SAFETY AND WARNINGS

WARNING! If the information in this guide is not followed exactly, a fire or explosion may result causing property damage personal injury, or death.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
NEVER use this appliance as a space heater to heat or warm the room. Doing so may result in carbon monoxide poisoning and overheating of the appliance.

WHAT TO DO IF YOU SMELL GAS

  • Do not try to light any appliance.
  • Do not touch any electrical switch.
  • Do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone.
  • Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency, or gas supplier.

WARNING!
Never operate the top surface cooking section of this appliance unattended.

  • Failure to follow this warning statement could result in fire, explosion, or burn hazards that could cause property damage, personal injury, or death.
  • If a fire should occur, keep away from the appliance and immediately call your fire department. Do not attempt to extinguish an oil/grease fire with water

WARNING!

| Electric Shock Hazard
Failure to follow this advice may result in electrical shock or death.
• Before carrying out any work on the electrical section of the appliance, it must be disconnected from the mains electricity supply.
• Connection to a good ground wiring system is absolutely essential and mandatory.
• Alterations to the domestic wiring system must only be made by a qualified electrician.
WARNING!

| Trip Hazard
Failure to follow this advice may result in death or serious burns.
• To reduce the risk of tipping the appliance, the appliance must be secured by a properly installed anti-tip device packed with the appliance.
• A child or adult can tip the range and be killed.
• Install the anti-tip device to the structure by fastening the supplied bracket to the floor and wall following the instructions for installing the anti-tip device.
• Engage the anti-tip device.
• Re-engage the anti-tip device if the range is moved.
WARNING!

| Weight Hazard
Failure to follow this advice may result in damage or personal injury.
• Proper equipment and adequate manpower must be used in moving the range to avoid personal injury or damage to the unit or the floor. The unit is heavy and rests on adjustable steel legs.
• Two persons are required to move the product safely to the installation location. lb kg
30″ product weight: 408lb (185kg)
36″ product weight: 440lb (200kg)
48″ product weight: 604-640lb (274-290kg)
WARNING!

| Cut Hazard
Failure to use caution could result in injury
• Take care: some edges are sharp.

READ AND SAVE THIS GUIDE
WARNING!
To reduce the risk of fire, injury to persons, or damage when using the appliance, follow the important safety instructions listed below. Read all the guidelines before using the appliance.
Servicing

  • Do not repair or replace any part of the appliance unless specifically recommended in the user guide. All other servicing should be undertaken by a Fisher & Paykel trained and supported service technician or qualified person.
  • Technicians must disconnect the power supply before servicing this appliance.
  • Please make this information available to the person installing the appliance.
  • This appliance must be installed and connected to the mains power supply only by a suitably qualified person according to these installation instructions and in compliance with any applicable local building and electricity regulations. Failure to install the appliance correctly could invalidate any warranty or liability claims.

Gas Requirements

  • Be sure that the unit being installed is set up for the kind of gas being used. The gas range is shipped from the factory set and adjusted for Natural Gas or LP (propane), depending on the specific model ordered. Verify that the range is compatible with the gas at the installation site before proceeding further.
  • Return range to the dealer if the unit is not set for site gas supply.

General

  • The appliance must not be installed behind a decorative door in order to avoid overheating.
  • The range must be grounded.
  • Installation must comply with your local building and electricity regulations.
  • Ensure the installer shows the customer where the gas supply shut-off valve is located.
  • A circuit breaker is recommended.
  • If the power supply cable is damaged, it must be replaced by the manufacturer, its service agent, or a similarly qualified person in order to avoid a hazard.
  • Do not use adaptors, reducers, or branching devices to connect the oven to the mains electricity supply, as they can cause overheating and burning.
  • Improper installation, adjustment alteration, service, or maintenance can cause property damage, injury, or death. Read the installation, operating, and maintenance instructions thoroughly before using, installing, or servicing this appliance.
  • A risk of the appliance tipping over exists if the appliance is not installed in accordance with installation instructions.
  • DO NOT obstruct the flow of combustion or ventilation air to the appliance. Be sure a fresh air supply is available.
  • Check local building codes for the proper method of range installation. Local codes vary. Installation, electrical connections, and grounding must comply with all applicable codes. In the absence of local codes, the range should be installed in accordance with the latest edition of National Fuel Gas Code ANSI Z223.1 and National Electrical Code ANSI / NFPA 70.
  • In Canada: Installation must be in accordance with the current CAN/CGA B149.1 & 2 Gas Installation codes and/or local codes. The electrical installation must be in accordance with the current CSA C22.1 Canadian Electrical Codes Part 1 and/or local codes.
  • Do not lift the range by the door handle. Doing so may damage the product.
  • Before use, ensure all doors are correctly installed.
  • Always keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids.

SAVE THESE INSTRUCTIONS
The models shown in this installation guide may not be available in all markets and are subject to change at any time. For current details about model and specification availability in your country, please go to our website www.fisherpaykel.com or contact your local Fisher & Paykel dealer.

COMPONENTS REQUIRED

PARTS
  • Keep all packing materials until the unit has been inspected.
  • Inspect the product to ensure there is no shipping damage. If any damage is detected contact the dealer or retailer you bought the product from to report the damage.
  • Fisher & Paykel is not responsible for shipping damage.

Supplied

FISHER PAYKEL RGV3 488 48 Inch Freestanding Professional Gas Range -
PARTS

TOOLS

Not supplied

FISHER PAYKEL RGV3 488 48 Inch Freestanding Professional Gas Range -
TOOLS

PRODUCT DIMENSIONS — 30″ MODELS

FISHER PAYKEL RGV3 488 48 Inch Freestanding Professional Gas Range -
PLAN| FISHER PAYKEL RGV3 488 48 Inch Freestanding Professional Gas Range -
ISOMETRIC
---|---

PLAN

|

ISOMETRIC

FISHER PAYKEL RGV3 488 48 Inch Freestanding Professional Gas Range - FRONT
1| FISHER
PAYKEL RGV3 488 48 Inch Freestanding Professional Gas Range -
PROFILE

FRONT

|

PROFILE

PRODUCT DIMENSIONS 30″ MODELS
IN MM

A Overall height*
• Min. (legs fully retracted)
• Max. (legs fully extended)| 35 3/4
36 3/4| 908
933
B Overall width| 29 7/8| 759
C Overall depth| 29 1/8| 740
D Depth of chassis| 25 1/8| 638
E Depth from rear to control panel front| 27 11/16| 703
F Height from cook surface to top of burners| 1  9/16| 40
G Height from cook surface to top of the trim
• Vent Trim
• Angled Vent Trim***| 1 3/4
3 1/2| 45
90
H Height from cook surface to chassis base| 35 1/4| 895
I Height of adjustable feet
• Min. (legs fully retracted)
• Max. (legs fully extended)| 1/2
1 1/2| 13
38
J Depth of open door to front control panel| 19 1/8| 486

excluding burners and trim
excluding handle and dials
purchased separately

PRODUCT DIMENSIONS 30″ MODELS
LB KG
Overall weight (excluding packaging) 408

PRODUCT DIMENSIONS — 36″ MODELS

FISHER PAYKEL RGV3 488 48 Inch Freestanding Professional Gas Range - PLAN
1| FISHER PAYKEL
RGV3 488 48 Inch Freestanding Professional Gas Range - ISOMETRIC
1
---|---

PLAN

|

ISOMETRIC

FISHER PAYKEL RGV3 488 48 Inch Freestanding Professional Gas Range - FRONT
1| FISHER
PAYKEL RGV3 488 48 Inch Freestanding Professional Gas Range -
PROFILE

FRONT

|

PROFILE

PRODUCT DIMENSIONS 30″ MODELS
IN MM

A Overall height*
• Min. (legs fully retracted)
• Max. (legs fully extended)| 35 3/4
36 3/4| 908
933
B Overall width| 3 5  7/ 8| 911
C Overall depth| 29 1/8| 740
D Depth of chassis| 25 1/8| 638
E Depth from rear to control panel front| 27 11/16| 703
F Height from cook surface to the top of burners| 1  9/16| 40
G Height from cook surface to top of the trim
• Vent Trim
• Angled Vent Trim***| 1 3/4
3 1/2| 45
90
H Height from cook surface to chassis base| 35 1/4| 895
I Height of adjustable feet
• Min. (legs fully retracted)
• Max. (legs fully extended)| 1/2
1 1/2| 13
38
J Depth of open door to front control panel| 19 1/8| 486

excluding burners and trim
excluding handle and dials
purchased separately

PRODUCT DIMENSIONS 36″ MODELS
LB KG
Overall weight (excluding packaging) 440

PRODUCT DIMENSIONS — 48″ MODELS

FISHER PAYKEL RGV3 488 48 Inch Freestanding Professional Gas Range - PLAN
2|
---|---

PLAN

|

ISOMETRIC

FISHER PAYKEL RGV3 488 48 Inch Freestanding Professional Gas Range - FRONT
2| FISHER
PAYKEL RGV3 488 48 Inch Freestanding Professional Gas Range -
PROFILE

FRONT

|

PROFILE

PRODUCT DIMENSIONS 30″ MODELS
IN MM

A Overall height*
• Min. (legs fully retracted)
• Max. (legs fully extended)| 35 3/4
36 3/4| 908
933
B Overall width| 47  7/ 8| 1216
C Overall depth| 29 1/8| 740
D Depth of chassis| 25 1/8| 638
E Depth from rear to control panel front| 27 11/16| 703
F Height from cook surface to the top of burners| 1 9/16| 40
G Height from cook surface to top of the trim
• Vent Trim
• Angled Vent Trim***| 1 3/4
3 1/2| 45
90
H Height from cook surface to chassis base| 35 1/4| 895
I Height of adjustable feet
• Min. (legs fully retracted)
• Max. (legs fully extended)| 1/2
1 1/2| 13
38
J Depth of open door to front control panel| 19 1/8| 486

excluding burners and trim
excluding handle and dials
purchased separately

PRODUCT DIMENSIONS 36″ MODELS
LB KG
Overall weight (excluding packaging) 604 –640

CABINETRY DIMENSIONS

30″ CABINETRY

FISHER PAYKEL RGV3 488 48 Inch Freestanding Professional Gas Range - 36
CABINETRY

36″ CABINETRY

FISHER PAYKEL RGV3 488 48 Inch Freestanding Professional Gas Range - 36
CABINETRY

CABINETRY DIMENSIONS 30″ MODELS
INCHES MM

A Overall height*
• Min. (legs fully retracted)
• Max. (legs fully extended)| 35 3/4
36 3/4| 908
933
B Depth
• Flush with counter
• Projecting control panel| 27 11/16

25 1/8

| 703
638
C Width| 30| 762
D Max. depth of overhead cabinetry| 13| 330
E Min. width of ventilation hood required| 30| 762
CABINETRY DIMENSIONS| 30″ MODELS
---|---
INCHES| MM
A Overall height*
• Min. (legs fully retracted)
• Max. (legs fully extended)| 35 3/4
36 3/4| 908
933
B Depth
• Flush with counter
• Projecting control panel| 27 11/16
25 1/8| 703
638
C Width| 36| 914
D Max. depth of overhead cabinetry| 13| 330
E Min. width of ventilation hood required| 30| 914

48″ CABINETRY

FISHER PAYKEL RGV3 488 48 Inch Freestanding Professional Gas Range - 48
CABINETRY

CABINETRY DIMENSIONS 48″ MODELS
INCHES MM

A Overall height*
• Min. (legs fully retracted)
• Max. (legs fully extended)| 35 3/4
36 3/4| 908
933
B Depth
• Flush with counter
• Projecting control panel| 27 11/16
25 1/8| 703
638
C Width| 48| 1219
D Max. depth of overhead cabinetry| 13| 330
E Min. width of ventilation hood required| 48| 1219

CLEARANCES

The below clearances apply to both wall and island installations for all models.
Ensure the cooking surface sits flush or above the adjacent countertop and any openings behind or under the range are sealed. The flow of combustion and ventilation air must not be obstructed.

FISHER PAYKEL RGV3 488 48 Inch Freestanding Professional Gas Range -
CLEARANCES

CLEARANCE DIMENSIONS ALL MODELS
INCHES MM

A Min. distance from the side of the range to the nearest:
• vertical combustible surface| |
B Min. distance from cook surface to overhead:
• combustible surface
• combustible covering for ventilation hood
• non-combustible surface
| 54

36

30

| 1372

914

762

C Min. distance between countertop and cabinet| 18| 457

  • Guidance dimension only. Refer to local codes for installation requirements.
    Non-combustible surfaces: as defined in ‘National Fuel Gas Code’ (ANSI Z223.1, Current Edition). Clearances from noncombustible materials are not part of the ANSI Z21.1 scope and are not certified by UL. Clearances of less than 6″ (152mm) must be approved by the local codes and/or by the local authority having jurisdiction.

BACKGUARD CONSIDERATIONS

WALL SURFACE

FISHER PAYKEL RGV3 488 48 Inch Freestanding Professional Gas Range - WALL
SURFACE

BACKGUARD OPTIONS

RANGE| RANGE MOUNT LOW BACKGUARD| WALL MOUNT HIGH BACKGUARD, LOW SHELF| WALL MOUNT HIGH BACKGUARD, HIGH SHELF| BACKGUARD  WIDTH
---|---|---|---|---
INCHES| MM
30″ models| BGRV2-1230| BGRV2-3030| BGRV3-3030H| 29 7/8| 759
36″ models| BGRV2-1236| BGRV2-3036| BGRV3-3036H| 3 5  7/ 8| 911
48″ models| BGRV2-1248| BGRV2-3048| BGRV3-3048H| 47  7/ 8| 1216

  • Installations against non-combustible surfaces: you may install the range without a backguard or choose any of the three blackguards.
  • Installations close to combustible surfaces (above the cooking surface): without a backguard, there must be a min. 6″ (152mm) clearance.
  • Installations immediately against combustible surfaces (above the cooking surface): you must purchase and fit the Wall Mount High Backguard High Shelf and Angled Vent Trim.
  • Non-combustible surfaces: as defined in ‘National Fuel Gas Code’ (ANSI Z223.1, Current Edition). Clearances from non-combustible materials are not part of the ANSI Z21.1 scope and are not certified by UL. Clearances of less than 6″ (152mm) must be approved by the local codes and/or by the local authority having jurisdiction.

Note: Blackguards can be purchased separately. All ranges come fitted with an Integral Vent Trim only.
For more information on Backguard installation, refer to the separate instructions provided with your backguard.
Backguard Installation Instructions can also be downloaded from our website, www.fisherpaykel.com

VENTILATION REQUIREMENTS

  • Ventilation hoods and blowers are designed for use with single wall ducting, however, some local building codes or inspectors may require double-wall ducting and/or a damper. Consult local building codes and/or agencies before installing to ensure local requirements are met.
  • Hood blower speeds should be variable to reduce noise and loss of household air. The maximum speed should only be required when using the grill or SELF CLEAN.
  • Due to a high volume of ventilation air, a source of make-up air (outside replacement air) is recommended. This is particularly important for tightly sealed and insulated homes. A reputable heating and ventilating contractor should be consulted.
WALL INSTALLATION
Non-combustible Combustible

FISHER PAYKEL RGV3 488 48 Inch Freestanding Professional Gas Range - Non
combustible| FISHER PAYKEL RGV3 488 48 Inch Freestanding Professional Gas
Range - Combustible
VENTILATION UNIT| WALL INSTALLATION RECOMMENDATIONS
---|---
Hood| A  min. 30″ (762mm) max. 42 (762mm)
B  min. 36″ (914mm) max. 42 (762mm)
C  min. 19″ (480mm)
Blower| 30″ Range
36″ Range
48″ Range| min. 550 CFM
min. 550 CFM
min. 1100 CFM
Non-combustible| Combustible
---|---
FISHER PAYKEL RGV3 488 48 Inch Freestanding Professional Gas Range -
ISLAND| FISHER PAYKEL RGV3 488 48 Inch Freestanding Professional Gas Range - ISLAND
1
VENTILATION UNIT| WALL INSTALLATION RECOMMENDATIONS
---|---
Hood| A  min. 30″ (762mm) max. 42 (762mm)
B  min. 36″ (914mm) max. 42 (762mm)
C  min. 19″ (480mm)
Blower| 30″ Range
36″ Range
48″ Range| min. 550 CFM
min. 550 CFM
min. 1100 CFM

ELECTRICAL REQUIREMENTS

The electrical supply must be a correctly polarized 120 VAC, 60 Hz, single- phase circuit suitable for the maximum current draw of the model, as detailed in the table below. Verify your model’s current draw by checking the rating label on the back of the range.
This appliance is factory equipped with a power supply cord with a three-prong grounding plug (with polarized parallel blades). It must be plugged into a mating grounding-type receptacle, and connected to a correctly polarized 120 VAC.
If the circuit does not have a grounding-type receptacle, it is the responsibility and obligation of the installer to have the existing receptacle changed to a properly grounded and polarized receptacle in accordance with all applicable local codes and ordinances by a qualified electrician. In the absence of local codes and ordinances, the receptacle replacement shall be in accordance with the National Electrical Code.
The third prong should not, under ANY circumstances, be cut or removed.

MODEL MAX. CURRENT DRAW CIRCUIT FREQUENCY
RGV3-488 9:00 AM 15 A 60 HZ
RGV3-485GD 15 A 15 A 60 HZ
RGV3-486GD 15 A 15 A 60 HZ
RGV3-366 5:00 AM 15 A 60 HZ
RGV3-304 5:00 AM 15 A 60 HZ
RGV3-305 5:00 AM 15 A 60 HZ
  • This range must be connected to the main power supply by a suitably qualified person.
  • This range must be grounded.
  • Always disconnect the electric supply cord from the wall outlet or service disconnect before servicing this appliance.
  • Observe all governing codes and ordinances when grounding, in absence of which, observe National Electrical Code ANSI / NFPA No. 70.

FISHER PAYKEL RGV3 488 48 Inch Freestanding Professional Gas Range -
diagram

GAS REQUIREMENTS

LP Gas
Connection: 1/2″ NPT Minimum 5/8″ dia. flex line. Supply Pressure: 11″ to 14″ W.C. A regulator is required at the LP source to provide a maximum pressure of 14″ W.C. to the range regulator.
Natural Gas
Connection: 1/2″ NPT Minimum 5/8″ dia. flex line. Supply Pressure: 6″ to 9″ W.C.

  • The gas supply line must not protrude beyond the back of the appliance.
  • Ensure the gas supply is turned off at the wall valve before connecting the appliance.
  • Leak-testing of the appliance shall be conducted according to the manufacturer’s instructions. See guidance on ‘Leak testing’.
  • The appliance must be isolated from the building’s gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 PSIG (3.5kPa.). The appliance and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of the system at the test pressures in excess of 1/2 PSIG (3.5kPa.). When checking the manifold gas pressure, the inlet pressure to the regulator should be at least 7.0″ W.C. for natural gas or 12.0″ W.C. for LP.
  • The flex line for the gas supply must be metal and be approved for appliance use by a certifying agency (CSA, CGA, or UL). Never use a hose made of rubber or other synthetic material, as the heat may cause the hose to melt and develop leaks.
  • When hooking up the gas supply from the wall hard pipe to the range hard pipe, the installation length of the flex line between range/wall hard piping must accommodate the range being pulled from the wall for cleaning or servicing purposes. When the range is pulled from the wall, no strain should occur at the range or wall hard pipe connections.

The gas supply connections should be made by a qualified technician in accordance with local codes or ordinances. In the absence of a local code, the installation must conform to the latest edition of National Fuel Gas Code ANSI Z.223.1 (Warning: this appliance must be installed by a licensed plumber or gas fitter when within the Commonwealth of Massachusetts).
A manual shut-off valve (supplied by the installer) must be installed in an accessible location in the gas line external to the appliance for the purpose of turning on or shutting off gas to the appliance. (In Massachusetts such shut-off valves should be approved by the Board of State Examiners of Plumbers & Gas Fitters.) The shut-off valve must be located within 6 feet (1.8 meters) of the appliance it serves.
Fisher & Paykel recommends installing the manual shut-off valve in a location readily accessible by the customer so that gas to the appliance can be shut off in an emergency situation. However, the appliance must not be modified to accommodate such placement.

FISHER PAYKEL RGV3 488 48 Inch Freestanding Professional Gas Range -
GAS

Verify the type of gas supplied to the location. The range is shipped from the factory set up and adjusted for Natural Gas or LP, depending on the specific model ordered.
Verify that the range is compatible with the gas supply at the installation site before proceeding further. Return the range to the dealer if the unit is not set for the gas supplied at the site.

ELECTRICAL AND GAS SUPPLY LOCATION

FISHER PAYKEL RGV3 488 48 Inch Freestanding Professional Gas Range - SUPPLY
LOCATION| FISHER PAYKEL RGV3 488 48 Inch Freestanding Professional Gas
Range - SUPPLY LOCATION 1
---|---
SUPPLY AREA DIMENSIONS| RGV3
---|---
A Distance from the right edge of range to supply area| 1 1/2” (38mm)
B Width of supply areas
– 30” models
– 36” models
– 48” models| 2” (51mm)
5” (127mm)
3” (76mm)
C Depth of supply areas (ie maximum protrusion of gas connection from wall)| 2” (51mm)
D Height of gas supply area (from the floor)| 12” (305mm)
E Height of electrical supply area (from the floor)| 19” (483mm)

UNPACKING THE RANGE

REMOVE TOE KICK

| | Remove both screws to detach the toe kick from the range.
---|---|---

| | Lift toe kicks up and rotates towards you to remove.

REMOVE DOORS

| | Open the door completely and open the hinge locks fully on both sides.
---|---|---

| | Holding the door on both sides, lift the door back up to 45° and carefully pull the door out and away from the hinges.

REMOVE FROM PALLET

| | Remove front bolts
Remove the two shipping bolts made visible by removing the toe kick.
---|---|---

| **Remove lower guard***
Unscrew the lower guard panel from the back of the range to remove it.

| Remove rear bolts or brackets**
Remove the two shipping bolts or brackets.

FISHER PAYKEL RGV3 488 48 Inch Freestanding Professional Gas Range - packing
sheet

IMPORTANT!
Two people are required.

Before restraining the product to the hand truck, place two cardboard packing sheets (shipped with the product) against both side panels as shown.
Tilt the product and insert the hand truck.
DO NOT insert the hand truck into the front of the product.
Restrain the product and packing sheets to the hand truck using straps and tilt onto the hand truck. Set pallet aside and pull product to the installation location.

TOE KICK INSTALLATION

| | Insert both foot covers into the toe kick ensuring the long hem edge is facing the inside of the product.
---|---|---

| | Align the toe kick with side panels of the range.
Clip into place by rotating and pushing the bracket down over the range structure.

| | Check toe kick is flush with the range and secure using 2 screws.

LEVELLING THE RANGE

| | To expose both front feet, slide the interlocking foot covers out of the way.
Turn your feet to adjust the height.
---|---|---

| | Replace both sets of covers, ensuring each set locks together.

PRIOR TO FINAL POSITIONING

  • Ensure the doors and toe kick panel are securely in place if removed previously.
  • Ensure any backguard is fitted prior to final positioning. Refer to ‘Backguard options’ for all backguard options.
  • Ensure all electrical and gas connections have been done as per instructions.
  • Ensure flooring and adjacent cabinetry are also level. To achieve a flush fit of the range to adjoining countertops, it will be necessary to have level cabinets (front to back and left to right across the opening of the range).

COOKTOP BURNERS

FISHER PAYKEL RGV3 488 48 Inch Freestanding Professional Gas Range - COOKTOP
BURNER

  • To check that the ignition system operates correctly, light each burner by itself, then all burners in combination.
  • Check for a well-defined blue flame without any yellow tipping.
  • If any abnormality is evident, check that the burner assembly is located correctly.
  • When installing the burner port ring, align the two locating pins in the bottom side of the port ring with the locating notch and center holes on the top side of the simmer ring, and make sure these are properly engaged.
  • Incorrect installation may produce a dangerous flame and result in poor performance.
  • No air shutter adjustment is possible on the cooktop burners. Proper operation is achieved with factory-installed settings for the correct gas type.
  • If proper operation cannot be obtained, contact Customer Care or your nearest Fisher & Paykel Authorized Service Center.
  • The range must not be used by the customer until proper operation has been achieved.

LEAK TESTING

  • Ensure all oven and burner knobs are set to OFF before connecting the range to the gas supply.
  • After the final gas connection is made, turn the gas supply on and test all connections in the gas supply piping for gas leaks with a soapy water solution.
  • In order to avoid property damage or serious personal injury, never use an It match or an open flame to check for leaks.

If a leak is present: tighten joint or unscrew, apply more joint compound, tighten again and retest connection for the leak.

INFRARED BROIL AND OVEN BAKE BURNERS

FISHER PAYKEL RGV3 488 48 Inch Freestanding Professional Gas Range - Blue
flame

  • The oven infrared broiler burner has no air shutter and is not adjustable.

  • It is necessary to operate the oven broiler for 20-30 minutes to eliminate the harsh odor of the insulation binder. This must be done before using the range for the first time and with proper ventilation.

  • After approximately 5-8 minutes of operation, the burner screen should be glowing red.

  • The oven bake burner has an air shutter and is adjustable.

  • Check for the proper burner flame characteristics and adjust air shutters if necessary.
    Burner flames should be blue and stable with no yellow tips, excessive noise, or lifting of the flame from the burner. If any of these conditions exist, check that the air shutter or burner ports are not blocked.

  • If the condition persists, adjust the air shutter as below:

  • If the flame is too yellow, indicating insufficient air open the shutter to increase the air inlet.

  • If the flame is noisy or tends to lift away from the burner, indicating too much air, close the shutter to reduce the air inlet.

  • For warranty coverage, Fisher & Paykel requires that all burner adjustments be made by a qualified technician at the time of installation. The improper adjustment will void your warranty.

GRILL AND GRIDDLE BURNERS (SOME MODELS ONLY)

  • Each valve and air shutter is individually tested and adjusted prior to shipment. Normally adjustment is not required, however, vibration during transit, gas conversion, or variations in the local gas supply may make minor adjustments necessary.

  • Check for the proper burner flame characteristics and adjust air shutters if necessary.
    Burner flames should be blue and stable with no yellow tips, excessive noise, or lifting of the flame from the burner. If any of these conditions exist, check that the air shutter or burner ports are not blocked.

  • If the condition persists, adjust the air shutter as below:

  • If the flame is too yellow, indicating insufficient air open the shutter to increase the air inlet.

  • If the flame is noisy or tends to lift away from the burner, indicating too much air, close the shutter to reduce the air inlet.

INSTALLING THE ANTI-TIP BRACKET

WARNING!

| To reduce the risk of tipping the appliance, it must be secured by a properly installed anti-tip device packed with the appliance.
• A child or adult can tip the range and be killed.
• Install the anti-tip device to the structure by fastening the supplied bracket to the floor and wall following the instructions for installing the anti-tip device.
• Engage the anti-tip device.
• Re-engage the anti-tip device if the range is moved.

All ranges must have an anti-tip device correctly installed as per the following instructions. If you pull the range out from the wall for any reason, make sure that the device is properly engaged when you push the range back against the wall. If it is not, there is a risk of the range tipping over and causing injury if you or a child stand, sit or lean on an open oven door.
Instructions are provided for wood and concrete floors. Any other type of construction may require special installation techniques as deemed necessary to provide adequate fastening of the anti-tip bracket to the floor and wall. The use of this bracket does not preclude tipping of the range when not properly installed.

Wood substrate

  1. Place the bracket against the back wall, into the right rear corner where the range is to be located. Leave a 1/2″ (13mm) gap between the wall (or side of range) and the bracket, as shown.
  2. Drill 1/8″ diameter pilot holes in the center of the two small holes. A nail or awl may be used if a drill is not available.
  3. Fasten the bracket securely to the floor and wall.

Concrete or cement substrate

  1. Locate the bracket as shown.
  2. Using the bracket as a template, drill (x2) 5/16″ diameter pilot holes in the center of the larger holes to a depth of at least 1 3/4″.
  3. Place the sleeve anchors into the holes and use a hammer to tap them all the way in.
  4. Tighten the nuts on the sleeve anchors to fasten the bracket securely to the floor.

Once installed
Check for proper installation of the range and anti-tip bracket by grasping the back of the range and carefully attempting to tilt it forward.

FISHER PAYKEL RGV3 488 48 Inch Freestanding Professional Gas Range - ANTI
TIP BRACKET

FINAL CHECKLIST

TO BE COMPLETED BY THE INSTALLER
GENERAL
… Specified clearance maintained.
… Backguard installed if clearance to combustibles behind the unit is less than 6″ (152mm).
… The anti-tip bracket is correctly installed.
… Unit is level – front to back and side to side.
… Griddle (if equipped) and burner pan supports are level and do not rock.
… All packaging materials have been removed. Check below grate and inside the oven.
… The oven door hinges seated and the door opens and closes properly.
… Dials turn correctly and freely.
… Burners light satisfactorily, both individually and with other burners operating.
… Flame adjustments are made if required.
… The front toe kick panel is in place and two screws are secure.

GAS
… Site gas supply is compatible with range.
… LP Connection: 1/2″ NPT Minimum 5/8″ dia. flex line. Supply Pressure: 11″ to 14″ W.C.
… NG Connection: 1/2″ NPT Minimum 5/8″ dia. flex line. Supply Pressure: 6″ to 9″ W.C.
… Manual gas shut-off valve installed in an accessible location.
… Unit tested and free of gas leaks.

ELECTRICAL
… A receptacle with correctly rated and over-current protection is provided for service cord connection.
… Adequate ground connection.

Complete and keep for safe reference:
Model —————————————————————————————–
Serial no. ————————————————————————————–
Purchase date ——————————————————————————–
Purchaser ————————————————————————————-
Dealer address ——————————————————————————-
Installer’s name ——————————————————————————
Installer’s signature ————————————————————————–
Installation company ————————————————————————
Installation date ——————————————————————————

FISHERPAYKEL.COM
© Fisher & Paykel Appliances 2021. All rights reserved.
The models shown in this guide may not be available in all markets and are subject to change at any time.
The product specifications in this guide apply to the specific products and models described at the date of issue. Under our policy of continuous product improvement, these specifications may change at any time.
For current details about model and specification availability in your country, please go to our website or contact your local Fisher & Paykel dealer.

592183C 12.21

Documents / Resources

| FISHER PAYKEL RGV3-488 48-Inch Freestanding Professional Gas Range [pdf] Installation Guide
RGV3-488, RGV3-485GD, RGV3-366, RGV3-305, RGV3-304, RGV3-486GD, 48-Inch Freestanding Professional Gas Range
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Fisher & Paykel User Manuals

Related Manuals