TZ-BT06 is a Bluetooth Low Energy temperature&humidity data logger with the latest Bluetooth 5.0 technology. It can collect the temperature&humidity of the surrounding environment. Such data can be recorded as history data. BT06 can store up to 32000 pieces of the temperature&humidity data. when the long- range mode is enabled, the transmission distance is up to 300 meters, and the LCD screen can view the temperature&humidity data in real-time. Mobile phones with Bluetooth 4.0 or above can download and install App. It can store and monitor the temperature&humidity of the environment comprehensively. Its characteristics are small-sized, low-weighted, easily portable, and highly accurate for wide use in cold chain logistics, archives, labs, museums, etc.

Product application

  1. Refrigerated storage and transportation;
  2. Archives;
  3. Experimental (test) rooms;
  4. Workshop;
  5. Museums;
  6. Pharmaceutical environment;
  7. Fresh transport.

Product features

  1. High accuracy and stability;
  2. Bluetooth 5.0;
  3. Long-distance wireless transfer;
  4. Built-in highly sensitive temperature&humidity sensor;
  5. Real-time broadcast temperature&humidity can view the temperature&humidity in real-time on the LCD;
  6. It can store 32000 pieces of temperature&humidity data(when the storage space is full, the first 256 pieces of data will be overwritten);
  7. Enable long-range mode, the transmission distance is up to 300 meters
  8. Can be set the scope of temperature&humidity alarm;
  9. A history report can be sent to a specified email;
  10. By pairing Bluetooth printer to print the data report;
  11. Can by OTA update version.

Product specification

Item Specification
Protocol standard Bluetooth 5.0
Send interval 1S, adjustable
Built-in battery 620mAh /3V(replaceable)
Output power 4dBm, adjustable
Transmission distance 8dbm:(the biggest) 300 meters(long-range mode,only

Bluetooth 5.0 or above is supported) 150 meters(Non-long range mode)
4dbm:(the default)
200 meters(long-range mode, only Bluetooth 5.0 or above is supported)
120 meters(Non-long range mode)
Storage| Can save 32000 temperature&humidity data
---|---
Operating temperature range| -20℃~ +60℃
Temperature detection accuracy| ±0.3℃(-20~40℃),±0.5℃(other)
Temperature resolution| 0.1℃
Operating Humidity range| 0~90%RH
Humidity detection accuracy| ±3%RH(10~90%),±5%(other)
Humidity resolution| 0.1%RH
Record Interval| 10min(10s~180h)
Alarm Range| Temperature alarm: 2℃~8℃, adjustable
Humidity alarm: 40%~60%, adjustable
battery life| 1 year
Protection grade| IP65
Net weight| 40g
Outline size| 86mm48mm12mm

Caution

  1. Being close to a metal object will interfere with the signal, causing the signal to be weakened;
  2. Note the distance between TZ-BT06 and the receiver to guarantee the accuracy of receiving
  3. Keep away from water and corrosive objects.

Switch Instructions

Device status Operation Instructions
Turn on Under the unopened state, long press button for 3 seconds Turn on

the device, start to send the real-time data, then start recording the data. (the recording is enabled by default.
If the recording is disabled through the APP, also needs to be enabled through the APP)
Turn Off| Open state, long press the button for 3 seconds| Turn off the device
Switching broadcast mode| Under unopened state and broadcast in long-range
mode, short press the“Start” button| The broadcast switched from long-range mode to standard mode, support Bluetooth 5.0 or below is to receive broadcast data for 15 seconds, then back to long-range mode again
Turn off| Open state, short press the “Stop” button| The broadcast is switched to a 0.5-second interval
to speed up the connection for 20 seconds, then back to the preset broadcast interval

CD display description

TZONE TZ BT06 Bluetooth Low Energy Temperature &amp Humidity Data Logger -
fig 1

NO. Instructions NO. Instructions
1 √ OK
× Alarm 6 Bluetooth
2 ▶ Start recording
■Stop recording 7 Bluetooth communicating
3 Alarm zones:

↑H1(high temperature &humidity alarm)
↓L1(Low temperature &humidity alarm)| 8| emperature&Humidity
4| Password protected| 9| ℃ Temperature unit
% Humidity unit
5| Remaining battery level| |

Note: every 2 seconds will switch once the screen display, Temperature interface-> <- Humidity interface.

Battery status displays the description

Battery Capacity
Full
Good
Medium
Lower

(Please replace the battery)

APP

‘Temp Logger’ is a free mobile application provided by our company to the users, who can connect the BT06 through the Bluetooth of the mobile devices and do the settings, data transmission, recording, synchronization, and send to email. Apply the Bluetooth BLE way, so you can use the phone for temperature&humidity monitoring. The client can download App by scanning the QR code below:
Android download: Scan the following QR code;

TZONE TZ BT06 Bluetooth Low Energy Temperature &amp Humidity Data Logger -
QR Codehttp://www.tzonedigital.com/app_download/btlogger_en-us.html

9.1 Device Registration
9.1.1 Open the APP, enter the device ID directly to register on the homepage, or scan the QR code to get the device ID, or do not enter any ID and directly click search to find the device.TZONE TZ BT06 Bluetooth Low Energy
Temperature &amp Humidity Data Logger - fig 29.2.2 Enter the device connection page and click Connect. After a successful connection, the device ID will be displayed on the “Devices” page, indicating that the device has been registered successfully.TZONE TZ BT06 Bluetooth Low Energy Temperature &amp
Humidity Data Logger - fig 3 9.2 Device View
Click the icon in the upper left corner of the home screen to expand the main menu. You can select the menu function and click “device” to enter the multidevice interface. The functions of the device interface areas follows:TZONE TZ BT06 Bluetooth Low Energy Temperature &amp Humidity Data
Logger - fig 4 9.2.1 To view device information
The name, ID, MAC, temperature/humidity data, model, and status of all the current devices can be viewed, or you can view the specific device information by ID, name, and MAC.TZONE TZ BT06 Bluetooth Low Energy Temperature &amp
Humidity Data Logger - fig 5 Status description of the device in different symbols:

Temperature icon display| Status| Humidity icon display| Humidity icon display
---|---|---|---
| Temperature normal| | Humidity normal
| Upper-temperature alarm| | Upper humidity alarm
| Lower temperature alarm| | Lower humidity alarm
| Upper and lower temperature alarm| | Upper and lower humidity alarm

9.2.2 Delete the device:
Long press to delete the device:TZONE TZ BT06 Bluetooth Low Energy
Temperature &amp Humidity Data Logger - fig 14

9.2.3 Device alarm:
When the device exceeds the preset upper or lower limit, the alarm information will be displayed, and the alarm bell will ring. Clicking “CLOSE ” to turn off the alarm information and alarm bell.

9.3 Device connection
Click a single device quickly to enter the connection interface. It will display the temperature/humidity, voltage, RSSI, alarm status, and logger status of the device. Click “CONNECT,” and jump to update after the connection is successful, indicating that the device has been successfully connected and read the current data content. After the connection is successful, it will prompt you whether to view the report or the access key, and the flight mode of the device will be displayed. Four buttons will be displayed at the bottom of the interface:TZONE TZ BT06 Bluetooth Low Energy Temperature &amp
Humidity Data Logger - fig 16

Note: The device will not update the data in the connection process. By default, the device will be disconnected after 1 minute and the four buttons at the bottom will become gray and cannot be clicked again.
9.3.1 Device access key
Click “Access Key” to encrypt the device, and set the level-1 and level-2 access keys.
9.3.1 Firmware upgrade
The firmware upgrade function is disabled by default. If this function is enabled in System Settings, click Firmware Upgrade to upgrade the current version to the latest version. If the current version is the latest version, it cannot be upgraded.
Note: Please do not exit the APP interface during the upgrade process, otherwise the device may be damaged.
9.3.2 Detail and email function
Click “Detail” to view all information reports on the device. Click “EXPORT” to generate PDF and CSV reports, and send the reports to the designated mailbox by email,click “Print” to automatically search the name of the Bluetooth printer. Click the name to automatically pair and print the data report.
A: Details summaryTZONE TZ BT06 Bluetooth Low Energy Temperature &amp
Humidity Data Logger - fig 17TZONE TZ BT06 Bluetooth Low Energy Temperature &amp
Humidity Data Logger - fig 18

Note: The smartphone must have a mailbox APP and login account to send an email.
B: Chart:TZONE TZ BT06 Bluetooth Low Energy Temperature &amp Humidity
Data Logger - fig 19
C: List:TZONE TZ BT06 Bluetooth Low Energy Temperature &amp Humidity Data
Logger - fig 20 9.4 Configure device
After connection, when the device does not start recording, you can click “Configure” to set the device.TZONE TZ BT06 Bluetooth Low Energy Temperature
&amp Humidity Data Logger - fig 21 9.4.1 Device name: The device name can be modified (up to 15byte) by users.
9.4.2 Basic settings:
A: Broadcast interval: The device broadcast interval (range: 0.5s ~30 s),
B: Transmission power: The device transmission power(range:-20dbm~8dbm, default:4dbm,-20dbm is the closest distance, 8dbm is the furthest distance).
C: Long-range mode: on/off(Note: if the long-range mode is on, the phone
Bluetooth 5.0 is below unable to receive broadcast data).
D: Logging interval: Record time of the stored data (range:10s~18h, default:10mins).
E: Logging cycle: It changes with the logging interval.
9.4.3 Advanced settings
A: Access key: The password is configurable and disabled by default (Range: 6digits).
9.4.4 Alarms:
Temperature(Range: -20~60 ℃)
H1: High-temperature limit:8℃
L1: Low-temperature limit:2℃
Humidity(Range: 0~100%)
H1: High humidity limit:60%
L1: Low humidity limit:40%
9.4.5 Description: You can set a description for this device (up to 56 characters).
Note: Click save, and historical data will be deleted.
9.5 Start/Stop recording
Can be started and stopped recorded by the start/stop button.
Note: Click save, and historical data will be deleted.
9.6 Data files
Click the “Data Files” menu bar to enter the data files interface. The functions of the device interface are as follows:TZONE TZ BT06 Bluetooth Low
Energy Temperature &amp Humidity Data Logger - fig 22 9.6.1 To View a single data file
The time displayed in this file is the time when the device data is read for the first time. The information will be updated after each reading until the machine stops recording.
9.6.2 Chart report comparison supporting up to 5 files
Check the data file and click “Comparison” to compare the temperature chart reports of different data files.
9.6.3 Delete data file
Check the data file and click “Delete” to delete the data file.
9.7 System setting
Click the “System setting” menu bar to enter the system setting interface. The functions of the system setting interface areas follows:TZONE TZ BT06
Bluetooth Low Energy Temperature &amp Humidity Data Logger - fig
23 9.7.1 Device Management:

  1. Configuration file: You can view the configuration file saved in “Configure”.

  2. Remember the device access key:
    Don’t turn on the switch: enter the access key every time you connect the device
    Turn on the switch: when connecting the device, you only need to input the access key once (default: remember the key)

  3. The firmware update:
    Don’t turn on the switch: Firmware upgrades are not allowed
    Turn on the switch: After connection, there is a firmware upgrade function(default)

9.7.2 Time &Time zone Setting(Only for generating reports through the APP):

  1. System default/Time Zone:
    Don’t turn on the switch: is UTC time zone or another time zone as you choose
    Turn on the switch: is the current time zone of the system (default: system default)

  2. Data Format: MM/DD/YY HH:MM: SS(default) or DD/MM/YY HH:MM: SS

9.7.3 Report settings(Only for generating reports through the APP):

  1. Include Tabular Data in PDF: Select include or exclude (default: include).
  2. Include Tabular Data in CSV: Select include or exclude (default: include).

9.7.4 Scan and connect device Settings:
A. Connection Timeout: If there is no connection within the specified time, it is considered a connection timeout(default: 20 seconds).

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals