IMPORTANT SAFETY INSTRUCTIONS]
READ AND FOLLOW ALL INSTRUCTIONS
WARNING – RISK OF ELECTRIC SHOCK
The pump is to be supplied by an isolating transformer or supplied through
a residual current device (RCD) having a rated residual operating current not
exceeding 30 mm. The power source on the wall of the building should keep more
than 4m away from the pool and at a height of 1.2m at least. The appliance
must be supplied by the earthed power source. Extension cords can’t be used.
The pump cannot be using while people are inside the pool. Forbid the access of the pool in case of damage of the filter pump.
DO NOT BURY THE CORD. Locate cord to minimize abuse from lawnmowers, hedge trimmers, and other equipment.
WARNING – If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons in order to avoid a hazard.
CAUTION – This pump is for use with storable pools only. Do not use with permanently-installed pools. A storable pool is constructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity. A permanently-installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for storage.
IMPORTANT – Using the pump with an unmatched electrical supply is dangerous and will result in catastrophic failure of the pump.
RISK OF ELECTRICAL SHOCK – When working with electricity, turn the
electrical power off at the circuit breaker and lock the breaker door. Failure
to do so will result in an increased risk of shock, injury, and possibly
death.
DO NOT REMOVE THE GROUNDING PRONG OR MODIFY THE PLUG IN ANY WAY. DO NOT USE
ADAPTOR PLUGS. Consult a qualified electrician for any questions related to
the validity of your plug grounding.]}
Handle the pump with care. Do not pull or carry the pump by the power cord.
Never pull a plug from the outlet by yanking the power cord. Keep cord free
from abrasions. Sharp objects, oil, moving parts, and heat should never be
exposed to the filter pump.
WARNING – This appliance can be used by children aged 8 years and above
and persons with reduced physical, sensory or mental capabilities or lack of
experience and knowledge if they have been given supervision or instruction
concerning use of the appliance in a safe way and understand the hazards
involved. Children shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without supervision. (For EU market)
WARNING – This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for their
safety. Children should be supervised to ensure that they do not play with the
appliance.
(For market other than EU)
Cleaning and user maintenance must be performed by an adult above 18 years old
who is familiar with the risk of electric shock. When the appliance will be
not used for a long time, such as in the winter, the pool set should be
disassembled and stored indoors.
CAUTION – Read the instruction before using the appliance and
installation/reassembly every time.
The appliance must be placed more than 2m away from the pool. Electric
installations should follow national wiring rules. Consult a qualified
electrician for any questions.
Only the media provided or specified by the manufacturer is to be used with
product installation.
It is essential to check that the suction openings are not obstructed.
It is advisable to stop the filtration during maintenance operations on the
filtration system.
Regularly monitor the filter clogging level.
A weekly check is recommended for cleaning.
Minimum daily filtration operating time of 8 hours is recommended to ensure
clear pool water.
It is essential to change any damaged element or set of elements as soon as
possible. Use only parts approved by the person responsible for placing the
product on the market.
All filters and filter media shall be inspected regularly to ensure that there
is not a build-up of detritus thus preventing good filtration. The disposal of
any used filter media should also be in accordance with applicable
regulations/legislation. In case of doubt on the pump or any circulation
devices, contact a qualified installer, or the
manufacturer/importer/distributor. The water circulation installation shall
comply with the European as well as national/local regulations, especially
when dealing with electrical issues. Any change of valve position, pump size,
grille size can cause a change of the flow and the suction velocity can be
increased. Mind all the safety requirements and recommendations described in
the manual
NOTE:
Please examine equipment before use. Notify Bestway at the customer service
address listed on this manual for any manufacturing defect or missing parts at
the time of purchase. Verify that the equipment components represent the
filter pump model that you had intended to purchase.
NOTE:
Place pump on solid and level ground. Pay attention to the position of the
pool and pump so adequate ventilation, drainage, and access for cleaning is
available. Never place a pump in an area that may accumulate water, or in an
area where foot traffic will flow around the pool. It is necessary to have the
plug accessible after the installation of the pool.
NOTE:
Atmospheric conditions may affect the performance and life span of your
filter pump. Unnecessary wear and tear may occur during periods of cold, heat
and exposure to sun. Whenever possible shelter pump from these conditions. It
is important to ensure the factory-equipped stopper plugs for the inlet and
outlet ports replace the screens before removal or maintenance on the pump is
attempted.
NOTE:
- Do not add chemicals in the filter pump.
- Don’t plug or unplug the appliance if hand is wet.
- Always unplug the appliance:
- On raining days
- Before cleaning or other maintenance
- Leave it unattended on holidays Safekeeping the instruction. For reconstruction the pool set every time, please always refer to the instructions.
- – If the instruction is missed, please contact with Bestway or search it in the website: www.bestwaycorp.com
NOTE: This product is not intended for commercial use.
Please read the instruction manual carefully and keep it for future reference.
SAVE THESE INSTRUCTIONS.
PEDESTAL FIXING
The filter pump must be vertically fixed on the ground or a certain pedestal
made of wood or concrete before use. There should be two holes 7mm in diameter
on the pedestal, the space between which should be 256mm. Put filter pump on
the pedestal and fix them together by fastening the bolts and nuts. All the
pedestal parts should weigh over 18kgs at least to prevent the pump from
accidentally falling.
NOTE: It is imperative to check that the hydraulic connectors are not obturated.
OPERATION
- Open/unscrew the Air Purge Valve on the top of the Filter Pump; air is released as water fills the Filter Pump.
- When water comes out of the Air Purge Valve screw it closed and wipe away any water.
- To start the Filter Pump, insert the plug into a residual current device (RCD).
- To start the Filter Pump, insert the plug into a circuit of alternative residual power (DDR) For France Only.
- Turn on the switch to the “I” position.
IMPORTANT: DO NOT DRY RUN THE FILTER PUMP –
Make sure both the pool’s Inlet and Outlet valves are fully covered by water
before operating the Filter Pump.
PUMP MAINTENANCE
CAUTION: YOU MUST ENSURE THE FILTER PUMP IS UNPLUGGED BEFORE ANY MAINTENANCE BEGINS OR SEVERE RISK OF INJURY OR DEATH EXISTS.
- Unplug the Filter Pump.
- Stop water flowing to the Filter Pump refer to pool’s manual.
- Unscrew the Filter Cap Retainer and remove the Filter Cap.
- Clean the Filter Cartridge with a garden hose.
- Insert the cleaned (or new) Filter Cartridge; ensure it is centered in the Filter Pump.
- Check that the Filter Cap Seal is in place.
- Replace the Filter Cap and screw the Filter Cap Retainer into position.
- Open the valve A and B.
- Follow the Pump Installation Directions section to prepare the system for use.
IMPORTANT: For sanitary reasons, we suggest replacing the Filter Cartridge with a new one every two weeks. Flush the filter daily.
PUMP STORAGE
- Unplug the Filter Pump.
- Stop water flowing into the Filter Pump and to remove the Filter Cartridge.
- Discard the Filter Cartridge.
- Detach all Hoses.
- Dry all components thoroughly.
- Store the filter pump in a dry location out of the child’s reach. Storage temperature: 4-40 °C(39,2-104 F)
- Drain the pool according to the Pool Owner’s Manual.
PUMP WARRANTY
For information concerning pump warranty please visit our website at: www.bestwaycorp.com PUMP DISPOSAL
Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your local authority or retailer for recycling advice.