LAP 2967 Series IndoPro Recessed LED Downlight Instruction Manual

June 12, 2024
LAP

2967 Series IndoPro Recessed LED Downlight
Instruction Manual

2967 Series IndoPro Recessed LED Downlight

Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory operation of this product. Please retain these instructions for future reference.

Warning

  • All fittings must be installed by a competent person in accordance with local regulations (IET wiring regulation BS7671).
  • Check the pack and make sure you have all of the parts listed. Remove all packaging, wrap etc from the product. Decide on the appropriate location for your product.
  • This product is colour changing and can be either warm white(3000K) or cool white(5000K). Choose your preferred colour before installing by flicking the switch on back of the product.
  • To prevent electrocution switch off at mains supply before installing or maintaining this fitting. Ensure other persons cannot restore the electrical supply without your knowledge. If you are in any doubt, please consult a qualified electrician.
  • IMPORTANT: The fixing point(s) selected must be capable of supporting the full weight of the light fitting.
  • It is always recommended to cut the hole slightly smaller than the size specified, and then file the hole until the recessed unit fits snugly.
  • Wiring diagram is for reference only. Always refer to the terminal marking for wiring. Ensure that all electrical connections are tight and that no loose strands are left out of the terminal block.
  • Never use the terminal cables to bear the product weight.
  • Ensure the ceiling surface is flat and smooth to ensure a good seal.
  • The external flexible cable or cord of this luminaire cannot be replaced; if the cord is damaged, the luminaire must be destroyed.
  • These products are suitable for use in 30, 60 or 90 minute fire rated ceilings.
  • The minimum ceiling void depth is 75mm. When more than one downlight is installed, the minimum distance between units is 300mm. The minimum distance between a unit and the wall is 120mm.

Technical information

Supply Voltage: 220-240 V∼, 50 Hz
Bulb Type: LED (9 W). The light source of this luminaire is not

replaceable; when the light source reaches its end of life the whole luminaire shall be replaced. Do not stare at the operating light source.
| Conformity with all relevant EC directive requirements.
| Conformity with all relevant UK legislation requirements.
| Class II product – This light fitting is double insulated and does not require connection to an earth circuit.
| For indoor use only.
| Minimum distance from lighted objects (0.3 metres).
| Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your Local Authority or local store for recycling advice.
xxWyy| xx-year; yy-week of the year

Non-replaceable light source

Replaceable control gear by a professional

This product contains a light source of energy efficiency class G. For further information please visit: www.lighting-info.co.uk/74024

Bathroom Installation

The IP rating of the front of product is IP65 and the rest of product (switch on back of product & driver) is IP20. Always refer to the reference drawing and IP rating of surround for bathroom (Fig.1).
This product is suitable for bathroom hazard zones as specified by the following water drop image.
Warning: this drawing is for reference only. Consult a professional electrician to install according to relevant national wiring rules. If being fitted in a bathroom a 30mA RCD must be used.

|
---|---

Manufacturer
UK Manufacturer:
Kingfisher International Products Limited
3 Sheldon Square, London, W2 6PX,
United Kingdom
EU Manufacturer:
Kingfisher International Products B.V.
Rapenburgerstraat 175E,
1011 VM Amsterdam,
The Netherlands
www.kingfisher.com/products
www.diy.com
www.screwfix.com
www.screwfix.ie
To view instruction manuals online, visit www.kingfisher.com/products

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

LAP User Manuals

Related Manuals