HESSAIRE 1300 CFM Mobile Evaporative Cooler MC18 User Manual
- June 6, 2024
- HESSAIRE
Table of Contents
Mobile Evaporative Cooler
1300 CFM
Use & Care Guide
MC18
General Safety Precautions
Read and follow all instructions, cautions and warnings. Failure to do so
could result in personal injury, death or property damage.
Unit must be in OFF position and UNPLUGGED from power receptacle before
performing any maintenance/service or before REMOVING access panels.
Make sure the electrical power source conforms to the re- requirement of the
evaporative cooler as well as local codes.
To reduce risk of fire or electrical shock, do not expose electrical
connections to water.
Do not touch electrically live components.
Ensure all power cords do not touch sharp edges, hot surfaces or chemicals.
Immediately replace damaged parts.
Never leave unit unattended.
Continuous fill not to be used indoors or unattended.
Operation Tips
Hessaire coolers are highly recommended for outdoor use.
If used indoors, position cooler in front of window or open door for fresh
intake air. Ensure there is an open door or window through which the air can
exhaust from the room.
Clean media pads and tank frequently.
When shutting down unit, run without pump for 30 minutes to properly dry media
pads.
Inspection
After unpacking your cooler, carefully inspect for any damage 0that may have
occurred during transit. Inspect
for loose, missing or damaged parts.
Note : wheels & hose adapter are located on top of cooler upon the opening the box.
Contents: Evaporative Cooler (1), Hose Adapter (1), Caster Wheels (4).
Visit Hessaire.com to request replacement parts if any of these items are missing.
Quick Start
Note : Media pads may have a slight odor upon initial start up but will go away with continued use.
Features
Maintenance
WARNING
Disconnect from power source before attempting any maintenance or routine service. NEVER remove any access panels while cooler is in operation. Failure to do so could lead to SERIOUS INJURY
Cleaning Cooler & Rigid Media Pads:
The removable panel(s) & pads can be gently sprayed off to remove build up. A
soft bristle brush can also be used.
NEVER spray pads with water while cooler is in operation. Damage can occur to
the motor and will void the warranty.
Note : Vinegar is recommended for cleaning of cooler and can be
periodically cycled through during normal use. Removal Of Back Panel:
Disconnect power supply. Remove the two phillips screws from the upper back
side of cooler. Pull out top of back panel. Removal Of Rigid Media :
Once back is removed, the media pads will be accessible.
Note : some pads may be held in place with pins (media keepers) which
will need to be removed to free up the pads.
Storage :
Drain tank and wipe dry. Plug is located on bottom of cool- er. Ensure pads
are dry by running fan without pump for at least 30 minutes.
Visit Hessaire.com for additional maintenance tips and
service videos.
Troubleshooting
Problem
|
Cause / Remedy
---|---
Cooler won’t turn on| Ensure unit is plugged in and switched on.
Receptacle breaker may need to be reset.
If unit is equipped with a GFCI plug, reset.
If unit has a timer, ensure it is off.
May need new ON/OFF switch.
Fan will not operate
| Ensure fan function is on.
Make sure nothing is obstructing fan blade.
Fan motor may need to be replaced.
Fan switch may need to be replaced.
Slow running – may need capacitor replaced.
Cooler does not pump| Ensure pump switch is turned on.
Make sure water level is not low. Add water.
Make sure hoses are connected and free of debris.
Pump may need to be replaced.
Pump switch may need to be replaced.
Swing does not work| Ensure swing switch is turned on.
Make sure the linkage is connected.
Oscillation switch may need to be replaced.
Oscillation motor may need to be replaced.
Water leakage| Make sure drain plug is securely in place.
Make sure cooler is level.
Inspect tank for cracks.
Check media pads for water running on outside of unit.
Change pads if necessary.
Check for leaks in water distribution hose connections.
Check spreaders for build up causing spill over of water into the airstream.
Water level high or low| Adjust nut on float valve.
Float valve may need to be replaced.
Cooler Parts
| Parts| MC18
---|---|---
1| Pump| 6017050
2| Motor| 6017051
3| Rigid Media Panel| CP150
4| Control Knob & Switch| 6017069
5| Caster Set (4 pcs)| 6176100
6| Fan Blade| 6017052
7| Float Valve Kit (float valve, hose adapter)| 6018058
8| Manual fill door| 6017076
9| Drain plug| 6017081
Hessaire Warranty
Each new cooler is warrantied to be free from defects in material or workmanship for one full year from the date of original purchase. If a component(s) is found to be defective within this period, a Hessaire representative will replace the defective part free of charge. Parts are available through authorized dealers or online. Copy of proof of purchase and serial label will be needed for the warranty claim.
What is not covered:
Malfunctions resulting from misuse, negligence, alteration or lack of
necessary maintenance.
Loss of time, inconvenience, use of the product or other consequential damages
due to defects.
Return transportation costs. All return costs are the responsibility of the
purchaser.
Hessaire does not cover labor costs associated with troubleshooting or cooler
repairs regardless if the product is under warranty or not.
Damaged Shipments:
Hessaire is not responsible for damaged shipments or shortages resulting from
carrier mishandling. Notify
your carrier’s office immediately to file a freight claim in the event of
damage. Keep damaged product for inspection until advised by the carrier as to
disposal.
Returns :
Hessaire’s dealers shall implement a return policy that is consistent with the
dealer agreement. If the dealer’s return policy allows returns within a
specified time period—agreed to by Hessaire and dealer, the customer may
return the product to point of purchase. Dealer may reject, accept or accept
with a restocking fee at the sole discretion of the dealer. If the customer
wishes to repair the defective cooler, the customer can contact Hessaire fora
list of authorized repair centers for parts and troubleshooting. Defective
parts are provided free of charge within the warranty period.
Please DO NOT return your cooler to Hessaire. Upon authorization, any
returns should be sent directly to the distributor/store where purchased.
Visit hessaire.com for registration & warranty claim forms.