F F GROUP DWSP 1100X Submersible Pump for Clear Water
SAFETY MEASURES
- Read carefully the operating instructions before assembling and starting. The ap-pliance must not be used by persons who are not thoroughly acquainted with the instructions handbook (operating instruc-tions). Children and persons under the age of 16 cannot use the pump and must be kept well away from the appliance when it is connected. The user is liable towards third parties in the area where the appli-ance is in operation.
- While the pump is operating, persons must not be in the liquid to be pumped. The pump may be connected only by means of a safe-ty switch for fault currents, with a rated opening current up to 30 mA and a socket with an earth contact installed in conformi-ty with the regulations.
- Protection: at least 10 Amps.
- Operation in swimming pools and garden ponds is admitted.
- CAUTION: Before checking, connect the pump and the system with no voltage!
Replacing the line connecting up with the mains requires using special tools
and therefore may be done only by the manufacturer or its service en-gineers.
The pump may operate only with a pipe connecting the appliance (extension)
that is no lighter than a rubber hose mod. H07 RNF in con-formity with the
DIN57282 or DIN 57245 standard.
(For your safety)
The voltage (230 Volts alternating current) indi-cated on the pump’s rating
plate must correspond to the available mains voltage. Before starting it is
necessary to make sure by having a check made by qualified personnel that
there are the necessary electrical protection measures.
- Earth connection.
- Earthed neutral.
- The safety switch for fault currents corresponds to the safety regulations of the electricity board and functions perfectly.
- Plug connections must be protected from water.
- If there is a risk of flooding, plug connections must be placed somewhere safe.
- Definitely avoid pumping aggressive liquids and abrasive products. In the event of the pump fail-ing, repair work may only be carried out by the repair workshops of the technical service.
- Only genuine spare parts must be used.
- It is notified that in conformity with the law on product liability we cannot be held responsible for the damage caused by our appliance:
- because of improper repairs not carried out by the personnel of the assistance points autho-rized by us;
- or if GENUINE SPARE PARTS are not used to replace parts;
- or if the indications and provisions given in the instructions handbook are not complied with.
The same provisions hold for the accessories.
RESISTANCE
The maximum temperature of the delivery liquid should never exceed +35°C in
continuous operation. Inflammable, combustible or explosive liquids cannot be
conveyed with this pump!
In particular, do not use engine fuels, detergents, or other chemical
products.
OVERVIEW
USE
CAUTION: Sector of use
- DRAINAGE PUMP: To transfer and empty fresh to slightly polluted water from rainwater barrels and casks.
- VORTEX: To transfer water with solids in sus-pension. Also used as emergency pump, in case of over-flowing with muddy water, thanks to its large suction filter.
- To achieve excellent motor cooling the pump cas-ing is provided with a breather hole that enables water to flow out. The pump must be protected from running dry.
STARTING
First put the pump into water and then connect the plug. The pump is ready for
use.
BEFORE STARTING
Installation of your canned motor pump is:
- fixed with a fixed pipe, or
- fixed with a flexible hose.
TAKE CARE
When installing it is necessary to take care that the pump is always placed in
a raised position with respect to the bottom of the well so that the muddy
bottom is not sucked up with the water. Never handle or hang the pump by
gripping the power supply cable.
In pumps with a floating switch, the latter is adjusted in order to make
immediate starting possible.
NOTE:
The pump well must have minimum dimensions of 40x40x50 cm so that the floating
switch can move freely. It is also possible to use round, prefabricated
concrete wells with an inner diameter of approx. 40cm.
MAINTENANCE INSTRUCTIONS
Your canned motor pump is a quality product, free from maintenance. It has been subjected to rigorous final checks. However, for a long service life and con-tinuous operation, we recommend constant care and regular checks:
- Before every maintenance job, disconnect the plug.
- For transportable use the pump should be washed with clear water after every use.
- For fixed installation it is recommended to check the operation of the floating switch every 3 months.
- Using a jet of water, get rid of the fiber and spin-dly particles that may get deposited in the pump’s casing.
- In the event of excessive deposits in the pump casing, dismantle the inlet filter by unscrewing the star screw. Wash the pump casing and fit the inlet filter back on.
- Every 3 months remove the mud from the bottom and walls of the well.
- Eliminate the deposits from the floating switch, washing it with fresh water.
- Protect the pump from frost.
“DRAINAGE”
Special instructions: It is not suitable for pumping: sewage, sandy water.
The pump must never run dry.
The manufacturer’s warranty is null and void in the event of damage to the
pump caused by it running dry.
“VORTEX”
The pump must never run dry.
The manufacturer’s warranty is null and void in the event of damage to the
pump caused by it running dry.
ENVIRONMENTAL PROTECTION
Information on the disposal of electric and electronic equipment in compliance
with directive 2002/96 CE (RAEE).
Warning: do not use the normal house trash bin to dispose of this product.
Used electric and electronic equipment must be handled separately and in
compli-ance with the regulations relating to the treatment, recovery and
recycling of the said products.
In accordance with the regulations applied in the member States, private users
resi-dent in the EU can take used electric and electronic equipment free of
charge to des-ignated collection centers.
If you experience difficulties in locating an authorized disposal center,
consult the dealer from whom you purchased the prod-uct.
The national regulations provide sanctions against whoever unlawfully disposes
of or abandons waste of electric or electronic equipment.
GUARANTEE
This product is warranted in accordance with the le-gal/country specific regulations, effective from the date of purchase by the first user. Damage attribut-able to normal wear and tear, overload or improper handling will be excluded from the guarantee. In case of a claim, please send the machine, completely assembled, to your dealer or the authorized service center.
TECHNICAL DATA
SUBMERSIBLE PUMP FOR CLEAR WATER
Article Number | 43 474 | 43 475 | 43 479 | 43 482 | |
---|---|---|---|---|---|
Model | CWSP 400 | CWSP 750 | CWSP 750X | CWSP 1000MS |
Voltage/Frequency
| V| 230| 230| 230| 230
Hz| 50| 50| 50| 50
Rated Power| W| 400| 750| 750| 1000
Max.pump height| m| 8| 8,5| 8,5| 40
Max.flow rate| L/h| 7000| 12500| 11000| 6500
Max. submersible depth| m| 7| 7| 7| 7
Diameter of Connecting Pipe| | 1”,1 1/4”,
1 1/2”
| 1”,1 1/4”,
1 1/2”
| 1”,1 1/4”,
1 1/2”
| 1”
Max.grain size| mm| 5| 5| 5| 1
Max.media temperature| oC| 35| 35| 35| 35
Min. water pump start level| mm| 100| 135| 35| 60
Min. sunction level| mm| 5| 5| 11| 50
Cable Length| m| 10| 10| 10| 10
Weight| Kg| 3,5| 5,4| 5,8| 9,5
Protection| | IPX8| IPX8| IPX8| IPX8
Insulation Class| | F| F| F| B
SUBMERSIBLE PUMP FOR DIRTY WATER
Article Number| | 43 476| 43 477| 43 478| 43 480|
43 481
---|---|---|---|---|---|---
Model| | DWSP 550| DWSP 750| DWSP 900| DWSP 750X|
DWSP 1100X
Voltage/Frequency
| V| 230| 230| 230| 230| 230
Hz| 50| 50| 50| 50| 50
Rated Power| W| 550| 750| 900| 750| 1100
Max.pump height| m| 7| 8| 8,5| 8| 10,5
Max.flow rate| L/h| 10000| 13000| 14000| 13000| 16500
Max. submersible depth| m| 7| 7| 7| 7| 7
Diameter of Connecting Pipe| | 1”,1 1/4”,
1 1/2”
| 1”,1 1/4”,
1 1/2”
| 1”,1 1/4”,
1 1/2”
| 1”,1 1/4”,
1 1/2”
| 1”,1 1/4”,
1 1/2”
Max.grain size| mm| 35| 35| 35| 35| 35
Max.media temperature| oC| 35| 35| 35| 35| 35
Min. water pump start level| mm| 145| 145| 155| 135| 135
Min. sunction level| mm| 37| 37| 37| 45| 45
Cable Length| m| 10| 10| 10| 10| 10
Weight| Kg| 5,4| 5,5| 5,6| 5,9| 6,8
Protection| | IPX8| IPX8| IPX8| IPX8| IPX8
Insulation Class| | F| F| F| F| F
TROUBLESHOOTING
ENGLISH
TROUBLESHOOTING
PROBLEM| CAUSES| REMEDIES
Motor will not start
| ****
▪ No mains voltage
▪ Pump impeller jammed
▪ Thermostat detached
| ****
▪ Check voltage
▪ Dismantle the hydraulic section and check whether the impeller rotates freely; reas- semble with care
Pump will not suck
| ▪ Suction valve not in water
▪ Pump chamber with no water
▪ Air in suction pipe
▪ Suction valve not airtight
▪ Suction rose dirty
▪ Max. suction lift exceeded
| ▪ Put the suction valve into water (min. 30cm.)
▪ Pour water into the suction union
▪ Check airtight of the suct. pipe
▪ Clean the suction valve
▪ Clean the suction rose
▪ Check the suction lift
Insufficient rate of flow
| ▪ Suction lift too high
▪ Dirty suction rose
▪ Water level falls quickly
▪ Pump flow rate reduced by foreign bodies
| ****
▪ Check suction lift
▪ Clean the suction rose
▪ Set the suct. valve lower down
▪ Clean the pump and replace the worn parts
Thermal cutout switches off pump
| ****
▪ Motor overload. Excessive friction caused by foreign bodies
| ****
▪ Eliminate the foreign bodies. Wait for the thermal cutout switch to trigger again (approx. 20 mins.).
EU DECLARATION OF CONFORMITY
We declare under our sole responsibility that the stated prod-ucts comply with all applicable provisions of the directives and regulations listed below and are in conformity with the following standards.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>