F F GROUP BSPU 800 Jet Booster Pump Unit Instruction Manual

June 5, 2024
F F GROUP

BSPU 800 Jet Booster Pump Unit

BSPU 800 Jet Booster Pump Unit

Instruction Manual

BSPU 800/19; BSPU 900/24; BSPU 1300/24

Pump Unit

Pump Unit

SAFETY MEASURES

Read carefully the operating instruction before assembling and starting. The appliance must not be used by operators who are not thoroughly acquainted with the instructions handbook (operating instructions). Moreover, the appliance must not be used by persons under the age of 16.

  • The user is liable towards third parties in the area where the appliance is in operation.
  • Before starting it is necessary to make sure that there are the necessary electrical protection measures, by means of a test carried out by a specialist.

While the pump is operating persons must not be in the liquid to be pumped.

The pump may be connected only by means of a safety switch for fault currents, with a rated opening current up to 30 mA and a socket with an earth contact installed in compliance with the regulations. Protection: at least 10 Amps.

Operation in swimming pools and garden ponds is not recommended.

CAUTION: Before checking, unplug the pump from the mains!

Replacing the connecting up line requires using special tools and therefore this must carried out by the manufacturer or its service engineers. The pump may only operate with a pipe connecting the appliance (extension) that is no lighter than a rubber hose mod. H07 RNF in compliance with the DIN 57282 or DIN 57245 standard.

  • The noise (continuous equivalent in dbA) of the motor-driven pump is less or equal (≤) to 85dbA.
  • The voltage (230 Volts alternating current) indicated on the pump’ s rating plate must correspond to the available mains voltage.
  • The temperature of the liquid conveyed must not exceed35°C.
  • Make sure that the plugged electrical connections are in an area safe from flooding and are protected from humidity.
  • Before use it is necessary to check that the plug and the mains connection line are not damaged.
  • Unplug from the mains before performing any work on the pump.
  • Avoid directly exposing the pump to the jet of water.
  • The user is responsible for complying with the lo-cal regulations for assembly and safety.
  • The user by taking appropriate measures (e.g. in-stalling an alarm, reserve pump and the like) will have to exclude the possibility of indirect damage caused by flooding premises due to failure of the pump.
  • In the event of the pump failing, repair work may only be carried out by an authorized service. Only genuine spare parts must be used.

TECHNICAL DATA

TECHNICAL DATA

CAUTION: Sector of use
The pressure tanks units are used to supply water to houses, farms and factories when the water may be drawn from a well or from a spring and, in addition, for irrigation in market gardening or agriculture. To raise the pressure of the water mains in accordance with local regulations  (max. pressure on inlet 2 bar).

OPERATING INSTRUCTIONS

It is recommended to use a preliminary filter and exhauster with a suction hose and foot valve (re-flux lock) to avoid long suction times and point- lessly damaging the pump due to stones and solid foreign bodies.

BEFORE STARTING

Before starting for the first time the pump has to be filled through the delivery union with the delivery liquid until it overflows.

SUCTION PIPING

  • Fit the suction pipe for drawing water rising towards the pump. Absolutely avoid fitting the suction pipe higher than the pump (formation of air bubbles in the suction pipe).
  • The suction and delivery piping must be fitted so as not to be able to apply any mechanical pressure on the pump.
  • The suction valve should be situated at least 30 cm. below the bottom water level.
  • Suction pipes that are not airtight suck in air ob-structing suction of the water.

DELIVERY PIPING

During suction, the cut-off parts (sprayers, valves, etc.) situated in the delivery piping has to be fully open so that the air in the suction pipe can be freely expelled.

MAINTENANCE INSTRUCTIONS

The pressure tank unit is entirely maintenance free. If the pump gets blocked it will first have to be rinsed out. Connect the pump after removing delivery pipe to the water pipe and let water flow into the suction pipe. While water is flowing into the pump, engage it several times for about 2 seconds. In this way it is possible to eliminate most blockages.

  • If there is a risk of frost, the pump has to be emptied completely.
  • When the pump is not going to be used for a long time, for instance in the winter period, it is recommended to rinse out the pump thoroughly with water, empty it completely and store it in a dry place.
  • Check whether the pump works freely by briefly connecting and disconnecting it.
  • Then fill the pump again with the de-livery liquid and set it up for use.

ADJUSTING CONNECTION AND CUT-OFF PRESSURE.

The pressure tanks unit are factory set with an operating pressure of 1,5÷3,0 bar (see table of specifications). The connection and cut-off pressure can be adjusted and may be set the desired pressure onto according to your need by means of the switch (see figure).

1 = Connection pressure
2 = Cut-off pressure
Take the protective cover off the pressure switch.
With a screwdriver, turn onto – or + according to need.
Check the pressure with the pressure gauge.

CAUTION! In order to work, the pump must always be filled with the delivery liq-uid until it overflows!

CAUTION! The pump must never run dry. The manufacturer’s warranty is null and void in the event of damage to the pump caused by its running dry. Check that the pump is airtight, piping that is not airtight draws in air preventing the pump from working properly.

ENVIRONMENTAL PROTECTION

Information on the disposal of electric and electronic equipment in compliance with directive 2002/96 CE (RAEE).

Warning: do not use the normal house trash bin to dispose of this product.
Used electric and electronic equipment must be handled separately and in compliance with the regulations relating to the treatment, recovery and recycling of the said products.
In accordance with the regulations applied in the member States, private users resident in the EU can take used electric and electronic equipment free of charge to designated collection centers.

If you experience difficulties in locating an authorized disposal center, consult the dealer from whom you purchased the product.

The national regulations provide sanctions against whoever unlawfully disposes of or abandons waste of electric or electronic equipment.

GUARANTEE

This product is warranted in accordance with the le-gal/country specific regulations, effective from the date of purchase by the first user. Damage attributable to normal wear and tear, overload or improper handling will be excluded from the guarantee. In case of a claim, please send the machine, complete-ly assembled, to your dealer or an authorized center for electric power tools.

TROUBLESHOOTING

TROUBLESHOOTING

FF GROUP TOOL INDUSTRIES
9,5 Km Attiki Odos, Aspropyrgos
19300, Athens, Greece
+30 210 55 98 400
info@ffgroup-toolindustries.com
www.ffgroup-tools.com

Documents / Resources

| F F GROUP BSPU 800 Jet Booster Pump Unit [pdf] Instruction Manual
BSPU 800, BSPU 900, BSPU 1300, BSPU 800 Jet Booster Pump Unit, BSPU 800, Jet Booster Pump Unit
---|---
| F F GROUP BSPU 800 Jet Booster Pump Unit [pdf] Instruction Manual
BSPU 800, BSPU 900, BSPU 1300, Jet Booster Pump Unit

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

F F GROUP User Manuals

Related Manuals