Product overview
TZ-BT04 is Bluetooth Low Energy temperature and humidity data logger with the latest Bluetooth 4.1 technology and Nordic NRF51822 chip. It can collect the temperature and humidity of the surrounding environment. Such data can be recorded as history data. BT04 can store up to 12000 pieces of the temperature and humidity data. Mobile phones with Bluetooth 4.0 or above can download and install App. It can store and monitor the temperature and humidity of the environment comprehensively. Its characteristics are small-sized, low- weighted, easily portable, and highly accurate for wide use in cold chain logistics, archives, labs, museums, etc.
Product application
- Refrigerated storage and transportation;
- Archives;
- Experimental (test) rooms;
- Workshop;
- Museums;
- Pharmaceutical environment;
- Fresh transport.
Product features
- High accuracy and stability;
- Bluetooth 4.1;
- Long-distance wireless transfer;
- Built-in highly sensitive temperature and humidity sensor;
- Real-time display temperature and humidity;
- It can store 12000 pieces of temperature and humidity data;
- You can set the alarm temperature range;
- Can be set the scope of temperature alarm;
- Can be set normal storage temperature and humidity data interval and alarm storage temperature and humidity data interval;
- Can choose time to query data, the stored data can be saved in history;
- History report can be sent to specified email;
- By pairing Bluetooth printer to print the data report;
- Can by OTA update version.
Product specification
Item | Specification |
---|---|
Signal transmission frequency | 2.400 – 2.4835GHz |
Protocol standard | Bluetooth 4.1 |
Modulation mode | GFSK |
Send interval | 2S, adjustable |
Built-in battery | CR2450,620mAh /3V |
Output power | -4dBm, adjustable |
Communication rate | 1Mbps |
Transmission distance | 55 meters, adjustable |
Storage | Can save 12000 temperature and humidity data |
battery life | 1.5 years(Depends on the mode of operation, can replace battery) |
Net weight | 30g |
Outline size | 50mm50mm16mm |
Operating temperature range | -25℃~ +60℃ |
Operating Humidity range | 0~85%RH |
Temperature detection accuracy | ±0.3℃(0~60℃),±0.3~0.7℃(other) |
Humidity detection accuracy | ±3%RH(20~80%),±4%(other) |
Caution
- Being close to a metal object will interfere with the signal, causing the signal to be weakened.
- Note the distance between TZ-BT04 and the receiver to guarantee the accuracy of receiving.
- Keep away from water and corrosive objects.
APP
‘Temp Logger’ is a free mobile application which is provided by our company to
the users, can connect the BT04 through the Bluetooth of the mobile devices
and do the settings, data transmission, recording, synchronization, send to
email. Apply the Bluetooth BLE way, so you can use an Android phone for
temperature monitoring.
The client can download App by scanning the QR code below(V25 and above
available):
http://www.tzonedigital.com/app_download/btlogger_en-us.html
6.1 Device Registration
6.1.1 Open the APP, enter the device ID directly to register on the homepage,
or scan the QR code to get the device ID, or do not enter any ID and directly
click search to find the device.
6.2.2 Enter the device connection page and click Connect. After a successful connection, the device ID will be displayed on the “Devices” page, indicating that the device has been registered successfully.
6.2 Device View
Click the icon in the upper left corner of the home screen to expand the main
menu.
You can select the menu function and click “device” to enter the multidevice
interface.
The functions of the device interface are as follow:
6.2.1 To view device information
The name, ID, MAC, temperature/humidity data, model, and status of all the
current devices can be viewed, or you can view the specific device information
by ID, name, and MAC.
Status description of the device in different symbols:
: Temperature normal
: Temperature alarm (including both high and low temperatures)
6.2.2 Delete the device:
Long press to delete the device:
6.2.3 Device alarm:
When the device exceeds the preset upper or lower limit, the alarm information
will be displayed, and the alarm bell will ring. Clicking “CLOSE ” to turn off
the alarm information and alarm bell.
6.3 Device connection
Click a single device quickly to enter the connection interface. It will
display the temperature/humidity, voltage, RSSI, alarm status, and logger
status of the device.
Click “CONNECT,” and jump to update after the connection is successful,
indicating that the device has been successfully connected and read the
current data content. After the connection is successful, it will prompt you
whether to view the report, or the access key and flight mode of the device
will be displayed. Four buttons will be displayed at the bottom of the
interface:
Note: The device will not update the data in the connection process. By
default, the device will be disconnected after 1 minute and the four buttons
at the bottom will become gray and cannot be clicked again.
6.3.1 Device access key
Click “Access Key” to encrypt the device, and set the level-1 and level-2
access keys.
6.3.2 Detail and email function
Click “Detail” to view all information reports of the device. Click “EXPORT”
to generate PDF and CSV reports, and send the reports to the designated
mailbox by email.
A: Details summary
Note: The smartphone must have a mailbox APP and login account to send an
email.
B: Chart:
C: List:
6.4 Configure device
After connection, when the device does not start recording, you can click
“Configure” to set the device.
6.4.1 Device name: The device name can be modified (up to 7byte) by
users.
6.4.2 Basic settings:
A: Transmission power: The device transmission power(range:-30dbm~4dbm,
default:-4dbm)
B: Logging interval: Record time of the stored data (range:10s~1h,
default:1mins).
C: Logging cycle: It changes with the logging interval.
6.4.3 Advanced settings
A: Access key: Must be enabled, default: 000000.
6.4.4 Alarms:
A: Low temperature limit:-25℃
B: High temperature limit:100℃
6.4.5 Description: You can set a description for this device (up to 56
characters).
6.4.6 Start or stop
You can set whether the device starts or stops through the APP.
6.5 Data files
Click the “Data Files” menu bar to enter the data files interface. The
functions of the device interface are as follows:
6.5.1 To View a single data file
The time displayed in this file is the time when the device data is read for
the first time. The information will be updated after each reading until the
machine stops recording.
6.5.2 Chart report comparison supporting up to 5 files
Check the data file and click “Comparison” to compare the temperature chart
reports of different data files.
6.5.3 Delete data file
Check the data file and click “Delete” to delete the data file.
6.6 System setting
Click the “System setting” menu bar to enter the system setting interface. The
functions of the system setting interface are as follows:
7.6.1 Device Management:
-
Configuration file: You can view the configuration file saved in “Configure”.
-
Remember the device access key:
Don’t turn on the switch: enter the access key every time you connect the device
Turn on the switch: when connecting the device, you only need to input the access key once (default: remember the key) -
The firmware update:
Don’t turn on the switch: Firmware upgrades are not allowed
Turn on the switch: After connection, there is a firmware upgrade
function(default)
7.6.2 Time &Time zone Setting(Only for generating reports through the
APP):
-
System default/Time Zone:
Don’t turn on the switch: is UTC time zone or another time zone as you choose
Turn on the switch: is the current time zone of the system (default: system default) -
Data Format: MM/DD/YY HH:MM: SS(default) or DD/MM/YY HH:MM: SS
7.6.3 Report settings(Only for generating reports through the APP):
- Include Tabular Data in PDF: Select include or exclude (default: include).
- Include Tabular Data in CSV: Select include or exclude (default: include).
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>