assistant app. For more information, see the app, and the installer and user reference guide.
Status indicator
a. Status indicator
INFORMATION
For a full description of the behaviour of the status indicator, see the
installer and user reference guide.
Operation
Basic usage
Home screen
Depending on configuration, the controller either has a standard or a detailed
home screen. In most cases, the standard home screen gives you only the active
operation mode, messages (if any), and the setpoint temperature (in case of
Cooling, Heating, or Auto operation mode).The detailed home screen gives you
all kinds of information through status icons.
- a Messages
- b Active operation mode
- c Setpoint temperature
INFORMATION
The controller is equipped with a power saving function that causes the screen
to go blank after a period of inactivity. To make the screen light up again,
press one of the buttons.
Main menu
From the home screen, press to enter the main menu. Use – and + to cycle
through the menus. Press again to enter one of the menus.
Operation mode
The indoor unit can operate in various operation modes.
To set the operation mode
-
Navigate to the operation mode menu.
-
Use – and + to select an operation mode.
-
Press O to activate.
Result: The indoor unit changes its operation mode and the controller returns to the home screen.
Setpoint
The setpoint is the target temperature for the Cooling, Heating, and Auto operation modes.
INFORMATION
The lower setpoint limit of the Cooling operation mode is 20°C, as per UAE
Federal regulation UAE.S 5010-5:2016 clause 6, and UAE.S 5010-1:2016 clause
10.
To set the setpoint
Prerequisite: The active operation mode is either ‘Cooling’, ‘Heating’, or
‘Auto’.
- In the home screen, use – and + to adjust the setpoint.
Result: The indoor unit changes its temperature setpoint.
Date and time
Set the date and time for the indoor units connected to the controller.
To set date and time
-
Navigate to the date and time menu.
-
Press + to activate editing.
Result: The fields become editable.
- Set the date and time. Set with – and +. Confirm with O. Cycle through the menu until all fields are set correctly.
Result: You set the date and the time.
INFORMATION
Confirming the value in a field will automatically bring you to the next
field. To finish making settings and leave the menu, navigate to and confirm
the value in the last field.
Airflow
Airflow direction
The airflow direction is the direction in which the indoor unit blows its air.
INFORMATION
For more information, see the installer and user reference guide.
To set the airflow direction
-
Navigate to the airflow direction menu.
-
Use – and + to adjust the airflow direction.
-
Press to confirm.
Result: The indoor unit changes its airflow direction and the controller returns to the home screen.
Fan speed
The fan speed is the strength of the airflow coming out of the indoor unit.
To set the fan speed
-
Navigate to the fan speed menu.
-
Use – and + to adjust the fan speed.
-
Press to confirm.
Result: The indoor unit changes its fan speed and the controller returns to the home screen.
Ventilation
INFORMATION
Ventilation settings can ONLY be made for heat reclaim ventilation units.
Ventilation mode
The heat reclaim ventilation unit can operate in various operation modes.
To set the ventilation mode
-
Navigate to the ventilation mode menu.
-
Use – and + to select a ventilation mode.
-
Press to activate.
Result: The heat reclaim ventilation unit changes its operation mode and the controller returns to the home screen.
Ventilation rate
The ventilation rate is the fan speed during ventilation operation.
To set the ventilation rate
-
Navigate to the ventilation rate menu.
-
Use – and + to adjust the ventilation rate.
-
Press to confirm.
Result: The heat reclaim ventilation unit changes its ventilation rate and the controller returns to the home screen.
Advanced usage
The controller only allows for basic operation. For advanced operation, use the Madoka Assistant app.
Maintenance and service
Overview: Maintenance and service
When a system components needs maintenance or service, consult your dealer. To
indicate that maintenance is due, the controller displays ! on the home
screen, and/or displays a warning screen as soon as you press O to enter the
main menu from the home screen.
The following warning screens are related to indoor unit maintenance:
Troubleshooting
Overview: Troubleshooting
When the system is in error, consult your dealer. To indicate system error, the controller displays on the home screen, and/or displays an error screen as soon as you press O to enter the main menu from the home screen.
INFORMATION
If the controller is set to be operable in “Supervisor” mode, then the
controller adds the “supervised room address” of the faulty indoor unit to the
error screen. In “Supervisor” mode, it is mandatory to set a unique
“supervised room address” for every indoor unit. The “supervised room address”
can be set in the Madoka Assistant app. Note that in case of multiple
leakages, only the address of the first faulty unit rising the error is
displayed.
For more information about the modes the controller can be set to be operable.
Refrigerant leak detection
When the system detects a refrigerant leak, an alarm goes off. Stop the alarm and consult your dealer.
INFORMATION
- It is possible to stop the leak detection alarm from the controller and from the app. For more information about the app, see the installer and user reference guide.
- Depending on the mode the controller is set to be operable in, the refrigerant leak detection screen can have more or less information. For more information, see the installer and user reference guide.
To stop the leak detection alarm
-
Press + for 3 seconds to stop the alarm
Result: The alarm stops. -
Consult your dealer.
INFORMATION
In case the controller is set to be operable in ‘Supervisor’ mode, the
controller will indicate the supervised room address of the indoor unit for
which the leak detection alarm occurs. However, it is not possible to stop the
alarm of the indoor unit controller (set to be operable in either “Normal” or
“Alarm only” mode) from the controller in “Supervisor” mode. The alarm of the
controller connected to the indoor unit with the leak has to be stopped
individually.
About the box
To unpack the controller
-
Open the box.
-
Separate the accessories.
- a. Installation and operation manual
- b. Wood screws + wall plugs
Preparation
Wiring requirements
All wiring must comply with the following requirements:
Wire specification | Value |
---|---|
Type | Sheathed vinyl cord or cable (2 wires) |
Section | 0.75~1.25 mm2 |
Maximum length | 500 m |
Installation
NOTICE
During the installation of the controller, keep the installation environment
dust-free in order to avoid any particles entering the PCB side of the
controller.
Mounting the controller
Before you can mount the controller, you have to determine the wiring routing,
and accordingly, remove a piece of the controller’s rear casing.
The wiring can be routed from the top, the rear, the left, or the bottom.
Remove a piece of the rear casing according to the illustration:
- a Wiring from the top
- b Wiring from the left
- c Wiring from the bottom
In case you are routing the wiring from the rear, you do not have to remove anything.
To mount the controller
- Take the screws and plugs from the accessory bag.
- Mount the rear casing to a flat surface.
INFORMATION
If required (e.g. when mounting to a flush-mounted electrical installation
box), mount the rear casing by way of the knockout holes.
NOTICE
When mounting the rear casing to a flush-mounted electrical installation box
inside a wall, make sure that that wall is completely flat.
Connecting the electrical wiring
To connect the electrical wiring
Connect controller terminals P1/P2 to indoor unit terminals P1/P2.
From the top
From the rear
From the left
From the bottom
Closing the controller
To close the controller
-
1. Click the front of the controller into the rear casing.
Starting up the system
The controller gets its power from the indoor unit. It will start up as soon
as it is connected. For the controller to be operable, make sure the indoor
unit is powered on.
Once the controller is powered, it will automatically start up. If it is the
first and only controller that is connected to the indoor unit, it will
automatically get designated as a “Normal” master controller.
INFORMATION
For more information on how to designate the controller to be of a different
type (i.e. operable in “Normal”, “Alarm only”, or “Supervisor” mode, as master
controller or as slave controller), see the installer and user reference
guide.
Maintenance
Maintenance safety precaution
WARNING
Before carrying out any maintenance or repair activities, stop system
operation with the controller, and turn off the power supply circuit breaker.
Possible consequence: electrical shock or injury.
NOTICE
To clean the controller, do NOT use organic solvents, such as paint thinner.
Possible consequence: damage, electrical shock, or fire.
INFORMATION
When the dirt on the surface cannot be removed easily while cleaning the
controller, soak the cloth in neutral detergent diluted with water, squeeze
the cloth tightly, and clean the surface. Afterwards, wipe dry with a dry
cloth.
To clean the controller
- Wipe the screen and other surface parts of the controller with a dry cloth.
Time to clean filter indication
When the indoor unit filter is dirty and needs to be cleaned, the
controller will indicate this by displaying in the top left corner of the home
screen, and confronting you with the ‘Time to clean filter’ screen as soon as
you try to enter the main menu from the home screen.
To remove the Time to clean filter indication
Prerequisite: On trying to enter the main menu from the home screen, you are
confronted with the ‘Time to clean filter’ screen.
- Clean the filter.
- Press + to remove the ‘Time to clean filter’ indication.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>