F F GROUP SPP 1200X Jet Pump Instruction Manual

June 5, 2024
F F GROUP

F F GROUP SPP 1200X Jet Pump

how to set

F F GROUP SPP 1200X Jet Pump-fig -1

introduction

SAFETY MEASURES

Read carefully the operating instructions before assembling and starting. The appli-ance must not be used by operators who are not thoroughly acquainted with the instructions handbook (operating instructions). Moreover, the appliance must not be used by persons under the age of 16.

  • The user is liable towards third parties in the area where the appliance is in operation.
  • Before starting it is necessary to check that the nec-essary electrical protection measures are met, by means of a test carried out by a specialist.

While the pump is operating, no person should be in the liquid. The pump may be connected only by means of a safety switch for fault currents, with an opening rated current up to 30 mA and a socket with an earth contact in compliance with the reg-ulations. Protection: at least 10 Amps. Operation in swimming pools and garden ponds is not recommended.
CAUTION: Before checking, unplug the pump from the mains!
Replacing the power supply cable requires using special tools and therefore you must address to the authorized after-sales service.
The pump may only operate with an extension ob-tained through cable mod. H07 RNF and a thread section of no less than 1 mm in compliance with the DIN 57282 or DIN 57245 standard.

  • The noise (continuous equivalent in dbA) of the mo-tor-driven pumps is less or equal (≤) to 85 dbA.
  • The voltage (230 Volts alternating current) indicated on the pump rating plate must correspond to the available mains voltage.
  • The temperature of the liquid conveyed must not exceed 35οC.
  • Never attempt to lift or move the pump by stretch-ing the power-supply cable whilst it is plugged into the mains.
  • Make sure that the plugged electrical connections are in an area safe from flooding and are protected from humidity.
  • Before use it is necessary to check that the plug and the mains connection line are not damaged. Unplug from the mains before performing any work on the pump.
  • Avoid directly exposing the pump to the jet of water.
  • The user is responsible for complying with the local regulations concerning assembly and safety.
  • The user by taking appropriate measures (e.g. install-ing an alarm, reserve pump and the like) will have to exclude the possibility of indirect damage caused by flooding premises due to failure of the pump.
  • In the event of the pump failing, repair work may only be carried out by the repair workshops of the authorized service. Only genuine spare parts must be used.
  • It is notified that in conformity with the law on prod-uct liability we cannot be held responsible for the damage caused by our appliance:
    1. Because of improper repairs not carried out by the personnel of the assistance points autho-rized by us; or
    2. If GENUINE SPARE PARTS are not used to re-place parts; or
    3. If the indications and provisions given in the instructions handbook are not complied with.The same provisions hold for the accessories.

RESISTANCE

This pump should not be used to convey inflam-mable, combustible or explosive liquids.

TECHNICAL DATA

TECHNICAL DATA

Article Number             43 483| 43 484| 43 485
Model| SPP 800X| SPP 1200X| SPP 800
Voltage / Frequence| V| 230| 230| 230
Hz| 50| 50| 50
Rated Power| W| 800| 1200| 800
Max. height| m| 38| 46| 38
Max. flow rate| L/h| 3200| 3700| 3500
Max.suction height| m| 8| 8| 8
Max. Grain Size| mm| 1| 1| 1
Diameter of Connecting Pipe| |

1”

|

1”

|

1”

Max. Pressure| bar| 3,8| 4,6| 3,8
Max. Noise| dB| 85| 85| 85
Max.media temperature| oC| 35| 35| 35
Cable Lenght| m| 1| 1| 1
Weight| kg| 6,4| 7,7| 6,4
Protection                                      IPX4| IPX4| IPX4
Insulation                                          B

Class

| B| B

USE

CAUTION: Sector of use For irrigation and watering of lawns, gar-dens, vegetable patches, etc. For drawing water from ponds, streams, water butts and wells, subject to fitting of suitable filter.

ACCEPTABLE LIQUIDS

In order to pump clear water (freshwater), rainwater or non-aggressive chemical cleaning solutions. Abrasive liquids or any other type of corrosive liq-uid could damage or destroy the pump.

OPERATING INSTRUCTIONS

It is recommended to use a preliminary filter and exhauster with a suction hose, suitable and foot valve (reflux lock) to avoid long suction times and pointlessly damaging the pump due to stones and solid foreign bodies.

BEFORE STARTING

Before starting for the first time, the pump has to be filled through the delivery union with the delivery liquid until it overflows.

SUCTION PIPING

  • Fit the water suction pipe so that it points up-wards towards the pump. Absolutely avoid fitting the suction pipe higher than the pump (formation of air bubbles in the suction pipe).
  • The suction and delivery piping must be fitted so as not to be able to apply any mechanical pressure on the pump.
  • The suction valve should be situated at least 30 cm below the bottom water level.
  • Suction pipes that are not airtight suck in air ob-structing suction of the water.

DELIVERY PIPING
During suction, the cut-off parts (sprayers, valves, etc.) situated in the delivery piping have to be fully open so that the air in the suction pipe can be free-ly expelled.

MAINTENANCE INSTRUCTIONS

The irrigation pump is entirely maintenance-free. Should the pump become blocked, first try rinsing. Should it turn out that the blockage is due to the inefficiency or complete absence of the filters, dis-mantle the hydraulic section and thoroughly rinse the interior, carefully reassemble and refit the filters correctly before turning back on.

  • If there is a risk of frost, the pump has to be emp-tied completely.
  • When the pump is not going to be used for a long time, for instance in the winter period, it is recom-mended to rinse out the pump thoroughly with water, empty it completely and store it in a dry place.
  • Before restarting, check whether the pump works freely by briefly connecting and disconnecting it.
  • Then fill the pump again with the delivery liquid and set it up for use.

CAUTION! In order to work, the pump must always be filled with the delivery liq-uid until it overflows!
CAUTION! The pump must never run dry. The manufacturer’s warranty is null and void in the event of damage to the pump caused by its running dry. Check that the pump is airtight, in fact not airtight pipes draw in air preventing the pump from work-ing properly.

ENVIRONMENTAL PROTECTION

Information on the disposal of electric and electronic equipment in compliance with directive 2002/96 CE (RAEE).
Warning: do not use the normal house trash bin to dispose of this product. Used electric and electronic equipment must be handled separately and in compli-ance with the regulations relating to the treatment, recovery and recycling of the said products.In accordance with the regulations applied in the member States, private users resi-dent in the EU can take used electric and electronic equipment free of charge to des-ignated collection centers. If you experience difficulties in locating an authorized disposal center, consult the dealer from whom you purchased the prod-uct. The national regulations provide sanctions against whoever unlawfully disposes of or abandons waste of electric or electronic equipment.

GUARANTEE

This product is warranted in accordance with the le-gal/country specific regulations, effective from the date of purchase by the first user. Damage attribut-able to normal wear and tear, overload or improper handling will be excluded from the guarantee. In case of a claim, please send the machine, complete-ly assembled, to your dealer or the service center for electric power tools.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals