DOMETIC B57915 Air Conditioner Roof Top Unit Instruction Manual

June 17, 2024
Dometic

DOMETIC B57915 Air Conditioner Roof Top Unit

DOMETIC-B57915-Air-Conditioner-Roof-Top-Unit-PRO

Product Information

Specifications

  • Model Number: 457915, B57915, 459516, B59516, 540315, H540315, 540316, H540316, 640312, 640315, 640316
  • Serial Number: 3314851.000
  • ADB Model Number: Not specified
  • ADB Serial Number: Not specified
  • Date Purchased: Not specified

Description: This product is an air conditioner designed to be installed on the roof of a Recreational Vehicle (RV). It is intended to be installed during or after the manufacturing process of the RV. The unit can be installed by one person with brief assistance from additional personnel. Please read and follow the instructions carefully to ensure proper installation and functioning of the product. Note that Dometic Corporation reserves the right to modify appearances and specifications without notice.

Installation Instructions

  1. Ensure that the installation complies with all applicable local and national codes, including the latest editions of ANSI/NFPA70 (National Electrical Code), ANSI/NFPA 1192 (Recreational Vehicles Code) for customers in the USA, and CSA C22.1 Parts l & ll (Canadian Electrical Code), CSA Z240 RV Series (Recreational Vehicles) for customers in Canada.
  2. Read and understand all safety information and instructions provided in this manual before proceeding with the installation.
  3. Gather all necessary tools and equipment required for the installation.
  4. Identify the suitable location on the roof of the RV for installing the air conditioner.
  5. Ensure that the roof surface is clean and free from any debris.
  6.  Position the air conditioner on the chosen location and alignit properly.
  7. Securely fasten the air conditioner to the roof using the appropriate mounting brackets and hardware.
  8. Connect the necessary electrical wiring according to the electrical codes and standards.
  9. Install the air distribution box (ADB) as specified in its respective user manual.
  10. Double-check all connections and ensure that they are properly secured.
  11. Test the operation of the air conditioner to ensure it is functioning correctly.

Operating Instructions

  1. Ensure that the air conditioner is properly installed according to the installation instructions provided in this manual.
  2. Before operating the air conditioner, make sure that all windows and doors of the RV are closed for maximum efficiency.
  3. Locate the control panel of the air conditioner.
  4. Set the desired temperature using the temperature control buttons or knobs on the control panel.
  5. Select the desired fan speed (low, medium, or high) using the fan speed control buttons or knobs on the control panel.
  6. If available, choose additional settings such as mode (cooling, heating, fan-only, etc.) or timer settings as per your preference and needs.
  7. Once all desired settings are adjusted, press the power button to turn on the air conditioner.
  8. The air conditioner will start cooling or heating the RV according to the selected settings.
  9. To turn off the air conditioner, press the power button again.

FAQ

  • Q: Can I install the air conditioner by myself?
    A: Yes, one person can install the air conditioner with brief assistance from additional personnel.

  • Q: Where can I find the nearest service center or dealer?
    A: Please visit the Dometic Corporation website at www.dometic.com for information on service center and dealer locations.

  • Q: Can the appearance and specifications of the product be modified?
    A: Yes, Dometic Corporation reserves the right to modify appearances and specifications without notice.

  • Q: What safety standards should I comply with during installation?
    A: The installation must comply with all applicable local and national codes, including ANSI/NFPA70 (National Electrical Code) and ANSI/NFPA 1192 (Recreational Vehicles Code) for customers in the USA, and CSA C22.1 Parts l & ll (Canadian Electrical Code) and CSA Z240 RV Series (Recreational Vehicles) for customers in Canada.

Roof Top Unit

Description Model Use With Air Distribution Box
Model Control
Air Conditioner 457915

B57915 459516 B59516 540315 H540315 540316 H540316 640312

640315

640316

| 3314851.000| Integral Mechanical

RECORD THIS INFORMATION FOR FUTURE REFERENCE:

  • Model Number: _____
  • Serial Number: _____
  • ADB Model Number: _____
  • ADB Serial Number: _____
  • Date Purchased: _____

INTRODUCTION

This air conditioner (hereinafter referred to as “unit” or “product”) is designed and intended for installation on the roof of a Recreational Vehicle (hereinafter referred to as RV) during or after the time it is manufactured. This unit can be installed by one person with brief help from additional personnel. Use these instructions to ensure a properly installed, and properly functioning product. Dometic Corporation reserves the right to modify appearances and specifications without notice.

IMPORTANT SAFETY INSTRUCTIONS

This manual has safety information and instructions to help you eliminate or reduce the risk of accidents and injuries.

  • A. Recognize Safety Information

    • This is the safety alert symbol. It is used to alert you to potential physical injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
  • B. Understand Signal Words
    A signal word will identify safety messages and property damage messages and will indicate the degree or level of hazard seriousness.

    • WARNING indicates a hazardous situation that, if NOT avoided, could result in death or serious injury.
    • CAUTION indicates a hazardous situation that, if NOT avoided, could result in minor or moderate injury.
    • NOTICE is used to address practices NOT related to physical injury.
  • C. Supplemental Directives

    • Read and follow all safety information and instructions to avoid possible injury or death. Read and understand these instructions before [installing/using / servicing / performing maintenance on] this product. Incorrect [installation/operation/servicing/maintenance] of this product can lead to serious injury. Follow all instructions.
    • The installation MUST comply with all applicable local and national codes, including the latest edition of the following standards:
    • U.S.A.
    • ANSI/NFPA70, National Electrical Code (NEC)
    • ANSI/NFPA 1192, Recreational Vehicles Code
    • CANADA
    • CSA C22.1, Parts l & ll, Canadian Electrical Code
    • CSA Z240 RV Series, Recreational Vehicles
  • D. General Safety Messages
    WARNING Failure to obey the following warnings could result in death or serious injury:

    • This product MUST be [installed/serviced] by a qualified service technician.
    • Do NOT modify this product in any way. Modification can be extremely hazardous.
    • Do NOT add any devices or accessories to this product except those specifically authorized in writing by Dometic Corporation.

SPECIFICATIONS

Table – Unit DataDOMETIC-B57915-Air-Conditioner-Roof-Top-Unit-
\(1\)

  • For wire length over 24 ft., consult the National Electrical Code for proper sizing.
  • Dometic Corporation gives GENERAL guidelines for generator requirements. These guidelines come from experiences people have had in actual applications. When sizing the generator, the total power usage of your RV must be considered. Keep in mind generators lose power at high altitudes and from lack of maintenance.
  • CIRCUIT PROTECTION: Time Delay Fuse or Circuit Breaker Required.

Roof Requirements

  • A 14-1/4″ x 14-1/4″ (±1/8″) square opening (hereinafter referred to as “roof opening”) is required for installing this unit. This opening is part of the return air system of the unit and MUST be finished by NFPA 1192.
  • Roof construction with rafters/joists support frames on a minimum of 16-inch centers.
  • Minimum of 1.5 inches and maximum of 6 inches distance between roof to ceiling of RV.

INSTALLATION INSTRUCTIONS

Choosing Proper Location For Unit
This unit is specifically designed for installation on the roof of an RV. When determining your cooling requirements, the following should be considered:

  • Size of RV;
  • Window area (increases heat gain);
  • Amount of insulation in walls and roof;
  • Geographical location where the RV will be used;
  • Personal comfort level required.
  1. Normal The unit is designed to fit over an existing roof vent opening.

  2. Other locations where no roof vent is available or another location is desired, the following is recommended:

    • a. For one unit installation: The unit should be mounted slightly forward of center (front to back) and centered from side to side.

    • b. For two unit installations: Install one unit 1/3 and one unit 2/3’s from front of RV and centered from side to side.
      It is preferred that the unit be installed on a relatively flat and level roof section measured with the RV parked on a level surface. See table for maximum acceptable tilt.DOMETIC-B57915-Air-Conditioner-Roof-Top-Unit-
\(2\)
      After Location Has Been Selected:

    • c. Check for obstructions in the area where unit will be installed. See (FIG. 1), (FIG. 2), (FIG. 3), (FIG. 4), (FIG. 5) & (FIG. 6).DOMETIC-B57915-Air-Conditioner-Roof-Top-Unit- \(3\) DOMETIC-B57915-Air-Conditioner-Roof-Top-Unit- \(4\) DOMETIC-B57915-Air-Conditioner-Roof-Top-Unit- \(5\)

    • d. NOTICE Maintain structural integrity. Otherwise, damage to product and/or RV could occur.
      The roof must be designed to support 130 pounds when RV is in motion. Normally a 200 lb. static load design will meet this requirement.

    • e. Check inside the RV for air distribution box (hereinafter referred to as “ADB”) obstructions (i.e. door openings, room dividers, curtains, ceiling fixtures, etc.). See (FIG. 7).

Roof Preparation

  1. WARNING FIRE OR ELECTRICAL SHOCK HAZARD. Make sure there are no obstacles (wires, pipes, etc.) inside RV’s [roof/floor/walls]. Shut OFF gas supply, disconnect 120 Vac power from RV, and disconnect positive (+) 12 Vdc terminal from supply battery BEFORE drilling or cutting into RV. Failure to obey these warnings could result in death or serious injury.

  2. Opening Requirements – Before preparing the ceiling opening, read all of the following instructions before beginning the installation.
    If an existing roof vent opening will NOT be used a roof opening MUST be cut through the roof and ceiling of the RV. This opening MUST be located between the roof reinforcing members.

    • a. Roof vent removal

    • b. Unscrew and remove the roof vent.

    • c. Remove all caulking compounds around the opening.

    • d. Seal all screw holes and seams where the roof gasket will be located. Use a good grade of all-weather sealant.
      If the opening exceeds 14-3/8″ x 14-3/8″, it will be necessary to resize the opening. See “B. Roof Requirements” on page (4).

    • e. If the opening is less than 14-1/8″ x 14-1/8″, it must be enlarged. See “B. Roof Requirements” on page (4).

  3. New opening

    • a. Carefully mark and cut the required roof opening. See “B. Roof Requirements” on page (4).
    • b. NOTICE Maintain structural integrity. Otherwise, damage to product and/or RV could occur.
      NOTICE NEVER create a low spot on RV roof. Otherwise, water will pool and could cause a leak.
      Using the roof opening as a guide, cut the matching hole in the ceiling.
      The opening created must be framed to provide adequate support and prevent air from being drawn from the roof cavity. Framing stock 3/4″ or more in thickness must be used. Remember to provide an entrance hole for power supplies at the front of the opening. See (FIG. 8).

Wiring Requirements

  1. Route a copper, with ground, 120 Vac supply wire from the time delay fuse or circuit breaker box to the roof opening. Use a listed/certified nonmetallic – sheathed single-strand cable. See “A. Table – Unit Data” on page (4).
    If vent fan was removed, the existing wire may be used provided it is of proper type, size, location, and correctly fused.

    • a. This supply wire must be located in the front portion of the roof opening.
    • b. The power MUST be on an appropriately sized separate time delay fuse or circuit breaker. See “A. Table – Unit Data” on page (4).
    • c. Make sure that at least 15″ of supply wire extends into the roof opening. This ensures an easy connection at the junction box.
    • d. Protect the wire where it passes into the opening with approved method.

Placing Unit On Roof

  1. Remove the unit from the carton and discard carton.

  2. CAUTION LIFTING HAZARD. Use proper lifting technique and control when lifting product. Failure to obey this caution could result in injury. Place unit on the roof.

  3. NOTICE Do NOT slide unit. Otherwise, damage to gasket (on bottom of unit) may occur, and could cause a leak.
    Lift and place the unit over the prepared opening using the gasket on the unit as a guide. See (FIG. 9).

  4. Place the ADB kit inside the RV. This box contains mounting hardware for the unit and will be used inside the RV.
    This completes the outside work. Minor adjustments can be done from inside the RV if required.

Installation Preparation

  1. Check gasket alignment of the unit over the roof opening and adjust if necessary. Unit may be moved from below by slightly lifting. See (FIG. 10).
  2. Remove ADB and mounting hardware from carton. See (FIG. 11).
  3. All models in this manual will use a four (4) bolt pattern for installing the ADB kit.
  4. Reach up into the return air opening of the unit and pull the unit electrical cord down for later connection. See (FIG. 12).

Duct Divider Installation

  1. Measure the ceiling thickness. See (FIG. 12).
  2. Cut away the number of rows as indicated in the table below. See (FIG. 13).
    H540315, H540316|  | 457915, B57915

459516, B59516

540315, 540316

640312, 640315,

640316

---|---|---
Ceiling Thickness| # Of Rows To Cut| Ceiling Thickness
Min.| Max.| Min.| Max.
5.75| 6.25| 0| 6.0| 6.5
5.25| 5.75| 1| 5.5| 6.0
4.75| 5.25| 2| 5.0| 5.5
4.25| 4.75| 3| 4.5| 5.0
3.75| 4.25| 4| 4.0| 4.5
3.25| 3.75| 5| 3.5| 4.0
2.75| 3.25| 6| 3.0| 3.5
2.25| 2.75| 7| 2.5| 3.0
1.75| 2.25| 8| 2.0| 2.5
1.25| 1.75| 9| 1.5| 2.0

  1. Carefully install the duct divider in the roof opening 5-5/8″ from back of roof opening. See (FIG. 14).
    Foil back faces rear of unit.

Installing Unit

  1. Ceiling Template Installation
    • a. Plug the 6 pin electrical cord from the top unit into the matching 6 pin connector in the electronic control box. The plug is polarized and will only fit in one direction. See (FIG. 15).
    • b. Install supplied nonmetallic cable connector in junction box hole cutout. See (FIG. 15) for proper orientation.
    • c. Route the previously run 120 Vac power sup-ply wire through cable connector and into junction box.
    • d. Secure 120 Vac power supply by tightening cable connector clamp making sure not to damage wires. See (FIG. 15).
    • e. Hold the ceiling template up to the roof opening and line up the channel in the ceiling template with the previously installed duct divider. See (FIG. 16).
    • f. Hold the ceiling template up to the roof opening and start each mounting bolt, by hand, through the ceiling template and up into the unit base pan. See (FIG. 17) & (FIG. 18).DOMETIC-B57915-Air-Conditioner-Roof-Top-Unit- \(15\)
    • g. NOTICE Tighten mounting bolts to correct torque specifications. Overtightening could damage unit’s base pan or ceiling template. Not enough torque will allow an inadequate roof seal, and could cause a leak. Tighten all four (4) mounting bolts EVENLY within 40 to 50 inch pounds. See (FIG. 18).

120 Vac Power Supply Connection

  1. WARNING  ELECTRICAL SHOCK HAZARD. Make sure 120 Vac power is disconnected from RV. Failure to obey this warning could result in death or serious injury.
  2. WARNING ELECTRICAL SHOCK HAZARD. Provide grounding in compliance with all applicable electrical codes. Failure to obey this warning could result in death or serious injury.
  3. Connect white to white; black to black; using appropriate size connectors. Secure bare copper wire under grounding screw in junction box. See (FIG. 19).
  4. Tape the connectors to the supply wire to ensure they don’t vibrate loose.
  5. Push the wires into the junction box and install junction box cover. See (FIG. 19).

Installing ADB

  1. Align ADB with ceiling template. See (FIG. 20) & (FIG. 21).
    Front and rear vent doors are supplied loose. Do NOT install them until all screws are installed in step 2 & 3.

  2. Install two (2) (supplied) sheet metal screws in-side return air opening to secure ADB to ceiling template. See (FIG. 22).

  3. Install eight (8) (supplied) wood screws inside the front, rear and side doors to secure ADB to ceiling. See (FIG. 22).

  4. Install front and rear doors.

  5. Place filter in return air vent grille. It may already be installed on some units. See (FIG. 23).

  6. Install return air vent grille into the ADB. Slide return air vent grille tab into slot in ADB and rotate up and snap in place. See (FIG. 24).

  7. Install the control knobs into the ADB. See (FIG. 25).

  8. The unit installation is now complete and is ready for operation. The power supply to the unit may now be turned on.

  9. Verify that all features of the installed system work. Please read the following operating instructions before attempting to run the unit.

OPERATING INSTRUCTIONS

Controls

  1. The Selector Switch has (8) positions including “OFF”. This controls fan speeds, cooling modes and optional heating modes of operation. See (FIG. 26).
  2. The thermostat controls the compressor On/ OFF operation within a temperature range of approximately 65° F and 90° F measured at the ADB inlet.

“OFF” Position ( )

  1. This is to turn unit off.

Cooling Operation (Blue Graphic)

  1. Turn selector switch to cooling (blue graphic).
  2. Set the thermostat at the desired temperature level.
  3. Select the fan speed that best satisfies your needs:
    • a. HIGH COOL: Selected when maximum cooling and dehumidification required.
    • b. MEDIUM COOL: Selected when normal cooling required.
    • c. LOW COOL: Selected when room is at desired comfort level and needs to be maintained. Normally this speed is used for nighttime operation.
      The compressor will cycle on and off as cooling is required to maintain the selected temperature level. The fan runs when the compressor is off to help keep the temperature uniform throughout the RV.

NOTICE Wait at least 2 minutes before re-starting the compressor when it has been manu-ally cycled off with either the selector switch or the temperature set lever. Otherwise, the compressor will quickly cycle and could result in compressor or supply circuit overload.

Heating Operation (With Electric Heater Option Installed).
The heat mode of operation will NOT replace a furnace for heating your RV in cold weather. The intent is to remove the chill on cool days or mornings.

  1. Turn the selector switch to “OPT HEAT”.
  2. The heat strip will come on and begin heating.
  3. When the desired temperature level in RV is reached, move the selector switch to “OFF” position or “FAN” position.
    The thermostat does NOT control the fan/heater ON/OFF cycle.

Fan Operation (Black Graphic)
This will circulate the air in your RV without cooling or heating.

  1. Turn the selector switch to fan (black graphic). There are three positions to select from (high, medium and low). See (FIG. 26).

Center Air Discharge

  1. Slide lever to open and close. See (FIG. 27).

MAINTENANCE

Air Filter

  1. Periodically (a minimum of every 2 weeks of operation) remove the return air filter located behind the return air vent grille and wash it with soap and warm water, let dry and then reinstall.
    NEVER run unit without return air filter in place. This will plug the unit evaporator coil with dirt and may substantially degrade the performance of the unit over time.

ADB Housing

  1. Clean ADB housing and control panel with a soft cloth dampened with a mild detergent. Never use furniture polish or scouring powders.

Fan Motor

  1. The blower motor is factory-lubricated and requires no service.

GENERAL INFORMATION

Frost Formation On Cooling Coil
Frost on a small portion of the coil is not unusual. Under certain conditions, ice may form on the evaporator coil. This is indicated by very cold output at very low air speed and the icing can be seen through the air inlet hole with the filter removed. If this should occur, inspect the filter and clean if dirty. Make sure air vents are open and not obstructed. Units have a greater tendency to frost when the outside temperature is relatively low. This may be prevented by adjusting the thermostat control knob to a warmer setting (counterclockwise). Should frosting continue, operate on any FAN ONLY setting until the cooling coil is free of frost; then resume normal operation. If frost condition persist, contact your local service center for assistance.

Heat Gain
The ability of this air conditioner to maintain the desired inside temperature depends on the heat gain of the RV.
Some preventative measures taken by the occupants of the RV can reduce the heat gain and improve the performance of the air conditioner. During extremely high outdoor temperatures, the heat gain of the RV can may be reduced by:

  1. Parking the RV in a shaded area
  2. Using window shades (blinds and/or curtains)
  3. Keeping windows and doors shut or minimizing usage
  4. Avoid the use of heat-producing appliances

Operation on High Fan/Cooling mode will give optimum or maximum efficiency in high humidity or high outside temperatures. Starting the air conditioner early in the morning and giving it a “head start” on the expected high outdoor ambient will greatly improve its ability to maintain the desired indoor temperature. For a more permanent solution to high heat gain, accessories like Dometic outdoor patio and window awnings will reduce heat gain by removing the direct sun. They also add a nice area to enjoy company during the cool of the evening.

Condensation
The manufacturer of this unit will not be responsible for damage caused by condensation forming on ceilings, windows, or other surfaces. Air contains water vapor which condenses when temperature of a surface is below Dew point. During normal operation this unit is designed to remove a certain amount of moisture from the air, depending on the size of the space being conditioned. Keeping doors and windows closed when this air conditioner is in operation will greatly reduce the chance of condensation forming on interior surfaces.

Air Distribution
Each A/C unit operating in cool mode, must have a minimum of 2 distribution vents, or the quick cool vent and one vent open, to avoid the risk of freezing coils and improper function.

SERVICE – UNIT DOES NOT OPERATE
If your unit fails to operate or operates improperly, check the following before calling your service center.

  • If RV connected to motor generator, check to be sure motor generator is running and producing power.
  • If RV connected to power supply by a land line, check to be sure line is sized properly to run unit load and it is plugged into power supply.
  • Check your fuse or circuit breaker to see if it is open. Ensure fuse is not burnt, or circuit breaker is “ON” and not activated.
  • After the above checks, call your local service center for further help. This unit must be serviced by qualified service personnel only.

When calling for service, always give the following:

  • Unit model and serial number found on the identification label located on base pan of unit bottom. Return air vent grille must be removed from ADB to view.
  • ADB model and serial number found on rating plate located on ceiling template. Observe this rating plate through the filter opening.

WIRING DIAGRAMS

Unit Wiring Diagrams

  1. 457915, 459516, B57915 & B59516DOMETIC-B57915-Air-Conditioner-Roof-Top-Unit- \(26\)
  2. 540315, 540316, H540315 & H540316DOMETIC-B57915-Air-Conditioner-Roof-Top-Unit- \(27\)
  3. 640312, 640312C, 640315, 640315C, 640316DOMETIC-B57915-Air-Conditioner-Roof-Top-Unit- \(28\)

ADB Wiring Diagram

DOMETIC-B57915-Air-Conditioner-Roof-Top-Unit- \(29\)

REVISION E
Form No. 3315079.016 6/18 (French 3315288.013_E) ©2018 Dometic Corporation LaGrange, IN 46761

USA & CANADA
SERVICE OFFICE Dometic Corporation 1120 North Main Street Elkhart, IN, 46514

SERVICE CENTER & DEALER LOCATIONS Please Visit: www.dometic.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Dometic User Manuals

Related Manuals