LINOVISION IOT-C51x Series Solenoid Valve Controller User Guide Product Information
- May 15, 2024
- LINOVISION
Table of Contents
IOT-C51x Series Solenoid Valve Controller
Product Information
Specifications
-
Product Name: IOT-C51x Series
-
Transmission Distance: Up to 15 km with line of sight
-
Waterproof Design: IP67 case and M12 connectors
-
Power Source: Solar powered with built-in chargeable
battery -
Wireless Configuration: Quick setup via NFC
-
Control Options: OPEN/CLOSE control by mobile app or remote
commands -
Interfaces: Two GPIO interfaces for flow monitoring or valve
status monitoring
Product Usage Instructions
1. Product Introduction
1.1 Overview
The IOT-C51x Series is compatible with standard DC latching
solenoids, allowing for OPEN/CLOSE control either locally through a
mobile app or remotely via commands. It features two GPIO
interfaces for flow monitoring or valve status monitoring.
1.2 Features
-
Compatible with standard DC latching solenoids
-
OPEN/CLOSE control by mobile app locally or commands
remotely -
Two GPIO interfaces for flow monitoring or valve status
monitoring -
Transmission distance up to 15 km with line of sight
-
Waterproof design including IP67 case and M12 connectors
-
Solar powered and built-in chargeable battery
-
Quick wireless configuration via NFC
-
Time and flow control via Milesight IoT Cloud
2. Hardware Introduction
FAQ
Q: How can I reset the device?
A: To reset the device, press and hold the power button for more
than 10 seconds.
Q: What is the default password for configuration?
A: The default password for configuration is 123456.
LoRaWAN® Solenoid Valve Controller
IOT-C51x Series
User Guide
Revision History
Date Feb. 20, 2021 Nov.26, 2021 March 10, 2021
June 15, 2022
Nov. 21, 2022
Doc Version V 1.0 V 1.1 V 2.0
V 2.1
V 2.2
Description Initial version Description Update Update based on 2.0 hardware 1. Add internal interface description; 2. UC511 supports Class C to B mode; 3. GPIO supports selecting DI or pulse mode; 4. Update re-join mode and confirmed mode description. Add prevent jitter delay time when GPIO works as DI mode
3
Contents
1. Product Introduction …………………………………………………………………………………………………………. 5 1.1
Overview …………………………………………………………………………………………………………………..5 1.2 Features
………………………………………………………………………………………………………………….. 5
2. Hardware Introduction ………………………………………………………………………………………………………. 5 2.1
Packing List ………………………………………………………………………………………………………………5 2.2 Hardware Overview
………………………………………………………………………………………………….. 6 2.3 Internal Interfaces
……………………………………………………………………………………………………. 6 2.4 Dimensions
……………………………………………………………………………………………………………… 7
3. Operation Guide …………………………………………………………………………………………………………………7 3.1 Log in
the ToolBox …………………………………………………………………………………………………….7 3.1.1 NFC Configuration
………………………………………………………………………………………….. 7 3.1.2 USB Configuration
………………………………………………………………………………………….. 8 3.2 Solenoid Valve Control
……………………………………………………………………………………………… 9 3.3 LoRaWAN Settings
…………………………………………………………………………………………………. 10 3.4 Solenoid Settings
…………………………………………………………………………………………………….13 3.5 Schedule Settings
……………………………………………………………………………………………………15 3.6 Maintenance
………………………………………………………………………………………………………….. 16 3.6.1 Upgrade
……………………………………………………………………………………………………….. 16 3.6.2 Backup
………………………………………………………………………………………………………….17 3.6.3 Reset to Factory Default
…………………………………………………………………………………18
4. Installation ……………………………………………………………………………………………………………………… 19 5.
Linovision IoT Cloud Management …………………………………………………………………………………….. 20 5.1 Add
UC51x to Cloud ……………………………………………………………………………………………….. 20 5.2 Solenoid Valve
Control …………………………………………………………………………………………….22
6. Device Payload ……………………………………………………………………………………………………………….. 24
4
1. Product Introduction 1.1 Overview
IOT-C51x series LoRaWAN® wireless solenoid valve controller is a device used
to remotely control DC latching solenoids of the valve. It contains 2 solenoid
interfaces and 2 GPIO interfaces, which can be easily controlled locally or
remotely. Besides ultra-low-power LoRaWAN® technology, IOT-C51x series also
provides both solar andbuiltin battery power supply for uninterrupted
operation. For outdoor applications, it equips withIP67rated enclosure and M12
connectors to protect from water and dust under harsh environments.
1.2 Features
Compatible with standard DC latching solenoids OPEN/CLOSE control by mobile
App locally or commands remotely Two GPIO interfaces for flow monitoring or
valve status monitoring Transmission distance up to 15 km with line of sight
Waterproof design including IP67 case and M12 connectors Solar powered and
built-in chargeable battery Quick wireless configuration via NFC Time and flow
control via Milesight IoT Cloud
2. Hardware Introduction 2.1 Packing List
1 × C51x Device
2 × Data Cables (30 cm)
1 × Mounting Bracket
4 × Wall Mounting Kits
2 × Hose Clamps 1 × Fixing Screw 1 × Quick Guide 1 × Warranty Card If any of the above items is missing or damaged, please contact your sales Representative.
5
2.2 Hardware Overview
C511
Interface 1&2:
Pin
Description
1
DC+/OUT1 of Solenoid Valve
2
DC-/OUT2 of Solenoid Valve
3
GND
4
INSERT BOOT1
5
GND
6
GPIO Interface
2.3 Internal Interfaces
C512
1 PIN3 and PIN4 do not need to connect, see “Solenoid Valve Switch” option in
section 3.4.
6
DIP Switch: Interface
Solenoid Interface
DIP Switch 12V: 1 on 2 off 3 off 9V: 1 off 2 on 3 off 5V: 1 off 2 off 3 on
Note: 1) The DIP switch is set to 12VDC by default. 2) The DIP switch does not support setting two solenoid interfaces as different voltage types.
Power Button:
Function
Action
Turn On Press and hold the button for more than 3s.
Turn Off Press and hold the button for more than 3s.
Reset
Press and hold the button for more than 10s.
Check Quickly press the power button.
On/Off Status
LED Indication Off On On Off Blinks. Light On: Device is on. Light Off: Device is off.
2.4 Dimensions (mm)
3. Operation Guide 3.1 Log in the ToolBox
IOT-C51x series can be monitored and configured via ToolBox App or ToolBox
software. Pleaseselect one of them to complete configuration.
3.1.1 NFC Configuration
1. Download and install “ToolBox” App from Google Play or Apple App Store.
7
2. Enable NFC on the smartphone and launch Milesight ToolBox. 3. Attach the
smartphone with NFC area to the device to read basic information. 4. Basic
information and settings of devices will be shown on ToolBox if it’s
recognized successfully. You can read and configure the device by tapping the
button on the Device Status. In order to protect the security of devices,
password validation is required when first configuration. Default password is
123456.
Note: 1) Ensure the location of smartphone NFC area and it’s recommended to
take off phone case. 2) If the smartphone fails to read/write configurations
via NFC, keep the phone away and back to try again. 3) C51x series can also be
configured by dedicated NFC reader, which can be purchased from Milesight IoT.
3.1.2 USB Configuration
1. Download ToolBox 2. Open the case of C51x and connect the C51x to computer
via type-C port.
3. Open the ToolBox and select type as “General”, then click password to log
in ToolBox. (Default password: 123456)
8
4. After logging in the ToolBox, you can click “Power On” or “Power Off” to
turn on/off device and change other settings.
3.2 Solenoid Valve Control
Solenoid valve can be controlled by ToolBox App or ToolBox software locally.
Via ToolBox Software: Click “Open” or “Close” button on the “Status” page to
change the status of solenoid valves.
9
Via ToolBox App: Click buttons of Valve Status on the “Device -> Status” page,
then attach the smart phone to device to change the status of solenoid valves.
3.3 LoRaWAN Settings
LoRaWAN settings is used for configuring the transmission parameters in
LoRaWAN® network.
Basic LoRaWAN Settings:
Go to “LoRaWAN Settings -> Basic” of ToolBox software or “Setting -> LoRaWAN
Settings” of ToolBox App to configure join type, App EUI, App Key and other
information. You can also keep all settings by default.
10
Parameters
Description
Device EUI
Unique ID of the device which can also be found on the label.
App EUI
Default App EUI is 24E124C0002A0001.
Application Port The port used for sending and receiving data, default port is 85.
Join Type
OTAA and ABP mode are available.
LoRaWAN Version V1.0.2, V1.0.3, V1.1 are available.
Application Key Appkey for OTAA mode, default is 5572404C696E6B4C6F52613230313823.
Device Address DevAddr for ABP mode, default is the 5th to 12th digits of SN.
Network Session Nwkskey for ABP mode, default is
5572404C696E6B4C6F52613230313823.
Key
Application Session Key
Appskey for ABP mode, default is 5572404C696E6B4C6F52613230313823.
RX2 Data Rate RX2 data rate to receive downlinks.
RX2 Frequency RX2 frequency to receive downlinks. Unit: Hz
Spread Factor If ADR is disabled, the device will send data via this spread factor.
If the device does not receive ACK packet from network server, it will resend
Confirmed Mode
data once.
Rejoin Mode The device will send a specific number of LinkCheckReq MAC packets to the
11
network server every 30 mins to validate connectivity; If there is no response,
the device will re-join the network.
Set the number of When rejoin mode is enabled, set the number of LinkCheckReq
packets sent.
packets sent
ADR Mode
Allow network server to adjust datarate of the device.
Tx Power
Tx power of the device.
Note:
-
Please contact sales for device EUI list if there are many units.
-
Please contact sales if you need random App keys before purchase.
-
Select OTAA mode if you use Milesight IoT cloud to manage devices.
-
Only OTAA mode supports rejoin mode.
LoRaWAN Frequency Settings:
Go to “LoRaWAN Settings-> Channel” of ToolBox software or “Setting -> LoRaWAN
Settings” of ToolBox APP to select supported frequency and select channels to
send uplinks. Make sure the channels match the LoRaWAN® gateway.
If frequency is one of CN470/AU915/US915, you can enter the index of the
channel that you want to enable in the input box, making them separated by
commas. Examples: 1, 40: Enabling Channel 1 and Channel 40 1-40: Enabling
Channel 1 to Channel 40 1-40, 60: Enabling Channel 1 to Channel 40 and Channel
60 All: Enabling all channels Null: Indicates that all channels are disabled
12
Note: For -868M model, default frequency is EU868; For -915M model, default
frequency is AU915.
3.4 Solenoid Settings
Go to “Device Settings -> Basic” of ToolBox software or “Setting -> General
Settings” of ToolBox App to change the reporting configurations.
Parameters Reporting Interval
Solenoid Valve Wiring Switch
Description Reporting interval of transmitting data to network server. Default: 20min, Range: 1-1080 mins. After this parameter is enabled, when users connect the solenoid cable to any solenoid interface, the device will turn on automatically.
13
Select Digital Input or Pulse Counter.
GPIO1/2
Digital input: detect the real state of valve to know if valve control takes
Acquisition Type effect.
Pulse counter: connect water meter to measure the flow.
Prevent Jitter Delay Time
The device will not upload GPIO status during this time to avoid frequent uplinks. This only works when GPIO mode is DI and also applies to both GPIO interfaces.
Select the contents to report to network server.
All: Report all interface status;
Data Reporting
Valve 1 & Water Meter 1: Report the status of the Valve 1 interface and data of GPIO1;
Valve 2 & Water Meter 2: Report the status of the Valve 2 interface and
data of GPIO2.
Device Return to If the device loses power and return to power supply, the device will be on
Power Supply State or off according to this parameter. Working mode of LoRaWAN® device.
UC511: Class A, Class B and Class C, Class C to B are available;
UC512: Class A and Class B are available.
Class Type
Note: for Class B mode, if the device does not receive beacons for more
than 30 minutes, it will switch to Class A mode automatically; for Class C
to B mode, if the device does not receive beacons for more than 30
minutes, it will switch to Class C mode automatically.
When the device works under Class A mode, it only receives control
commands every reporting interval comes. In order to shorten the delay
Response Time time of control, the device will send blank package to allow to receive the
control commands every Response Time interval.
Note: The shorter the response time, the shorter the battery life.
Ping Slot
When the device works under Class B or Class C to B mode, set the
Periodicity
interval to open the reception window.
Change the password for ToolBox App or software to read/write this Change
Password
device.
Note:
- When device connects to network server of Milesight gateway, the blank package will take up
the frame count but not show on the package list.
14
- Reboot or re-join will not affect the counting.
3.5 Schedule Settings
Go to “Device Settings -> Schedule” of ToolBox software or “Setting -> Schedule” of ToolBox App to configure the solenoid switch plans. 1. Configure a plan as your request and enable it.
Condition Item Status
Initial State of Solenoid Valve Start Time/End
Time
Water Volume (Pulses)
Repeat
Description It supports adding 16 plans at most. Enable or disable this plan.
Control the solenoid to open or close the valve during the plan.
Set the time range to execute this plan.
Set the amount of water flow through the valve during this plan, 0 means this
condition will not work. Note: 1) Either time or water volume reaches the
condition, the plan is completed and will stop executing. 2) When the GPIO
type is not pulse counter, this condition will not work. Set the regularly
weekly schedule to execute this plan. If none is selected, the plan will only
execute once.
15
Valve
Select the valve you need to control.
2. Click “Write” to write the schedule plan setting into the device. 3. Click “Save Schedule” to backup the schedule plan settings as file; if you need to import this schedule from other devices, click “Read Schedule” to import the setting. 4. Click “Clear All” to reset all schedule plan settings in this device. Note: 1) Ensure the device time is correct. After joining the network, the network server will assign the time to the device. You can also manually sync the time via ToolBox or downlink commands. 2) When the device has multiple schedule plan settings that are conflicted, the device will only execute one plan whose item number is largest.
3.6 Maintenance
3.6.1 Upgrade ToolBox Software:
1. Download firmware to your PC. 2. Go to “Maintenance -> Upgrade” of ToolBox
software, click “Browse” to import firmware and upgrade the device. You can
also click “Up to Date” to search for the latest firmware of the device and
upgrade.
16
ToolBox App:
1. Download firmware from www.milesight-iot.com to your smartphone. 2. Open
ToolBox App and click “Browse” to import firmware and upgrade the device.
Note: 1) Operation on ToolBox is not supported during the upgrade. 2) Only
Android version ToolBox supports the upgrade feature.
3.6.2 Backup
C51x devices support configuration backup for easy and quick device
configuration in bulk. Backup is allowed only for devices with the same model
and LoRa frequency band. Note that the backup file will not save schedule
setting, please backup plan setting on “Schedule” page. Please select one of
following methods to backup device:
ToolBox Software:
1. Go to “Maintenance -> Backup and Reset”, click “Export” to save current
configuration as json format backup file. 2. Click “Browse” to select backup
file, then click “Import” to import the configurations.
17
ToolBox App:
1. Go to “Template” page on the App and save current settings as a template.
You can also edit the template file. 2. Select this template and attach to
another device to write configuration.
3.6.3 Reset to Factory Default
Please select one of following methods to reset device: Via Hardware: Open the
case of C51x and hold on power button more than 10s. Via ToolBox Software: Go
to “Maintenance -> Backup and Reset” to click “Reset”.
18
Via ToolBox App: Go to “Device -> Maintenance” to click “Reset”, then attach
smart phone with NFC area to UC51x to complete reset.
4. Installation
UC51x series support wall mounting or pole mounting. Before installation, make
sure you have the mounting bracket, wall or pole mounting kits and other
required tools.
Wall Mounting:
1. Fix the wall plugs into the wall, then fix the mounting bracket to the
wall plugs with screws. 2. Put the device on the mounting bracket, then fix
the bottom of the device to the bracket with a fixing screw. It’s necessary to
fix this bracket to device, or it will affect the signal.
19
Pole Mounting:
1. Straighten out the hose clamp and slide it through the rectangular rings
in the mounting bracket, wrap the hose clamp around the pole. After that use a
screwdriver to tighten the locking mechanism by turning it clockwise. 2. Put
the device on the mounting bracket, then fix the bottom of the device to the
bracket with a fixing screw. It’s necessary to fix this bracket to device, or
it will affect the signal.
5. IoT Cloud Management
C51x series can be managed by IoT Cloud platform. IoT cloud is a comprehensive
platform that provides multiple services including device remote management
and data visualization with the easiest operation procedures. Please register
a IoT Cloud account before operating following steps.
5.1 Add C51x to Cloud
1. Ensure Linovision LoRaWAN® gateway is online in Linovision IoT Cloud. For
more info aboutconnecting gateway to cloud please refer to gateway’s user
guide.
20
2. Go to “My Devices” page and click “+New Devices”. Fill in the SN of UC51x and select associated gateway.
3. Click
and go to “Basic Settings” to change class type the same as device settings.
Besides, configure the unit of per pulse if you connect the water meter. 21
4. Click
and go to “Interface Settings” to select used interfaces and customize the name
and thresholds.
5.2 Solenoid Valve Control
Solenoid valve can be controlled by Milesight IoT cloud webpage or App.
1. Click
to open the solenoid valve and configure the duration. Note that if you enable any
local plan on UC51x device, this control will not work.
22
You can also add a switch on the dashboard to control the status of solenoid
valves.
Note: If the working mode of UC51x is LoRaWAN® Class A, control commands will
delay until the time icon disappear.
2. Go to “Triggers” page to add actions to trigger the solenoid valve to open
for a period of time or a specific volume of water. Note: Water volume control
is only worked when you connect water meter to UC51x device.
23
6. Device Payload
UC51x Series use the standard Milesight IoT payload format based on IPSO.
Please refer to the UC51x Series Communication Protocol; for decoders of
Milesight IoT products please clic
-END-
24
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>