Lenovo Intel S4500 Entry SATA 6Gb SSDs User Guide

June 3, 2024
Lenovo

Lenovo Intel S4500 Entry SATA 6Gb SSDs LOGO

Lenovo Intel S4500 Entry SATA 6Gb SSDs

Lenovo Intel S4500 Entry SATA 6Gb SSDs PRODUCTThe Intel S4500 Entry SATA solid-state drives (SSDs) for Lenovo servers use Intel 3D NAND TLC Flash Memory technology with a 6Gbps SATA interface to provide an affordable solution with industry leading performance. Compared with the Intel S3520 series, these new drives offer improved performance and lower latency. The S4500 SSDs are optimized for read-intensive applications such as boot, web servers, lower data rate operational databases and analytics.
Did you know?
By combining the latest Intel 3D NAND TLC Flash Memory technology with Intel’s latest controller technology, the design of the S4500 Entry SATA SSDs delivers consistent performance, reduced power consumption, and end-to-end data protection, as well as being optimized for IOPS/watt and cost/IOPS. Rigorous testing of S4500 Entry SATA SSDs by Lenovo through the Server Proven program assures a high degree of storage subsystem compatibility and reliability. Providing additional peace of mind, these drives are covered under Lenovo warranty.

Features

The Intel S4500 Entry SATA SSDs have the following features:

  • 2.5-inch or 3.5-inch form factors
  • Cost-effective Intel 3D NAND TLC Flash Memory
  • Endurance of 1 drive writes per day (DWPD) for 5 years, using Intel Standard Endurance Technology (SET).
  • SATA TLC solid-state drive with high read performance and consistently low latencies to fulfill client needs in the enterprise space
  • High reliability and enhanced ruggedness
  • Energy savings, with 5.6 W typical power consumption per drive
  • Absence of moving parts to reduce potential failure points in the server
  • S.M.A.R.T. support
  • Advanced Encrypting Standard (AES) 256-bit encryption
  • Full end-to-end data path protection
  • Thermal throttling to extend the life of the drive
  • Enhanced power loss data protection

SSDs have a huge but finite number of program/erase (P/E) cycles, which affect how long they can perform write operations and thus their life expectancy. Enterprise Entry SSDs typically have a better cost per read IOPS ratio but lower endurance and performance compared to Enterprise Performance SSDs. SSD write endurance is typically measured by the number of program/erase cycles that the drive can incur over its lifetime, which is listed as total bytes written (TBW) in the device specification. The TBW value that is assigned to a solid-state device is the total bytes of written data that a drive can be guaranteed to complete. Reaching this limit does not cause the drive to immediately fail; the TBW simply denotes the maximum number of writes that can be guaranteed. A solid-state device does not fail upon reaching the specified TBW. However, at some point after surpassing the TBW value (and based on manufacturing variance margins), the drive reaches the end-of-life point, at which time the drive goes into read-only mode. Because of such behavior, careful planning must be done to use SSDs in the application environments to ensure that the TBW of the drive is not exceeded before the required life expectancy. For example, the S4500 Entry 960 GB drive has an endurance of 1,860 TB of total bytes written (TBW). This means that for full operation over five years, write workload must be limited to no more than 1,019 GB of writes per day, which is equivalent to 1.1 full drive writes per day (DWPD). For the device to last three years, the drive write workload must be limited to no more than 1,699 GB of writes per day, which is equivalent to 1.8 full drive writes per day.

Technical specifications

The following table presents technical specifications for the Intel S4500 Entry SATA SSDs.
Technical specifications

Feature| 240 GB drive| 480 GB drive| 960 GB drive| 1.92 TB drive| 3.84 TB drive
---|---|---|---|---|---
Interface| 6 Gbps SATA| 6 Gbps SATA| 6 Gbps SATA| 6 Gbps SATA| 6 Gbps SATA
Capacity| 240 GB| 480 GB| 960 GB| 1.92 TB| 3.84 TB
Endurance (drive writes per day)| 1.42 DWPD| 1.03 DWPD| 1.06 DWPD| 1.06 DWPD| 1.09 DWPD
Endurance
(total bytes written)| 620 TB| 900 TB| 1.86 PB| 3.27 PB| 7.64 PB
Data reliability| < 1 in 1017
bits read| < 1 in 1017
bits read| < 1 in 1017
bits read| < 1 in 1017
bits read| < 1 in 1017
bits read
MTBF| 2,000,000
hours| 2,000,000
hours| 2,000,000
hours| 2,000,000
hours| 2,000,000
hours
IOPS reads (4 KB blocks)| 69,000| 72,000| 72,000| 72,000| 72,000
IOPS writes (4 KB blocks)| 16,000| 20,000| 30,000| 33,500| 33,000
Sequential read rate (128 KB blocks)| 500 MBps| 500 MBps| 500 MBps| 500 MBps| 500 MBps
Sequential write rate (128 KB blocks)| 190 MBps| 330 MBps| 490 MBps| 490 MBps| 470 MBps
Read latency (seq)| 36 µs| 36 µs| 36 µs| 36 µs| 36 µs
Write latency (seq)| 36 µs| 36 µs| 36 µs| 36 µs| 36 µs
Shock, operating| 1,000 G (Max)
at 0.5 ms| 1,000 G (Max)
at 0.5 ms| 1,000 G (Max)
at 0.5 ms| 1,000 G (Max)
at 0.5 ms| 1,000 G (Max)
at 0.5 ms
Vibration, operating| 2.17 GRMS (5-700 Hz)| 2.17 GRMS (5-700 Hz)| 2.17 GRMS (5-700 Hz)| 2.17 GRMS (5-700 Hz)| 2.17 GRMS (5-700 Hz)
Vibration, non-operating| 3.13 GRMS (5-800 Hz)| 3.13 GRMS (5-800 Hz)| 3.13 GRMS (5-800 Hz)| 3.13 GRMS (5-800 Hz)| 3.13 GRMS (5-800 Hz)
Typical power (Active Write Avg)| 2.6 W| 3.6 W| 4.8 W| 5.0 W| 5.6 W

Server support – ThinkSystem
The following tables list the ThinkSystem servers that are compatible.
Server support – ThinkSystem (Part 1 of 2)Lenovo Intel S4500 Entry SATA 6Gb
SSDs 01
Lenovo Intel S4500 Entry SATA 6Gb SSDs 02Server support – ThinkSystem (Part 2 of 2)
Lenovo Intel S4500 Entry SATA 6Gb SSDs 03

Server support – System x

The following tables list the System x servers that are compatible.
Support for System x and dense servers with Xeon E5/E7 v4 and E3 v5 processors
Support for System x and dense servers with Xeon E5/E7 v4 and E3 v5 processors

Part number| Descriptio| x3250 M6 (3943)| x3250 M6 (3633)| x3550 M5 (8869)| x3650 M5 (8871)| x3850 X6/x3950 X6 (6241, E7 v4)| nx360 M5 (5465, E5-2600 v4)| sd350 (5493)| nx360 M5 WCT (5467, E5-2600 v4)
---|---|---|---|---|---|---|---|---|---
2.5-inch drives with G3HS hot-swap tray
7SD7A05732| Intel S4500 240GB Enterprise Entry SATA G3HS 2.5″ SSD| Y| N| Y| Y| Y| Y| Y| N
7SD7A05731| Intel S4500 480GB Enterprise Entry SATA G3HS 2.5″ SSD| Y| N| Y| Y| Y| Y| Y| N
7SD7A05730| Intel S4500 960GB Enterprise Entry SATA G3HS 2.5″ SSD| Y| N| Y| Y| Y| Y| Y| N
4XB7A08493| Intel S4500 1.92TB Enterprise Entry SATA G3HS 2.5″ SSD| Y| N| Y| Y| Y| Y| Y| N
4XB7A08494| Intel S4500 3.84TB Enterprise Entry SATA G3HS 2.5″ SSD| Y| N| Y| Y| Y| Y| Y| N
3.5-inch drives with hot-swap tray
7SD7A05729| Intel S4500 240GB Enterprise Entry SATA HS 3.5″ SSD| Y| N| Y| Y| N| N| N| N
7SD7A05728| Intel S4500 480GB Enterprise Entry SATA HS 3.5″ SSD| Y| N| Y| Y| N| N| N| N
7SD7A05727| Intel S4500 960GB Enterprise Entry SATA HS 3.5″ SSD| Y| N| Y| Y| N| N| N| N
4XB7A08495| Intel S4500 1.92TB Enterprise Entry SATA HS 3.5″ SSD| Y| N| Y| Y| N| N| N| N
4XB7A08496| Intel S4500 3.84TB Enterprise Entry SATA HS 3.5″ SSD| Y| N| Y| Y| N| N| N| N
2.5-inch drives for NeXtScale
7SD7A05726| Intel S4500 240GB Enterprise Entry SATA 2.5″ SSD for NeXtScale| N| N| N| N| N| Y| N| Y
7SD7A05725| Intel S4500 480GB Enterprise Entry SATA 2.5″ SSD for NeXtScale| N| N| N| N| N| Y| N| Y
7SD7A05724| Intel S4500 960GB Enterprise Entry SATA 2.5″ SSD for NeXtScale| N| N| N| N| N| Y| N| Y
4XB7A08497| Intel S4500 1.92TB Enterprise Entry SATA 2.5″ SSD for NeXtScale| N| N| N| N| N| Y| N| Y
4XB7A08498| Intel S4500 3.84TB Enterprise Entry SATA 2.5″ SSD for NeXtScale| N| N| N| N| N| Y| N| Y

Support for System x and dense servers with Intel Xeon v3 processors
Support for servers with Intel Xeon v3 processors

Part number| Description| x3100 M5 (5457)| x3250 M5 (5458)| x3500 M5 (5464)| x3550 M5 (5463)| x3650 M5 (5462)| x3850 X6/x3950 X6 (6241, E7 v3)| nx360 M5 (5465)
---|---|---|---|---|---|---|---|---
2.5-inch drives with G3HS hot-swap tray
7SD7A05732| Intel S4500 240GB Enterprise Entry SATA G3HS 2.5″ SSD| N| N| N| N| N| Y| Y
7SD7A05731| Intel S4500 480GB Enterprise Entry SATA G3HS 2.5″ SSD| N| N| N| N| N| Y| Y
7SD7A05730| Intel S4500 960GB Enterprise Entry SATA G3HS 2.5″ SSD| N| N| N| N| N| Y| Y
4XB7A08493| Intel S4500 1.92TB Enterprise Entry SATA G3HS 2.5″ SSD| N| N| N| N| N| Y| Y
4XB7A08494| Intel S4500 3.84TB Enterprise Entry SATA G3HS 2.5″ SSD| N| N| N| N| N| Y| Y
3.5-inch drives with hot-swap tray
7SD7A05729| Intel S4500 240GB Enterprise Entry SATA HS 3.5″ SSD| N| N| N| N| N| N| N
7SD7A05728| Intel S4500 480GB Enterprise Entry SATA HS 3.5″ SSD| N| N| N| N| N| N| N
7SD7A05727| Intel S4500 960GB Enterprise Entry SATA HS 3.5″ SSD| N| N| N| N| N| N| N
4XB7A08495| Intel S4500 1.92TB Enterprise Entry SATA HS 3.5″ SSD| N| N| N| N| N| N| N
4XB7A08496| Intel S4500 3.84TB Enterprise Entry SATA HS 3.5″ SSD| N| N| N| N| N| N| N
2.5-inch drives for NeXtScale
7SD7A05726| Intel S4500 240GB Enterprise Entry SATA 2.5″ SSD for NeXtScale| N| N| N| N| N| N| Y
7SD7A05725| Intel S4500 480GB Enterprise Entry SATA 2.5″ SSD for NeXtScale| N| N| N| N| N| N| Y
7SD7A05724| Intel S4500 960GB Enterprise Entry SATA 2.5″ SSD for NeXtScale| N| N| N| N| N| N| Y
4XB7A08497| Intel S4500 1.92TB Enterprise Entry SATA 2.5″ SSD for NeXtScale| N| N| N| N| N| N| Y
4XB7A08498| Intel S4500 3.84TB Enterprise Entry SATA 2.5″ SSD for NeXtScale| N| N| N| N| N| N| Y

Server support – Think Server
The following tables list the Think Server systems that are compatible.
Support for Think Server systems with E5 v4 or E3 v6 processors
Support for sd350: The drives supported with the sd350 are listed in System x table.
Support for Think Server Generation 5 servers with E5 v4 or E3 v6 processors

Part number Description E5 v4 E3 v6
TD350 (E5 v4) RD350 (E5 v4) RD450 (E5 v4) **RD550 (E5
v4)** RD650 (E5 v4) TS150 (E3 v6) TS460 (E3 v6)

(E3 v6)
2.5-inch drives with hot-swap tray
4XB0N68504| LTS Gen 5 2.5″ S4500 240GB Entry SATA 6Gbps Hot Swap SSD| N| N| N| Y| Y| N| Y| N
4XB0N68505| LTS Gen 5 2.5″ S4500 480GB Entry SATA 6Gbps Hot Swap SSD| N| N| N| Y| Y| N| Y| N
4XB0N68506| LTS Gen 5 2.5″ S4500 960GB Entry SATA 6Gbps Hot Swap SSD| N| N| N| Y| Y| N| Y| N
4XB0N68510| LTS 2.5″ S4500 240GB Enterprise Entry SATA 6Gbps SSD for RS- Series| N| N| N| N| N| N| N| Y
4XB0N68511| LTS 2.5″ S4500 480GB Enterprise Entry SATA 6Gbps SSD for RS- Series| N| N| N| N| N| N| N| Y
4XB0N68512| LTS 2.5″ S4500 960GB Enterprise Entry SATA 6Gbps SSD for RS- Series| N| N| N| N| N| N| N| Y
3.5-inch drives with hot-swap tray**
4XB0N68507| LTS Gen 5 3.5″ S4500 240GB Entry SATA 6Gbps Hot Swap SSD| N| N| N| Y| Y| N| Y| N
4XB0N68508| LTS Gen 5 3.5″ S4500 480GB Entry SATA 6Gbps Hot Swap SSD| N| N| N| Y| Y| N| Y| N
4XB0N68509| LTS Gen 5 3.5″ S4500 960GB Entry SATA 6Gbps Hot Swap SSD| N| N| N| Y| Y| N| Y| N
4XB0N68513| LTS 3.5″ S4500 240GB Enterprise Entry SATA 6Gbps SSD for RS- Series| N| N| N| N| N| N| N| Y
4XB0N68514| LTS 3.5″ S4500 480GB Enterprise Entry SATA 6Gbps SSD for RS- Series| N| N| N| N| N| N| N| Y
4XB0N68515| LTS 3.5″ S4500 960GB Enterprise Entry SATA 6Gbps SSD for RS- Series| N| N| N| N| N| N| N| Y
4XB0N68516| LTS TS150 2.5″ S4500 240GB Entry SATA 6Gbps SSD with 3.5″ Tray| N| N| N| N| N| Y| N| N
4XB0N68517| LTS TS150 2.5″ S4500 480GB Entry SATA 6Gbps SSD with 3.5″ Tray| N| N| N| N| N| Y| N| N
4XB0N68518| LTS TS150 2.5″ S4500 960GB Entry SATA 6Gbps SSD with 3.5″ Tray| N| N| N| N| N| Y| N| N

Support for Think Server systems with E5 v3 and E3 v5 processors
Support for Think Server systems with E5 v3 and E3 v5 processors

Part number Description E5 v3 E3 v5
TD350 (E5 v3) RD350 (E5 v3) RD450 (E5 v3) **RD550 (E5
v3)** RD650 (E5 v3) RQ750 (E5 v3) TS150 (E3 v5)
(E3 v5)** TS460 (E3 v5) RS160 (E3 v5)

2.5-inch drives with hot-swap tray
4XB0N68504| LTS Gen 5 2.5″ S4500 240GB Entry SATA 6Gbps Hot Swap SSD| N| N| N| N| N| N| N| N| N| N
4XB0N68505| LTS Gen 5 2.5″ S4500 480GB Entry SATA 6Gbps Hot Swap SSD| N| N| N| N| N| N| N| N| N| N
4XB0N68506| LTS Gen 5 2.5″ S4500 960GB Entry SATA 6Gbps Hot Swap SSD| N| N| N| N| N| N| N| N| N| N
4XB0N68510| LTS 2.5″ S4500 240GB Enterprise Entry SATA 6Gbps SSD for RS- Series| N| N| N| N| N| N| N| N| N| N
4XB0N68511| LTS 2.5″ S4500 480GB Enterprise Entry SATA 6Gbps SSD for RS- Series| N| N| N| N| N| N| N| N| N| N
4XB0N68512| LTS 2.5″ S4500 960GB Enterprise Entry SATA 6Gbps SSD for RS- Series| N| N| N| N| N| N| N| N| N| N
3.5-inch drives with hot-swap tray
4XB0N68507| LTS Gen 5 3.5″ S4500 240GB Entry SATA 6Gbps Hot Swap SSD| N| N| N| N| N| N| N| N| N| N
4XB0N68508| LTS Gen 5 3.5″ S4500 480GB Entry SATA 6Gbps Hot Swap SSD| N| N| N| N| N| N| N| N| N| N
4XB0N68509| LTS Gen 5 3.5″ S4500 960GB Entry SATA 6Gbps Hot Swap SSD| N| N| N| N| N| N| N| N| N| N
4XB0N68513| LTS 3.5″ S4500 240GB Enterprise Entry SATA 6Gbps SSD for RS- Series| N| N| N| N| N| N| N| N| N| N
4XB0N68514| LTS 3.5″ S4500 480GB Enterprise Entry SATA 6Gbps SSD for RS- Series| N| N| N| N| N| N| N| N| N| N
4XB0N68515| LTS 3.5″ S4500 960GB Enterprise Entry SATA 6Gbps SSD for RS- Series| N| N| N| N| N| N| N| N| N| N
4XB0N68516| LTS TS150 2.5″ S4500 240GB Entry SATA 6Gbps SSD with 3.5″ Tray| N| N| N| N| N| N| N| N| N| N
4XB0N68517| LTS TS150 2.5″ S4500 480GB Entry SATA 6Gbps SSD with 3.5″ Tray| N| N| N| N| N| N| N| N| N| N
4XB0N68518| LTS TS150 2.5″ S4500 960GB Entry SATA 6Gbps SSD with 3.5″ Tray| N| N| N| N| N| N| N| N| N| N

Server support – Flex System

The following table lists the compatibility information for Flex System servers.
Tip: For the ThinkSystem SN550 and SN850, see the ThinkSystem table.
Support for Flex System servers

Part number| Description| x240 (8737, E5-2600 v2)| x240 (7162)| x240 M5 (9532, E5 v3)| x240 M5 (9532, E5 v4)| x440 (7167)| x880/x480/x280 X6 (7903)| x280/x480/x880 X6 (7196)| Storage Expansion Node
---|---|---|---|---|---|---|---|---|---
7SD7A05732| Intel S4500 240GB Enterprise Entry SATA G3HS 2.5″ SSD| N| N| Y| Y| N| N| N| N
7SD7A05731| Intel S4500 480GB Enterprise Entry SATA G3HS 2.5″ SSD| N| N| Y| Y| N| N| N| N
7SD7A05730| Intel S4500 960GB Enterprise Entry SATA G3HS 2.5″ SSD| N| N| Y| Y| N| N| N| N
4XB7A08493| Intel S4500 1.92TB Enterprise Entry SATA G3HS 2.5″ SSD| N| N| Y| Y| N| N| N| N
4XB7A08494| Intel S4500 3.84TB Enterprise Entry SATA G3HS 2.5″ SSD| N| N| Y| Y| N| N| N| N
7SD7A05729| Intel S4500 240GB Enterprise Entry SATA HS 3.5″ SSD| N| N| N| N| N| N| N| N
7SD7A05728| Intel S4500 480GB Enterprise Entry SATA HS 3.5″ SSD| N| N| N| N| N| N| N| N
7SD7A05727| Intel S4500 960GB Enterprise Entry SATA HS 3.5″ SSD| N| N| N| N| N| N| N| N
4XB7A08495| Intel S4500 1.92TB Enterprise Entry SATA HS 3.5″ SSD| N| N| N| N| N| N| N| N
4XB7A08496| Intel S4500 3.84TB Enterprise Entry SATA HS 3.5″ SSD| N| N| N| N| N| N| N| N
7SD7A05726| Intel S4500 240GB Enterprise Entry SATA 2.5″ SSD for NeXtScale| N| N| N| N| N| N| N| N
7SD7A05725| Intel S4500 480GB Enterprise Entry SATA 2.5″ SSD for NeXtScale| N| N| N| N| N| N| N| N
7SD7A05724| Intel S4500 960GB Enterprise Entry SATA 2.5″ SSD for NeXtScale| N| N| N| N| N| N| N| N
4XB7A08497| Intel S4500 1.92TB Enterprise Entry SATA 2.5″ SSD for NeXtScale| N| N| N| N| N| N| N| N
4XB7A08498| Intel S4500 3.84TB Enterprise Entry SATA 2.5″ SSD for NeXtScale| N| N| N| N| N| N| N| N

Operating system support

SSDs operate transparently to users, storage systems, applications, databases, and operating systems. Operating system support is based on the controller used to connect to the drives. Consult the controller product guide for more information:

Warranty

The Intel S4500 Entry SATA SSDs carry a one-year, customer-replaceable unit (CRU) limited warranty. When the SSDs are installed in a supported server, these drives assume the servers’s base warranty and any warranty upgrades. Solid State Memory cells have an intrinsic, finite number of program/erase cycles that each cell can incur. As a result, each solid state device has a maximum amount of program/erase cycles to which it can be subjected. The warranty for Lenovo solid state drives (SSDs) is limited to drives that have not reached the maximum guaranteed number of program/erase cycles, as documented in the Official Published Specifications for the SSD product. A drive that reaches this limit may fail to operate according to its Specifications.

Physical specifications

The drives have the following physical specifications (approximate, without the tray):

  • Height: 7 mm (0.3 in.)
  • Width: 70 mm (2.8 in.)
  • Depth: 100 mm (4.0 in.)
  • Weight: 63 g (2.2 oz lb) (66 g for the 1.92 TB and 3.84 TB drives)

Shipping dimensions and weight – 2.5-inch drives (approximate, including the tray):

  • Height: 63 mm (2.5 in.)
  • Width: 174 mm (6.9 in.)
  • Depth: 133 mm (5.2 in.)
  • Weight: 434 g (1.0 lb)

Shipping dimensions and weight – 3.5-inch drives (approximate, including the tray):

  • Height: 95 mm (3.7 in.)
  • Width: 257 mm (10.1 in.)
  • Depth: 193 mm (7.6 in.)
  • Weight: 484 g (1.1 lb)
Operating environment

The SSDs are supported in the following environment:

  • Temperature: 0 – 70°C (32 – 158°F)
  • Relative humidity: 5 – 95% (noncondensing)
  • Maximum altitude: 3,050 m (10,000 ft)

Agency approvals
The Intel S4500 Entry SATA SSDs conform to the following regulations:

  • FCC Title 47, Part 15B, Class B
  • CA/CSA-CEI/IEC CISPR 22:02
  • EN 55024: 1998
  • EN 55022: 2006
  • EN-60950-1 2nd Edition
  • UL/CSA EN-60950-1 2nd Edition Low Voltage Directive 2006/95/EC C-Tick: AS/NZS3584
  • BSMI: CNS 13438
  • KCC Article 11.1
  • RoHS DIRECTIVE 2011/65/EU
  • WEEE Directive 2002/96/EC

Related publications and links
For more information, see the following documents:

Related product families
Product families related to this document are the following:

  • Drives

Notices
Lenovo may not offer the products, services, or features discussed in this document in all countries. Consult your local Lenovo representative for information on the products and services currently available in your area. Any reference to a Lenovo product, program, or service is not intended to state or imply that only that Lenovo product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any Lenovo intellectual property right may be used instead. However, it is the user’s responsibility to evaluate and verify the operation of any other product, program, or service. Lenovo may have patents or pending patent applications covering subject matter described in this document. The furnishing of this document does not give you any license to these patents. You can send license inquiries, in writing, to:
Lenovo (United States), Inc.
8001 Development Drive
Morrisville, NC 27560
U.S.A.
Attention:
Lenovo Director of Licensing
LENOVO PROVIDES THIS PUBLICATION ”AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some jurisdictions do not allow disclaimer of express or implied warranties in certain transactions, therefore, this statement may not apply to you. This information could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. Lenovo may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice. The products described in this document are not intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. The information contained in this document does not affect or change Lenovo product specifications or warranties. Nothing in this document shall operate as an express or implied license or indemnity under the intellectual property rights of Lenovo or third parties. All information contained in this document was obtained in specific environments and is presented as an illustration. The result obtained in other operating environments may vary. Lenovo may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you. Any references in this publication to non-Lenovo Web sites are provided for convenience only and do not in any manner serve as an endorsement of those Web sites. The materials at those Web sites are not part of the materials for this Lenovo product, and use of those Web sites is at your own risk. Any performance data contained herein was determined in a controlled environment. Therefore, the result obtained in other operating environments may vary significantly. Some measurements may have been made on development-level systems and there is no guarantee that these measurements will be the same on generally available systems. Furthermore, some measurements may have been estimated through extrapolation. Actual results may vary. Users of this document should verify the applicable data for their specific environment.
© Copyright Lenovo 2022. All rights reserved.
This document, LP0755, was created or updated on July 21, 2021.
Send us your comments in one of the following ways:

This document is available online at https://lenovopress.lenovo.com/LP0755.
Trademarks
Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.
The following terms are trademarks of Lenovo in the United States, other countries, or both:
Lenovo®
Flex System
NeXtScale
ServerProven®
System x®
ThinkServer®
ThinkSystem®
The following terms are trademarks of other companies:
Intel® and Xeon® are trademarks of Intel Corporation or its subsidiaries. Other company, product, or service names may be trademarks or service marks of others.