URC MRX-30 Total Control

Introduction

The MRX-30 Advanced Network System Controller controls is designed to meet the needs of large residential or small commercial environments.
Only Total Control software, products, and user interfaces are supported by this powerful device.
This device is not compatible with Total Control 1.0 legacy products.

Features and Benefits

  • Stores and issues command for all IP, IR, RS-232, Relays, Sensors, and 12V Triggers controlled devices.
  • Provides two-way communication with Total Control user interfaces. (remotes and keypads).
  • Easy rack-mounting via the included rack-mounting ears.

URC MRX-30 Total Control - 1

Parts List
The MRX-30 Advanced Network Controller includes:

  • 1x MRX-30 System Controller
  • 1x AC Power Adapter
  • 1x Power Cord
  • 1x Adjustment Tool
  • 1x Ethernet Cable
  • 12x IR Emitters 3.5mm (standard)

Front Panel Description

The front panel consists of two (2) indicator lights that illuminate during usage:

  1. Power: Indicates that the MRX-30 is powered when illuminated.

  2. Ethernet: When the device has a valid Ethernet connection, the indicator light remains a solid blue.

  3. Status Light: Two (2) possible states:
    ■ Status Light On: Connected to LAN and internet.
    ■ Status Light Off: Connected to LAN, no internet or Ethernet cable has been unplugged.

  4. Reset Press once to power cycle the device.

URC MRX-30 Total Control - 2

Rear Panel Description

Below are the ports located at the rear of the MRX-30:

  1. Relays (NO, NC, or COM): Six (6) programmable relays.
  2. 12V OUT: Four (4) programmable outputs. Each port may be programmed to turn on, off, or momentarily toggle.
  3. Sensors: Six (6) programmable sensor ports, compatible with all URC sensors.
  4. Power: Attach the included power supply here.
  5. LAN: RJ45 10/100/1000 Ethernet port.
  6. IR Outputs: 12 standard 3.5mm IR emitter ports with variable output level adjustment screws
  7. RS-232: Six (6) RS-232 serial ports (TX, RX, and GND) for wired one-way or two-way communication.

URC MRX-30 Total Control - 3

Installing the MRX-30
The MRX-30 Advanced Network System Controller can be installed almost anywhere in the home.
Once physically installed, it requires programming by a certified URC integrator in order to operate local equipment using IP (Network), RS-232 (Serial), IR (Infrared), or
relays. All cables must be connected to their respective ports at the rear of the device.

Network Installation

1. Connect an Ethernet cable (RJ45) to the rear of the MRX-30 and the onto an available LAN port of the network’s local router (Luxul preferred).
2. A certified URC integrator is required for this step, configure the MRX-30 to a DHCP/MAC reservation within the local router.

URC MRX-30 Total Control - 4

Connecting IR Emitters
IR emitters are used to communicate to AV devices such as cable boxes, televisions, Blu-ray players, and more.

  1. Plug IR Emitters (twelve (12) supplied in the box) into any of the twelve (12) IR outputs available on the rear of the MRX-30.
    All IR outputs include an adjustable sensitivity dial. Turn this dial to the right to increase the gain and to the left to decrease it.

  2. Remove the adhesive covering from the emitter and place it over the IR receiver of the 3rd party device (cable box, television, etc.).

URC MRX-30 Total Control - 5

Connecting RS-232 (Serial)
The MRX-30 can operate equipment via RS-232 communication. This allows discrete serial commands to be triggered from the Total Control system.
Connect RS-232 devices using URC’s proprietary RS-232 cables. These use either male or female DB-9 connections with standard pin-outs.

  1. Connect the 3.5mm to the RS-232 Output available on the MRX-30.
  2. Connect the Serial connection to the available port on the 3rd party device, such as AVRs, Televisions, Matrix Switchers, and other devices.

URC MRX-30 Total Control - 6

Specifications

Network: One 10/100/1000M RJ45 Ethernet port (two LED indicators)
Weight: 99.15 oz
Size: 16.92” (W) x 3.7” (H) x 8.66” (D)
Power: DC 12V/3.3A
12V/.2A: Four (programmable)
IR Outputs: 12 Standard 3.5mm IR emitter ports (variable)
RS-232: Six supporting TX, RX, and GND
Sensors: Six programmable sensor ports

URC MRX-30 Total Control - 7

Limited Warranty Statement
https://www.urc-automation.com/legal/warranty-statement/
End User Agreement
The terms and conditions of the End User Agreement are available at
https://www.urc-automation.com/legal/end-user-agreement/ shall apply.
Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

GUMI UNIVERSITY EMC CENTER
TEST REPORT
Order Number: GETEC-C1-18-065
Test Report Number: GETEC-E2-18-011
Ts pe of Equipment: BASE STATION
Model Name: MRX-30
Applicant OHSUNG ELECTRONICS CO., LTD.
Applicant Address: 4181 Congdon-dong, Gumi-si, Gyeongsangbuk-do, Republic of Korea
Serial Nu other: Prototype
Date of Incoming: January 29, 2018
Date of Issue: February 20, 2018
SUMMARY
This device has been verified to comply with the requirement of the following regulations.
-EN 55032 (2015)
-AS/NZS aSPR 32 (2015)
-EN 61000-3-3 (2013)
-EN 55024 (2010) + AI (2015)
-EN 61000-3-2 (2014)

This test report only contains the result of a specific sample supplied for the examination.
It is not a generally valid assessment of the features of the respective products of the mass-production
This test report consists of 25 pages.
It is not allowed to copy this report even partly without the approval of the EMC center.
This test report should not be used to claim quality endorsement by KOLAS.
The test results in this report are traceable to the national or intentional standard.
URC MRX-30 Total Control - signature
Warning!

The manufacturer is not responsible for any Radio or TV interference caused by unauthorized modifications to this equipment.
Changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment.
Regulatory Information to the User

  • CE conformity Notice Products with “CE” marking comply with EMC Directive 2014/30/EU issued by the commission of the European Community.
    1. EMC Directive

    • Emission
    • Immunity
    • Power
  • Declaration of Conformity

“Hereby, Universal Remote Control Inc. declares that this MRX-30 is in compliance with the Essential requirements.”

**URC MRX-30 Total Control - icontechnical support
Toll-Free:800-904-0800
Main:914-835-4484
[
[email protected]](mailto:[email protected])
Hours: 9: 00 am – 5:00 pm ASTM-F**