bond Y95870 31” Amara Springs Cascading Lily Pad Fountain Owner’s Manual

June 5, 2024
bond

bond-Y95870-31”-Amara-Springs-Cascading-Lily-Pad-Fountain-
LOGO

bond Y95870 31” Amara Springs Cascading Lily Pad Fountain

bond-Y95870-31”-Amara-Springs-Cascading-Lily-Pad-Fountain-
PRODUCT

SAFETY INFORMATION

Please read and understand this entire manual before attempting to assemble, operate or install the product.

  • Save these warnings and instructions for reference. Read all instructions before use.
  • Failure to follow warnings and instructions may result in injury or property damage.
  • Excessive weight or pressure on any of the fountain sections may cause it to fall. Keep pets, children, or anyone from sitting, leaning, or climbing on any of the fountain components.
  • While fountain is designed to operate as splash free as possible, some water splashing out of the fountain is inevitable. Place the fountain in a location where any splashing will not cause damage.
  • The National Electric Code requires that a ground fault circuit interrupter (GFCI) be used in the branch circuit supplying fountain pump and other pond equipment. Seek your electrical supplies dealer for this device.
  • Always keep the fountain working with sufficient water and clean of debris and dirt to ensure proper functioning of the pump.
  • If necessary, clean the fountain with a soft cloth and change the water frequently. Due to water evaporation, you may see a buildup of white residue on the fountain surface from mineral content in the water supply. To prevent such buildup, regularly clean the fountain with soap and water. Do not use any abrasive, which may damage the applied finish.
  • Use of water clarifier or algaecide of any kind will damage the paint in the fountain and will not be covered under the manufacturer’s warranty.
  • This fountain is intended for outdoor use only.
  • See the pump instructions for pump safety, maintenance, and warranty information.
  • The pump on your fountain has no user-serviceable parts. Only an authorized service representative should service the pump.
  • California Prop. 65 Warning: This product can expose you to chemicals including Lead and Lead Compounds, which are known to the state of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.

CAUTION

  1. Install the fountain pump correctly before operating it.

  2. DO NOT allow the pump to run dry.

  3. For fountains with multiple sections or attached decorations: If any of the fountain’s attached sections with electrical lights or components fall into the water located in fountain base, unplug the
    fountain and turn off circuit breaker before trying to put the fountain pieces back in place.

  4. If any leakage occurs around the pump housing, turn off the circuit breaker immediately and have the pump serviced by a registered technician.

  5. Do not operate the fountain if the pump has been dropped or has a damaged power cord or plug.

  6. If the plug or your wall receptacle gets wet due to water dripping down the power cord or for any other reason, do not remove the plug from the wall outlet until the circuit breaker is turned off.

  7. Always unplug the fountain pump and any other independent electrical accessories (e.g. lights) from the outlet when not in use and before cleaning or replacing parts.

  8. Disconnect the power cord from the outlet by holding the plug, not by pulling on the power cord.

  9. Do not expose the pump to direct sunlight or to low temperatures for any period of time.

  10. Keep the power cord away from high temperatures or heat sources.

  11. This fountain pump is not intended for commercial use.

NOTE: Allow the pump power cord to hang at a lower level than the wall outlet to form a “drip loop”. This will help prevent water from dripping down the power cord and getting into the wall outlet.

PACKAGE CONTENTS

bond-Y95870-31”-Amara-Springs-Cascading-Lily-Pad-
Fountain-FIG1

ITEM DESCRIPTION QUANTITY
A Top fountain 1
B fッオョエ。ゥョ 「。ウ・ 1
C pオュー 1
D Decorative pebbles 1 bag
E Flexible water hose 1

PREPARATION

Before beginning assembly of product, make sure all parts are present. Compare parts with package contents list. If any part is missing or damaged, do not attempt to assemble the product.

Estimated Assembly Time: 10 minutes
No Tools Required for Assembly

ASSEMBLY INSTRUCTIONS

  1. Remove all packaging from all parts. Connect inside the fountain base (B).on the fountain base (B), being sure pump remains bond-Y95870-31”-Amara-Springs-Cascading-Lily-Pad-Fountain-FIG2
  2. Insert the electrical pump cable through the hole on the fountain base (B), being sure pump remains inside the fountain base (B).
  3. Set the top fountain (A) into place. Turn clockwise to lock with the fountain base.
  4. Pour the decorative pebbles (D) i nto the fountain evenly.
  5. Pour clean water into top of fountain, make sure the water pump (C) is fully submerged to prevent pump damage, 1 gallon (3.8 L) water is suitable.
  6. Plug electrical pump cable into outlet power supply.The flow rate can be increased or decreased by moving the flow rate controller onthe water pump to the +/- signs.

CAUTION: Be careful not to spill water onto the plug of the pump. DO NOT allow the pump to run dry!

OPERATING INSTRUCTIONS

While fountain is designed to operate as splash free as possible, some water splashing out of the fountain is inevitable. Place the fountain in a location where any splashing will not cause damage. Always keep the fountain working with sufficient water and clean of debris and dirt to ensure proper functioning of the pump.

Operating Fountain
ALWAYS MAKE SURE THE PUMP IS FULLY SUBMERGED UNDER THE WATERLINE PRIOR TO TURNING PUMP ON.

  1. Check that there is enough water in the reservoir.
  2. Plug in pump cord into outlet and switch on, pump will start to work.
  3. The water flow rate can be increased or decreased by moving the flow rate controller on the water pump to the +/- signs.
  4. Turn off power outlet switch, the pump will stop working.
  5. Unplug fountain from outlet if not in use for a long period of time.

Adjust the flow rate to achieve the desired effect and to minimize any splashing. Splashing can occur if the flow rate is too high or the reservoir is too full. The flow rate can be increased or decreased by moving the flow rate control switch towards the ‘+/max’ or ‘-/min’ positions.
Note:

  1. Drain the water if you don’t plan to use the fountain for a long time to prevent mosquito breeding and water odor.
  2. Be sure to drain all water during winter months or cold seasons to prevent reservoir from cracking or breaking.

bond-Y95870-31”-Amara-Springs-Cascading-Lily-Pad-Fountain-
FIG8

CARE AND MAINTENANCE

  • If necessary, clean the fountain with a soft cloth and change the water frequently. Due to water evaporation, you may see a buildup of white residue on the fountain surface from mineral content in the water supply. To prevent such buildup, regularly clean the fountain with soap and water. Do not use any abrasive, which may damage the applied finish.

  • Use of water clarifier or algaecide of any kind will damage the paint on the fountain and will not be covered under the manufacturer’s warranty.

  • Check regularly that the water reservoir has sufficient water to cover the pump at all times. It will be necessary to check more frequently in warm or windy weather.

  • Disconnect the power and empty the reservoir if the fountain will not be used for an extended time.

  • If installed outdoors and in a freeze-prone area of the country, ensure all water is removed and
    the unit is completely dry before temperatures drop too low. This product is NOT to be operated below 41°F or freeze damage may occur.

  • Store your product indoors during the winter months. Avoiding extreme cold temperatures will prevent from exposure damage.

  • Keep this manual for future reference.

bond-Y95870-31”-Amara-Springs-Cascading-Lily-Pad-Fountain-
FIG9

Model# Description Volt.      Power

YH-LV80C

| water pump|

120 V

|

6W

Frequency| Flow Height| Flow Volume
60 Hz|

70cm

| 390L/hour

NOTE: The pump data in this manual is from lab tests. The actual pump may be different due to the method of production or technical improvements. This data can be used as a reference when purchasing a similar pump.

TROUBLESHOOTING

Problem Solution

If the pump does not run

| Check the circuit breaker or try another outlet.
Check the water level in the fountain. Running the pump without suffi- cient water can damaged the pump.
Check the setting of the flow control on the pump and adjust the flow.
Check the pump discharge and intake for dirt and debris.

If hose is blocked.

| The pump might be “air locked.” Plug and unplug the pump several times to release the air inside the pump.
Check and reconnect the cord and try again.

WARRANTY

  • 1 Year warranty against manufacturer’s defect in materials & workmanship. The manufacturer warranty will be voided by, and manufacturer disclaims any responsibility for, the following actions:
  • Modification of the unit and/or components.
  • Use of any component part not manufactured or approved by the manufacturer.
  • Use and installation other than as instructed in this manual.
  • Please contact the manufacturer for replacement parts.

CUSTOMER SERVICE
If you have any questions or concerns, please contact Bond Manufacturing Co., Inc. at the below resources:

Toll Free Phone| 1-866-771-BOND (2663) | Monday – Friday, 8am – 4:30pm PST
---|---
Email| customer[email protected]
Online|

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>