Photocell (LUX Only) – Controlled by the Lux level. Photocell with Timer P1 (Timer) – light switches on depending on lux level, the light will be switched off based on the “TIME” setting between 3 mins – 8 hrs (approx.) Photocell with Timer P2 (Timer) – light switches on depending on lux level, the light will be switched off based on the “TIME” setting between 3 mins – 8 hours approx. the light will then switch on approx. 2 hours before dawn. However, on the first cycle the light will not switch on at dawn as product needs to record the first dusk till dawn cycle duration.

**UNDERSTANDING THE CONTROLS

LAP RD0006 -Indoor- and- Outdoor- Black
-Photocell- Sensor -7**

ADJUSTING THE DURATION TIME: The length of time that the light remains switched on after activation can be adjusted from 4±1 minutes to 8±0.5 hours. Rotating the TIME knob from (+) to (-) will reduce the duration time. Note: This knob can only used with Photocell with Timer P1/P2.
ADJUSTING THE LUX CONTROL LEVEL BY KNOB : The LUX control module has a built-in sensing device (photocell) that detects daylight and darkness. The position means that the lights can work at day and night, and the position indicates that the lights can work only at night. You can set to operate the unit at the desired brightness level by adjusting the LUX knob. Wait for the desired brightness level, and then slowly rotate the LUX control knob from to until the light is on.
Note: for best nighttime use please set the lux between 5 and 50 lux, for activation during the day, it is recommended to be above 100 lux.

THE SHIFT BUTTON

  • Press the shift button once (for less than 3 seconds) with a sharp tool to change the the functions from Photocell to Photocell with Timer P1, Photocell with Timer P1 to Photocell with Timer P2 and Photocell with Timer P2 to Photocell. When the power is switched on, the unit is set to Photocell.
  • Users can change the “Fixed LUX” mode to “Adjustable LUX” mode by pressing he shift button once (for more than 3 seconds). The LED will flash 3 times as an indication. User can adjust the LUX to the desired level using the LUX knob in the adjustable settings only.
  • The LUX setting will be set to the current environment LUX level .

USE TIPS

  1. If you need to use the product all night, choose Photocell.
  2. If you only need to use the product for a few hours, choose Photocell with Timer P1, and set a time required.
  3. If you want the light to switch on before dawn, choose Photocell with Timer P2. This function will switch the light on approx. 2 hours before dawn.LAP RD0006 -Indoor- and- Outdoor- Black -Photocell- Sensor -6

EN Guarantee

  • We take special care to select high-quality materials and use manufacturing techniques that allow us to create products incorporating design and durability. This product LAP has a manufacturer’s guarantee of 3 years against manufacturing defects, from the date of purchase (if bought in store) or date of delivery (if bought online), at no additional cost for normal (non-professional or commercial) household use.

  • To make a claim under this guarantee, you must present your proof of purchase
    (such as a sales receipt, purchase invoice or other evidence admissible under applicable law), please keep your proof of purchase in a safe place. For this guarantee to apply, the product you purchased must be new, it will not apply to second-hand or display products. Unless stated otherwise by applicable law, any replacement product issued under this guarantee will only be guaranteed until expiry of the original period guarantee period.

  • This guarantee covers product failures and malfunctions provided the product was used for the purpose for which it is intended and subject to installation, cleaning, care and maintenance in accordance with the information contained in these terms and conditions, in the user manual and standard practice, provided that standard practice does not conflict with the user manual.

  • This guarantee does not cover defects and damage caused by normal wear and tear or damage that could be the result of improper use, faulty installation or assembly, neglect, accident, misuse, or modification of the product. Unless stated otherwise by applicable law, this guarantee will not cover, in any case, ancillary costs (shipping, movement, costs of uninstalling and reinstalling, labour etc), or direct and indirect damage.

  • If the product is defective, we will, within a reasonable time, replace or refund.

  • Rights under this guarantee are enforceable in the country in which you purchased this product. Guarantee related queries should be addressed to the store you purchased this product from.

  • The guarantee is in addition to and does not affect your statutory rights.

Safety

  • All fittings must be installed by a competent person in accordance with local regulations (IET wiring regulation BS7671).
  • Check the pack and make sure you have all of the parts listed.
  • Decide on the appropriate location for your product.
  • The lamp should be placed on a flat, dry and clean surface. Do not allow the lamp to be covered; keep clear of curtains and bedding, etc.
  • he product must be securely fixed to the mounting surface using the screws and wall plugs supplied. The screws and wall plugs supplied are suitable for “masonry” only. Other fixings not supplied and must be purchased.
  • Take care not to drill into any pipes or mains cables beneath the surface during mounting holes preparation.
  • Do not position or place the product near to heaters, flame or any other direct sources of heat.
  • The appliance must be supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30 mA.
  • his product is rated IP44 (splash proof). It is suitable for use outdoors but should not be immersed in water / sited in areas likely to be heavily splashed, either from above or below, or subjected to standing water.
  • This product is suitable for positioning on surfaces which have normal flammability e.g. wood, plasterboard or masonry. However this does not include highly flammable surfaces(e.g. polystyrene or textiles).
  • Wiring diagram is for reference only. Always refer to the terminal marking for wiring. Ensure that all electrical connections are tight and that no loose strands are left out of the terminal block.
  • Never put anything on the product or hang anything on any part of this product.
  • IMPORTANT: Always switch off the mains supply during installation or maintenance. We recommend that the fuse is withdrawn or the circuit breaker switched off at the distribution board whilst work is in progress (turning off the light switch is not sufficient).
  • Connection should be via a wall switch to enable safe isolation.
  • Never use the terminal cables to bear the product’s weight.

Troubleshooting

LAP RD0006 -Indoor- and- Outdoor- Black -Photocell- Sensor
-10
Technical Data

  • Supply Voltage:
    • 220-240 V~, 50/60 Hz
  • Max. switching capacity:
    • 1500 W for incandescent;
    • 600 W for fluorescent;
    • 200 W for LED (max. 8)
  • Conformity with all relevant EC Directive requirements.
  • Conformity with all relevant UK legislation requirements.
  • Splash-proof
  • Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your Local Authority or local store for recycling advice.
  • Do not use with a dimmer switch.
  • xx-year; yy-week of the year

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

LAP User Manuals

Related Manuals