Original instructions

Manual Symbols 2a

BOSCH GLL 3-80 Cross Line Laser - Fig. 1a

  1. BM 1
    0 601 015 A01

  2. LR 6
    0 601 069 H00

  3. LR 7
    0 601 069 J00

  4. 1 608 M00 05B

  5. BT 150
    0 601 096 B00

  6. BT 350
    0 601 015 B00

  7. 1 608 M00 C1Y

  8. 1 608 M00 C20

  9. GCC 30-4
    1 600 A01 1..

BOSCH GLL 3-80 Cross Line Laser - Fig. 2


Safety Instructions

Manual Symbols 2a All instructions must be read and observed in order for the measuring tool to function safely. The safeguards integrated into the measuring tool may be compromised if the measuring tool is not used in accordance with these instructions. Never make warning signs on the measuring tool unrecognisable. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE AND INCLUDE THEM WITH THE MEASURING TOOL WHEN TRANSFERRING IT TO A THIRD PARTY.

  • Warning! If operating or adjustment devices other than those specified here are used or other procedures are carried out, this can lead to dangerous exposure to radiation.
  • The measuring tool is delivered with a warning label (marked in the illustration of the measuring tool on the graphics page).

BOSCH - Laser Radiation. Do not stare.

  • If the text on the warning label is not in your native language, cover it with the label supplied, which is in your language, before initial commissioning.

Do not direct the laser beam at persons or animals and do not stare into the direct or reflected laser beam yourself. You could blind somebody, cause accidents or damage your eyes.

  • If laser radiation hits your eye, you must close your eyes and immediately turn your head away from the beam.
  • Do not make any modifications to the laser equipment.
  • Do not use the laser goggles as protective goggles. The laser goggles make the laser beam easier to see; they do not protect you against laser radiation.
  • Do not use the laser goggles as sunglasses or while driving. The laser goggles do not provide full UV protection and impair your ability to see colours.
  • Have the measuring tool serviced only by a qualified specialist using only original replacement parts. This will ensure that the safety of the measuring tool is maintained.
  • Do not let children use the laser measuring tool unsupervised. They could accidentally dazzle someone.
  • Do not use the measuring tool in explosive atmospheres which contain flammable liquids, gases or dust. Sparks may be produced inside the measuring tool, which can ignite dust or fumes.
  • When operating the measuring tool, loud signal tones may sound under certain circumstances. For this reason, keep the measuring tool away from your ears and from other persons. The loud sound can damage hearing.

Keep the measuring tool and the magnetic accessories away from implants and other medical devices, e.g. pacemakers or insulin pumps. The magnets inside the measuring tool and accessories generate a field that can impair the function of implants and medical devices.

  • Keep the measuring tool and the magnetic accessories away from magnetic data storage media and magnetically sensitive devices. The effect of the magnets inside the measuring tool and accessories can lead to irreversible data loss.
Product Description and Specifications

Please observe the illustrations at the beginning of this operating manual.

Intended Use

The measuring tool is intended for determining and checking horizontal and vertical lines.
The measuring tool is suitable for indoor and outdoor use.

Product Features

The numbering of the product features shown refers to the illustration of the measuring tool on the graphic page.

(1) Laser beam outlet aperture
(2) Battery indicator
(3) Pendulum lock indicator
(4) Receiver mode button
(5) Receiver mode indicator
(6) Button for laser operating mode
(7) On/off switch
(8) 1/4″ tripod mount
(9) 5/8″ tripod mount
(10) Battery compartment cover locking mechanism
(11) Battery compartment cover
(12 ) Laser warning label
(13) Serial number
(14) Recess for Bluetooth® localisation module
(15) Magneta)
(16) Universal holdera)
(17) Laser target platea)
(18) Laser receivera)
(19) Laser googlesa)
(20) Protective baga)
(21) Tripoda)
(22) Telescopic roda)
(23) Casea)
(24) Inlaya)
(25) Bluetooth® localisation modulea)

a) Accessories shown or described are not included with the product as standard. You can find the complete selection of accessories in our accessories range.

Technical Data

Line laser|

GLL 3‑80

---|---
Article number|

3 601 K63 S..

Working rangeA)|
– Standard|

30 m

– in receiver mode|

25 m

– with laser receiver|

5–120 m

Levelling accuracyB)C)D)|

±0.3 mm/m

Self-levelling range|

±4°

Levelling time|

<4 s

Operating temperature|

−10 °C to +40 °C

Storage temperature|

−20 °C to +70 °C

Max. altitude|

2000 m

Relative air humidity max.|

90 %

Pollution degree according to IEC 61010-1|

2 E)

Laser class|

2

Laser type|

630–650 nm, <10 mW

C6|

10

Divergence|

50 × 10 mrad (full angle)

Shortest pulse duration|

1/10000 s

Compatible laser receivers|

LR 6, LR 7

Tripod mount|

1/4″, 5/8″

Batteries|

4 × 1.5 V LR6 (AA)

Duration of operation with 3 laser planes|

4 h

Weight according to EPTA-Procedure 01:2014|

0.82 kg

Dimensions
(length × width × height)|

149 × 84 × 142 mm

Protection rating|

IP 54 (dust and splash-proof)

A) The working range may be reduced by unfavourable environmental conditions (e.g. direct sunlight).
B) At 20–25 °C
C) Applies to the four horizontal intersection points
D) The values stated presuppose normal to favourable environmental conditions (e.g. no vibration, no fog, no smoke, no direct sunlight). Extreme fluctuations in temperature can cause deviations in accuracy.
E) Only non-conductive deposits occur, whereby occasional temporary conductivity caused by condensation is expected.
The serial number (13) on the type plate is used to clearly identify your measuring tool.

Assembly
Inserting/changing the batteries

It is recommended that you use alkaline manganese batteries to operate the measuring tool.
To open the battery compartment cover (11) , press on the locking mechanism (10) and remove the battery compartment cover. Insert the batteries.
When inserting the batteries, ensure that the polarity is correct according to the illustration on the inside of the battery compartment.
The battery indicator (2) always indicates the current battery status:

LED Capacity
Green continuous light 100−75 %
Yellow continuous light 75−35 %
Red continuous light 35−10 %
No light Batteries drained

If the batteries are running low, the laser lines will gradually become dimmer.
Always replace all the batteries at the same time. Only use batteries from the same manufacturer and which have the same capacity.

  • Take the batteries out of the measuring tool when you are not using it for a prolonged period of time. The batteries can corrode and self-discharge during prolonged storage in the measuring tool.
Operation
Starting Operation
  • Protect the measuring tool from moisture and direct sunlight.

  • Do not expose the measuring tool to any extreme temperatures or fluctuations in temperature. For example, do not leave it in a car for extended periods of time. If it has been subjected to significant fluctuations in temperature, first allow the measuring tool to adjust to the ambient temperature and then always carry out an accuracy check before continuing work (see “Accuracy Check of the Measuring Tool”, page 15).
    The precision of the measuring tool may be compromised if exposed to extreme temperatures or fluctuations in temperature.

  • Avoid substantial knocks to the measuring tool and avoid dropping it. Always carry out an accuracy check before continuing work if the measuring tool has been subjected to severe external influences (see “Accuracy Check of the Measuring Tool”, page 15).

  • Switch the measuring tool off when transporting it. The pendulum unit is locked when the tool is switched off, as it can otherwise be damaged by big movements.

Switching On/Off
To switch on the measuring tool, slide the on/off switch (7) to the On” position (for working with the pendulum lock) or to the On” position (for working with automatic levelling). As soon as it is switched on, the measuring tool emits laser lines from the outlet apertures (1).

  • Do not direct the laser beam at persons or animals and do not stare into the laser beam yourself (even from a distance).

To switch off the measuring tool, slide the on/off switch (7) to the Off position. The pendulum unit is locked when the tool is switched off.

  • Never leave the measuring tool unattended when switched on, and ensure the measuring tool is switched off after use. Others may be blinded by the laser beam.

If the maximum permitted operating temperature of 40 °C is exceeded, the tool shuts down to protect the laser diode. Once it has cooled down, the measuring tool is operational again and can be switched back on.
If the temperature of the measuring tool is approaching the maximum permissible operating temperature, the laser lines will gradually become dimmer.

Deactivating the Automatic Shut-Off Function
If no button on the measuring tool is pressed for approx. 120 min, the measuring tool will automatically switch itself off to preserve battery life.
To switch the measuring tool back on after it has been automatically switched off, you can either slide the on/off switch (7) to the “Off” position first and then switch the measuring tool back on, or press either the laser mode button (6) or the receiver mode button (4) once.
To deactivate the automatic shut-off function, hold down the laser mode button (6) for at least 3 s (with the measuring tool switched on). If the automatic shut-off function is deactivated, the laser beams will flash briefly as confirmation.
To activate the automatic shut-off function, switch the measuring tool off and on again.

Deactivating the Signal Tone Function
The signal tone function is always activated once the measuring tool is switched on.
To deactivate or activate the signal tone function, simultaneously press the laser mode button (6) and the receiver mode button (4) and hold them down for at least 3 s.
Three short signal tones will sound as confirmation both when the signal tone function is activated and deactivated.

Operating Modes

The measuring tool has several operating modes which you can switch between at any time. These are for:
– Generating a horizontal laser plane,
– Generating a vertical laser plane,
– Generating two vertical laser planes,
– Generating a horizontal laser plane and two vertical laser planes.

After you switch it on, the measuring tool generates a horizontal laser plane. To change the operating mode, press the laser mode button (6).
All operating modes can be selected with both automatic levelling or the pendulum lock.

Receiver Mode
Receiver mode must be activated when working with the laser receiver (18) , regardless of which operating mode is selected.
In receiver mode, the laser lines flash at a very high frequency, enabling them to be detected by the laser receiver (18).
To switch on receiver mode, press the receiver mode button (4). The receiver mode indicator (5) will light up green.
When receiver mode is switched on, the laser lines are less visible to the human eye. Therefore, switch receiver mode off by pressing the receiver mode button (4) again to work without a laser receiver. The receiver mode indicator (5) will go out.

Automatic Levelling

Working with Automatic Levelling
Position the measuring tool on a level, firm surface or attach it to the universal holder (16) or the tripod (21).
For work with automatic levelling, slide the on/off switch (7) to the On” position.
The automatic levelling function automatically compensates irregularities within the self-levelling range of ±4 °. The levelling is finished as soon as the laser lines stop moving.
If automatic levelling is not possible, e.g. because the surface on which the measuring tool stands deviates by more than 4° from the horizontal plane, the laser lines will begin to flash quickly. If the signal tone function is activated, rapid signal tones will sound.
Set up the measuring tool in a horizontal position and wait for the self- levelling to take place. As soon as the measuring tool is within the self- levelling range of ±4°, the laser lines will light up continuously and the signal tones will cease.
In case of ground vibrations or position changes during operation, the measuring tool is automatically levelled again. Upon re-levelling, check the position of the horizontal or vertical laser line with regard to the reference points to avoid errors by moving the measuring tool.

Working with the Pendulum Lock
For work with the pendulum lock, slide the on/off switch (7) to the On” position. The pendulum lock indicator (3) lights up red and the laser lines continuously flash slowly.
For work with the pendulum lock, the automatic levelling is switched off. You can hold the measuring tool freely in your hand or place it on a sloping surface. This means that the laser lines are no longer levelled and no longer necessarily run perpendicular to one another.

Accuracy Check of the Measuring Tool

Influences on Accuracy
The largest influence is exerted by the ambient temperature. In particular, temperature differences that occur from the ground upwards can refract the laser beam.
Since the temperature stratification is greatest at ground level, you should always mount the measuring tool on a tripod for measuring distances of 20 m or more. In addition, position the measuring tool in the centre of the work surface, wherever this is possible.
In addition to external influences, device-specific influences (e.g. falls or heavy impacts) can also lead to deviations. For this reason, check the levelling accuracy each time before beginning work.
First check the levelling accuracy of the horizontal laser line, then the levelling accuracy of the vertical laser lines.
Should the measuring tool exceed the maximum deviation during one of the tests, please have it repaired by a Bosch after-sales service.

Checking the Horizontal Levelling Accuracy of the Transverse Axis
For this check, you will need a free measuring distance of 5 m on firm ground between two walls (designated A and B).
– Mount the measuring tool close to wall A on a tripod, or place it on a firm, flat surface. Switch on the measuring tool in the mode with automatic levelling. Select the operating mode for generating a horizontal laser plane and a vertical laser plane directly in front of the measuring tool.

BOSCH GLL 3-80 Cross Line Laser - a1

– Aim the laser at the closer wall A and allow the measuring tool to level in. Mark the middle of the point at which the laser lines cross on the wall (point I).

BOSCH GLL 3-80 Cross Line Laser - a2

– Turn the measuring tool 180°, allow it to level in and mark the point where the laser lines cross on the opposite wall B (point II).
– Position the measuring tool – without rotating it – close to wall B, switch it on and allow it to level in.

BOSCH GLL 3-80 Cross Line Laser - a3

– Align the height of the measuring tool (using the tripod or by placing objects underneath as required) so that the point where the laser lines cross exactly hits the previously marked point II on wall B.

BOSCH GLL 3-80 Cross Line Laser - a4

– Turn the measuring tool 180° without adjusting the height. Aim it at wall A such that the vertical laser line runs through the already marked point I. Allow the measuring tool to level in and mark the point where the laser lines cross on wall A (point III).
– The discrepancy d between the two marked points I and III on wall A reveals the actual height deviation of the measuring tool.

The maximum permitted deviation on the measuring distance of 2 × 5 m = 10 m is as follows:
10 m × ±0.3 mm/m = ±3 mm. The discrepancy d between points Ⅰ and Ⅱ must therefore amount to no more than 3 mm.

Checking the Levelling Accuracy of the Vertical Lines
For this check, you will need a door opening (on solid ground) which has at least 2.5 m of space either side of the door.
– Place the measuring tool 2.5 m away from the door opening on a firm, flat surface (not on a tripod). Switch on the measuring tool in the mode with automatic levelling. Select the operating mode for generating a vertical laser plane directly in front of the measuring tool.

BOSCH GLL 3-80 Cross Line Laser - a5

– Mark the centre of the vertical laser line on the floor of the door opening (point I), 5 m away on the other side of the door opening (point II) and on the upper edge of the door opening (point III).

BOSCH GLL 3-80 Cross Line Laser - a6

– Rotate the measuring tool 180° and position it on the other side of the door opening, directly behind point Ⅱ. Allow the measuring tool to level in and align the vertical laser line in such a way that its centre passes through points Ⅰ and Ⅱ exactly.
– Mark the centre of the laser line on the upper edge of the door opening as point Ⅳ.
– The discrepancy d between the two marked points Ⅲ and Ⅳ reveals the actual vertical deviation of the measuring tool.
– Measure the height of the door opening.

Repeat the measuring process for the two vertical laser planes. To do this, select the operating mode for generating a vertical laser plane to one side of the measuring tool and rotate the measuring tool by 90° before beginning the measuring process.
You can calculate the maximum permitted deviation as follows:
Doubled height of the door opening × 0.3 mm/m
Example: At a door opening height of 2 m, the maximum deviation amounts to 2 × 2 m × ±0.3 mm/m = ±1.2 mm. The points Ⅲ and Ⅳ must therefore be no further than 1.2 mm from each other.

Working Advice
  • Only the centre of the laser line must be used for marking. The width of the laser line changes depending on the distance.

Working with the Laser Target Plate
The laser target plate (17) improves visibility of the laser beam in unfavourable conditions and at greater distances.
The reflective half of the laser target plate (17) improves visibility of the laser line. The transparent half enables the laser line to be seen from behind the laser target plate.

Working with the Tripod (Accessory)
A tripod offers a stable, height-adjustable support surface for measuring. Place the measuring tool with the 1/4″ tripod mount (8) on the thread of the tripod (21) or a conventional camera tripod. Use the 5/8″ tripod mount (9) to secure the measuring tool on a conventional building tripod. Tighten the measuring tool using the locking screw of the tripod.
Roughly align the tripod before switching on the measuring tool.

Securing with the universal holder (accessory)
(see figure B)
Using the universal holder (16) , you can secure the measuring tool on vertical surfaces, pipes or magnetizable materials, for example. The universal holder is also suitable for use as a building tripod and facilitates height adjustment of the measuring tool.
Roughly align the universal holder (16) before switching on the measuring tool.

Working with the laser receiver (accessory)
(see figure B)
Use the laser receiver (18) to improve detection of the laser lines in adverse lighting conditions (bright environment, direct sunlight) and over greater distances. When working with the laser receiver, switch on receiver mode (see “Receiver Mode”, page 14).

Laser Goggles (Accessory)
The laser goggles filter out ambient light. This makes the light of the laser appear brighter to the eye.

  • Do not use the laser goggles as protective goggles. The laser goggles make the laser beam easier to see; they do not protect you against laser radiation.
  • Do not use the laser goggles as sunglasses or while driving. The laser goggles do not provide full UV protection and impair your ability to see colours.

Example applications (see figures A­F)
Examples of possible applications for the measuring tool can be found on the graphics pages.

Maintenance and Service
Maintenance and Cleaning

Keep the measuring tool clean at all times.
Never immerse the measuring tool in water or other liquids.
Wipe off any dirt using a damp, soft cloth. Do not use any detergents or solvents.
The areas around the outlet aperture of the laser in particular should be cleaned on a regular basis. Make sure to check for lint when doing this.
Only store and transport the measuring tool in the protective bag (20) or the case (23).
If the measuring tool needs to be repaired, send it off in the protective bag (20) or the case (23).

After-Sales Service and Application Service

Our after-sales service responds to your questions concerning maintenance and repair of your product as well as spare parts. You can find explosion drawings and information on spare parts at: www.bosch-pt.com
The Bosch product use advice team will be happy to help you with any questions about our products and their accessories.
In all correspondence and spare parts orders, please always include the 10digit article number given on the nameplate of the product.

India
Bosch Service Center
69, Habibullah Road, (Next to PSBB School), T. Nagar
Chennai – 600077
Phone: (044) 64561816
Bosch Service Center
18, Community Center
Phase 1, Mayapuri
New Delhi – 110064
Phone: (011) 43166190
Bosch Service Center
Shop no 7&8, Aspen garden
Walbhat road , Goregaon (E)
Near to Ram Mandir Railway Station
Mumbai – 400063
Mobile: 09819952950

Malaysia
Robert Bosch Sdn. Bhd.(220975-V) PT/SMY
No. 8A, Jalan 13/6
46200 Petaling Jaya
Selangor
Tel.: (03) 79663194
Toll-Free: 1800 880188
Fax: (03) 79583838
E-Mail: [email protected]
www.bosch-pt.com.my

Great Britain
Robert Bosch Ltd. (B.S.C.)
P.O. Box 98
Broadwater Park
North Orbital Road
Denham Uxbridge
UB 9 5HJ
At www.bosch-pt.co.uk you can order spare parts or arrange the collection of a product in need of servicing or repair.
Tel. Service: (0344) 7360109
E-Mail: [email protected]

Israel
Ledico Ltd.
31 Lazrov Street
P.O. Box 6018 Rishon Le Ziyon
[email protected]

Korea
Tel.: 080-955-0909 (Hotline)

You can find further service addresses at:
www.bosch-pt.com/serviceaddresses

Disposal

Measuring tools, accessories and packaging should be recycled in an environmentally friendly manner.

Do not dispose of measuring tools or batteries with household waste.

Only for EU countries:

According to the Directive 2012/19/EU on waste electrical and electronic equipment and its transposition into national law, measuring tools that are no longer usable, and, according to the Directive 2006/66/EC, defective or drained batteries must be collected separately and disposed of in an environmentally correct manner.
If disposed incorrectly, waste electrical and electronic equipment may have harmful effects on the environment and human health, due to the potential presence of hazardous substances.

Only for United Kingdom:

According to Waste Electrical and Electronic Equipment Regulations 2013 (2013/3113) and the Waste Batteries and Accumulators Regulations 2009 (2009/890), measuring tools that are no longer usable must be collected separately and disposed of in an environmentally friendly manner.

Licenses

Copyright © 2016–2019 STMicroelectronics
All rights reserved.
Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met:

– Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer.
– Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution.
– Neither the name of STMicroelectronics nor the names of its contributors may be used to endorse or promote products derived from this software without specific prior written permission.

THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS “AS IS” AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.


Bosch Power Tools                                    1 609 92A 7L8 | (22.04.2022)

Robert Bosch Power Tools GmbH
70538 Stuttgart
GERMANY

www.bosch-pt.com

1 609 92A 7L8 (2022.05) TAG / 227

BOSCH GLL 3-80 Cross Line Laser - Bar Code 1

1 609 92A 7L8

BOSCH - Box

Documents / Resources

| BOSCH GLL 3-80 Cross Line Laser [pdf] Instruction Manual
GLL 3-80 Cross Line Laser, GLL 3-80, Cross Line Laser, Line Laser, Laser
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Bosch User Manuals

Related Manuals