atomi WT-K401 Wireless Alarm Clock Instructions
- June 5, 2024
- atomi
Table of Contents
Vina International holdings ltd | Model: WT-K401 |
---|---|
version: V1.0 |
Specification
Customer: Atomi
name:Qi Wireless Alarm Clock
Model: AT1870, WT-K401
Layout: Mr Yang
Auditing:
Date: 2022-02-18
Date:_____
(Modification Records)
Modification Time | Descriptions | Issued Date | Approved By |
---|---|---|---|
1). Product Standard specification
This specification describes the parameters requirements and inspection rules
of the wireless
charging clock produced by our company.
This specification refers to the national GB8898-2011 audio product safety and
GB13837-2012
sound general specification. GB/T 37687-2019 Wireless charging standard.
2). Product Function Overview
Wt-k401 is a universal product that integrates functions of mobile phone and
Apple Watch wireless charging clock alarm bell patting light night light,
which is suitable for various life scenes
- It can be used for wireless charging of 3C products such as mobile phones and tablets/Apple Watch.
- Can be a timed alarm clock, an internal clock can be in a full charge, continuous for up to two years,
- Can be used as an emotional light source, it can light secretly by dimming, three light colors white light warm white warm color switch.
- Common buttons are designed by touch, which is more convenient to use.
3). Wireless Product electrical parameters
No. | Item | feature |
---|---|---|
2.1 | model | WT-K401 |
2.2 | Product name | Qi Wireless Alarm Clock |
2.3 | Connect port | USB to Type-C |
2.4 | Wireless input voltage/currency | DC5V/2A 9V/2A |
2.5 | Wireless power | 5W / 7.5W / 10W |
2.6 | Iwatch input voltage / currecny / ower | 5V / 500mA / 2.5W |
2.7 | emission frequency | 111.0K-205.0KHZ |
2.8 | standby current | <50MA |
2.9 | Wireless distance | 3mm~6mm (max) |
3.0 | Coil type | A11 |
3.1 | Coil size | Disk diameter:50mm coil thicknedd:2mm |
3.2 | Wireless charging with OTP | Wireless charging with OTP |
3.3 | Wireless protection | (OVP)、(UVP)、(FOD) |
3.4 | Wireless charging indicator function | Two lights: green light/blue light, |
indicating whether wired and wireless charging of the night light is charging,
and foreign matter detection (the blue light is long on when charging), full
(the green light is on, and the indicator turns off after the 30S); The blue
light will flash if there is a foreign object or the phone is not properly
charged.
3.5| compatible| Compatible with QI wireless receiver products
3.6| Temperature/humidity range| The product should be kept away from
corrosive substances and fire and heat sources in dry and ventilated rooms.
Operating temperature: 0 ~ 40 ℃ , storage temperature: -30 ~ 60 ℃ .Operating
humidity: 0% ~ 85%; storage humidity: 0% ~ 90%
---|---|---
4). LED Product electrical parameters
working voltage | 4.2V battery |
---|---|
charge current | 400MA |
Battery | Battery specification 18650 Capacity1200mah-1800mah |
Led power | 1.3W MAX |
instructions | Night light: short press the touch area (3 moded) to switch on |
and off the light and the color grade, and long press to adjust the brightness
5). Clock Product electrical parameters
Clock
4keys in total, Setting、Mode、Up、Down(Distinguishing method; Click the Setting
button to enter the Setting Mode with a number beating, click the Mode button
to switch the display content, click the Up button to switch the clock
brightness, click the Down button to beep the clock)
-
Setting
It is used to enter the Setting Mode. After entering the Setting Mode, the combination of the Setting button and a Mode button can be completed:
The setting of year, month/day, hour/minute; Alarm time setting (set of alarm clocks, on/off) Setting key to switch the Setting content, Mode key to switch the Setting details, Up and Down to set the value -
Mode
Under the normal working conditions, the digital tube displays the current hour/minute. Press the Mode button to display the alarm time. When/min; Month/day; Switch between four states in years. After 10 seconds, the display time/minute is automatically restored. -
Up button/Touch button
Under the normal working condition, the digital tube display a brightness adjustment button, a total of related, dark, medium, bright four levels, press this button can cycle to switch brightness. -
Down
Under normal working conditions, press to set the alarm tone and press to turn on/off the alarm.
The alarm icon will be displayed on the nixie tube after the alarm is turned on -
Clock
The alarm function takes effect only when the alarm time is set to on for one set of alarms.
When the alarm clock buzzes, press the Up button during the buzzer to stop the buzzer. If no button is pressed within 30 seconds, the buzzer will be suspended and the alarm will start again 10 minutes later. Repeat this process a maximum of three times.
The Up button is a snooze button. When the alarm starts, press the Up button to stop the buzzer.
However, the buzzer will continue to ring 5 minutes later. The snooze function only happens on the first press.
If the Up button is pressed for two seconds, the buzzer will be stopped, and no snooze will occur -
The side touch button
adjusts the brightness of the clock(3 modes) and opens and closes the display when short touch.
6.) Test items and standards
Instruments/Tools: Mobile phone/watch, adjustable power supply, Type-C charging cable, charging test box, 5V2A adapter, temperature gun,
Clock night light test
working voltage | 4.2V battery |
---|---|
charge current | 400MA |
Battery | Battery specification 18650 Capacity1200mah-1800mah |
Led power | 1.3W MAX |
instructions | Night light: short press the touch area (3 moded) to switch on |
and off the light and the color grade, and long press to adjust the brightness
Alarm clock function test
The alarm function takes effect only when the alarm time is set to on for one
set of alarms.
When the alarm clock buzzes, press the Up button during the buzzer to stop the
buzzer. If no button is pressed within 30 seconds, the buzzer will be
suspended and the alarm will start again 10 minutes later. Repeat this process
a maximum of three times.
The Up button is a snooze button. When the alarm starts, press the Up button
to stop the buzzer.
However, the buzzer will continue to ring 5 minutes later. The snooze function
only happens on the first press.
If the Up button is pressed for two seconds, the buzzer will be stopped, and
no snooze will occur
7). Reliability testing
5.1| Freefall| Drop the product freely onto the cement floor from 1m height, 6 sides / 1 time for each side. Check whether each side is cracked and loose in the experiment. Then test the electrical function, buttons, lights, shaking the sound inside the listening machine, and so on.| ****
If no parts or structural parts fall off, it is OK
---|---|---|---
5.2| vibration test| According to the characteristics of our vibration tester,
set the frequency of 100Hz, shake for 10 minutes, and observe whether the
product is cracked and loose after the experiment. Check the electrical
function again. Button.
Indicator light. Sound. And so on whether normal.| If no parts or structural
parts fall off, it is OK
5.3| USB plug test| Use the charging cable, simulate the normal use of plug
and unplug action, plug and unplug 1000 times, plug and unplug speed of 10 ~
20 times/minute, after the test to confirm whether the port can be normal plug
and unplug (after the test socket is allowed to have slight appearance
damage), after the test function test whether there is poor contact.| OK
5.4| high low-temperature recycling| Place the product in a temperature-
controlled box with a temperature of 20 ° C ± 5 ° C as follows A) Place the
sample in an experimental chamber with a temperature of 40 ℃ ± 2 ℃ for 2
hours; B) Lower the temperature of the chamber to -10 ℃ ± 2 ℃ and keep it for
4 hours; C) Temperature conversion time is less than 30 minutes; D) Repeat
steps A) to b) for a total of 5 times; Detection products, appearance and
structure without bad phenomenon, no fire and fracture test electrical
function, buttons, indicators, sound, and other no bad phenomena.| ****
OK
6.1| salt spray test| For hardware, a salt spray test should be carried out
before incoming material is put online. 5% NaCl solution, PH value between 6.5
and 7.3, under 35 ℃ environments by the salt spray machine 1.4 ± 0.2kg/CMS 2
air pressure automatic spray for 12 hours. No corrosion occurs.| OK
---|---|---|---
6.2| Keystroke fatigue test| Simulate the action of pressing the key in normal
use. Press the key repeatedly 3000 times with 250g force on the instrument
platform, and confirm whether the key can be used normally after the test.| OK
6.5| Charge test| Take iPhone, Samsung, HUAWEI, Xiaomi, OPPO, and other mobile
phones as the test reference object, respectively play music while charging
whether it is normal.|
6.6| aging test| Turn the lights to maximum brightness and repeat this cycle 3
times. Charge and put for 12 hours, and then test the electrical function to
see if it is normal。| OK
8).product LED
- Standby: The light is off
- Mobile phone charging: FIG. A 5 White light breathing light
- Foreign body detection: Figure A 5 White light flashing
9.)product info:
- N.W:500g
- size :179155104mm (LWH)
- material: ABS+metal+PP+silicone
FCC Warning
This device complies with part 15 of the FCC rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation. Changes or
modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures: Reorient or relocate
the receiving antenna.
Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>