TZ-WF501 is a WIFI temperature sensor based on IOT technology . It can be
widely used in refrigerators, catering, warehouse and HACCP system industries
and so on. It can real-time uploading data to cloud via WIFI . Users can
remotely view, monitor, and manage data online via any web browser. At the
same time, the device also with flash memory to storage 20,000 temperature
recordings. And it can generate PDF report via the USB port. With a built-in
rechargeable lithium backup battery that can provide real-time data uploading
and alarm notifications continously even after power supply cut-off.
Product Application
- Freezer, refrigerator;
- Greenhouse ;
- Warehouse;
- Catering, food and HACCP system industries;
- Pharmacys, biochemical laboratory; etc
Product Features
- High sensitively and precision temperature probe;
- Keep running up to 30 hours after power supply cut-off;
- WiFi real-time data uploading
- 20,000 temperature recordings can be stored into device flash memory, and unlimited reccordings storage on cloud based platform
- Configurable alarm thresholds, uploading interval and temperature unit.
- Easily to generate PDF report via USB port.
- Equipped with LCD display screen, easily to check current temperature, alarm status, WIFI status and battery power ;
- Equipped with buzzer to alarm locally when the temperature exceeds the limit;
Product Specification
Project | C II a ra cteristic |
---|---|
Power supply | 5V/1A (DC) |
Battery | Built in 850mAh / 3.7V battery(rechargeable) |
Sensor range | -55°C to +125°C |
Sensor accuracy | ±0.3°C |
Work environment | -30°C to +60°C; 0% RH — 85% RH (non condensation) |
Communication mode | WiFi |
Collection interval | 1 minute to 60 minutes (configurable) 1 minute by default |
WIFI Frequency band | 2. |
WIFI standard | 802. 11b\g\n |
Low voltage alarm | Support, configurable |
Temperature alarm | Support, configurable |
IP protection class | IP54 |
Flash memory capacity | 20,000 temperature recordings |
Outline specification | 106mm57mm33mm |
Working Mode
Working mode | Working condition |
---|---|
Normal mode | The device collects the temperature data at the configured |
acquisition interval and then enables the
| module to send the data.
---|---
Low voltage alarm mode| When the device voltage is lower than 3.55V
(configurable), it will no longer send data, but store the data and send it
after the device returns to normal.
Temperature alarm mode| When the ambient temperature exceeds the range set by
the user, the transmitter will send data according to the set alarm interval
(settable) to facilitate the customer to record the change of ambient
temperature
Note: Priority: Temperature alarm mode > Low voltage alarm mode> Normal mode
LCD Display Description
In shutdown status, the device’s LCD turns off. In startup status, the LCD
turns on and displays WiFi status,temperature alarm icon, operation status,
temperature over limit
icon, , battery level and temperature value.
S.N | Function | Explanation |
---|---|---|
1 | Temperature alarm icon | Normal: √ Alarm: × |
2 | Operation status | ▷ Working status |
3 | Temperature over limit | Upper limit exceeded: ↑ |
icon | Lower limit exceeded: ↓ |
Both upper and lower limits exceeded: ↑↓
---|---|---
4| WiFi signal strength (RSSI value)| Very strong signal
Strong signal
Good signal
General signal
Poor signal
No display: not connected to WiFi
5| Battery level| Full battery
High battery
Medium
Low
6| Temperature value| Unit: Celsius or Fahrenheit optional
Resolution: 0.1,
When the sensor is abnormal, LCD displays
——
Operating Instruction & Indicator status
7.1 On off operation and indicator status
Operation | Operation method | Indicator status | Explana |
---|---|---|---|
Turn-on | Press and hold the button for 3 seconds | It lights green for 5 | |
seconds | Start working | ||
Turn-off | Press and hold the button for 3 seconds | It lights red for 5 | |
seconds | Stop working |
Note: Please ensure that the power button is turned to ON when switching
on and off the machine.
7.2 To judge device current status by indicator
After startup, if you need to know the device current status, you can check
the indicator status as shown in the table below. If the indicator does not
work, it indicates that the device is in shutdown mode. When the device sends
data, the indicator will flash once, green light standing for normal
temperature and red light standing for abnormal temperature.
The device LED will flash quickly when generating the PDF report, after
finished, the LED will li ght in green.The indicator status has priority. The
larger the value is, the higher the priority is. The indicator status is as
follows:
Device indicator (Green + Red)| |
---|---|---
Device status| LED light| Priorita
Network exception| Red light flashes quickly (on for 0.1s and off for 0.1s)| 1
Power supply disconnect| Red light flashes slowly (on for 1 s and off for 1
s)| 2
Temperature alarm| Red light is on always| 3
Normal state| The green light flashes once when sending data| 4
Alarm Mode
The user can use the configuration software to set the temperature range to
enable the temperature alarm function. When the temperature exceeds the limit,
the machine is in the alarm mode. In the alarm mode, the machine will
immediately send an alarm data, and subsequently collect and send data
according to the collection interval and transmission frequency set by the
user. After the temperature returns to normal, the alarm mode will be released
and the previous acquisition interval will be restored.
At the same time, the machine has the local buzzer alarm function in the alarm
mode. If the buzzer function is enabled (it is enabled by default and always
beeps), the machine will beep according to the set buzzer time.
How to close the buzzer:
- The temperature returns to normal;
- Background sends 037 downlink command
- The working time of the buzzer has expired;
- Press the button;
Note: The buzzer will not work again until the temperature is abnormal
again (the temperature returns to normal first and then abnormal)
Platform Data Query
Temperature & humidity monitoring platform:
Query website:http://t.tzonedigital.cn/
After power on, configure wifi and other parameters with configuration
software, and users can query data on the Tzone platform. To access the
platform, you need to register a user first, and then add the IMEI of WF501 in
the “Device Management” of the “Basic Settings”. After adding the IMEI, you
need to wait for a period of time for the user to query the data after the
machine has reported the data.
Note: By default, the machine sends data to the server once every one
minute of collection interval. The customer can also press the button, and the
machine will immediately send data. The steps to query data are as
follows:For more details, please click “help” button in
the upper right corner of the platform![TZONE TZ-WF501 WiFi Temperature Sensor
- fig 4](https://manuals.plus/wp-content/uploads/2022/11/TZONE-TZ-WF501-WiFi- Temperature-Sensor-fig-4.png)
PDF report data query
The machine supports the local PDF report function. The user only needs to
connect the machine to the computer and use the configuration software to read
the machine information, then click “Generate PDF” to generate the PDF report.
The traffic light flashes during the generation process, and the traffic light
is always on after the completion.
The PDF format is as follows:
DATA REPORT
File Information
ID: 323456789123456
File Created Date: 07/26/21 04:17:19
Note: An Trees shown are based on UTC+0:00 and 24-Hour clod( [MM/DD/YY
HH:MM:SS3
Device Information
Device Type: | WF501 | Fimware Version | 1.00 |
---|---|---|---|
ID: | 323456789123456 |
Logging Summary
Fist Point: | 07/26/21 02:49:36 | Max:28.2t |
---|---|---|
Stop Tine: | 07/26/21 04:16:21 | Min: 26.3-C |
Number of Points: 93 | 90 | Average: 26.9t |
Trip Length: | COd 01h 26m 45s | MKT: 26.9t |
Machine function configuration
The machine supports the configuration of relevant functions with our
configuration software. Connect the machine to the computer and configure it
after generating PDF files. For specific methods, please refer to the
configuration tool documentation.
Client server connection
The machine supports docking with the client server. If the customer needs,
please contact our sales personnel to obtain relevant agreements, SDK and
other materials.
References