UNI-T UPO3000E Series Digital Phosphor Oscilloscopes User Guide

June 9, 2024
UNI-T

UNI-T UPO3000E Series Digital Phosphor Oscilloscopes User Guide
UNI-T UPO3000E Series Digital Phosphor Oscilloscopes

Copyright Information
Uni-Trend Technology (China) Co., Ltd. All rights reserved.

Trademark Information
UNI-T is the registered trademark of Uni-Trend Technology (China) Co., Ltd.

Document Version
MSO/UPO300020221130-V1.00

Statement

  • UNI-T products are protected by patent rights in China and foreign countries, including issued and pending patents.
  • UNI-T reserves the rights to any product specification and pricing changes.
    UNI-T reserves all rights. Licensed software products are properties of Uni-Trend and its subsidiaries or suppliers, which are protected by national copyright laws and international treaty provisions. Information in this manual supersedes all previously published versions.

Safety Requirements

This section contains information and warnings that must be followed to keep the instrument operating under safety conditions. In addition, user should also follow the common safety procedures.

Safety Precautions

Warning

Please follow the following guidelines to avoid possible electric shock and risk to personal safety

Users must follow the following conventional safety precautions in operation, service and maintenance of this device. UNI-T will not be liable for any personal safety and property loss caused by the user’s failure to follow the following safety precautions. This device is designed for professional users and responsible organizations for measurement purposes.

Do not use this device in any way not specified by the manufacturer. This device is only for indoor use unless otherwise specified in the product manual.

Safety Statement

Warning

“Warning” indicates the presence of a hazard. It reminds users to pay attention to a certain operation process, operation method or similar. Personal injury or death may occur if the rules in the “Warning” statement are not properly executed or observed. Do not proceed to the next step until you fully understand and meet the conditions stated in the “Warning” statement.

Caution

“Caution” indicates the presence of a hazard. It reminds users to pay attention to a certain operation process, operation method or similar. Product damage or loss of important data may occur if the rules in the “Caution” statement are not properly executed or observed. Do not proceed to the next step until you fully understand and meet the conditions stated in the “Caution” statement

Note

“Note” indicates important information. It reminds users to pay attention to
procedures, methods and conditions, etc. The contents of the “Note” should be highlighted if necessary.

Safety Sign

| Danger| It indicates possible danger of electric shock, which may cause personal injury or death.
---|---|---
| Warning| It indicates that you should be careful to avoid personal injury orproduct damage.
| Caution| It indicates possible danger, which may cause damage to this device or other equipment if you fail to follow a certain procedure or condition. If the “Caution” sign is present, all conditions must bemet before you proceed to operation.
| Note| It indicates potential problems, which may cause failure of thisdevice if you fail to follow a certain procedure or condition. If the

|

| “Note” sign is present, all conditions must be met before thisdevice will function properly.
---|---|---
| AC| Alternating current of device. Please check the region’s voltagerange.
| DC| Direct current device. Please check the region’s voltage range.
| Grounding| Frame and chassis grounding terminal.
| Grounding| Protective grounding terminal.
| Grounding| Measure grounding terminal.
| OFF| Main power off.
| ON| Main power on.
| PowerSupply| Standby power supply: when the power switch is turned off, thisdevice is not completely disconnected from the AC power supply.
CAT I| Secondary electrical circuit connected to wall sockets through transformers or similar equipment, such as electronic instruments and electronic equipment; electronic equipment with protective measures, and any high-voltage and low-voltage circuits, such as the copier in the office

CAT II

| CATII: Primary electrical circuit of the electrical equipment connected to the indoor socket via the power cord, such as mobile tools, home appliances, etc. Household appliances, portable tools (e.g. electric drill), household sockets, sockets more than 10 meters away from CAT III circuit or sockets more than20 meters away from CAT IV circuit

CAT III

| Primary circuit of large equipment directly connected to the distribution board and circuit between the distribution board and the socket (three-phase distributor circuit includes a single commercial lighting circuit). Fixed equipment, such as multi-phase motor and multi-phase fuse box; lighting equipment and lines inside large buildings; machine tools and powerdistribution boards at industrial sites (workshops)
CAT IV| Three-phase public power unit and outdoor power supply line equipment. Equipment designed to “initial connection”, such as power distribution system of power station, power instrument, front-end overload protection, and anyoutdoor transmission line
| Certification| CE indicates a registered trademark of EU.
| Certification| UKCA indicates a registered trademark of UK.
| Certification| Conforms to UL STD 61010-1, 61010-2-030, Certified to CSA STD C22.2 No. 61010-1, 61010-2-030.
| Waste| Do not place equipment and its accessories in the trash. Items must be properly disposed of in accordance with local regulations.
|

EFUP

| This environment-friendly use period (EFUP) mark indicates that dangerous or toxic substances will not leak or cause damage within this indicated time period. The environment-friendly use period of this product is 40 years, during which it can be used safely. Upon expiration of this period, it should enter therecycling system.
---|---|---
Safety Requirements
Warning
Preparation before use| Please connect this device to AC power supply with the power cable provided; The AC input voltage of the line reaches the rated value of this device. See the product manual for specific rated value.The line voltage switch of this device matches the line voltage; The line voltage of the line fuse of this device is correct;It not used for measuring the main circuit.
Check all terminal rated values| Please check all rated values and marking instructions on the product to avoid fire and impact of excessive current. Please consult the product manual fordetailed rated values before connection.
Use the power cord properly| You can only use the special power cord for the instrument approved by the local and state standards. Please check whether the insulation layer of the cord is damaged or the cord is exposed, and test whether the cord is conductive. If the cord is damaged, please replace it before using theinstrument.
Instrument Grounding| To avoid electric shock, the grounding conductor must be connected to the ground. This product is grounded through the grounding conductor of thepower supply. Please be sure to ground this product before it is powered on.
AC power supply| Please use the AC power supply specified for this device. Please use the power cord approved by your country and confirm that the insulation layer isnot damaged.
Electrostatic prevention| This device may be damaged by static electricity, so it should be tested in the anti-static area if possible. Before the power cable is connected to this device, the internal and external conductors should be grounded briefly to release static electricity. The protection grade of this device is 4 kV forcontact discharge and 8 kV for air discharge.
Measurement accessories| Measurement accessories are of lower class, which are definitely not applicable to main power supply measurement, CAT II, CAT III or CAT IV circuit measurement .Probe subassemblies and accessories within the range of IEC 61010-031 and current sensor within the range of IEC 61010-2-032 can meetits requirements.
Use the input / output port of this device properly| Please use the input / output ports provided by this device in a properly manner. Do not load any input signal at the output port of this device. Do not load any signal that does not reach the rated value at the input port of this device. The probe or other connection accessories should be effectively grounded to avoid product damage or abnormal function. Please refer to theproduct manual for the rated value of the input / output port of this device.
Power fuse| Please use power fuse of specified specification. If the fuse needs to bereplaced, it must be replaced by maintenance personnel authorized by UNI-T to replace the fuse that meets the specified specifications.
---|---
Disassembly and cleaning| There are no components available to operators inside. Do not remove the protective cover.
Maintenance must be carried out by qualified personnel.
Service environment| This device should be used indoors in a clean and dry environment with ambient temperature from 0 ℃ to 40 ℃.Do not use this device in explosive, dusty or humid air.
Do not operate in humidenvironment| Do not use this device in a humid environment to avoid the risk of internalshort circuit or electric shock.
Do not operate inflammable and explosive environment| Do not use this device in a flammable and explosive environment to avoid product damage or personal injury.
Caution
Abnormality| If this device may be faulty, please contact the authorized maintenance personnel of UNI-T for testing. Any maintenance, adjustment or partsreplacement must be done by the relevant personnel of UNI-T.
Cooling| Do not block the ventilation holes at the side and back of this device;Do not allow any external objects to enter this device via ventilation holes; Please ensure adequate ventilation, and leave a gap of at least 15 cm on both sides, front and back of this device.
Safe transportation| Please transport this device safely to prevent it from sliding, which maydamage the buttons, knobs or interfaces on the instrument panel.
Proper ventilation| Poor ventilation will cause the device temperature to rise, thus causing damage to this device. Please keep proper ventilation during use, andregularly check the vents and fans.
Keep clean and dry| Please take actions to avoid dust or moisture in the air affecting theperformance of this device. Please keep the product surface clean and dry.
Note
Calibration| The recommended calibration period is one year. Calibration should only becarried out by qualified personnel.

Introduction of MSO/UPO3000E Series

MSO/UPO3000E series digital phosphor oscilloscope includes ten models

Model Analog Channel Analog bandwidth LA AWG
UPO3354E 4 350MHz ×
UPO3352E 2 350MHz ×
UPO3504E 4 500MHz ×
UPO3502E 2 500MHz ×
MSO3354E 4 350MHz ×
MSO3352E 2 350MHz ×
MSO3504E 4 500MHz ×
MSO3502E 2 500MHz ×
MSO3354E-S 4 350MHz
MSO3504E-S 4 500MHz

●:Standard ○: Optional ×: Not support

Getting Started Guide

This chapter introduces on using the oscilloscope for the first time, the front and rear panels, the user interface, as well as the built-in help system.

General Inspection

It is recommended to inspect the instrument follow the steps below before using the MSO/UPO3000E series for the first time.

  1. Check for Damages caused by Transport
    If the packaging carton or the foam plastic cushions are severely damaged, please contact the UNI-T distributor of this product immediately.

  2. Check Attachment
    Please check appendix for the list of accessories. If any of the accessories are missing or damaged, please contact UNI-T or local distributors of this product.

  3. Machine Inspection
    If the instrument appears to be damaged, not working properly, or has failed the functionality test, please contact UNI-T or local distributors of this product.

If the equipment is damaged due to shipping, please keep the packaging and notify both the transportation department and UNI-T distributors, UNI-T will arrange maintenance or replacement.

Before Use

To perform a quick verification of the instrument’s normal operations, please follow the steps below:

  1. Connect to the Power Supply
    The power supply voltage range is from 100 VAC to 240 VAC, the frequency range is 50 Hz to 60 Hz. Connect the oscilloscope to the power supply line that came with the oscilloscope or any power supply line that meets the local country standards. If the power switch on the rear panel is not turned on, the indicator of power soft button on the left corner on the front panel will be extinguished and no function. If the power switch on the rear panel is turned on, the indicator of power soft button on the left corner on the front panel will be on red, press this button to boot-up the instrument.

  2. Boot-up Check
    Press the soft power button and the light should change to green. The oscilloscope will show a boot animation, and then enter the normal interface.

  3. Connect Probe
    Use probe’s BNC port connect to the channel 1 BNC port of the oscilloscope. Connect the probe to the “Compensating signal port” and the ground clip is connected to the “Ground terminal” below the compensating signal port as shown in Figure 1. The output of the compensating signal should be amplitude 3 Vpp, default frequency is 1 kHz
    Figure 1 Compensating signal and Ground terminal
    Compensating

  4. Function Check
    Press the AUTO key, a 3 Vpp 1 kHz square wave should appear. Repeat step 3 to check all channels.

  5. Probe Compensation
    When the probe is connected to any input channel for the first time, this step might be adjusted in order to match the probe and the input channel. Probes that are not compensated may lead to measurement errors or mistake. If need to adjust the probe compensation, please follow the following steps:

  • Set the attenuation coefficient in the probe menu and the switch on the probe 10x, and connect the probe to CH1. Make sure the probe’s connector is properly connected with the oscilloscope. Connect the probe’s main clip and ground clip to the oscilloscope’s compensating signal and ground terminal respectively. Open CH1 and press the AUTO button.

  • View the displayed waveform, as shown in Figure 2
    Excessive Compensation Correct Compensation Insufficient Compensation
    Figure 2 Compensating Calibration of Probe
    Symbol

  • If the displayed waveform is look like the above “Insufficient Compensation” or “Excessive Compensation”, use a non-metallic screwdriver to adjust the probe’s variable capacitance until the display matches the “Correct compensation” waveform.

Warning: To avoid electric shock when using the probe to measure high voltage, please ensure that the probe insulation is in good condition and avoid physical contact with any metallic part of the probe.

Front Panel

Front Panel

Figure 3 Front Panel

Table 1 Front Panel

No. Description No. Description
1 Screen display area 12 Factory setting, LA, AWG, protocol decoding
2 Multipurpose knob 13 Trigger control (TRIGGER)
3 Recording waveform 14 Horizontal control (HORIZONTAL)
4 Jog dial knob 15 Analog channel input port
5 Function menu 16 Vertical control (VERTICAL)
6 Numeric keypad 17 Menu control soft key
7 Automatic control key 18 USB HOST interface
8 Run/Stop control key 19 Power supply soft key
9 Single trigger control key 20 Digital channel input port
10 Clear all control key 21 HOME menu
11 Compensating signal connector and ground terminal

Rear Panel

Rear Panel

Figure 4 Rear Panel

Table 2 Rear Panel

No. Description No. Description
1 EXT Trig port 5 LAN
2 AUX Out and arbitrary waveform signal output 6 AC Power Input Socket
3 VIDEO Out 7 Power Switch
4 USB Device port 8 Safety Lock

User Interface

Figure 5 User Interface

User Interface

Table 3 User Interface

No. Description No. Description
1 Trigger status identification 9 System time
2 Time base scale 10 USB DEVICE icon
3 Sampling rate/storage depth 11 CH4 state icon
4 Waveform indicator 12 CH3 state icon
5 Waveform trigger position 13 CH2 state icon
6 Horizontal displacement 14 CH1 state icon
7 Trigger status 15 HOME menu
8 Operation menu 16 Analog channel icon and waveform

Touch Screen

MSO/UPO3000E series provides 8 inch super capacitive touch screen, multiple point touch control and
gesture control. MSO/UPO3000E has easily operating system with flexible and high sensitive touch screen
features for great waveform display and excellent user experience. Touch control function includes tap,
squeeze, drag and drawing rectangle.

Hint : The menu displayed on the screen of the oscilloscope can all use the touch control function.

  • Tap
  • Squeeze
  • Drag
  • Drawing Rectangle
  • Touch Shortcut Operating

Tap

Use one finger to slightly tap icon or word on the screen as shown in Figure 7. Tap can use for:

  • Tap menu displayed on the screen and then to setup.
  • Tap the function guide icon on the left corner of the screen to enable it.
  • Tap to pop out numeric keypad to set parameter.
  • Tap virtual keyboard to set label and file name.
  • Tap message to pop out close button on the right corner to close it.
  • Tap other window displayed on the screen to setup

Figure 7 Touch Gesture

Squeeze

Squeeze two fingers together or separate. Squeeze gesture can zoom out or zoom in the waveform. If the waveform need to zoom out, squeeze two finger together and then slide away; If the waveform need to zoom out, separate two fingers and then squeeze two fingers together as shown in Figure 8. Squeeze gesture can use for:

  • Adjusting horizontal time base of waveform on the horizontal direction.
  • Adjusting vertical scale of waveform on the vertical direction.

Figure 8 Squeeze Gesture

Drag

Use one finger to press and drag the selected item to the aimed position as shown in Figure 9. Drag gesture
can use for:

  • Drag waveform to change waveform displacement or offset.
  • Drag window control to change window position (such as numeric keyboard).
  • Drag cursor to change cursor position.

Figure 9 Drag Gesture
\

Drawing Rectangle

Open function guide and tap drawing rectangle icon to switch drawing rectangle mode. Drag finger on the screen to drawing rectangle as shown in Figure 10(a), 10(b). Move finger away from the screen, menu displayed on the screen, tap to select “Area A enable”, “Area B enable”, “Intersection”, “Non intersecting”, “Source”. Drag finger on the screen form bottom right up to top left to drawing the trigger area.

Figure 10 Drawing Rectangle Gesture
Drawing Rectangle Gesture

Select “Area A”:

  • Drawing the area of trigger area A;
  • Open trigger area A;
  • Open “trigger area” menu.

Select “Area B”:

  • Drawing the area of trigger area B;
  • Open trigger area B;
  • Open “trigger area” menu.

Hints: Press “drawing rectangle” icon to switch drawing rectangle and operating waveform mode. Press “drawing rectangle” icon, if icon displays , which presents the drawing rectangle mode is opened; press “drawing rectangle” **** icon, if icon displays , which presents the operating waveform mode is opened. Operating waveform mode of the oscilloscope is enabled by default.

Touch Shortcut Operating

Separate two fingers and meanwhile slide two fingers to one direction, this gesture can quickly turn on/off time measurement and voltage measurement cursor.

a. Time measurement cursor

  • Slide down in vertical to directly turn on time measurement cursor as shown in Figure 11 (a);
  • Slide up in vertical to directly turn off time measurement cursor;
    Touch Shortcut Operating

b. Voltage measurement cursor

  • Slide right in horizontal to directly turn on voltage measurement cursor as shown in Figure 11 (b);
  • Slide left in horizontal to directly turn off voltage measurement cursor;
    Touch Shortcut Operating

Note: Turn on/off cursor requires that slide distance should be >3div.

c. Quick Guide
When the oscilloscope is stop, touch and drag the T identifier to left or right around quickly, or rotate the horizontal Position knob, a quick guide icon will displayed at the top of the screen, as shown in Figure 12. The quick guide icon can be closed when the oscilloscope is operating. In quick guide, the oscilloscope will automatically adjust the delay on horizontal direction at a constant speed according to the user-defined, it
is convenient for user to observe the waveform.

Press the guide key on the front panel, it can adjust to play forward, stop or backward. When in guiding, press Multipurpose knob can also stop the guide.
Quick Guide

Operation Menu

Press any soft key to activate the corresponding menu; the following icon may be displayed on the menu.

This symbol represents that multipurpose knob on the front panel can be used to select and adjust parameter.
This symbol represents that there are several options.
This symbol represents that there has next menu.
This symbol represents that the menu has two options.
This symbol represents that multipurpose knob and jog dial on the front panel can This symbol represents that numeric keypad on the front panel or touch to pop out numeric keyboard to input content.
This symbol represents that the current page can be flipped up or down.
Circle numbers represents the total pages of menu. Single page has no circle display, two pages or more have circle display. Use key to turn page.

Remote Control

MSO/UPO3000E series digital phosphor oscilloscope communicates with the computer through USB interface and LAN interface to achieve remote control. Remote control is implemented based on the SCPI (Standard Commands for Programmable Instruments) command set.

MSO/UPO3000E series digital phosphor oscilloscope supports three remote control modes:

a. User-defined programming
b. Use PC software (instrument manager)
c. Web Control

Troubleshooting

  1. When press the button, the oscilloscope is blank screen.
    a. Check whether the power is correctly connected, power supply is normal or not.
    b. Check whether the power switch is really turned on. The soft power switch button should light in green when the instrument is normal boot. And it should have relay sound.
    c. If there is a relay sound, it indicates that the oscilloscope starts normally. Try the following steps: press the DEFAULT key, then press F1, if device returns to normal, it means backlight brightness is set too low.
    d. After completing the above steps, restart the oscilloscope.
    e. If the instrument still cannot work, please contact UNI-T.

  2. After signal acquisition, signal of waveform does not appear on the screen.
    a. Check whether BNC port is connected properly.
    b. Check whether the signal output channel has turned on.
    c. Check whether the input signal channel has turned on.
    d. Check whether has DC displacement in signal of information source.
    e. Plug out the input signal, check whether the baseline is in the screen range (if not, please perform auto-calibration.)
    f. If the instrument still cannot work, please contact UNI-T.

  3. The measured voltage amplitude value is 10 times larger or smaller than the actual value: Check the channel probe attenuation coefficient setting is consistent with the used probe attenuation rate.

  4. There is a waveform display but not stable
    a. Check the trigger source in the trigger menu and confirm that it matches the input channel of the actual signal.
    b. Check the trigger type: general signal should use “Edge” trigger. The waveform can display stably only the proper trigger type is used.
    c. Change the trigger coupling setting to high-frequency or low-frequency reject, in order to filter out the high-frequency or low-frequency noise that interferes with the trigger.

  5. No display after pressing Run/Stop button
    a. Check whether the mode at the trigger panel (TRIGGER) is on “Normal” or “Single” and whether the trigger level exceeds the waveform range.
    b. If it exceeds,set the trigger level to the middle or set the trigger mode to Auto.
    c. Press AUTO button could automatically finish the above setting.

  6. Waveform refresh is very slow:
    a. Check whether the acquisition method is average and the average times are large.
    b. Check whether the storage depth is the maximum.
    c. Check whether the trigger release time is large.
    d. Check whether the trigger is normal and the current time base is slow.
    e. All the preceding causes slow refreshing of waveforms. Users can restore the factory settings so that the waveforms can be refreshed normally.

Appendix Contact Us

If the use of this product has caused any inconvenience, if you in mainland China, you can contact UNI-T company directly.

Service support: 8am to 5.30pm (UTC+8), Monday to Friday or via email. Our email address is [email protected]

For product support outside mainland China, please contact your local UNI-T distributor or sales center.

Many UNI-T products have the option of extending the warranty and calibration period, please contact your local UNI-T dealer or sales center.

To obtain the address list of our service centers, please visit our official website http://www.unitrend.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

UNI-T User Manuals

Related Manuals