ELRO FS4610 Ultra Thin Smoke Detector With 10 Year Battery Instruction Manual
- June 5, 2024
- ELRO
Table of Contents
ELRO FS4610 Ultra Thin Smoke Detector With 10 Year Battery
INTENDED USE: FIRE SAFETY
ESSENTIAL CHARACTERISTICS: PASSED
Response delay (response me) and Performance under fire conditions Tolerance to
supply voltage reliability and response delay, temperature resistance,
vibration on resistance, humidity resistance, corrosion resistance, electrical
stability
OVERVIEW
- CONTENT
- ACTIVATE
- TESTING
- ROOMS
- CEILING
- TEST &CLEAN
- ALARM SILENCE
This smoke alarm is equipped with a self-test mechanism. At least once a month at a random moment, the device automatically checks the functionality of the sensor and the siren. During a successful test, the detector will beep and blink briefly. If problems are detected, the detector switches to error mode. Replace the device immediately if the error message occurs.
Operating mode
| Visual signal (flash)| Acoustic signal (beep)| Description
mode
---|---|---|---
Normal| 1 x per 40 second| None| Device is functioning properly
Self test| 1 x| 1 x| Device functions correctly
Manual test| 3 x| 3 x| Device functions correctly
Alarm| 1 x per second (3 x) / pause of 1,5 seconds| 1 x per seconds (3 x) /
pause of 1,5 seconds| Device is detecting smoke
Alarm silence| 1 x per 8 seconds| None| The smoke alarm signal is muted
Low ba ery warning| 1 x per 40 seconds| 1 x per 40 seconds| The baTTERy is
running low
Low ba ery warning silence| None| None| The low battery warning is muted
Sensor fault warning| 1 x per 40 seconds| 1 x per 40 seconds| The sensor is
not functioning properly
Buzzer fault warning| 2 x per 40 seconds| None| The buzzer is not functioning
properly
Symbols
- Recycling and disposal: The WEEE symbol means that this product and batteries must be disposed of separately from other household waste. When it reaches its end of life, take it to a designated waste collection on point in your area to guarantee safe disposal or recycling. Protect the environment human health and natural resources!
- Read the manual before use and store it in a safe place for future use and maintenance. Download Declara on of Performance (DoP) at www.elro.eu
Warnings:
- To prevent injury, this apparatus must be securely attached to the ceiling in accordance with the installed on instructions.
- Batteries shall not be exposed to excessive heat such as sunshine and fire.
- Batteries life me shortens without monthly test.
- Keep away from air conditoning/ven la on.
- Do not paint or cover the device.
- Consult local regulations.
- Troubleshoot: False alarm is often caused by dust or steam. In case of doubt: Leave the building and take ac on! Additional mounting instructions:
- Corridor max width 3m: Max 15m between 2 alarms. Max. 7,5m to front side and alarms at edges/crossings of corridors.
- Galleries: Length and width >2m and >16m², additional alarms below gallery. Par al roof slopes: Flat ceiling ≤1m wide, consider as the roof slope. Flat ceiling >1m wide, consider as flat ceiling.
Instruction