dreame V10 Cordless Vacuum Cleaner User Manual
- June 5, 2024
- dreame
Table of Contents
dreame V10 Cordless Vacuum Cleaner
Product Overview
Part Names
Product Overview
Accessories
Installation
Vacuum and Accessories Installation Diagram
Installing the 2-in-1 Charging & Storage Mount
- The 2-in-1 charging & storage mount is an optional accessory, you can install it based on your requirements.
- The mount should be installed in a cool, dry place near a power outlet, out of direct sunlight, and away from moisture-prone areas, such as a kitchen.
- Securely install the mount using mounting hardware suitable for the type of wall selected. Make sure the installation area is clear of any pipes such as gas or water lines, and air ducts, electric wires and cables, or drainage lines.
- It is recommended to hire a professional to install the mount and to use protective clothing, goggles, and other protective equipment where necessary.
- Using an electric drill, mark and drill two 8 mm diameter holes into the wall where desired to a depth of about 30 mm. Insert the wall plugs into the holes, position the mount, then fasten it to the wall with the included screws.
How to Use
Note:
- Fully charge the vacuum before using it for the first time. This will take about 4 hours.
- Vacuum cannot be used while charging.
- Vacuuming at turbo mode for a prolonged period will cause the battery to heat up, which increases charging time. Allow the vacuum to cool down for 30 minutes before charging it.
Using Different Attachments
- Mini-Motorized Nozzle: Strong vibrations yield deep cleaning action for removing mites and dust from mattresses and fabric surfaces.
- 2-in-1 Crevice Nozzle: Suitable for vacuuming cracks, corners of doors and windows, stairs, and other hard-to-reach places.
- 2-in-1 Brush Nozzle: Suitable for vacuuming up dust and mites on beds, sofas, and other furniture fabric.
- Soft Roller Nozzle: Suitable for vacuuming the hard surfaces such as floor, tile, marble, as well as for vacuuming up larger pieces of dirt and debris. The Soft Roller Nozzle can also be directly attached to the vacuum.
Care & Maintenance
Tips:
- Always use genuine parts to keep your warranty from being voided.
- If the filter or nozzle becomes clogged, the vacuum will stop working shortly after being turned on. To restore functionality, clean the filter or nozzle.
- If the vacuum will not be used for an extended period, fully charge it, unplug its power adapter, and store it in a cool, low-humidity environment away from direct sunlight. To avoid over-discharging the battery, recharge the vacuum at least once every 3 months.
Cleaning the Vacuum
Wipe the vacuum with a soft dry cloth.
Cleaning the Dust Compartment
Before cleaning the dust compartment, disconnect the adapter and keep the
vacuum’s power switch in the off position. The vacuum’s cleaning ability will
be reduced if the dust compartment is filled to the “MAX” mark. To regain
performance, empty the compartment. To empty the dust compartment: Press the
release button on the bottom of the compartment, then empty its
contents.
Cleaning the Cyclone Assembly
- Rotate the cyclone assembly in the direction illustrated to unlock it, then remove the cyclone assembly.
- Rinse the cyclone assembly with water until it is clean. To thoroughly dry the cyclone assembly, keep it in a ventilated or cool place for at least 24 hours. Caution: Do not clean the cyclone assembly in a dishwasher or washing machine, and do not attempt to dry it in a tumble dryer, oven, microwave, or near an open fire.
- Once it is dry, reinstall the cyclone assembly.
Cleaning the HEPA Filter Assembly
-
Place the vacuum securely on a flat surface, then turn the HEPA filter assembly cover in the direction indicated and remove the HEPA filter assembly.
Note: Remove the built-in foam pad before cleaning the HEPA filter assembly. Rinse the HEPA filter and foam pad with water. -
Rinse the HEPA filter and foam pad with water. To thoroughly remove all dust caught in the filter, rotate the HEPA filter by 360 degrees while rinsing. Lightly tap the filter against a sink several times to remove any excess debris.Keep the HEPA filter in a well-ventilated and cool place to fully dry.
Note: Fully dry the filter (at least 24 hours) before reinstalling it.
Cleaning the Soft Roller Nozzle and Mini-Motorized Nozzle
Note: To prevent injury from accidentally turning on the vacuum, make sure the
Soft Roller Nozzle or Mini-Motorized Nozzle is detached from the vacuum before
removing the head. The Mini-Motorized Nozzle and Soft Roller Nozzle contain
electrical components, and the Soft Roller Nozzle head also contains bearings.
Do not wash these parts with water. Be careful of sharp objects when removing
debris caught in the heads of Soft Roller Nozzle and
Mini-Motorized Nozzle.
Cleaning the Soft Roller Nozzle
- Push the brushbar head release button in the direction of the arrow until the cover of the brushbar head pops to open, then remove the brushbar head by lifting it in the direction indicated.
- After you have finished cleaning the Soft Roller Nozzle , reinstall it by following the disassembly steps in reverse.
Cleaning the Mini-Motorized Nozzle
- Use a coin as illustrated to rotate the lock counterclockwise until you hear a click.
- After unlocking the brush head, remove it from the Mini-Motorized Nozzle , then rinse and clean the brush head.
- Stand the brush head upright in a well-ventilated area for at least 24 hours until it is fully dry.
- Once the Mini-Motorized Nozzle is dry, reinstall it by following the disassembly steps in reverse.
Troubleshooting
Errors | Possible Causes | Solutions |
---|
Vacuum does not work
| Vacuum is out of battery or low on power.| Fully charge the vacuum, then
resume use.
Overheat protection mode triggered by a blockage.| Wait until the vacuum cools
down, then reactivate it.
Suction opening or airway passage is blocked.| Clear any blockages from
suction opening or airway passage.
Weak suction force
| Dust compartment is full and/or HEPA filter assembly is clogged.| Empty the
dust compartment and clean the HEPA filter assembly.
Attachment is blocked.| Clear any blockages in the attachment.
Motor makes a strange noise| Main suction opening or extension rod is
blocked.| Clear any blockages in main suction opening or extension rod.
The first indicator is red after turning on the vacuum| Battery is damaged.|
Please contact the after-sales service department for maintenance.
The first indicator blinks red after turning on the vacuum.|
Power adapter is incompatible.
| Only use the original power adapter to charge the vacuum.
Battery indicator does not light up while charging
| The adapter is not connected to the vacuum.| Make sure the power adapter is
plugged in properly.
The battery is fully charged and went into sleep mode.| Can be used normally.
If the problem persists after ruling out the above two possibilities.| Please
contact the after-sales service department for maintenance.
Charges slowly| Battery temperature is too low or too high.| Wait until the
battery’s temperature normalizes, then resume use.
If the vacuum is not working properly, please refer to the troubleshooting table below.\
WEEE Information
All products bearing this symbol are waste electrical and electronic equipment (WEEE as in directive 2012/19/EU) which should not be mixed with unsorted household waste. Instead, you should protect human health and the environment by handing over your waste equipment to a designated collection point for the recycling of waste electrical and electronic equipment, appointed by the government or local authorities. Correct disposal and recycling will help prevent potential negative consequences to the environment and human health. Please contact the installer or local authorities for more information about the location as well as terms and conditions of such collection points.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>