Functional Description

The demonstration board AMB-DB2 allows for the establishment of a wireless connection between wireless devices within a very short time. Moreover, the AMB-DB2 board provides easy connection to a computer or to an external processor. The EV kit is suitable for the commissioning of AMB2720, AMB2730, AMBZ420, AMBZ430 and AMB2620. The radio module can be addressed directly from the computer, using the Windows program
“AMBER Commander”.
The development board can be connected either directly to the USB interface of a PC or to any other microcontroller system. For this purpose, there are several pin headers to which all signals of the module are connected besides of to the antenna connection.

 Scope of Delivery

The AMB8425-M-EV kit is delivered in a product case and comprises:

  •  2 x development board AMB-DB2 with mounted wireless module
  •  2 x USB data cable 1.8m

The Demonstration Board

AMBER-WIRELESS-AMB-DB2-Demonstration-
Board-1

Overview

AMBER-WIRELESS-AMB-DB2-Demonstration-
Board-2 AMBER-WIRELESS-AMB-DB2-Demonstration-
Board-3

Power Supply

Power Adapter / Power Jack
The development board can be operated by connecting a 5 V power source to the power jack.

If the power supply is connected and the bridge on P6 is set to “DC”, the power LED will be active. It is also possible to supply the board via USB- Interface. To do this, switch P6 to “USB”. Then the 5V of the USB-Interface is used to supply the board. Power can also be supplied to the module via P7 pin2 (2.0 V – 3.6 V). However, in this case the USB converter will not be powered.
JP3 / Current Measurement
By default, P7 is closed for operation. If a current meter is connected instead of the jumper, the power consumption of the radio module can be measured here. If the meter is not attached and the bridge is not set, the module will not receive any supply voltage. However, the power LED is active, as it is connected upstream of the current measurement bridge in order not to distort the module’s power consumption.

 Interfaces

UART / USBAMBER-WIRELESS-AMB-DB2-Demonstration-
Board-5
The UART of the module can be connected to the USB converter by setting the jumper on P8 and P9 to UART and the jumper on P10 (Pin 13-14 and Pin 15-16). In this case, the module can be connected directly to a PC via USB cable. If the FTDI-driver is used, the PC will show you a virtual COM-Port to communicate with the module.

UART / TTL
If a microcontroller is to be connected to the module, remove the jumper on P10. The UART can be accessed directly on the pin bar to which all other pins of the module are connected.

Watch the level compatibility. When powered over the power jack or USB (section 3.2.1), the levels of the module are 3.3 V. If the power supply is provided by P7 pin 2 (section 3.2.1), the levels of the module can be adjusted in the range from 2.0 to 3.6 V.

Reset

On the development board, there is a “RESET” button by means of which the module can be reset. Moreover, the reset is available on pin 27.

 Schematic of AMB-DB2

Using the AMB-DB2 with different RF modules

For detailed description of the modules refer to the corresponding data sheets and manuals.
AMB2720
Place jumper on P12, P13 and P14 to set the module in normal operating mode and connect Pin 10 to GND.
AMB2730
Place jumper on P12, P13 and P14 to set the module in normal operating mode and connect Pin 10 to GND.
AMBZ420
Connect Pin 10 to GND to select UART interface Connect Pin 13 to 3V3 to select the watch crystal
AMBZ430
Connect Pin 10 to GND to select UART interface Connect Pin 13 to 3V3 to select the watch crystal
AMB2620
Place jumper on P11 and switch P8 / P9 to “USB”.

Important Notes

Disclaimer of liability
AMBER wireless GmbH believes the information contained herein is correct and accurate at the time of this printing. However, AMBER wireless GmbH reserves the right to change the technical specifications or functions of its products, or to discontinue the manufacture of any of its products or to discontinue the support of any of its products, without any written announcement and urges its customers to ensure, that the information at their disposal is valid. AMBER wireless GmbH does not assume any responsibility for the use of the described products, neither does it convey any license under its patent rights, or its other intellectual property rights, or any third party rights. It is the customer’s responsibility to ensure that his system or his device, in which AMBER wireless products are integrated, complies with all applicable regulations.
Trademarks

  • AMBER wireless® is a registered trademark owned by AMBER wireless GmbH
  •  Windows is a registered trademark of the Microsoft Corporation

All other trademarks, registered trademarks and product names are the sole property of their respective owners.
Limitation of use
AMBER wireless products are not authorized for use in life support appliances, devices, or other systems where malfunction can reasonably be expected to result in significant personal injury to the user, or as a critical component in any life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. AMBER wireless GmbH customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify AMBER wireless GmbH for any damages resulting from any improper use or sale. The use of AMBER wireless products commits the user to the terms and conditions set out herein.
E-Mail info@amber-wireless.de Internet http://www .amber-wireless.de

Tel. +49 2203 98019 0

Fax +49 2203 98019 25

Albin-Koebis-Strasse 18 51147 Cologne, Germany

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals