Gina W G-SL-24W Led Flood Lights Outdoor Motion Sensor Lights User Guide
- June 16, 2024
- Gina W
Table of Contents
Gina W G-SL-24W Led Flood Lights Outdoor Motion Sensor Lights
Specification
- Model No. G-SL-24W
- Rated Voltage 120V,60Hz
- Rated Wattage 24 W
- Max Detection Distance Up to 59.06ft
- Max Detection Degree 180°(plane detection degree)
- Rated Luminous Flux 2400 lm
Safety information
- This product must be installed by the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved
- This light fixture requires a 120-volt AC power source.
- Before installing the light fixture, ensure that all parts are present and the same as the part list. If any part is missing or damaged, do not attempt to assemble, install, or operate this light fixture..
- Turn the power off and test that the power is off before installing the light fixture.
- This light fixture is a non-dimmable product, do not connect this light fixture to a dimmer or timer.
- When using the light fixture, do not cover combustible materials to avoid fire.
- Burn hazard. Allow the light fixture to be cool before touching.
- This device complies with the FCC Rules.
- Install the height of the light fixture not lower than 6.56ft(2m), to avoid disturbance from small animals on the ground within detection range.
- Try to install this light fixture in a place without a metal halide lamp, if can’t avoid it, install the light fixture 3m away from the irradiation scope of the metal halide lamp.
- The light fixture should be installed away from air conditioning, refrigerators, stoves and other sensitive to changes in air temperature, as well as windows and other strong hot air flow places, so as not to cause wrong action.
- When the air temperature is close to a person’s body heat, the detection sensitivity will reduce. 2.13 When the luminaire is installed outdoors during the day if the luminaire is susceptible to induction or intermittent lighting, please adjust the sensitivity level down by one level and then adjust it to the appropriate sensitivity level after installation.
Installation
- Mounting location: wall or eave mounted.
- Mounting Height: The light fixture should be mounted approximately 8ft (2.2-2.5 m) above the ground. If the light fixture is mounted higher or lower than recommended, the coverage area, distance or sensitivity of the sensor will be changed accordingly.
Tools needed to install
Part list
Wiring application
Installation steps
Operation
Setting for the light coverage area
- Tilt the light head left or right to adjust the light coverage area, see the arrow indication direction 1 and 2 to adjust the light head.
- Tilt the light head up or down to adjust the light coverage area, see the arrow indication direction 3 and 4 to adjust the light head.
Setting for the lighting time
- Adjust the switch of “Lighting Time” can set the duration of lighting time when the sensor detects an object movement, then it will turn the light on (The duration time when the objects stop movement), it can be set to 15min,5min,1min and 5s(test).
- When set on 5s(test) position, it is used to test for installation, which is not controlled by ambient lux, and the light will stay on for 5 seconds.
Setting for the ambient lux of the sensor
-
Adjust the “Ambient lux” switch can set the ambient brightness of the sensor by positioning the switch to uncontrolled (not affected by ambient brightness) , Mid(the ambient brightness is brighter) or Low (the ambient brightness is darker)position. Typical ambient lux
- Uncontrolled: not affected by ambient brightness
- Mid: 40~60(lx)
- Low: 10~30(lx)
Setting for the motion sensor detection scope
Adjustment for the detection scope
- The sensor can be adjusted clockwise or counterclockwise per requirement, the maximum can reach 45 degrees, to change the detection scope.
Adjustment and setting for the detection distance
-
As shown in picture 1(schematic diagram of the max detection scope). The sensor can be adjusted up 45°or down 130°. When a fixture is installed on the vertical wall, adjusting the sensor to a different degree can change the detection distance. Normally, when installation at a 5° depression angle for the sensor, the detection distance is the largest. The detection distance and sensitivity will be changed if the mounting height is different.
-
Typical plane diagram of the detection area.
-
Setting for the detection distance means the setting of sensitivity. Adjusting the “Sensitivity ” switch can set the sensitivity of the sensor means changing the sensor’s detection distance, it can be positioned to high, mid, low and OFF (PIR detection disabled).
Remark:- When Sensitivity is set to OFF (PIR detection disabled) and Ambient lux is set to Low and Mid, the security light is in photo-sensitive mode, controlling the light on and off according to the ambient illumination.
- When Sensitivity is set to OFF (PIR detection disabled) and Ambient lux is set to Uncontrolled (not controlled by ambient brightness), the security light is always on and can be switched on and off
Instruction about the setting of motion sensor detection scope
- a. To determine the detection scope of the motion sensor need to perform a simulation test: walking in an arc across the front of the motion sensor.
- b. The motion sensor is less sensitive if in a radial movement. As shown below (picture 1).
- c. The motion sensor is more sensitive if in a lateral movement. As shown below (picture 2).
- d. Watch the light, if the light comes on indicate motion has been detected and give out a lighting signal.
- e. Stop walking and wait for the light to turn off and then begin walking again.
Maintenance
Care and Cleaning
- To prolong the original appearance, suggest cleaning the light fixture with clear water and a soft, damp cloth.
- Do not use paints, solvents, or other chemicals on this light fixture. They could cause premature deterioration and damage to the finish. This is not a defect in the finish and will not be covered by the warranty.
- Do not spray the light fixture with a hose or power washer.
Troubleshooting
FAQ
- Q: What is the recommended mounting height for the light fixture?
- A: The light fixture should be mounted approximately 8ft (2.2-2.5 m) above the ground.
- Q: Can this light fixture be installed on a wall or eave?
- A: Yes, this light fixture can be either wall-mounted or eave-mounted.
- Q: What tools are needed to install the light fixture?
- A: The tools needed for installation include a Phillips screwdriver, flathead screwdriver, safety goggles, circuit tester, wire strippers/cutters, insulated gloves, and a ladder.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>