MAGMATIC LIG0017967-000 Magma Prime Water-Based Hazer HPA High Pressure Air Pump User Manual
- June 5, 2024
- MAGMATIC
Table of Contents
- INTRODUCTION
- LIMITED WARRANTY (USA ONLY)
- SAFETY GUIDELINES
- OVERVIEW
- SET UP
- CONTROL PANEL
- SYSTEM MENU
- DMX CHANNEL FUNCTIONS & VALUES
- DIMENSIONAL DRAWINGS
- TROUBLESHOOTING
- CLEANING & MAINTENANCE
- SPECIFICATIONS
- FCC STAT E M E N T
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
MAGMA PRIME
User Manual
©2020 MAGMATIC EFFECTS all rights reserved. Information, specifications,
diagrams, images, and instructions herein are subject to change without
notice. MAGMATIC EFFECTS logo and identifying product names and numbers herein
are trademarks of MAGMATIC EFFECTS. Copyright protection claimed includes all
forms and matters of copyrightable materials and information now allowed by
statutory or judicial law or hereinafter granted. Product names used in this
document may be trademarks or registered trademarks of their respective
companies and are hereby acknowledged. All non-ELATION brands and product
names are trademarks or registered trademarks of their respective companies.
MAGMATIC EFFECTS and all affiliated companies hereby disclaim any and all
liabilities for property, equipment, building, and electrical damages,
injuries to any persons, and direct or indirect economic loss associated with
the use or reliance of any information contained within this document, and/or
as a result of the improper, unsafe, insufficient and negligent assembly,
installation, rigging, and operation of this product.
MAGMATIC EFFECTS | 6122 S. Eastern Ave. | Los Angeles, CA. 90040
323-582-3322 |
323-832-9142 fax |
www.elationlighting.com I
sales@magmaticeffects.com
Elation Professional B.V. | Junostraat 2 | 6468 EW Kerkrade, The Netherlands
+31 45 546 85 66 | +31 45 546 85 96 fax |
www.elationlighting.eu |
info@elationlighting.eu
Elation Professional Mexico | AV Santa Ana 30 | Parque Industrial Lerma,
Lerma, Mexico 52000
+52 728-282-7070
DOCUMENT VERSION
Date| Document Version| Software Version >| DMX Channel
Mode| Notes
---|---|---|---|---
03/06/20| 1| 1.0| 1 / 3 / 5| Initial Version
12/01/20| 2| 1.0| 1 / 3 / 5| Update Dimensional Drawings
12/07/20| 3| N/C| No Change| Updated Voltage Specs
GENERAL INFORMATION
INTRODUCTION
Please read and understand the instructions in this manual carefully and thoroughly before attempting to operate this device. These instructions contain important safety and use information. This product is intended to be used by professionally trained personnel only and is not suitable for private use.
UNPACKING
Every device has been thoroughly tested and has been shipped in perfect
operating condition. Carefully check the shipping carton for damage that may
have
occurred during shipping. If the carton is damaged, carefully inspect the
device for damage, and be sure all accessories necessary to install and
operate the device have arrived intact. In the event damage has been found or
parts are missing, please contact our customer support team for further
instructions. Please do not return this device to your dealer without first
contacting customer support. Please do not discard the shipping carton in the
trash. Please recycle whenever possible.
BOX CONTENTS
Locking Power Cable
CUSTOMER SUPPORT
Contact MAGMATIC customer service for any product related service and support
needs.
Also visit forums.elationlighting.com with questions, comments or suggestions.
ELATION SERVICE USA – Monday – Friday 8:00am to 4:30pm PST
323-582-3322 | Fax
323-832-9142 |
sales@magmaticeffects.com
ELATION SERVICE EUROPE – Monday – Friday 08:30 to 17:00 CET
+31 45 546 85 63 | Fax +31 45 546 85 96 |
support@elationlighting.eu
REPLACEMENT PARTS please visit
parts.elationlighting.com
IMPORTANT NOTICE!
THERE ARE NO USER-SERVICEABLE PARTS INSIDE THIS UNIT. DO NOT ATTEMPT ANY
REPAIRS YOURSELF; DOING SO WILL VOID YOUR MANUFACTURER’S WARRANTY. DAMAGES
RESULTING FROM MODIFICATIONS TO THIS FIXTURE AND/OR THE DISREGARD OF SAFETY
INSTRUCTIONS AND GUIDELINES IN THIS MANUAL VOID THE MANUFACTURER’S WARRANTY
AND ARE NOT SUBJECT TO ANY WARRANTY CLAIMS AND/OR REPAIRS.
LIMITED WARRANTY (USA ONLY)
A. Magmatic Effects hereby warrants, to the original purchaser, Magmatic
products to be free of manufacturing defects in material and workmanship for a
period of two years (730 days) from the original date of purchase. This
warranty excludes all product accessories. This warranty shall be valid only
if the product is purchased within the United States of America, including
possessions and territories. It is the owner’s responsibility to establish the
date and place of purchase by acceptable evidence, at the time service is
sought.
B. For warranty service, send the product only to the Magmatic Effects
factory. All shipping charges must be pre-paid. If the requested repairs or
service (including parts replacement) are within the terms of this warranty,
Magmatic Effects will pay return shipping charges only to a designated point
within the United States. If any product is sent, it must be shipped in its
original package and packaging material. No accessories should be shipped with
the product. If any accessories are shipped with the product, Magmatic Effects
shall have no liability what so ever for loss and/or or damage to any such
accessories, nor for the safe return thereof.
C. This warranty is void if the product serial number and/or labels are
altered or removed; if the product is modified in any manner which Magmatic
Effects concludes, after inspection, affects the reliability of the product;
if the product has been repaired or serviced by anyone other than the Magmatic
Effects factory unless prior written authorization was issued to purchaser by
Magmatic Effects; if the product is damaged because not properly maintained as
set forth in the product instructions, guidelines and/ or user manual.
D. This is not a service contract, and this warranty does not include any
maintenance, cleaning or periodic check-up. During the periods as specified
above, Magmatic Effects will replace defective parts at its expense, and will
absorb all expenses for warranty service and repair labor by reason of defects
in material or workmanship. The sole responsibility of Magmatic Effects under
this warranty shall be limited to the repair of the product, or replacement
thereof, including parts, at the sole discretion of Magmatic Effects. All
products covered by this warranty were manufactured after January 1, 1990, and
bare identifying marks to that effect.
E. Magmatic Effects reserves the right to make changes in design and/or
performance improvements upon its products without any obligation to include
these changes in any products theretofore manufactured.
F. No warranty, whether expressed or implied, is given or made with respect to
any accessory supplied with the products described above. Except to the extent
prohibited by applicable law, all implied warranties made by Magmatic Effects
in connection with this product, including warranties of merchantability or
fitness, are limited in duration to the warranty periods set forth above. And
no warranties, whether expressed or implied, including warranties of
merchantability or fitness, shall apply to this product after said periods
have expired. The consumer’s and/or dealer’s sole remedy shall be such repair
or replacement as is expressly provided above; and under no circumstances
shall Magmatic Effects be
liable for any loss and/or damage, direct and/or consequential, arising out of
the use of, and/or the inability to use, this product.
G. This warranty is the only written warranty applicable to Magmatic Effects
products and supersedes all prior warranties and written descriptions of
warranty terms and conditions heretofore published.
WARRANTY RETURNS (USA ONLY)
To obtain warranty service, a Return Materials Authorization (RMA) number must
first be obtained from MAGMATIC. It is the Customer’s responsibility to
provide product proof of purchase and serial number by acceptable evidence
such as an invoice copy or an approved MAGMATIC Extended Warranty Certificate
(“EWC”) and any relevant maintenance records at the time warranty service is
sought. Failure to provide acceptable evidence of product proof of purchase or
EWC and any relevant maintenance records may be cause for denial of warranty
service.
Products returned for warranty service must be sent without any accessories
(i.e., power, data, and safety cables, brackets, clamps, rigging hardware,
frost filters, gel frames, barn doors, lens, hoses, nozzles, rack mounting
hardware, etc.), must be boxed using the original and/or suitable packaging
materials (double-box and foam) that provides ample product protection for
ground and/or air freight transit, and must be shipped freight pre-paid and
insured to MAGMATIC in Los Angeles, CA or an MAGMATIC Authorized Service
Center. The RMA number must be clearly written on the outside of the return
box, and a brief description of the problem and the RMA number must be
documented
and included in the box.
Products returned for warranty service without an RMA number clearly marked on
the outside of the package will be refused and returned to the shipper at the
Customer’s expense. Products returned for warranty service, which are received
damaged due to inadequate and/or improper packaging and/or due to damage
caused by shipping carrier, may incur additional repair charges before
warranty service begins and/or may void this warranty. If any product
accessories (included and/or optional) are shipped with the product, MAGMATIC
and/or the MAGMATIC Authorized Service Center shall have no liability what so
ever for the loss and/or damage to any such accessories, nor the safe return
thereof. If the requested warranty repairs or service (including parts
replacement) are within the terms of this warranty, MAGMATIC will pay return
ground transportation shipping charges to a single designated point within the
United States.
SAFETY GUIDELINES
To guarantee a smooth operation, it is important to follow all instructions
and guidelines in this manual.
MAGMATIC is not responsible for injury and/or damages resulting from the
misuse of these devices due to the disregard of the information printed in
this manual. Only qualified and/or certified personnel should perform
installation of these devices and only the original rigging parts included
with these devices should be used for installation. Any modifications to these
devices and/or the included mounting hardware will void the original
manufactures warranty and increase the risk of damage and/or personal injury.
PROTECTION CLASS 1 – DEVICES MUST BE PROPERLY GROUNDED
THERE ARE NO USER-SERVICEABLE PARTS INSIDE THESE DEVICES.
DO NOT ATTEMPT ANY REPAIRS YOURSELF; DOING SO WILL VOID YOUR MANUFACTURES
WARRANTY. DAMAGES RESULTING FROM MODIFICATIONS TO THESE DEVICES AND/ OR THE
DISREGARD OF SAFETY INSTRUCTIONS AND GUIDELINES IN THIS
MANUAL VOID THE MANUFACTURES WARRANTY AND ARE NOT SUBJECT TO ANY WARRANTY
CLAIMS AND/OR REPAIRS.
DO NOT PLUG THIS UNIT INTO A DIMMER PACK! DO NOT REMOVE THE COVER UNDER ANY
CONDITIONS! KEEP UNIT UPRIGHT!
NEVER OPERATE THIS UNIT WITH THE COVER REMOVED! UNPLUG POWER DURING LONG
PERIODS OF NON-USE
ENSURE TANK AND COOLER ARE EMPTY BEFORE STORAGE OR TRANSPORT! DO NOT MOVE THE
UNIT WHEN FILLED WITH WATER AND ICE! DISCONNECT POWER BEFORE ADDING WATER OR
PERFORMING MAINTENANCE!
INDOOR / DRY LOCATIONS USE ONLY!
DO NOT EXPOSE DEVICES TO RAIN AND/OR MOISTURE! PLACE UNIT IN A WELL-VENTILATED
AREA. ALLOW 40” (100CM) ABOVE AND AROUND THE UNIT FOR PROPER VENTILATION
SAFETY GUIDELINES
DO NOT attempt installation and/or operation of devices without knowledge how
to do so.
DO NOT point or direct the fog in an unsafe direction.
DO NOT touch the front nozzle when the machine is operating or has just been
shut down. The nozzlecan reach high temperatures.
DO NOT permit operation by persons who are not qualified to operate these
types of devices.
DO NOT shake devices, avoid brute force when installing and/or operating.
DO NOT operate device if the main power cord has become frayed, crimped and/or
damaged. Replace
any damaged power cords with a similar power rating.
DO NOT remove or break-off the ground plug from the device power cords.
DO NOT remove or disassemble devices, there are NO user serviceable parts
inside.
ALWAYS disconnect devices from main power source before cleaning.
ALWAYS disconnect unit from main power before adding or draining water.
ALWAYS drain the fluid before moving device.
ALWAYS be sure to keep the device on a level surface.
ALWAYS be sure to use this device in an area that will allow proper
ventilation.
ALWAYS disconnect power cords during long periods of non-use.
CAUTION Fog and haze machines may set off smoke alarms.
Power cords should be safely routed and secured so they are not likely
pinched.
Use the original packaging and materials to transport this device in for
service.
These devices should be serviced by qualified service personnel when:
- The power cords or plugs have become damaged.
- Objects have fallen on and/or liquid has spilled into the devices.
- The devices have been exposed to rain and/or moisture.
- The devices do not operate normally or exhibit a marked change in performance.
OVERVIEW
1. Output Nozzle | 8. Breaker |
---|---|
2. Fan | 9. Locking Power Cable Input |
3. Carrying Handle | 10. Locking 5-Pin XLR Connector In |
4. Fluid Reservoir Cap | 11. Locking 5-Pin XLR Connector Out |
5. Fluid Level | 12. Remote Control Connection |
6. Touch Screen Display | 13. E-Fly & App-WiFi Card Inputs |
7. Power Switch
SET UP
-
Open the shipping carton and carefully remove the unit and all included items from the shipping carton.
-
Be sure to remove all the packing material especially around the nozzle.
-
Set the machine on a flat dry surface. Remove the fluid reservoir cap and carefully fill the fog fluid reservoir with Atmosity Extreme Filtered water based smoke & haze fluid. Once the fluid tank is filled, replace and tighten the reservoir cap.
-
Connect the unit to a matching power supply and put the power switch into the “ON” position.
Once power is applied, the fan will begin to operate and the machine will begin to heat up.
When the machine is heating up, the display will read “HEATING” in the top left corner with the heating percentage. -
The machine takes 6 minutes to heat up. When the machine has reached its operating temperature the display will read “READY”.
-
To emit haze, select your desired operating mode using the touch screen display. See the control panel and system menu on pages 10-12.
CONTROL PANEL
This fixture includes a system menu with an easy to navigate touch screen
control panel where all necessary settings and adjustments are made. When
first powering on the fixture, the fixture’s main menu will be displayed (see
Main Menu Screen below).
Press the main menu icon you would like to access. Use the ENTER button to
access sub menus and use the UP and DOWN buttons to make adjustments. Press
the ENTER button to confirm your adjustments. You may exit the main menu at
any time without making any adjustments by pressing the BACK/EXIT button.
TIMER MENU: The timer sub menu includes fog output adjustment, fan
adjustment, duration adjustment, and interval adjustment. To access the TIMER
adjustment menu, press the SETTINGS icon located at the bottom of the screen.
Use the UP and DOWN buttons to make your adjustments and press ENTER to
confirm. When all settings have been made, press the PLAY/START button to
begin timer fogging.
SYSTEM MENU
MENU | SUBMENU | OPTIONS | DESCRIPTION |
---|---|---|---|
1. DMX Addr | 001-50(X | DMX Addressing | |
2. DMX Mode | 1 / 3 / 5 | DMX Channel Mode | |
1. WIFI SET”‘ | WiFi Name | 0-X.ta | Displays the |
WiFi Name
‘A/Pi Passcode| 00000000-00009999| WiFi Password
WiFi IP| 0-255.0-255.0-255.0-255| WiFi P is Displayed
WiFi Port| 0455535| Network Port
Reset Network| Caudate / FaikA, try aoain| Network Connection
Ftese
win-Amx & Efty| ON / OFF| DM or EFLY Tranwnition
2. LCD Set| Screen OFF:
Neyet/Ills/40s/lmin/5min/lOmin/20min| Display Blackout Tim
3. EFLY Set w| ER.? Channel: 0-14| EFLY Channel
Setting
EFLY: ON / OFF| EFLY Activation
4. No Fluid| ON / OFF| Actiyate/Deaaivate No
Fluid Warning
5.1IF Learn”| |
6. Last State| YES / NO| Activate/Deactivate Last State
7. Default| YES / NO| Restore Factory Settings
| –| 1%-100%| Manual Coot o’
| 20%-100%
| Preset 1:| Preset Settings I (Not Adjustable)
Preset 2:| Preset Settings 2 (Not Adjustable)
Preset 3:| Preset Settings 3 (Not Adjustable)
Preset 4:| Preset Settings 4 (Not Aclustable)
Preset 5:| Preset Settings 5 Not Aclustable)
SYSTEM MENU
MENU | SUBMENU | OPTIONS/DISPLAY | DESCRIPTION |
---|---|---|---|
1. State | Normal / Error | Machine Status | |
2. Slot 1 | Null / EFLY / WIFI / RF | Slot 1 Status | |
3. Slot 2 | Null / EFLY / WIFI / RF | Slot 2 Status | |
4. Last Control | LCD_auto / LCD_manual / DMX / WIFI / RF / Remote / Error |
Current Control Status
5. Remote State| YES / NO| Remote Control Status
6. WIFI Connect| Null / Phone / Route / No| WIFI Connection Status
7. WIFI IP| No / 0-255, 0~255, 0~255, 0~255| Current WIFI IP Status
8. E-FLY CH.| XX| Current E-FLY Channel Setting
9. DMX Addr.| XXX| Current DMX Address Setting
10. DMX Mode| X| Current DMX Ch. Mode Setting
11. Timer Output| XXX%| Current Timer Output Setting
12. Timer FanSp| XXX%| Current Timer Fan Setting
13. Timer Int.| XXXXs| Current Timer Interval Setting
14. Timer Dur.| XXXs| Current Timer Duration Setting
15. Heat Proc.| XXX%| Heating Progress Status
16. No Fluid| Normal / Empty| Current Fluid Tank Status
17. Heater State| Normal / Error / No Heat| Heater Status
18. LCD Ver.| VX.X| Current LCD Version
19. Sftwr Ver.| VX.X| Current Software Version
| FOG OUTPUT| 1%-100%| Fog Output Setting
FAN SPEED| 20%-100%| Fan Speed Setting
INTERVAL| 0-2500s| Interval Setting
DURATION| 0-250s| Duration Setting
NOTES:
-
WIFI SET – When there is no card connected, selecting “WIFI SET” will display the following:
“Optional Module Not Installed”. -
EFLY SET – When there is no card connected, selecting “EFLY SET” will display the following:
“Optional Module Not Installed”. -
RF LEARN – When there is no card connected, selecting “RF LEARN” will display the following:
“Optional Module Not Installed”.
DMX CHANNEL FUNCTIONS & VALUES
1 CH | 3 CH | 5 CH | VALUES | FUNCTIONS |
---|---|---|---|---|
1 | 1 | 000-005 | ||
006-255 | FOG OUTPUT |
OFF
ON
1| 2| 2| 000-255| OUTPUT VOLUME
0% – 100%
| 3| 3| 000-255| FAN
20% – 100%
| | 4| 000-005
006-255| OUTPUT DURATION
NO DURATION
1S – 250S
| | 5| 000-005
006-255| INTERVAL
NO INTERVAL
10S – 2500S
DIMENSIONAL DRAWINGS
TROUBLESHOOTING
If you experience low output, pump noise, or no fog output at all, disconnect and discontinue use immediately. Do not attempt to continue to operate as this may damage the machine. Check the fluid level, the breaker, and be sure the wall outlet is sending power. If all of the above appears to be okay, and the unit fails to operate correctly, the unit will require service. Please contact Magmatic Effects.
CLEANING & MAINTENANCE
When storing your fog machine be sure to store it in a cool area. Cover the machine so that dust does not build up on the unit. When storing the machine for long periods of time, it is highly advised to at least run the machine every 3-4 months. Long periods of inactivity can severly shorten the life of your machine. Only run Atmosity Extreme Filtered Fog Fluid (AEF-4L) through your machine. Never run plain water, vinegar, or any other liquid solution through your machine. Running anything other then water based fog juice will severly damage your machine.
SPECIFICATIONS
PERFORMANCE:
Rated Power: 700W
Max Output: 4,000 CFM (cu ft/min.) (113 m3/min)
Ready Time: Intial = 6 Minutes*
Fluid Capacity: 0.345 Gallons (1.3 Liters)
Fluid Consumption: 0.115 oz/min (3.4 ml/min)
COMPATIBLE FLUID:
Atmos Extreme Filtered Fog Fluid (AEF-4L)
CONSTRUCTION:
Thermally Protected Heat Exchanger
Advanced HPA (High Pressure Air) Pump Technology
Energy Saving Mode with Auto-Clean Process Sealed Fluid Resrvoir
External Visual Fluid Level Detection
Compact Light Weight Mobile Design
CONTROL:
3 DMX Channel Modes: (1/3/5)
Onboard LCD Touch Control Panel
DMX-512 and RDM Protocol Support
Optional MAGFLY Wireless DMX Transceiver
Optional MAGRF Wireless Wired Remotes| SIZE / WEIGHT:
Length: 13.3in (338mm)
Width: 6.30in (160mm)
Height: 15.70in (400mm)
Weight: 22.48 lbs. (10.2kg)
---|---
CONNECTIONS:
Locking 5Pin XLR Connector In/Out
IP65 Locking Power Connector In
With Wired Digital Communication Network| ELECTRICAL:
AC120V 60Hz (US Version)
AC230V 50Hz (EU Version)
Breaker: 9A @ 120VAC (NFB)
Breaker: 5A @ 230VAC – 240VAC (NFB)
THERMAL:
Max. Ambient Temperature (Ta max) 104°F (40°C)
Exterior Surface Temperature, Steady State: 122°F (50°C)
OPTIONAL ACCESSORIES:
MagFly
MagRF
APPROVALS / RATINGS:
CE | cETLus | IP20
FCC STAT E M E N T
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
FCC RADIO FREQUENCY INTERFERENCE WARNINGS & INSTRUCTIONS
This equipment has been tested and found to comply with the limits for a class
B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This device uses and can radiate radio frequency
energy and, if not installed and used in ccordance with the included
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this device does cause harmful interference to radio or
television reception, which can be determined by turning the device off and
on, the user is encouraged to try to correct the interference by one or more
of the following methods:
- Reorient or relocate the device.
- Increase the separation between the device and the receiver.
- Connect the device to an electrical outlet on a circuit different from which the radio receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Please note that the changes or modifications of this product is not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.