FISHER PAYKEL CID834DTB4 Downdraft Induction Cooktop Installation Guide

June 5, 2024
Fisher & Paykel

FISHER-PAYKEL-logo

FISHER PAYKEL CID834DTB4 Downdraft Induction Cooktop

FISHER-PAYKEL-CID834DTB4-Downdraft-Induction-Cooktop-
image

SAFETY AND WARNINGS

WARNING!

Electric Shock Hazard
Failure to follow this advice may result in electric shock or death.

  • Disconnect the appliance from the mains electricity supply before carrying out any work or maintenance.
  • Connection to a good earth wiring system is essential and mandatory.
  • Alterations to the domestic wiring system must only be made by a qualified electrician.

WARNING!

Cut Hazard
Failure to use caution could result in injury.

  • Take care: some edges are sharp.

General Use

  • Read these instructions carefully before installing this product.
  • Save these instructions for the local electrical inspector’s use.
  • Installation must comply with your local building and local electricity regulations.
  • This appliance is to be installed and serviced only by Fisher & Paykel trained and supported service technician or qualified person.
  • The manufacturer accepts no responsibility for the incorrect installation of appliances. Incorrect installation may result in personal injury, damage to property and may invalidate any warranty or liability claims.
  • Do not modify this appliance.
  • Do not use or store flammable materials on or near this appliance.
  • Packing elements (eg plastic bags, polystyrene foam, staples, packing straps etc) and tools should not be left around during and after installation, especially if they are within easy reach of children, as these may cause serious injuries.
  • Make sure you recycle the packaging material.
  • Before disposing of any appliance, make sure that it can no longer be used and that all hazardous parts are removed or made harmless, so that children playing with the old appliance cannot harm themselves.
  • Only genuine replacement parts may be used for servicing the appliance. These are available from your nearest Fisher & Paykel Service Center.
  • This cooktop must be connected to the mains power supply only by a suitably qualified person.
  • DO NOT use adapters, reducers, or branching devices when connecting the cooktop to the mains power supply to prevent overheating and fire.
  • The power supply cable must not touch any hot parts and must be positioned so that its temperature will not exceed 75 oC at any point.
  • CAUTION: This appliance is not intended to be used with gas hobs.

WARNING!
To prevent overheating of the electronic components adequate supply of cool air and direct unrestricted ventilation to the room is required. A gap of min. 4mm height over the width of the cooktop chassis is required to allow the internal ventilators operating unrestricted. (Refer to ‘Clearances’)

INSTALLATION CONSIDERATIONS

BEFORE INSTALLATION

Please ensure the following:

  • A suitable disconnection switch is incorporated in the permanent wiring, mounted and positioned to comply with the local wiring rules and regulations. A means of disconnection with at least a 3mm air gap contact separation in all poles must be incorporated into the fixed wiring in accordance with the wiring rules, unless the local wiring rules allow for alternative means.
  • The benchtop is made of a heat resistant material.
  • There is adequate flow of cool air from the cabinetry to the base of the cooktop. You may ventilate from adjacent cupboards, but ensure that the available air supply will not be restricted.
  • The ventilation area must be equivalent to 40cm2 Refer to ‘Clearances’.
  • The power supply cable is not accessible through cupboard doors or drawers.
  • The isolating switch is easily accessible by the customer.
  • You use heat-resistant and easy-to-clean finishes (such as ceramic tiles) for the wall surfaces surrounding the cooktop.
  • The cooktop will not be installed directly above a dishwasher, fridge, freezer, steam oven, washing machine or clothes dryer, as the humidity may damage the cooktop electronics.
  • The installation will comply with all regulations relating to the discharge of air, clearance requirements and other applicable standards and regulations.
  • You consult local building authorities and by-laws if in doubt regarding installation.
  • The installation will comply with all regulations relating to the discharge of air.
DURING INSTALLATION

Please ensure the following:

  • Flush mounting or sealing this appliance into the bench with silicone or glue may make future servicing difficult. Fisher & Paykel will not be liable for any costs associated with removing or replacing a sealed-in appliance, nor for repairing any damage that may be incurred by doing this.

  • Seal exposed bare edges of the cutout with an oil-based paint or moisture-proof polyurethane to prevent possible moisture creeping between the cooktop trim and
    the benchtop.

  • Take extreme care not to chip, crack, or break the top glass surfaces during installation.

  • A heavy metal tool or part accidentally dropped on the glass could damage it.

  • If, after following the instructions given, correct performance cannot be achieved, please contact your nearest Fisher & Paykel Authorised Service Centre, Customer Care, or contact us through our local website listed at the end of this document.
    WARNING!

  • The owner carries all risk for flush mounting the cooktop. The owner must ensure the cooktop has been cut out from the countertop before servicing can be carried out.
    Fisher & Paykel will not be liable for any costs associated with removing or replacing a flush-mounted and/or sealed-in product, nor for repairing any damage that may be incurred by doing this.

TOOLS AND COMPONENTS

PARTS SUPPLIED
  • Keep all packing materials until the unit has been inspected.
  • Inspect the product to ensure there is no shipping damage. If any damage is detected contact the dealer or retailer you bought the product from to report the damage.
  • Fisher & Paykel is not responsible for shipping damage.FISHER-PAYKEL-CID834DTB4-Downdraft-Induction-Cooktop-fig1

COMPONENTS REQUIREDFISHER-PAYKEL-CID834DTB4-Downdraft-Induction-Cooktop-
fig2

OPTIONAL ACCESSORY KITS
  • Product can be vented to an external wall at the rear using supplied components**. The below accessory kits can be purchased separately to expand venting options.
  • To purchase accessory kits, visit fisherpaykel.comFISHER-PAYKEL-CID834DTB4-Downdraft-Induction-Cooktop-fig3

DIMENSIONS

PRODUCT DIMENSIONS

FISHER-PAYKEL-CID834DTB4-Downdraft-Induction-Cooktop-
fig4

PRODUCT DIMENSIONS MM

A Overall height of cooktop 217
B Overall width of cooktop 830
C Overall depth of cooktop* 525
D Depth of cooktop surface 515
E Height of chassis 50
F Width of chassis 794
G Depth of chassis 488
H Depth of front overhang of cooktop glass** 14
I Depth of rear overhang of cooktop glass** 14
J Depth of left overhang of cooktop glass** 18
K Depth of right overhang of cooktop glass** 18
L Height of venting*** 170 – 1067
M Height of venting outlet 94
N Width of venting outlet 226
O Depth of ducting 94
P Minimum clearance below cooktop 200
ACCESSORY DIMENSIONS

FISHER-PAYKEL-CID834DTB4-Downdraft-Induction-
Cooktop-fig5

CUTOUT

PROUD INSTALLATIONFISHER-PAYKEL-CID834DTB4-Downdraft-Induction-Cooktop-
fig6

FLUSH INSTALLATION

CUTOUT DIMENSIONS MM CUTOUT DIMENSIONS MM
A Overall width of cutout 807 A Overall width of routered recess 835
B Overall depth of cutout 492 B Overall depth of routered recess 520
C Minimum depth at rear 50 C Overall width of cutout 807
D Corner radius of cutout max 10 D Overall depth of cutout 492
E Minimum depth at rear 50
F Corner radius of routered recess 4.5
G Corner radius of cutout max 10

CLEARANCES

FISHER-PAYKEL-CID834DTB4-Downdraft-Induction-Cooktop-
fig8FISHER-PAYKEL-CID834DTB4-Downdraft-
Induction-Cooktop-fig29

  • Combustible surface definition: any materials of a building structure or decorative structure made of wood, compressed paper, plant fibres, vinyl/plastic or other materials that are capable of transferring heat or being ignited and burned. Such material shall be considered combustible even though flame-proofed, fire-retardant treated or surface-painted, or plastered.
  • From underside of cooktop glass. Required for cleaning access.
  • Refer to venting preparation for more information.

VENTING PREPARATION

FISHER-PAYKEL-CID834DTB4-Downdraft-Induction-Cooktop-
fig9

VENTING TO THE REAR

Through same cabinetry

  • This can be acheived using the supplied components. When ducting is centred below cooktop, a maximum venting height of 1067mm* is possible, alongside a maximum venting depth of 93mm*. These distances can be extended by using accessory kit D1-C-222-89. When ducting is directly below the outlet, a maximum venting height of 847mm is possible, alongside a maximum venting depth of 93mm.
  • A space of 105mm is required at the rear of the cabinetry to house the vertical ducting components**. Alternately, if vertical ducting is to pass through any shelving, ensure a cutout of 232mm x 100mm has been created in all shelves.
  • Every 3m or additional bend drops extraction performance by 2%.

Through adjacent cabinetry

  • This can be achieved through the use of a minimum of 2x E90-H-222-89 and 1x D1-C-222-89 accessory kits.
  • A space of 105mm is required at the rear of the cabinetry to house the vertical ducting components**. Alternately, if vertical ducting is to pass through any shelving, ensure a cutout of 232mm x 100mm has been created in all shelves.
  • Every 3m or additional bend drops extraction performance by 2%.

Through sub-floor

  • This can be acheived using the supplied components with a maximum venting height of 712mm* possible.
  • A space of 105mm is required at the rear of the cabinetry to house the vertical ducting components**. Alternately, if vertical ducting is to pass through any shelving, ensure a cutout of 232mm x 100mm has been created in all shelves.
  • Every 3m or additional bend drops extraction performance by 2%.

Direct from outlet’

  • This can be achieved through the use of a D1-C-222-89 accessory kit.
  • When venting directly back from the outlet, the top of the ducting will sit 80mm below the cooktop glass.
  • Every 3m or additional bend drops extraction performance by 2%.
VENTING TO THE SIDE
  • This can be achieved through the use of a minimum of 2x E90-H-222-89 and 1x D1-C-222-89 accessory kits and can be configured via the front or the rear.
  • A space of 105mm is required at the rear of the cabinetry to house the vertical ducting components**. Alternately, if vertical ducting is to pass through any shelving, ensure a cutout of 232mm x 100mm has been created in all shelves.
  • Access through the base of the cabinetry to connect ducting components is recommended.
  • Every 3m or additional bend drops extraction performance by 2%.

From underside of glass to base of outlet
When vertical ducting is housed within cabinetry only
From rear edge of glass to end of duct

ELECTRICAL CONNECTION

CONNECTION LOCATION

Before connecting the cooktop to the mains power supply check that:

  • The domestic wiring system is suitable for the power drawn by the cooktop.
  • The voltage corresponds to the value given in the rating plate.
  • The power supply cable sections can withstand the load specified on the rating plate.

FISHER-PAYKEL-CID834DTB4-Downdraft-Induction-Cooktop-
fig10

CONNECT POWER

  1. Open the junction box cover and connect the wiring to the terminal block.

SINGLE-PHASE CONNECTIONFISHER-PAYKEL-CID834DTB4-Downdraft-Induction-
Cooktop-fig12 TWO-PHASE CONNECTION FISHER-PAYKEL-CID834DTB4-Downdraft-Induction-Cooktop-
fig13 THREE-PHASE CONNECTION FISHER-PAYKEL-CID834DTB4-Downdraft-Induction-Cooktop-
fig14

INSTALL DUCTING
  1. Fit the 90° elbow to the cooktop outlet. Tape to secure.
    If ducting direct from the outlet, the 90º elbow is not required however the connector from accessory kit D1-C-222-89 must be used.

  2. Cut all other ducting to required lengths and slot together. Tape to secure.

CUSTOM DUCTING

If using custom ducting, refer to the cooktop outlet dimensions below. To connect cooktop to round ducting, accessory kit DA-219-98-150 can be purchased separately.FISHER-PAYKEL-CID834DTB4-Downdraft-Induction-Cooktop-
fig17

OPTIONAL RECIRCULATION KIT*
  1. Accessory kit KRCID834 can be purchased separately to allow for recirculated venting.FISHER-PAYKEL-CID834DTB4-Downdraft-Induction-Cooktop-fig18

INSTALL COOKTOP – PROUD

  1. Turn the cooktop upside down on a protective cover.

  2. Apply adhesive foam seal around the glass overhang, 5mm from the edge of the glass.
    Ensure the adhesive side facing is down to form a continuous seal around the cooktop.

  3. Trim the excess sealing material using a sharp cutter or trimmer knife.
    Take care not to damage the benchtop.

  4. Attach the four side clips to the cooktop chassis.
    Ensure the clips are oriented correctly.

  5. Align vertical ducting to the elbow on the cooktop before lowering it into the cutout.
    Tape the ducting to secure.

INSTALL COOKTOP – FLUSH

  1. Prepare the countertop for flush installation. Use a router to cutout the edges of the countertop to specified depth (5mm). Ensure all bare edges are sealed. Refer to
    ‘Installation Considerations’.
    Attach an adhesive tape along  the edges of the routered recess.

  2. Attach the four side clips to the cooktop chassis.
    Ensure the clips are oriented correctly.

  3. Align vertical ducting to the elbow on the cooktop before lowering it into the cutout.
    Tape the ducting to secure.

  4. Apply silicone in the gap between countertop and cooktop.
    Wipe off any excess silicone.

INSTALLER CHECKLIST

TO BE COMPLETED BY THE INSTALLER GENERAL

  • Read safety and warnings in the user guide before operating the cooktop.
  • Specified clearance maintained.
  • Unit is level – front to back and side to side.
  • All packaging materials have been removed.
  • Touch controls and displays are functioning.
  • Cooking zones are functioning correctly. Turn on all of them to a high setting and leave them on for at least one minute.
  • There is a constant flow of cool air from the cabinetry to the base of the cooktop.
  • Cooktop is securely clamped.
  • Basic operation has been demonstrated to the customer.

VENTILATION

  • Ensure all ducting components are taped securely.
  • Check outlets are clear and not obstructed.

ELECTRICAL

  • Receptacle with correctly rated over-current protection is provided for service cord connection.
  • Adequate ground connection.
  • Power supply cable is not touching the cooktop and accessible.

Complete and keep for safe reference:

  • Model
  • Serial No.
  • Purchase Date
  • Purchaser
  • Dealer Address
  • Installer’s Name
  • Installer’s Signature
  • Installation Company
  • Installation Date

FISHERPAYKEL.COM
© Fisher & Paykel Appliances 2021. All rights reserved.
The models shown in this guide may not be available in all markets
and are subject to change at any time.
The product specifications in this guide apply to the specific products and models described at the date of issue. Under our policy of continuous product improvement, these specifications may change at any time.
For current details about model and specification availability in your country, please go to our website or contact your local Fisher & Paykel dealer.
592356A 05.21

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Fisher & Paykel User Manuals

Related Manuals