Product Illustration
The product is an LED bulb of high performance. You may use a remote control to power ON/OFF the light or adjust the brightness and color temperature wirelessly. The electricity consumption is only 20% of traditional incandescent bulbs, with the lifespan being 10 times longer than energy-saving bulbs. It features night light, full bright light and light brightness functions. Utilizing 2.4G high-frequency wireless transmission technology, the bulb consumes little power, transmits signals over a long distance, resists interference powerfully, and communicates with the remote control at high speeds. It’s a perfect fit for your sitting room, kitchen, hallway as well as other places installed with E27/E26/B22 bulb sockets.
Product Dimensions
Specification
Power | 7W |
---|---|
Input Voltage | 100-240V AC |
Socket | E26/E27 |
Beam Angle | 200° |
Color Temperature | 3000K-6000K |
Brightness Range | 2%-100% |
Luminous Flux | 700Im |
Life Span | 20000hrs |
Communication Protocol | 2.4G |
Buttons on Remote Control
1 | All Light ON(Long press to adjust all lights to maximal brightness) |
---|---|
2 | Indicator |
3 | Warm Light Adjustment |
4 | Grouping ON (Long press to adjust the correspondent light to maximal |
brightness)
5| All Light OFF (Long press to adjust all lights to night light mode)
6| Brightness +
7| Cold Light Adjustment
8| Brightness –
9| Grouping OFF (Long press to adjust the correspondent light to night light
mode)
Functions Usage
Group Match: To group and pair the LED bulb with the remote control, please follow the steps below:
Install the LED bulb to the bulb socket. Light up the bulb that needs to be
grouped after you connect the power supply. Cut off power for 1 Os and then
connect the power source again. Press the “ON” button in the correspondent
group in 3s after connecting the power source. The LED bulb will “flash for 3
times slowly” to indicate successful grouping. Repeat the steps stated above
to group the different bulbs into different groups.
Note: Each LED bulb can only be paired with a specific group on one
remote control. Each group on the remote control can be paired with unlimited
number of bulbs. Each LED bulb can only be paired with 4 remote controls.
Unpair and Regroup: If there’s any changes in the bulbs layout or you need to rearrange the groups you’ve divided the bulbs into, please clear the groups you’ve assigned to the LED bulbs. The steps to do so are as below:
Light up the LED bulb that needs to be excluded from a group on the remote
control. Press the “All Light On” button or the “ON” button of the
correspondent group in 3s for 5 effective times after you connect the power
source. The bulb will flash for 5 times quickly to indicate that it is
unpaired with the remote control successfully. To regroup the LED bulb after
disconnecting it with the remote control, you may follow the exactly same
steps stated in the “Group Match”.
Note: The pairing with different LED bulbs must be done in groups, while
the disconnection of different bulbs can be done either in groups or all at
once. To disconnect the bulbs with the remote control all at once, please
follow the steps below: Cut off the power source and wait for 10s to reconnect
the power source. Press the “All Light On” button for 5 effective times in 3s
for 5 effective times after you connect the power source. All lights will
flash for 5 times quickly to indicate that all bulbs are disconnected with the
remote control successfully.
Night Light and Brightest Mode
Night Light Mode: Long press the “All Light OFF” button under any mode when
the power source is connected. All lights will be switched to night light mode
then. Long press the “Grouping OFF” button to adjust the bulbs in
correspondent group to the night light mode. The maximal brightness for night
light mode is 1%o.
Brightest Mode: Long press the “All Light ON” button when the power source is connected to adjust all bulbs to the brightest mode. Long press the “Grouping ON” button to adjust the bulbs in correspondent group to the brightest mode.
Notes:
- The bulb supply voltage should be AC100 – 240V. Other voltages out of this range may damage the bulb.
- Make sure the bulb head corresponds to the socket type before installation. Do not operate when power source is connected.
- Do not place remote control inside large metal area or near strong magnetic field. Otherwise, communication distance can be severely disturbed.
FCC Warning Statement
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Service Center
Europe
F&M Technology GmbH
Tel: +49 341 5199 8410 (Working day 8 AM – 4 PM CET)
Fax: +49 341 5199 8413
Address: FraunhoferstraBe 7, 04178 Leipzig, Deutschland
North America
Inateck Technology Inc.
Tel: +1 (909) 698 7018 (Working day 9 AM – 5 PM PST)
Address: 2078 Francis St., Unit 14-02, Ontario, CA 91761, USA El Inateck
M it +81 06 7500 3304 T 547-0014 t13,MtA&STE;ERt1110 3 Tgl 10 # 11
Importer/Responsible Person:
Europe
F&M Technology GmbH FraunhoferstraBe 7, 04178 Leipzig, Deutschland
Tel: +49 341 5199 8410
UK
Inateck Technology (UK) Ltd. 95 High Street, Office B, Great Missenden, United
Kingdom, HP16 OAL
Tel: +44 20 3239 9869
Manufacturer
Shenzhen Licheng Technology Co., Ltd.
Address: Suite 2507, Block 11 in Tian An Cloud Park, Bantian Street, Longgang
District, Shenzhen, Guangdong, China