CHAMPION Resetting The Maintenance Hour Meter Instruction Manual
- June 5, 2024
- Champion
Table of Contents
Resetting The Maintenance Hour Meter
Instruction Manual
The maintenance hour meter counts down 100 hours. Once completed the 100-hour
maintenance, refer to below to reset the hour meter.
Refer to the scheduled maintenance chart for specific maintenance.
-
Locate the aXis CONTROLLER.

-
Press OFF to take the generator off standby allowing you to enter setting mode.

-
Press and hold for five seconds to enter setting mode.

-
Cycle through until you reach maintenance hours by pressing the button. Look for the maintenance icon to be highlighted, lower right. Example shows 0 hours left for maintenance. Time for resetting the count-down clock.

-
Press and hold the AUTO button for approximately 5 seconds or until you see the hour meter reset to 100. Release button.

-
You have now reset the maintenance hour meter to 100 hours and can press OFF to exit.

-
Press AUTO once and the system goes into standby mode.

Read User Manual Online (PDF format)