LINOVISION S500SD LoRaWAN Wireless WorkSpace Sensor User Guide

June 3, 2024
LINOVISION

S500SD LoRaWAN Wireless WorkSpace Sensor
User Guide

Safety Precautions

Linovison will not shoulder responsibility for any loss or damage resulting from not following the instructions of this operating guide.

  • The device must not be disassembled or remodeled in any way.
  • To avoid the risk of fire and electric shock, do keep the product away from rain and moisture before installation.
  • Do not place the device where the temperature is below/above the operating range.
  • Do not touch components that may be hot.
  • The device must never be subjected to shocks or impacts.
  • Make sure the device is firmly fixed when installing.
  • Make sure the plug is firmly inserted into the power socket.
  • Do not expose the device to where laser beam equipment is used.
  • Use a soft, dry cloth to clean the lens of the device. Stubborn stains can be removed using a cloth dampened with a small quantity of detergent solution, then wipe them dry.

Declaration of Conformity
S500SD is in conformity with the essential requirements and other relevant provisions of the CE, FCC, and RoHS.LINOVISION S500SD LoRaWAN Wireless
WorkSpace Sensor - Declaration of Conformity Icon

Copyright © 2007-2021 Linovision. All rights reserved.
All information in this guide is protected by copyright law. Whereby, no organization or individual shall copy or reproduce the whole or part of this user guide by any means without written authorization from Hangzhou Linovision Co., Ltd.
Revision History

Date Doc Version Description
Apr. 26, 2021 V 1.0 Initial version

Product Introduction

1.1 Overview
S500SD, based on Artificial Intelligence (AI) technology, is an AI workplace sensor designed to monitor occupancy & utilization in modern workspaces, which can reach up to 95% recognition rate. With the ability to sense from up to 78m², fewer sensors are needed to cover the same area, decreasing the deployment costs for users. Only counter values are transmitted over the LoRaWAN®  network to prevent privacy concerns. S500SD is equipped with Wi-Fi for easy configuration without any tools.
Sensor data are transmitted in real-time using standard LoRaWAN®  protocol. LoRaWAN® enables encrypted radio transmissions over long distances while consuming very little power. The user can obtain sensor data and view the trend of data change through the user’s own network server.
1.2 Key Features

  • The recognition rate is up to 95% based on advanced AI identification and analysis
    technology and wide detection range

  • Support to map up to 12 custom regions

  • No image data is collected, free from privacy concerns

  • Equipped with Wi-Fi for web GUI configuration

  • Function well with standard LoRaWAN® gateways and network servers

Hardware Introduction

2.1 Packing List

LINOVISION S500SD LoRaWAN Wireless WorkSpace Sensor - Packing
List|
---|---
1 × S500SD Sensor| Wall Mounting Kits| 1 × Type-C Cable (1 m) & Power Adapter| 1 × Mounting Sticker| 1 × Quick Guide

If any of the above items are missing or damaged, please contact your sales representative.
2.2 Hardware Overview

LINOVISION S500SD LoRaWAN Wireless WorkSpace Sensor - Hardware
Overview 2.3 Buttons and LED Indicators

Function Action ED Indication
Turn On/Off Wi-Fi Press and hold the Wi-Fi button for more than 3 seconds.

Off → On
Press and hold the Wi-Fi button for more than 3 seconds.| On → Off
Reset to Factory Default| Press and hold the reset button for more than 10 seconds.| Blinks 6 times.

2.4 Dimensions(mm)

LINOVISION S500SD LoRaWAN Wireless WorkSpace Sensor -
Dimensions

Access the Sensor

S500SD sensor provides a user-friendly web GUI for configuration and users can access it via a Wi-Fi connection. The recommended browsers are Internet Explorer, Firefox, Chrome, Microsoft Edge, and Safari. The default IP of the sensor is 192.168.1.1, and the default SSID is Vision Sensor_XXXXXX (which can be found on the label).
3.1 Access without Plugin
Step 1: Power on the device.
Step 2: Enable the Wireless Network Connection on your computer and search for the corresponding access point, then connect the computer to this access point.
Step 3: Open the Browser and type 192.168.1.1 to access the web GUI.
Step 4: Select the language.
Step 5: Users need to set the password when using the sensor for the first time. And three security questions can also be set optionally. After configuration, use a username (admin) and a custom password to log in to the sensor.
Note:

  1. Password must be 8 to 32 characters long and contain at least one number and one letter.
  2. You can click the “forget password” on the login page to reset the password by answering three security questions when you forget the password if you set the security questions in advance.LINOVISION S500SD LoRaWAN Wireless WorkSpace Sensor - Access without PluginLINOVISION S500SD LoRaWAN Wireless WorkSpace Sensor - Access without Plugin 1

3.2 Access with Plugin
For IE browser access, users need to install the MsActiveX first. You can refer to the steps as follows:
Step1: Launch the IE browser and enter the IP address of the sensor;
Step2: Enter the user name and custom password and click “Login”;
Step3: At the first time to log in to the device, the browser will prompt you to install Controls, please click “Click here to download and install controls manually” as shown below;

Note: During installing the controls, please keep the browsers close.
Step4: Follow the prompts to install the Controls, when it`s finished, it will pop out a window as shown below. Please click “Finish” and refresh the browser, then you will see the video.LINOVISION S500SD LoRaWAN Wireless
WorkSpace Sensor - Fig 2

If IE9 or a higher version browser is used, it is suggested that the web link should be added as a trusted site. See the instructions as follows:
Step1: Start the IE9 or higher version browser, and select “Tools”→ “Internet Options”;LINOVISION S500SD LoRaWAN Wireless WorkSpace Sensor - Fig
3

Step2: Select “Security” to “Trusted”;LINOVISION S500SD LoRaWAN
Wireless WorkSpace Sensor - Fig 4

Step3: Enter the IP address of the camera in the blank and click “Add”;LINOVISION S500SD LoRaWAN Wireless WorkSpace Sensor - Fig
5

Step4: Enter the IP address. After logging on to web GUI successfully, the user is allowed to view live video.

Operation Guide

4.1 Live Video
After logging in to the network camera web GUI successfully, the user is allowed to view live video as follows.LINOVISION S500SD LoRaWAN Wireless
WorkSpace Sensor - Live Video

Parameters Description
Image Config Brightness: Adjust the Brightness of the scene

Contrast: Adjust the color and light contrast
Saturation: Adjust the Saturation of the image. Higher Saturation makes colors appear more “pure” while lower one appears more “wash-out”
Sharpness: Adjust the Sharpness of the image. Higher Sharpness sharps the pixel boundary and makes the image looks “clear”
2D DNR/3D DNR: Adjust the noise reduction level
Default: Restore brightness, contrast, and saturation to default settings
| Click to access the configuration page
| People Counting (Region): Show the mapped or non-mapped regions of people counting
Hide Detection Region: hide people detection region
Window size| Click to display images at a window size
Real size| Click to display images at a real size
Full Screen| Click to display images at full-screen
---|---
| Start/Stop live view
Enable Digital Zoom| When enabled, you can zoom in on a specific area of a video image with your mouse wheel

4.2 IoT
4.2.1 People Counting
Users can set the report settings and detection regions here.LINOVISION
S500SD LoRaWAN Wireless WorkSpace Sensor - Fig 7

Parameters Description
Number of People Show the current number of people.
Report Regularly Report the number of people according to reporting interval.

Reporting Interval: 5-3600s
Report by Result| Report according to the following people number results:
• Zero and Non-zero
• Once result in changes
Enable| Enable the detection area customization feature. If disabled, the whole area will be a detection area.
---|---
Detection Area| Select the customized area as either mapped or except mapped area. You can draw the area in the below screen. 12 areas can be set at most.
Mapped Region: Only people in the mapped region will be detected
Non-mapped Region: Only people in except mapped region will be detected
Clear| Clear all areas you draw before

4.2.2 LoRa
LoRa settings are used for configuring the transmission parameters in the LoRaWAN® network.LINOVISION S500SD LoRaWAN Wireless WorkSpace Sensor - Fig
8

Parameters Description
Status LoRaWAN® network status of this device.
Device EUI The unique ID of the device can also be found on the label.
App EUI Default App EUI is 24E124C0002A0001.
Join Type OTAA and ABP modes are available.
Application Key App key for OTAA mode, default is

5572404C696E6B4C6F52613230313823.
---|---
Device Address| Devendra for ABP mode, the default is the 5th to 12th digits of SN.
Network Session Key| Whiskey for ABP mode, default is 5572404C696E6B4C6F52613230313823.
Application Session Key| Appskey for ABP mode, default is 5572404C696E6B4C6F52613230313823.
Confirmed Mode| If the device does not receive an ACK packet from a network server, it will resend data 3 times at most.
ADR Mode| Allow the network server to adjust the data rate of the device.
Rejoin Mode| Reporting interval ≤ 30 mins: the device will send specific mounts of LoRa MAC packets to check connection status every 30 mins; If no reply after specific packets, the device will re-join.
Reporting interval > 30 mins: the device will send specific mounts of LoRaMAC packets to check the connection status every reporting interval; If no reply after specific packets, the device will re-join.
Application Port| The port used for sending and receiving data, the default port is 85.
Spreading Factor| If ADR is disabled, the device will send data via this spreading factor.
LoRaWAN Version| V1.0.2, V1.0.3, and V1.1.0 are available.
Region| The frequency plan of this device.
Channel| Enter the index to select the frequency channel.
Examples:
1, 40: Enabling Channel 1 and Channel 40
1-40: Enabling Channel 1 to Channel 40
1-40, 60: Enabling Channel 1 to Channel 40 and Channel 60 All: Enabling all channels
Null: Indicates that all channels are disabled

Note:

  1. Please contact sales for the device EUI list if there are many units.
  2. Please contact sales if you need random App keys before purchase.
  3. Only OTAA mode supports rejoin mode.
  4. For -868M models, the default frequency is EU868; for the -915M models, the default frequency is AU915.

4.2.3 Wi-Fi

LINOVISION S500SD LoRaWAN Wireless WorkSpace Sensor - Fig
9

Parameters Description
Enabled Enable Wi-Fi feature.
Work Mode Work mode is fixed as AP and can not connect to another access

point.
SSID| The unique name for this sensor is a Wi-Fi access point.
Protocol| 802.11b (2.4G), 802.11g (2.4G), and 802.11n (2.4G) are optional.
Bandwidth| 20MHz or 40MHz are optional.
Channel| Select the wireless channel. Auto, 1,…11 are optional.
Security Mode| No Encryption, WEP Open System, WEP Shared Key, WPA-PSK, WPA2-PSK” and “WPA-PSK/WPA2-PSK are optional.
DHCP Server Settings| LAN IP Address: the IP address that is used to access the web GUI of the sensor.
Subnet mask: identify the subnet where the sensor is located.
Start Address: define the beginning of the IP address pool which assigns to DHCP clients.
End Address: define the end of the IP address pool which assigns to DHCP clients.
Lease Time (min): the lease time on which the DHCP client can use the IP address assigned by the sensor.
| Primary DNS Server: translate the domain name to IP address.
---|---
Secondary DNS Server: backup DNS server.
Static IP Settings| Add MAC address and static IP address if users need to add a static IP address to a specific computer.

4.3 Advanced Settings
4.3.1 Security
User

Parameters Description
Security Question Click the Edit button to set three security questions

for your sensor. In case you forget the password, you can click Forget Password button on the login page to reset the password by answering three security questions correctly.

There are twelve default questions below, you can also customize the security questions.LINOVISION S500SD LoRaWAN Wireless WorkSpace Sensor - Fig
12

Account Management| Click Add button, and it will display the Account Management page. Users can add an account by entering Admin Password, User Level, User Name, New Password, Confirm, and edit user privilege by clicking . The added account will be displayed in the account list. Users can add 20 accounts at most.
Admin Password: enter the correct admin password before adding an account.
User Level: Set the privilege for the account.
User Name: Input the user name for creating an account.
Password: Input the password for the account.
Confirm: Confirm the password.
You can edit and delete the account in the account list under the admin account. For the default admin account, you can only change the password, and it cannot be deleted.
---|---

4.3.2 Logs
The logs contain information about the time and IP that has accessed the web GUI.LINOVISION S500SD LoRaWAN Wireless WorkSpace Sensor - Fig
13

Parameters Description
Main Type Select main log types
Sub Type On the premise of the main type has been selected, select the sub-

type to narrow the range of logs
Start Time| The time log starts
End Time| The time log ends
Log Export| Export the logs
Save Period| Set the period of log saving, there are eight options to choose from: Permanent and 30/60/120/180/240/300/360 Days
Go| Input the number of logs’ page

4.4 System
All information about the hardware and software can be checked on this page.LINOVISION S500SD LoRaWAN Wireless WorkSpace Sensor - Fig
14

4.5 Maintenance
4.5.1 System Maintenance

LINOVISION S500SD LoRaWAN Wireless WorkSpace Sensor - Fig
15

Parameters Description
System Upgrade Software Version: The software version of the sensor.

Local Upgrade: Click the Choose File button and select the upgrading file, then click the Upgrade button to upgrade. After the system reboots successfully, the update is done.
You can check Reset after Upgrading to reset the camera after upgrading it.
Note: Do not disconnect the power of the device during the upgrade process.
The device will be restarted to complete the upgrade.
Maintenance| Reset settings: Click the Reset button to reset the sensor to the factory default settings
Keep the IP Configuration: Check this option to keep the IP configuration when resetting
Keep the User information: Check this option to keep the user information when resetting
Export Config File: Export configuration file.
Import Config File: Click the Choose File button and select the configuration file, click the Import button to import the configuration file.
Reboot| Restart the device immediately

4.5.2 Auto Reboot
Set the date and time to enable the Auto Reboot function, the sensor will reboot automatically according to the customized time in case of the sensor overload after running a long time. Before configuration note that the date and time should be correct.LINOVISION S500SD LoRaWAN Wireless WorkSpace
Sensor - Fig 16

Installation

Step 1: Ensure the thickness of the ceiling is more than 30 mm, then attach the mounting sticker to the ceiling and drill 4 holes with a diameter of 6 mm.
Step 2: Fix the wall plugs into the ceiling holes.
Step 3: Remove the cover on the device, then fix the device to the wall plugs via mounting screws; remember to adjust the mounting direction according to the detection area requirement and the direction sticker on the inner cover.
Step 4: Take the cover back to the device; note that the Logo should be facing the LED indicator.

Device Payload

S500SD reports basic information only when joining the network and reports people counter according to reporting settings. All data are based on the following format(HEX):

Channel1 Type1 Data1 Channel2 Type2 Data2 Channel 3
1 Byte 1 Byte N Bytes 1 Byte 1 Byte M Bytes 1 Byte
Channel Type Data Length/Byte Description
--- --- --- ---
ff 01(Protocol Version) 1 01=> V1
08(Device SN) 6 12 digits, on the product label
09 (Hardware Version) 2 01 04 => V1.4
1f(Software Version) 4 1f 07 00 4b

=> V31.7.0.75
04| c9(People Counter)| 4| Byte 1: total counter
Byte 2: how many mapped region is customized
Byte 3-4: indicate which mapped area has detected people, 0 means no people, 1 means there are people in this mapped area

Example:

ff 01 01 ff 08 66 00 b0 94 09 76 ff 09 01 00 ff 1f 1f 07 00 4b 04 c9 03 05 00 a1

Channel| Type| Value| Channel| Type| Value
ff| 01 (Protocol Version)| 01 (V1)| ff| 08 (Device SN)| 66 00 b0 94 09 76
Channel| Type| Value| Channel| Type| Value
ff| 09 (Hardware version)| 0100 (V1.0)| ff| 1f(Software version)| 1f 07 00 4b (V31.7.0.75)
Channel| Type| Value
04| c9(People Counter)| Byte 1: 03=> There are 3 people who totally
Byte 2: 05=> there are 5 mapped regions
Byte 3-Byte 4: 00 a1=>1010 0001 there are people in regions 1, 6 and 8

-END-

Documents / Resources

| LINOVISION S500SD LoRaWAN Wireless WorkSpace Sensor [pdf] User Guide