APsystems 4271901072 ECU-R Energy Communication Unit User Manual
- June 5, 2024
- APsystems
Table of Contents
APsystems 4271901072 ECU-R Energy Communication Unit
Introduction
The APsystems Energy Communication Unit (ECU-R) is the information gateway for our microinverters. The ECU-R collects module performance data from each individual microinverter and transfers the information to an Internet database in real time. Through the APsystems Energy Monitoring and Analysis (EMA) software, the ECU-R gives you precise analysis of each microinverter and PV module in your solar installation powered by APsystems. The user-friendly interface gives you access to your solar array performance in seconds from our web based portal or from our APP.
Features
- Collects individual PV module and microinverter statistics
- Communicates in real time
- Requires no additional wiring
The APsystems ECU-R is used in utility-interactive grid-tied applications, typically consisting of five key elements:
- APsystems microinverter(s)
- APsystems Energy Communication Unit (ECU-R)
- EMA Manager APP: for installer to set-up the ECU-R
- EMA APP: to enable end-users to have access to the data and performance of their system anytime, anywhere
- APsystems Energy Monitoring and Analysis (EMA): web-based monitoring and analysis system, for both end-users and installers
Interface Explanation
Interface Layout
The ECU-R interface includes, (figure 2) from left to right
- Reset button
- Wifi antenna connector (WLAN communication between ECU and router)
- power connection port
- RJ45 Signal port (for Australia only)
- RJ45 ethernet network port (LAN communication between ECU and router)
- Zigbee antenna connector (communication between ECU and microinverters)
On the side ECU: from top to bottom are:
- USB port: for reserved.
- AP button: in case there is need to activate the ECU-R hotspot (see later in the document)
Interface Explanation
Reset
Press the Reset button for a minimum of three seconds: the ECU-R will
automatically return to the default settings.
Power Connection Port
The power connection port connects power through the power adapter.
RJ45 Ethernet Network Port
The ECU-R allows the user to communicate with the EMA server via Ethernet
cable.
RJ45 Signal (Only for Australia)
The RJ45 Signal is designed for DRM0, it should be connected by RJ45 connector
in the package otherwise the inverter will not work.
Antenna
The antennas supplied with the ECU-R must be connected to the ECU-R. One
antenna is used for the communication between ECU-R and microinverters (Zigbee
signal), the other antenna is used for the Wi-Fi connection between ECU-R and
router.
AP
The AP button enables to turn on the ECU wifi hotspot. When setting up the
ECU, installer needs to first connect to the ECU hotspot via his smart phone
or tablet. Press the AP button for a few seconds: the ECU hotspot will be live
for one hour. If more time is needed to set-up the ECU, press the AP button to
reactivate the hotspot.
LED1
LED1 will be ON (green light) when the ECU is powered ON
LED2
LED2 will be ON (green light) when the ECU is exchanging data with the EMA
server. When you haven’t entered microinverters UID into the ECU-R, or The ECU
cannot connect to the EMA server, LED2 is OFF.
Hardware Installation
Preparation
Make sure you have the following components ready before beginning the
installation of the ECU-R:
- A standard AC electrical outlet (located as close as possible of the PV array to ensure good communication between ECU and microinverters).
- A broadband Internet connection is available for your use.
- A broadband router with either a CAT5 Ethernet, or a wireless router.
- A smartphone or tablet with EMA Manager APP ready to use (see page 11).
Selecting an Installation Location for the ECU-R
- Choose a location that is as close as possible of the PV array.
- The ECU-R is NOT rated for outdoor use. If installing outdoor, ensure that the ECU-R is put in a waterproof box, and that the antenna (wifi and Zigee) are placed outside of the box to ensure optimum communication. In case you need to use extension antennas to be closer to the PV array, please make sure the extension antennas are Wifi 2.4GHz with SMA connectors male/female. These extension antennas are not supplied by APsystems, but can be purchased at any electrical/PV shop.
Installation
- Using a Wall Mount When mounting the ECU-R to a wall, make sure to select a cool, dry indoor location.\
- Depending on the wall surface you are mounting the ECU-R to, use either two drywall screws or wall anchors, installed 100 mm apart (The drywall screws and wall anchors are not included in the ECU-R kit).
- Align and slide the ECU-R onto the mounting screws.
- if the HECU-R is not mounted on a wall mount, you can put it anywhere on a flat surface or furniture, close to a power outlet.
Cable Connection
- ECU-R outside of a cabinet (wall-mounted or not)
- Connect the adapter to the power connection port at the back of the ECU-R.
- Installation inside a power cabinet
- Install the socket on the guide rail (The socket is not be supplied by APsystems).
- Connect the adapter to the power connection port at the back of the ECU-R.
NOTICE
ECU antennas must be left outside of the cabinet, even if the cabinet is
made of plastic. Please make sure the extension antennas are Wifi 2.4GHz with
SMA connectors male/female. These extension antennas are not supplied by
APsystems, but can be purchased at any electrical/PV shop.
Internet Connection
There are two different approaches to connecting the ECU-R to the Internet:
Option 1: Direct LAN cable connection.
- Make sure the LAN cable is connected to the network port on the back of the ECU-R.
- Connect the LAN cable to a spare port on the broadband router.
See more info later in the document.
Option 2: Wireless Connection. Use ECU-R internal WLAN (see later in the document, page 15 ).
ECU-R User Interface
please scan QR code below to have access to our products and APP catalog, or click this link to download our APPs: http://q-r.to/1OrC.
- EMA Manager APP: for installers
- Professional installers: all features available
- DIY (Do It Yourself) installers: only ECU_APP features are available
- EMA APP: for end-users only
Commissioning the ECU-R
- Make sure you have downloaded the EMA Manager APP on your smartphone or tablet.
- Make sure the ECU-R hotspot is activated (if not, press the AP button for a few second).
- Open Settings > Wi-Fi in your smartphone or tablet.
- Select ECU-R hotspot: name is ECU_R_216xxxx (mimicking ECU-R serial number).
- Connect your smartphone or tablet to the ECU-R hotspot. Default password is “88888888” (8 times 8).
- Once the connection is established with the ECU-R hotspot, open the EMA Manager APP.
- Select “ECU APP” to enter into the commissioning tool (you can access to ECU APP without any login or password).
Enter microinverters UID (serial numbers) into the ECU-R
- Click “Workspace”, select “ID Management”, and input the microinverter UID (serial number: 12 digits starting with a 4, a 5, a 7 or a 8) manually or scan the UID with your smartphone or tablet scanner.
- Once the microinverter UID has been entered, please press “Sync”.
Historical ID
If the ECU accidentally emptied the inverter list, you can use the same mobile
phone to quickly restore the inverter id list.
Delete UID
- In case of a wrong entry or typo, select the microinverter UIDs, click “Delete” then click “Sync”. The selected UID(s) will be removed from the ECU-R.
- Note : when deleting, please press also “Sync”. Otherwise, the microinverter will not be removed from the ECU-R..
Once the microinverter UID has been successfully entered into the ECU-R, you need to select grid profile and define the adequate time zone of your ECU.
Grid Profile
- From the workspace, select “Grid profile”.
- First select the country and then the city.
Time management
- From the workspace, please select the menu “ECU Date Settings” manual set-up, click “Date”, “Time” and “Timezone” to modify.
- Automated set-up: Click “Time quick setting”: the APP will synchronize on the time and time zone as per smartphone or tablet settings.
Modbus Settings
For three-phase Microinverter: Please refer to the document Altenergy_Power_System_Inc._three_phase_microinverter_11-12.xlsx on SunSpec website. https://certifications.sunspec.org/PICS/Altenergy_Power_System_Inc. _three_phase_microinverter_11-12.xlsx For single-phase Microinverter: Please refer to the document Altenergy_Power_System_Inc._single_phase_MicroinverterAPpcs_11-12 on SunSpec website. https://certifications.sunspec.org/PICS/Altenergy_Power_System_Inc. _single_phase_MicroinverterAPpcs_11-12.xlsx
- Click Modbus Settings in the Workspace, and switch on the SunSpec Modbus function. Select the baud rate and configure Inverters ’ address in the Address text box. Finally, click Save to finish the configuration.
- The host’s RS485 port must be configured to the same baud rate, 8 data bits, 1 stop bit, no parity bit.
ECU Network Settings
WLAN
- From the Workspace menu, select “ECU Network settings”.
- Swipe down the screen, the available SSIDs will be displayed.
- Select the network of your choice and enter its password.
- When connecting to the local Wifi, the smartphone or tablet may lose its connection to the ECU hotspot and connect to another wifi network or 4G.
- If more operations are needed to finish up the ECU commissioning, please make sure to reconnect your smartphone or tablet to the ECU hotspot (may have to press the AP button to re-activate the hotspot).
- When your smartphone or tablet is connected to the ECU hotspot again, you can open the ECU APP home page and check the internet connection status.
- The first bullet (with ECU UID) is green when the smartphone/tablet is properly connected to the ECU hotspot.
- The 2nd bullet shall be green if the internet connection to the router has been successfully established.
LAN
- Make sure the LAN cable is connected to the network port on the back of the ECU-R.
- Connect the LAN cable to a spare port on the broadband router.
- ECU’s wired network setting has 2 options:
- automatically obtain an IP address: the router will give an IP address to the ECU-R automatically (preferred method) .
- use a fixed IP address. In that case, you need to enter your IP address, subnet mask, default gateway, Preferred DNS server and Alternate DNS server.
- Once the LAN connection has been established, you can check the internet connection on the home page of the ECU APP:
- The first bullet (with ECU UID) is green when the smartphone/tablet is properly connected to the ECU hotspot.
- The 2nd bullet shall be green if the internet connection to the router has been successfully established.
Checking the commissioning of the ECU-R
- Once the ECU-R has been commissioned, the installer can check the status on the home page of the ECU APP:
- Several info are displayed
- Systems info (ECU UID, serial number)
- a number of microinverters communicating with the ECU / total number of microinverters entered in the ECU (using the ID Management menu).
- Status of connectivity
- The traffic light (on the left) in front of the ECU UID shows the connectivity status between the smartphone or tablet and the ECU hotspot:
- Smartphone or tablet is connected to the ECU hotspot.
- Smartphone or tablet is not connected to the ECU hotspot. Please try again by pressing the AP button.
- The traffic light (on the right) shows the connectivity status between the ECU and the local internet:
- The ECU is connected to the local internet.
- The ECU is not connected to the internet.
Module
- This page displays the microinverters entered in the ECU (via the Menu ID Management) and properly registered by the ECU. A dual microinverter will be shown by default with 2 PV modules, while a quad microinverters will be shown by default with 4 PV modules. if some DC channels are not connected on purpose, the ECU_APP will nonetheless continue to display the maximum number of panels which can be connected to a given microinverter.
- Removing unused channels needs to be done from the EMA installer account when creating end-user account.
- On the module page, the installer can visualize the performance of microinverters registered into the ECU.
- Click “Panel”: the detailed information of the microinverter is displayed, including inverter UID, PV module DC power, grid voltage, frequency and temperature.
Data
- In this Menu, you can view the detailed data at the system level:
- Per day
- Per month
Inverter Connection Progress
This menu shows the connection progress and communication quality between the
microinverter and ECU, 100% means the connection is over.
The microinverters with “OK” are properly connected to the ECU
Automatic System Check
- Once the ECU has been commissioned, the menu “Automatic System Check” can help you to check the proper communication and production of each microinverter.
- This menu also gives some basic troubleshooting tips.
ECU AP Settings
- This menu can be used if you would like to change the default password of the ECU-R hotspot.
- Please connect to the ECU hotspot first, open the menu “ECU APP settings” and change the password at your convenience.
- If doing a reset of the ECU, the password will be reinitialized as 88888888.
Do-It-Yourself(DIY) Registration
- This menu is only for DIY installers: it will allow DIY installer to create their EMA account by themselves. They can later on access to their account via the EMA APP.
- Once the ECU has been properly commissioned, make sure to connect your smartphone or tablet to local internet.
- Enter “Do it Yourself Registration Menu” and follow instructions to create your own EMA account.
Settings
- This basic menu allows you to change the Language: English, French, Spanish, Portuguese, Polish, Simplified Chinese and traditional Chinese. We’re adapting to more languages.
Technical Data
Communication Interface|
---|---
Integrated Wi-Fi| 802.11g/n
Communication| ZigBee 2.4 GHz
Ethernet| 10/100M Auto-sensing, Auto-negotiation
Wireless security| WEP,WPA2-PSK
USB Port| For Reserved
Power Requirements|
AC Adapter| 5V, 2A
Power Consumption| 1.7W
Maximum Communicating Inverter
Qty(*)
|
100
Mechanical Data|
Dimensions (W×H×D)| 122mm×87mm×25mm (4.8”×3.4”×0.98”)
Weight| 150g (0.33lbs)
Ambient Temperature Range| -20°C to +65°C (-4℉ to +149℉)
Cooling| Nature Convection; No Fans
Enclosure Environmental Rating| Indoor – NEMA 1 (IP20)
Features|
Compliance
| IEC 60950-1, EN60950-1, IEC 60529, EN
60529, ANSI/UL 60950-1,
CAN/CSA C22.2 No.60950-1, UL50E, FCC part 15, EN61000-6-1,
EN61000-6-3, ICES-003, AS NZS 60950-1,
GB/T17799
|
Disposal of your old appliance
- When this crossed-out wheeled bin symbol is attached to a product, it means the product is covered by the European Directive 2002/96/EC.
- All electrical and electronic products should be disposed of separately from the municipal waste stream via designated collection facilities appointed by the government or the local authorities.
- The correct disposal of your old appliance will help prevent potential negative consequences for the environment and human health.
- For more detailed information about the disposal of your old appliance, please contact your city office, waste disposal service or the shop where you purchased the product.
CAUTION
The professional person is allowed to replace the battery. Do not ingest
battery, Chemical Burn Hazard. This product contains a coin/button cell
battery. If the coin/button cell battery is swallowed, it can cause severe
internal burns in just 2 hours and can lead to death. Keep new and used
batteries away from children. If you think batteries might have been swallowed
or placed inside any part of the body, seek immediate medical attention.
FCC STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Please note that changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the useris encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Contact Information