smartbitt 1200va UPS System User Manual

June 5, 2024
smartbitt

smartbitt 1200va UPS System

smartbitt 1200va UPS System-prod

Read all the safety instructions

carefully to correctly and safely use and operate Smartbitt UPS To avoid electric shock hazard or fire risk, place your UPS in an area where temperature and humidity don’t exceed the operative parameters of your UPS and make sure the environment is free of conductive or combustible contaminants. To reduce overheating risk of your UPS, do not cover the ventilation slots, avoid continuous exposure to direct sunlight and don’t place it near appliances that produce heat like heaters or boilers. Do not connect devices or appliances functioning with alternating current motors, like drills, chainsaws, microwaves, vacuum cleaners, refrigerators, or medical, vital support or industrial equipment. Do not connect your UPS to a surge protector, power strip or AVR. Do not power on your UPS with its power cord connected to its own power outlets. Do not expose to liquids that may leak inside the device. In case of emergency, press the power button making sure that the UPS shuts down, then disconnect its power cord from the AC outlet. Disconnect the UPS before cleaning it, do not use liquid detergent or scouring powder. Do not try to replace batteries, please contact Smartbitt Technical Support to get information about battery replacement. Only qualified personnel should replace batteries in case it is required. Replacement must be done with caution. The same kind and capacity of batteries shall be used.Nonauthorized personnel should abstain from making the replacement. Batteries must not be exposed to fire and have to be disposed of properly. Mistreat of the batteries can cause them to explode. The materials contained inside the batteries is dangerous for eyes and skin, in case of contact with these materials, rinse thoroughly and consult your doctor immediately.

ELECTRIC SHOCK HAZARD

DURING BATTERIES REPLACEMENT

In case of requiring battery replacement, please contact our Technical Support where you will be advised on the issue. This product meets with the actual European Union environmental and security regulations. If you need any further information about this or any other issue, do not hesitate to contact us, an expert will provide the necessary care.

WHAT’S IN THE BOX

The box should include the following elements:smartbitt 1200va UPS
System-fig1

Thanks for purchase Smartbitt Products.

Your UPS is an uninterruptible power supply system with interactive technology. It is a device designed to protect your electronic devices and appliances which are sensitive to different power faults and interferences, including total power fail. This device is equipped with various technologies capable of making your electric devices to work properly for extra timesmartbitt 1200va UPS System-fig3

Important Note.
Before installation, inspect the unit. Make sure that none of the elements in the box is damaged. In case you find any damaged part, please contact your vendor.

SBNB500

  1. Switch On / Off Button
  2. LED’S Status indicator
  3. Electronic Breaker
  4. Power Cord
  5. Four Outlets (With Backup)

SBNB750 /1000USB

  1. Switch On/Off Button
  2. LED’S Status Indicator
  3. Phone Line Protector
  4. Electronic Breaker
  5. Power Cord
  6. Six Outlets (With Backup)
  7. USB Port (USB models)

SBNB1200

  1. Switch On /Oft Button
  2. LED’s Status Indicator
  3. USB Port for Monitoring Software
  4. Power Cord
  5. Electronic Breaker
  6. Phone Line Protector
  7. Eight Outlets (With Backup)
  • Installation and Storage Conditions.smartbitt 1200va UPS System-fig7
    Place your UPS in a protected area, free from excesive dust and adequate ventilation. To avoid any interference, do not place your UPS less than 20 ems away from other devices.
    Do not power on your UPS where temperature exceeds 40°C degrees or relative humidity is above 90%.

  • Connection to power outlet and first battery charge.
    Connect the plug of your UPS to the power outlet. To get the best performance of the battery, we suggest to charge it for 8 hours before its first use, afterwards, the UPS will charge its battery automatically while it’s connected to the electrical network.

  • Power on/off of the UPSsmartbitt 1200va UPS System-fig8
    Hold the power button for 3 seconds for either power on or shut down your UPS.

  • Connection of your devices to the UPS
    Connect your devices to the power outlets on the rear panel of your UPS. After this, when you power on your UPS your devices will be protected.

DO NOT CONNECT A POWER STRIP, SURGE PROTECTOR OR AVR TO THE UPS OUTLETS.

  • Connection of the telephone line protector.
    Connect the telephone line to one of the connectors in the rear panel of your UPS. Connect a telephone cable to the remaining connector available and to the device you are willing to protect.

    • THIS DOES NOT APPLY FOR MODELS WITHOUT TELEPHONE LINE PROTECTION
  • Connection of the USB interface cable.
    This function allows you to control and monitor your UPS through the included software. Connect the USB cable to the USB port of your computer.

    • APPLIES ONLY WITH USB COMPATIBLE MODELS

IMPORTANT
Never connect a laser printer to your UPS, input current generated from this kind of devices could damage your UPS. Do not connect either appliances with alternating current motors such as drills, chainsaws, etc.

AUDIBLE ALAMARS

TO HELP YOU TO IDENTIFY COMMON UPS PROBLEMS.

The UPS features an audible alarm which indicates when it is in a different status than normal, description of the audible alarms is as follows:smartbitt 1200va UPS System-fig14

Troubleshooting

PROBLEM POSSIBLE CAUSE ACTION

LED status indicators not turning on

| Low Battery| Charge the UPS for at least 8 hours without any connected devices.
Battery Failure| Replace battery, please contact Technical Support.
UPS not turned on| Press power on button, make sure that the UPS is correctly

Alarm continuously active

|

A tone every 10 seconds. Power outage

|

If there’s not a power outage, make su the UPS is correctly connected to the power source.

A tone every second. Low Battery| Charge the UPS for at least 8 hours without any connected devices.

If after this, the problem continues, contact Technical Support for battery diagnosis and replacement.

A tone every 0.5 seconds. Overload

|

Disconnect devices from your UPS un the total load of connected devices is below the UPS maximum capacity.

Make sure your devices not exceed the maximum capacity.

A tone every 2 seconds. Battery fail.

|

Contact Technical support for diagnos and possible battery replacement.

A continuous tone. Unknown failure

|

Contact Technical Support

PROBLEM POSSIBLE CAUSE ACTION

During power outage, battery lasts too little.

|

UPS Overload

|

Disconnect some devices and verify the connected devices load do

not exceed the UPS capacity.

Battery voltage is too low

|

Charge the UPS for 8 hours without any devices connected .

Battery life is depleted

|

Replace battery.

Contact Technical Support.

UPS functioning in backup mode without a power outage

|

Power cord is not correctly connected or it’s broken.

|

Make sure the power cord is correctly connected to the power source,

if this is not the problem, contact Technical Support.

Technical Specifications

smartbitt 1200va UPS System-
fig15

The backup time may vary depending on the load connected to UPS.

Consumption Table

Phone Mobil Charger average consumption SW
Multichannel Amplificator average consumption 120W
Audio Minicomponent average consumption 60W
Scanner average consumption lSOW
Printer Inkjet Printers 27W
PC (monitor) CRT promedio 17 inches 70W
PC (monitor) LCD, 19 inches 100W
PC (monitor) LCD, 21 inches 120W
PC Netbook 10.1 inches 40W
PC LapTop 15 inches 6SW
PC Desktop (CPU) average consumption 170W
PC Tower average consumption 400W
PC iMac (CPU) Apple 36SW
Digital Clock average consumption SW
DVD Player average consumption 3SW
Blu-Ray average consumption 60W
Switch/HUB 8 Ports 8W
lnalambric Phone (Dock) average consumption 2SW
TV CRT Color , 21″, average consumption 200W
TV LED, 32 inches 60W
TV LED, 40 inches 100W
TV LED, 55 inches 190W
TV LED, 60 inches 230W
TV LED, 80 inches 280W
TV LCD, 19 inches 3SW
TV LCD, 21 inches llSW
TV LCD, 32 inches 1S6W
TV LCD, 34 inches 200W
TV LCD 37 inches 236W
TV LCD, 42 inches 322W
TV LCD, 50 inches 464W
TV Plasma , 42 inches 474W
TV Plasma , 50-56 inches 18W
Video game Console Nintendo Wii 34W
Video game Console Nintendo Wii U 23W
Video game Console Playstation 5 230W
Video game Console PS2 194W
Video game Console PS3 237W
Video game Console PS4 270W
Video game Console Xbox Series X 200W
Video game Console Xbox 360 19SW
Video game Console Xbox ONE 212W

The calculation may vary according to the make and model of the electronic device.

Scan QR code to download datasheet product

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

smartbitt User Manuals

Related Manuals