TZONE TZ-BT05 Portable Smart Temperature Data Logger User Manual
- June 6, 2024
- Tzone
Table of Contents
TZ-BT05
— User Manual V1.7
Product Overview
TZ-BT05 is a low power consumption Bluetooth data logger, using the latest Bluetooth 4.1 technology, Nordic NRF51822 chip development, and design, It can collect temperature of the surrounding environment and record and preservative historical data, can store up to 12000 pieces of temperature data, Bluetooth 4.0 can be downloaded over the phone APP, to achieve full stage real-time temperature recording. It has a small size, is lightweight, easy to carry, has high accuracy, and other characteristics, widely used in various other areas of refrigerated storage and transport, archives, experimental (test) rooms, museums, and other temperature testing.
Applications
- Refrigerated storage and transportation;
- Archives;
- Experimental (test) rooms;
- Workshop;
- Museums;
- Pharmaceutical environment;
- Fresh transport.
Product Features
- The high precision and high stability;
- Bluetooth 4.1;
- The long-distance wireless communication;
- Built-in high sensitivity NTC temperature sensor;
- Real-time display temperature;
- Can store 12000 temperature data;
- You can set the alarm temperature range;
- The temperature graph can be automatically generated in the APP;
- Can choose time to query data, the stored data can be saved in history;
- Temperature data can be generated a PDF/CSV report and sent to a specified email;
- By pairing Bluetooth printer to print the data report;
- Can by OTA update version.
Product specification
Item | Specification |
---|---|
Frequency signal transmission | 2.400 – 2.4835GHz |
Protocol | Bluetooth 4.1 |
Modulation | GFSK |
Transmission interval | 10S, adjustable |
Internal battery | CR2450,62OrnAh/3V |
Output power | -4dBm, adjustable |
Maximum transmission distance | 55 meters ( 4dbm ) |
Storage | can store 12000 pieces of data |
Battery life | 3 years (depends on working mode, can replace battery) |
Net weight | 25g |
Dimension | 66mm*48mme10mm |
Temperature operating range | -25°C–+60°C |
Temperature detecting accuracy | ±-0.5t(-20°C–+40°C)41°C(Other temperature ) |
Caution
- Being close to a metal object will interfere with the signal, causing the signal to be weakened;
- Note that the distance between the TZ-BT05 and the receiver to ensure the reception accuracy;
- Away from the water and corrosive materials.
Switch Instructions
Device status| Operation| LED light instruction|
Instructions
---|---|---|---
Turn on| Under the unopened state, long press button for 3 seconds| Flashes
continuous 3s on then flashes once every 10 seconds| Data logger starts, start
the real-time temperature record
Turn off| Open state, long-press the button for 3 seconds| Flashes 5 times,
then off| Close data logger, keep a record of temperature data
Broadcast interval change to 1 second| Short press the button and no more than
3 seconds| NO flashes| Broadcast interval to 1 second and maintain 60 seconds,
and
restore to the configured broadcast interval after successful connection
APP software
‘Temp Logger’ is a free mobile application which is provided by our company to
the users, can connect the BT05 through the Bluetooth of the mobile devices
and do the settings, data transmission, recording, synchronization, send to
email. Apply the Bluetooth BLE way, so you can use an Android phone for
temperature monitoring.
The client can download App by scanning the QR code below(V12 and above
available):
http://www.tzonedigital.com/app_download/btlogger_en-us.html
Device Registration
1.
Open the APP, enter the device ID directly to register on the homepage,
or scan the QR code to get the device ID, or do not enter any ID and directly
click search to find the device.
2.
Enter the device connection page and click Connect. After a successful
connection, the device ID will be displayed on the “Devices” page, indicating
that the device has been registered successfully.
Device View
Click the icon in the upper left corner of the home screen to expand the main
menu. You can select the menu function and click “device” to enter the
multidevice interface.
The functions of the device interface are as follow:
1.
To view device information
The name, ID, MAC, temperature data, model, and status of all the current
devices can be viewed, or you can view the specific device information by ID,
name, and MAC.
Status description of the device in different symbols:
: Temperature normal
: Temperature alarm (including both high and low temperatures)
2.
Delete the device:
Long press to delete the device:
3. Device alarm:
When the device exceeds the preset upper or lower limit, the alarm information
will be displayed, and the alarm bell will ring. Clicking “CLOSE ” to turn off
the alarm information and alarm bell.
Device connection
Click a single device quickly to enter the connection interface. It will display the temperature, voltage, RSSI, alarm status and logger status of the device. Click “CONNECT,” and jump to update after the connection is successful, indicating that the device has been successfully connected and read the current data content. After the connection is successful, it will prompt you whether to view the report, or the access key and flight mode of the device will be displayed. Four buttons will be displayed at the bottom of the interface:
Note: The device will not update the data in the connection process. By
default, the device will be disconnected after 1 minute and the four buttons
at the bottom will become gray and cannot be clicked again.
1. Device access key
Click “Access Key” to encrypt the device, and set the level-1 and level-2
access keys.
2. Detail and email function
Click “Detail” to view all information reports of the device. Click “EXPORT”
to generate PDF and CSV reports, and send the reports to the designated
mailbox by email.
A: Details summary
Note: The smartphone must have a mailbox APP and login account to send an
email.
B: Chart:
C: List:
Configure device
After connection, when the device does not start recording, you can click “Configure” to set the device.
-
Device name: The device name can be modified (up to 7byte) by users.
-
Basic settings:
A: Transmission power: The device transmission power(range:-30dbm~4dbm, default:-4dbm)
B: Logging interval: Record time of the stored data (range:10s~1h, default:1mins).
C: Logging cycle: It changes with the logging interval. -
Advanced settings
A: Access key: Must be enabled, default: 000000. -
Alarms:
A: Low temperature limit:-40℃
B: High temperature limit:80℃ -
Description : You can set a description for this device (up to 56 characters).
-
Start or stop
You can set whether the device starts or stops through the APP.
Data files
Click the “Data Files” menu bar to enter the data files interface. The functions of the device interface are as follows:
-
To View a single data file
The time displayed in this file is the time when the device data is read for the first time. The information will be updated after each reading until the machine stops recording. -
Chart report comparison supporting up to 5 files
Check the data file and click “Comparison” to compare the temperature chart reports of different data files. -
Delete data file
Check the data file and click “Delete” to delete the data file.
System setting
Click the “System setting” menu bar to enter the system setting interface. The functions of the system setting interface are as follows:
-
Device Management:
1. Configuration file: You can view the configuration file saved in “Configure”.
2. Remember the device access key:
Don’t turn on the switch: enter the access key every time you connect the device Turn on the switch: when connecting the device, you only need to input the access key once (default: remember the key)
3. The firmware update:
Don’t turn on the switch: Firmware upgrades are not allowed
Turn on the switch: After connection, there is a firmware upgrade function(default) -
Time &Time zone Setting(Only for generating reports through the APP):
1. System default/Time Zone:
Don’t turn on the switch: is UTC time zone or another time zone as you choose Turn on the switch: is the current time zone of the system (default: system default)
2. Data Format: MM/DD/YY HH:MM: SS(default) or DD/MM/YY HH:MM: SS -
Report settings(Only for generating reports through the APP):
1. Include Tabular Data in PDF: Select include or exclude (default: include).
2. Include Tabular Data in CSV: Select include or exclude (default: include).
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>