welltherm PB0210 Powder-Coated Metal Infrared Heaters Installation Guide
- June 5, 2024
- welltherm
Table of Contents
welltherm PB0210 Powder-Coated Metal Infrared Heaters
In addition to this installation guide and the operating manual, our Youtube
channel also has a number of explanatory videos relevant to the
“Assembly” and “Electrical connection” chapters.
Video-URL:video.welltherm.de
The adjacent QR code can also be used to access the videos.
Safety
Please read this installation guide and operating manual carefully.
Take good care of this manual as well as any accompanying documentation. Make
sure all documentation accompanies the heater if you decide to pass it on to
someone else.
Action-related warnings
Classification of the action-related warnings: The action-related warnings are graded as follows with warning signs and signal words relating to the severity of the potential hazard:
Intended use
Improper use or use not as intended may result in dan-ger to the life and limb
of the user or third parties or cause damage to the product and other material
damages.
The product is used to increase the room temperature in closed residential
spaces.
Proper use includes:
- Observing the enclosed operating instructions for the product and all other system components.
- Installation and assembly in accordance with the product and system certification.
- Compliance with all inspection and maintenance conditions listed in the manual.
Keeping children younger than 3 years of age away from the system, unless they
are constantly supervised.
Children above 3 years of age and younger than 8 may only switch the product
on/off if they are supervised or have been instructed in the safe use of the
product and fully understand the resulting hazards that may occur, assuming
that the product is placed or installed in its normal position of use.
Children above 3 years of age and younger than 8 must not insert the plug into
the power socket, adjust the product, clean the product nor should they
perform maintenance as the user of the product.
Caution
- some product parts can get very hot and cause burns. Special care should be taken if children and vulnerable persons are present.
- Children should not be allowed to play with the product.
- Any use other than what is described in this manual or use going beyond what is listed here shall be considered improper.
- Proper use also covers installation in accordance with the IP class.
- Improper use also includes any type of direct commercial or industrial use.
- Attention! Any unauthorized use is prohibited.
General
Safety information: Danger due to incorrect operation
Incorrect operation may endanger you and others around you and cause material damage.
- Carefully read through this manual and all accompanying documentation, especially Chapter “1 Safety” and the warning information.
- Only carry out those activities that this operating manual instructs you to do.
Risk of material damage due to overheating: Ensure that the product is not covered or clad.
Danger due to inadequate qualification: Only personnel with sufficient qualification for the task in hand may carry out the following work:
- Assembly
- Disassembly
- Installation
- Commissioning
- Inspection and maintenance
- Repairs
- Decommissioning
- Observe all product-related instructions.
- Proceed in accordance with the current state-of-the-art.
- Comply with all relevant guidelines, norms, laws, and other provisions
Danger to life due to electric shock
A danger to life due to electric shock exists whenever live components are touched. Before working on the product:
- Unplug the power connector.
- Or de-energize the product by switching off all power supplies (electric isolator with at least a 3 mm contact opening, such as a fuse or circuit breaker).
- Secure against reconnection.
- Check for the absence of voltage.
Risk of burning or scalding due to hot components
Only work on components once they have cooled down.
Risk of material damage due to use of unsuitable tools
Use a specialist tool to tighten or loosen screw connections.
Provisions (guidelines, laws, norms)
Observe the national provisions, norms, guidelines and laws.
Product-related information
Notes on the documentation
Observe other applicable documents: Always observe all operating instructions that accompany the system components.
Keep the documents in a safe place: Retain this manual as well as all applicable documents for further use.
Validity of the manual: This manual is only applicable for:
Product description
The product is an infrared radiant heater that transfers heat to objects
through infrared radiation. The warmed objects then in turn give off heat to
the environment.
The product is equipped with a safety temperature limiter that switches off
the product in the event of overheating and automatically switches it back on
again once it has cooled down.
The product should be used in combination with the following components:
- Wireless thermostats X3D 310EL and X3D Minor 1000
- Wireless surface-mounted receiver X3D and wireless plug socket receiver X3D
- Opening detector X3D DO BL TYXAL
- Gateway TYDOM 1.0
The product is equally for mounting both on walls and ceilings.
The maximum surface temperature with an ambient temperature of 20°C is: 110 °C
(115 °C when mounted on a ceiling).
Product composition
The rear side of the heater sized 120 x 60 cm is depicted above.
Legend:
- Infrared heating
- Wall bracket (V bracket)
- Inlet connector for non-heating appliances
The CE marking documents that the products are in compliance with the fundamental requirements of the relevant guidelines in accordance with the nameplate.
The manufacturer retains the declaration of conformity, which can be viewed on request.
**Technical data
**
Assembly
Checking the completeness and condition of the delivery: Checking of the delivery for completeness and proper condition.
Dimensions
Requirements for the installation site
- Do not install the product immediately below a wall outlet.
- Do not install the product in rooms with excessive humidity.
- Do not install the product outside enclosed spaces or in areas where it could be exposed to water or moisture, e.g. swimming pool.
- Do not install the product or its connection socket with cables in the protection zone 0, 1 and 2 of wet areas.
- Do not install the product in rooms whose occupants can not vacate them independently, unless constant supervision can be ensured.
- Note that the room temperature should be at least 17°C and keep the fl oor areas and heaters clean in order to avoid any fogging effect.
**Minimum distances
**
- Make sure you do not fall below the minimum distance (C) between the rear wall and ceiling/wall predetermined by the fi xing brackets (V brackets).
- Ensure that continuous air circulation is possible between the rear wall and the ceiling/wall.
- Keep a minimum distance of 600 mm in all directions in areas of IP classes 44/65/67.
Installing the heater
Recommended tool
- A Cordless screwdriver or electric drill
- B Cutter knife or Stanley knife
- C Pencil or ballpoint pen
- D Hammer
- E Spanner with 8 mm WAF (open-end or ring)
- F Spanner with 10 mm WAF (open-end or ring)
- G 8 mm drill suitable for the material of your wall / ceiling
Assembly template
- Use the accompanying assembly template to determine the position of the drilling holes for product installation to the wall/ceiling. Always pay attention to the requirements for the installation site and the necessary minimum distances (see Page 10).
- We recommend using a spirit level when mounting onto a wall to ensure a vertical mounting position.
Assembly
-
First drill the required holes at the previously marked positions using an 8 mm drill suitable for the material of your wall or ceiling.
- Drill 4 holes for heaters up to max. 1,192 mm in length.
- Drill 6 holes for heaters from 1,200 mm in length.
The accompanying drilling template will also specify the number of holes. Please ensure correct positioning of the drilling
holes for optimum mounting of the wall bracket (V-brackets) to be screwed on later. Use (if suitable for the material of your wall /
ceiling) the supplied dowels, lag bolts and washers from the “Standard fi xing set” supplied with the heater -as shown on the left.
-
Insert the dowels into the holes (drive in with a hammer if necessary) and screw in the screws with washers using a 10 mm spanner. Do not completely tighten the screws. Make sure there is 4 mm of space be tween the washer and the wall / ceiling.
-
Check whether all wall brackets (V brackets) of your heater point in the same direction with the opening. If not, align the V-brackets uniformly in one direction. It doesn’t matter which direction it is.
In case of ceiling assembly, make sure the next assembly step is undertaken by two people. Have a ladder at hand (if required). -
Lift the heater to the mounting position so that the openings of the V-brackets are situated directly in front of the screws that are already in place.
-
Slide the heater sideways until the screws are fully engaged into the V-brackets. Pay attention to the washers.
-
Lock the heater in place by rotating the V-brackets 180º:
-
Tighten all 8 or 12 screws using both 8 and 10 mm spanners. Check the secure fi tting of the heater.
Electrical connection
Establishing the power supply
Caution! Risk of material damage due to excessive connection voltage!
Electronic components can be destroyed with mains voltages over 253 volts.
Ensure that the rated voltage of the mains is 230 volts.
The infrared heater has a three-wire connecting cable with a length of 1.9 m,
on the end of which a shockproof plug is fitted.
Observe the Ecodesign Directive
In accordance with the EU Ecodesign Directive 2009/125/EC – substantiated in
the Regulation 2015/1188 for the product range of local space heaters – this
infrared heater can only be operated as a stationary local space heater, if
certain requirements for control/regulation are fulfilled.
More detailed information can be found, for example, on the Internet at:
- https://www.umweltbundesamt.de/themen/wirtschaft-konsum/pro dukte/oekodesign/oekodesign-richtlinie
- http://eur-lex.europa.eu/legal-content/DE/ALL/?uri=CE
LEX%3A32015R1188
Welltherm GmbH offers a series of control components to fulfi l the requirements specifi ed above and for easy operation of this infrared heater. We will subsequently look at the electrical connection of these components.
Specification:
wireless plug socket receiver X3D: Insert the heater’s shockproof plug into the wireless plug socket receiver X3D for the power supply.
wireless receiver X3D: Attention! The optionally available wireless receiver X3D must only be electrically connected by qualifi ed electricians!
- Connect the phase conductor (live) of the mains network to terminal 4.
- Connect the neutral wire of the mains network to terminal 3.
- Connect terminal 2 to the blue connection cable of the infrared heater.
- Connect terminal 1 to the brown connection cable of the infrared heater.
- Connect the earth line of the mains network to the yellow-green connection cable of the infrared heater.
Operation
Commissioning the heater
Condition: Initial commissioning
Switch on the power supply to the heater.
- If you do not sense a feeling of warmth straight away, then leave the heater in operation for an extended period of time until the indoor climate becomes suitably pleasant.
- A pleasant feeling of warmth will be felt once all solid bodies have been heated.
- Activate all wireless control components that are to be used. Refer to their operating instructions on how to do this.
Troubleshooting
Id entifying and rectifying faults:
- Check whether the heater is covered or clad if it is not giving out any heat.
- In such a case it is possible that the safety temperature limiters in-tegrated into the heater have switched it off. If so, wait until after the heater has cooled down. The heater will automatically switch back on.
Maintenance
The surface colour of the heater may alter due to pollution in the indoor air,
such as from cigarette smoke, fireplace/stove residues or cooking fumes. Clean
the heater after it has cooled down and at regular intervals using a damp
cloth and some solvent-free soap.
Caution! There is a risk of material damage if unsuitable cleaning agents
are used!
Decommissioning the heater
Switch off the power supply to the heater.
Recycling and disposal
Please dispose of the packaging material properly. This heater contains materials and substances that are harmful to the environment.
- Do not dispose of the heater with household waste
- Take the heater to a collection point for electric or electronic waste instead.
Guarantee and customer service
Guarantee
Welltherm GmbH grants a 60 month guarantee to all customers who are consumers
of the product – irrespective of the statutory warranty.
This begins from the day the product is delivered and is valid nationwide.
The content of the guarantee is as follows: Should damage occur within 60
months from the date the product was delivered, and if it cannot be attributed
to improper use, Welltherm GmbH will strive to make repairs in accordance with
the conditions of Welltherm’s guarantee , which can be found at the end of the
German language operating manual. If repair work isn’t successful after a
second occasion, the device shall be replaced with a new one that is identical
in terms of its technical specifications. In the case of unavailability, the
customer shall be entitled to be supplied with a device from the Welltherm
range that is equivalent in terms of price and quality.
Price reduction, withdrawal from the purchase contract or claims for damages
are not part of the guarantee agreement. Any legal or contractual claims for
compensation are not affected by the guarantee.
The guarantee is issued by Welltherm GmbH, Wibschla 22, 58513 Lüdenscheid
Customer service
The customer service department at Welltherm GmbH can be contacted by phone,
fax, email and post:
Tel. No.: +49 2351 981 622 60
Fax: +49 2351 981 622-66
Email address: sales@welltherm.de
Postal address:
Welltherm GmbH
Wibschla 22
58513 Lüdenscheid
Welltherm GmbH Wibschla 22
58513 Lüdenscheid
t +49 (0) 2351 / 981 622-60 f +49 (0) 2351 / 981 622-66
sales@welltherm.de
www.welltherm.de
References
- YouTube
- Infrarotheizung - beste Qualität vom Spezialisten | welltherm
- Umweltbundesamt | Für Mensch und Umwelt
Read User Manual Online (PDF format)