MOXA UC-8112-ME-T Series Computing Platform Installation Guide
- June 5, 2024
- MOXA
Table of Contents
- MOXA UC-8112-ME-T Series Computing Platform
- Overview
- Package Checklist
- LED Indicators
- Installing the UC-8112-ME-T
- Wall Mounting (optional)
- Connector Description
- SD/SIM Card Sockets
- Accessing the UC-8112-ME-T Using a PC
- C1D2 Specifications
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
MOXA UC-8112-ME-T Series Computing Platform
Overview
The UC-8112-ME-T computing platform is designed for embedded data acquisition applications. The UC-8112-ME-T computer comes with one or two RS-232/422/485 serial ports and dual 10/100 Mbps Ethernet LAN ports, as well as a Mini PCIe socket to support cellular modules. These versatile communication capabilities let users efficiently adapt the UC-8112-ME-T to a variety of complex communications solutions.
Package Checklist
Before installing the UC-8112-ME-T, verify that the package contains the following items:
- UC-8112-ME-T embedded computer
- Power jack
- 3-pin terminal block for power
- 5-pin terminal block for UART x 2
- Quick installation guide (printed)
- Warranty card
IMPORTANT: Notify your sales representative if any of the above items are missing or damaged.
UC-8112-ME-T Panel Layout
The following figures show the panel layouts of the UC-8112-ME-T Top Panel
Top Panel View
Bottom Panel View
Front Panel View
LED Indicators
LED Name | Color | Function |
---|---|---|
**** | **** |
USB
| ****
Green
| Steady On| USB device is connected and
working normally.
Off| USB device is not connected.
|
SD
| ****
Green
| Steady On| SD Card inserted and working normally.
Off| SD card is not detected.
|
Power
| Green| Power is on and the computer is working
normally.
Off| Power is off.
| ****
LAN1/ LAN 2 (RJ45
connector)
| Green| Steady On| 100 Mbps Ethernet link
Blinking| Data transmission in progress
Yellow| Steady On| 10 Mbps Ethernet link
Blinking| Data transmission in progress
Off| Ethernet is not connected.
LED Name| Color| Function
---|---|---
|
Wireless Signal Strength
| ****
Green Yellow Red
| The number of glowing LEDs indicates the signal strength.
3 (Green + Yellow + Red): Excellent 2 (Yellow + Red): Good
1 (Red): Poor
Off| Wireless module is not detected.
| Programm able diagnostic LEDs|
Green Yellow Red
| These three LEDs are programmable. For details, refer to the “ Default Programmable Button Operation ” section in the Hardware User’s Manual.
Installing the UC-8112-ME-T
Two sliders are provided at the back of the unit for DIN-rail mounting or wall
mounting.
DIN-Rail Mounting
- The DIN-rail mounting kit is mounted by default as shown in the figure below:
- Pull down the bottom slider of the DIN-rail bracket located at the back of the unit
- Insert the top of the DIN rail into the slot just below the upper hook of the DIN-rail bracket.
- Latch the unit firmly on to the DIN rail as shown in the illustrations below.
- Push the slider back into place.
Wall Mounting (optional)
- Remove the four screws on the side-panel silver cover of the device.
- Place the wall-mount brackets on the silver cover and fasten the screws as shown below. Use only the screws provided in the wall-mounting kit package.
ATTENTION: The wall-mounting kit is not included in the package and must be purchased separately.
Connector Description
Power Connector
Connect the power jack (in the package) to the UC-8112-ME-T’s DC terminal
block (located on the top panel), and then connect the power adapter. It takes
about 30 seconds for the system to boot up. Once the system is ready, the
Power LED will light up.
WARNING EXPLOSION HAZARD!
Do not disconnect equipment unless the power has been removed or the area is
known to be non-hazardous.
Grounding the UC-8112-ME-T
Grounding and wire routing help limit the effects of noise due to
electromagnetic interference (EMI). SG: The Shielded Ground (sometimes
called Protected Ground) contact is the top contact of the 3-pin power
terminal block connector when viewed from the angle shown here. Connect the SG
wire to an appropriate grounded metal surface.
Ethernet Ports
The two 10/100 Mbps Ethernet ports (LAN 1 and LAN 2) use RJ45 connectors.
Pin | Signal |
---|---|
1 | ETx+ |
2 | ETx- |
3 | ERx+ |
6 | ERx- |
Serial Ports
The two serial ports (P1 and P2) use terminal connectors. Each port can be
configured by software for RS-232, RS-422, or RS-485. The pin assignments for
the ports are shown in the following table:
Pin | RS-232 | RS-422 | RS-485 |
---|---|---|---|
1 | TXD | TXD+ | – |
2 | RXD | TXD- | – |
3 | RTS | RXD+ | D+ |
4 | CTS | RXD- | D- |
5 | GND | GND | GND |
SD/SIM Card Sockets
The UC-8112-ME-T comes with an SD socket for storage expansion, and a SIM card socket for cellular communication. The SD card/SIM card sockets are located at the lower part on the front panel. To install thecards, remove the screw and the protection cover to access the sockets, and then insert the SD card or the SIM card into the sockets directly. You will hear a click when the cards are in place. To remove the cards, push the cards in before releasing them.
Console Port
The console port is an RS-232 port that can be connected to with a 4-pin pin
header cable. You can use this port for debugging or firmware upgrade. Note
that the cable is not included in the package.
USB
The USB 2.0 port is located at the lower part of the front panel and supports
a USB storage device driver. By default, the USB storage is mounted at
/mnt/usbstorage.
Real-time Clock
The real-time clock in the UC-8112-ME is powered by a lithium battery. We
strongly recommend that you do not replace the lithium battery without the
help of a Moxa support engineer. If you need to change the battery, contact
the Moxa RMA service team.
ATTENTION: There is a risk of explosion if the battery is replaced with an incorrect type of battery.
Cellular Module
The UC-8112-ME-T comes with a built-in PCIe socket for wireless communication.
To install a cellular module, do the following:
- Remove the four screws on the DIN-rail mounting bracket and detach the bracket from the unit.
- Remove the two screws on the rear panel.
- Remove the four screws on the silver cover on the right panel and remove the cover.
- Remove the screw on the metal cover.
- Remove the three screws on the top panel.
- Remove the two screws on the bottom panel.
- Check the contents of the cellular module package. The package should contain the items shown below:
- Remove the metal cover of the computer and locate the cellular module socket.
- Remove the screw next to the socket and replace it with the bronze screw (in the package) as shown below:
- Attach one thermal pad to the cellular module cover and the other thermal pad to the module pad.
- Attach the cellular module to the module pad.
- Mount the module cover on the cellular module and use screws on both sides to secure the cover.
- Insert the module into the socket and secure it using a screw from the package.
- Connect antenna cables to the cellular module. There are three antenna connectors on the cellular module: W1 and W3 are for cellular antennas and W2 is for GPS antenna.
- Insert the antenna connectors through the antenna cable holes on the front panel of the cover as shown below:
- Secure the antenna connectors to the cover using a locking washer and nut as shown below:
- Arrange the antenna cables and use a cable tie to attach the cables to the bronze screw. You may cut the cable tie if it is too long.
- Plug the antenna onto the connector.
- Replace the cover of the computer and fasten the screws to secure the cover.
Accessing the UC-8112-ME-T Using a PC
You can use a PC to access the UC-8112-ME-T by one of the following methods:
- Through the serial console port with the following settings:Baudrate=115200 bps, Parity=None, Data bits=8, Stop bits =1, Flow Control=None
- Using SSH over the network. Refer to the following IP addresses and login information
Default IP Address | Netmask | |
---|---|---|
LAN 1 | 192.168.3.127 | 255.255.255.0 |
LAN 2 | 192.168.4.127 | 255.255.255.0 |
Login: moxa
Password: moxa
ATTENTION: These devices are open-type devices that are to be installed in an enclosure with a tool removable cover or door, suitable for the environment. This equipment is suitable for use in Class I, Division 2, Groups A, B, C, and D or in non-hazardous locations only.
WARNING: The GPS antenna connection is not to be used in hazardous locations.
C1D2 Specifications
- Temperature Code (T-code): T4
- Max Ambient: 85°C
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>