THERMASOL Total Wellness Package with 10 Inch ThermaTouch Round Instruction Manual

June 9, 2024
THERMASOL

Total Wellness Package with 10 Inch ThermaTouch Round

Total Wellness ThermaTouch 10 Package

Installation Manual
For Tutorials and Troubleshooting visit www.thermasol.com/solutions
*Products available in square styling not shown
OVER 60 YEARS OF STEAM SHOWER INNOVATION

ThermaTouch Control

Installation Manual
For Tutorials and Troubleshooting visit www.thermasol.com/solutions TT10-XX
OVER 60 YEARS OF STEAM SHOWER INNOVATION

ThermaTouch Control Installation Instructions
1 Important Information before You Install
The ThermaTouch Control must be installed inside the shower. The ThermaTouch control will only function on the current TFX, SSA and PRO Series generators.
The control should be installed 60″ from the floor of the shower and away from the steamhead.
The steamhead should be installed 24″ from the floor and 6″ from any wall. Locate as far as possible from the bathing seating area or location of the users and not below any fixtures.
IMPORTANT: When locating and installing the ThermaTouch, it is required to not place the control under any water-outlets, shower heads or in the direct path of flowing water. SEE DIAGRAM FOR LOCATION EXAMPLE.

PLEASE REVIEW WARNINGS BELOW AND LEAVE THIS MANUAL WITH HOMEOWNER
DO NOT USE THIS PRODUCT UNLESS YOU HAVE CONSULTED WITH YOUR DOCTOR AND RECEIVED WRITTEN PERMISSION TO DO SO. USE OF THIS PRODUCT MAY BE HAZARDOUS TO YOUR HEALTH.
PLEASE CONSULT YOUR PHYSICIAN BEFORE USING. IF YOU ARE PREGNANT, ELDERLY, HAVE HIGH BLOOD PRESSURE, DIABETES, SUFFERING FROM HEART DISEASE, ARE INTOXICATED, OR NOT IN GOOD HEALTH, DO NOT USE THIS STEAM BATH.
STEAM IS HOT! DO NOT TOUCH OR GO NEAR THE STEAMHEAD FROM THE TIME THE UNIT IS “ON,” UP TO ONE HOUR AFTER IT HAS SHUT OFF. SEVERE BURNS WILL OCCUR IF YOU COME IN CONTACT WITH THE STEAMHEAD OR STEAM EMITTING FROM THE STEAMHEAD.
NEVER ATTEMPT TO FILL AROMA RESERVOIR ON THE STEAMHEAD WHEN UNIT IS IN THE “ON” POSITION. SEVERE BURNS WILL OCCUR.
DO NOT USE THERMASOL AROMATHERAPY OILS, SKIN CARE PRODUCTS OR ANY PRODUCT ASSOCIATED WITH YOUR THERMASOL UNIT WITHOUT CONSULTING WITH YOUR ALLERGIST OR DOCTOR BEFORE USE. THESE PRODUCTS MAY BE HAZARDOUS TO YOUR HEALTH.
DO NOT USE STEAM ROOM WHILE UNDER THE INFLUENCE OF ALCOHOL OR DRUGS, AS THIS CAN BE HAZARDOUS TO YOUR HEALTH.
YOUR SHOWER MAY BE A SLIP-AND-FALL HAZARD. CHECK WITH YOUR CONTRACTOR OR FLOORING MANUFACTURER REGARDING THE SAFE USE OF YOUR FLOORING IN A STEAM APPLICATION. SLIPPING AND FALLING INTO THE STEAMHEAD ITSELF OR INTO THE STREAM OF STEAM EMITTING FROM THE STEAMHEAD WILL CAUSE SERIOUS BURNS OR PHYSICAL INJURY.
IF YOU ARE FEELING UNCOMFORTABLE, DIZZY, FAINT, OR STARTING TO FALL ASLEEP, IMMEDIATELY EXIT THE STEAM ROOM.
DO NOT USE STEAM ROOM IF YOU ARE UNDER THE AGE OF 16 UNLESS SUPERVISED BY AN ADULT.
THERMASOL STEAM BATH GENERATORS ARE NOT DESIGNED TO BE USED FOR SPACE HEATING PURPOSES.
THERMASOL STEAM BATH GENERATORS ARE FOR INDOOR USE ONLY. THEY SHOULD NEVER BE LOCATED OUTSIDE THE HOME.
All products must be installed in accordance with installation instructions provided. Failure to do so may invalidate warranty at manufacturer’s discretion. ©2019ThermaSol.

Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details.

2

THERMASOL.COM I 800.776.0711

1a Important Installation step
YOUR THERMATOUCH SMART TOUCHSCREEN CONTROL COMES WITH A PREINSTALLED EARTH GROUNDING WIRE ON THE BACK OF THE CONTROLLER. PRIOR TO INSTALLTION OF YOUR THERMATOUCH LOCATE THE CLOSEST EARTH
GROUND (COPPER WATER PIPE) AND ATTACHED THE WIRE AS SHOWN BELOW. IF YOU HAVE ANY QUESITONS ABOUT THIS PROCESS PLEASE CONTACT US AT [email protected] OR BY
PHONE AT 800.776.0711

EARTH GROUNDING WIRE

GROUNDING STRAP
COPPER WATER PIPE

THERMASOL.COM – 1.800.776.0711
3

ThermaTouch Control Installation Instructions
2 Tools and Materials

Controller Item TT10-XX

Silicone

25-foot Yellow M12 Cable
Item 03-7149-25

Power Supply Brick Item 03-7142

PDM Item 10-8147

RCA cable 25 foot
Item 03-7207

Mud Ring Item 04-8567

Installation instructions, warranty, static cling warning label

Materials needed: ThermaTouch control M12 cable Silicone Power Distribution Module (PDM) Mud Ring Ethernet Cable with RJ-45 Connector (not supplied) Other materials as required

Back of Control

Bluetooth Antenna

Power/Data M12 connection
Plug in network cable RJ-45 for updates over the internet
Audio Out

Earth Ground Wire
REMINDER in order to receive software updates the unit must be plugged into
the internet using an Ethernet Cable connected to a Router (Router and Ethernet Cable not supplied).

3 Mud Ring Application

Shower wall

Shower wall

Finished wall must be flush with the mud ring.

Mud Ring goes inside wall opening

9.75″W x 6.375″H x 3.125″D opening for recessed mount TT10-XX Mud Ring

Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details.

THERMASOL.COM I 800.776.0711

4

ThermaTouch Control Installation Instructions

4 Control Installation and Data Cable Connection

Shower wall

Ethernet cable with RJ-45 (not included)
RCA cable included with control Earth Ground Wire

Route the M12 cable through the finished wall to the back side of the control. (The other end of the cable runs to the PDM location.) NOTE: It is recommended to run the cable through electrical conduit. DO NOT STAPLE the cable!
Run the M12 cable so the 90-degree end connection will connect to the ThermaTouch control. Then connect the M12 Cable to ThermaTouch control. Do not over tighten.

M12 Cable

If the Light, Sound, Rain Head option is not used then amplified speakers are required for
sound.

Connector Detail

“ON” Turn Clockwise

Contact pins

“OFF” Turn Counter Clockwise

Contact pins

Cable ends

DO NOT pinch, nail, staple, wedge, or bind the data cable.
DO NOT wrap the data cable around steam line or route it in a manner so that the hot steam line could melt the cable.
Any damage to the control cable will result in the control not working properly.
Carefully connect the data cable to the PDM and control BEFORE turning power on to the generator or PDM.

· Do not staple, strain or damage data cable · Align pins to receptacle visually before tightening · Do not force plug · Hand tighten only

TTC SLS
Connect to PDM PDM requires 110V power

Connect the data cable to Power Distribution Module (PDM). (The other end of the cable runs to the back of the control in the shower location.)

Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details.

5

THERMASOL.COM I 800.776.0711

ThermaTouch Control Installation Instructions
5 Sealing Control
THESE STEPS MUST BE TAKEN FOR CORRECT INSTALLATION OF THE CONTROL. REMOVE MUD RING FROM WALL CUTOUT BEFORE MAKING FINAL CABLE CONNECTIONS TO THE THERMATOUCH CONTROL. TEST THAT ALL CONNECTIONS ARE WORKING BEFORE SEALING THE CONTROL TO THE WALL. (Power on the control and see that it lights up).
A Coat the entire groove on the control back with supplied waterproof silicone to fully seal the control to the wall. Completely seal the control to the wall so moisture does not collect behind it. Place the control on the wall pressing firmly. (You may need to tape the control into place until the silicone dries.) Be careful not to harm the wall or control with the tape. Let dry for 24 hours before using steam bath.

SILICONE

Wall
Bluetooth Antenna
Earth Ground Wire
Back Side of Surface Mount Control

A

Wall

M12 Cable Connection

Ethernet Cable Connection Audio Cable Connection
Wall
Side View of Surface Mount Control

Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details.

THERMASOL.COM I 800.776.0711

6

ThermaTouch Control Installation Instructions
6a Connecting ThermaTouch to Generator
110v

M8 Cable

TTC SLS
M12 Cable

6b Connecting ThermaTouch to Serenity Light,
Sound, Rainhead

110v

M12 Cable

TTC SLS

Audio Cable

M12 Cable

Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details.

7

THERMASOL.COM I 800.776.0711

ThermaTouch Control Installation Instructions
6c Connecting ThermaTouch to Digital Shower

110v

M12 Cable

TTC SLS

Audio Cable

M12 Cable
6b Connecting Total Wellness Package

110v

M12 Cable

M8 Cable

TTC SLS

Audio Cable

M12 Cable

Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details.

THERMASOL.COM I 800.776.0711

8

ThermaTouch Control Installation Instructions

7 Steam Line and Steamhead

Now you will need to decide on the steamhead placement in the shower so you can run the steam line from the generator to the steamhead. There are a couple of things you need to know about the placement of the steamhead and steam line itself.

DO NOT install any valve in the steam line. Flow of steam must be unobstructed.

DO NOT plumb any traps in the steam line.

A The steam outlet on the generator requires a 1/2″ brass union for easy installation (not included).

B

Use 1/2″ brass pipe or copper tubing from unit to steamhead rough-in fitting as permitted by code.

The steam line can run up and then down, once; or horizontal; but never run down and then up. If it does, a steam trap will be produced at the low point blocking the flow of steam.
Insulate the steam outlet piping if the piping run exceeds 10 feet or is exposed to cold areas. Use steam rated insulation.
Pitch/angle steam lines back towards generator before any up or down turns; pitch/angle towards steam room after any up or down and avoid perfectly level plumbed lines.

A
Shown installed in attic
B

6″ C
24″

Steam Line

Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details.

9

THERMASOL.COM I 800.776.0711

ThermaTouch Control Installation Instructions

Steamhead Location
DO NOT install the steamhead near the seating area or the user.
DO NOT forget to install the steamhead rough-in fitting!
C Install the steamhead 24″ from the floor or bathtub rim and 6″ from any corner.
Steamhead is to be mounted as far as possible from typical bathing position (seated or standing) and installed as far from the in-shower controller as possible.
For retrofit to existing finish wall: Drill a 1-1/8″ diameter hole in the shower wall or wall above bathtub rim for the steam outlet rough-in fitting and install to be flush with the finished wall. this housing must be sealed to the wall to not allow vapor or water behind it. (plumbing must be done from backside of finshed space)
For new framing: Mount and install rough-in fitting to be flush with finished wall.
Connect a 1/2″ NPT brass pipe or copper tubing to the steam outlet union (not included) on the generator running the pipe to the steam head location in the wall to connect with the steamhead rough-in fitting. It is very

important that the pipe is firmly secured to the wall, so that when the steamhead is installed it doesn’t push the rough-in fitting back into the wall. Install a 1/2″ dropear elbow on the end of the 1/2″ pipe or tubing for the rough-in fitting.
Use the installation tool to tighten the housing in place with a 1″ socket and driver. Then insert the protective cap into the housing.
For all the connections, use solder for copper joints and Teflon tape for pipe fittings and do not over tighten fittings. DO NOT USE PVC CEMENT.

C
Insert installation tool and
tighten housing into place
with a 1″ socket and driver

Insert protective cap into housing

Steamhead rough-in fitting to be installed flush and sealed to finished wall

Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details.

THERMASOL.COM I 800.776.0711

10

ThermaTouch Control Installation Instructions

D Once the shower wall is complete and the housing is sealed to the wall, remove the protective cap and insert the steamhead into housing. Use the supplied silicone to adherethe steamhead to the wall sealing out any water from getting behind the head.

Use supplied o-ring lubricant to assist in steam head installation. A very small amount is all that is need directly on the o-rings.

D
Remove protective cap from housing

Insert steamhead into housing

Use the supplied silicone to adhere the steamhead to the wall

Apply a small amount of supplied lubricant directly on the o-rings.

Allow 24 hours for silicone to dry before use.

Upon final installation mount steamhead with facing up to allow aromatherapy well to dispense steam. For detailed installation instructions of the steamhead please see Installation section in thermasol.com/customer-support
8 Final Pre-Check Before Operation
Turn ON the water supply to the generator. Check all the connections for leaks. Plug in generator (unless hardwired model). Turn ON the power source or breaker. Verify control panel lights up and test operation. Note: Initial power-on phase takes several minutes for generator to heat up steam. Please direct the home owner to visit www.thermasol.com/solution and click on the “I’m the home owner” button to learn about set-up and programing (in order to set up the clock and any other options if applicable).

Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details.

11

THERMASOL.COM I 800.776.0711

ThermaTouch Control Installation Instructions
9 Trouble Shooting, Tutorials and Error Codes
Visit www.thermasol.com/solutions. Click on Troubleshoot then click on ThermaTouch Control Error Codes.

Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details.

THERMASOL.COM I 800.776.0711

12

1958 STEAM WAY ROUND ROCK, TX 78665 PHONE: 800.776.0711 | FAX: 800.556.5257 | WWW.THERMASOL.COM

81227_A

Digital Shower Valve

Installation Manual
TDS-3000
OVER 60 YEARS OF STEAM SHOWER INNOVATION

Digital Shower Valve
1 Important Information Before You Install
Make sure the walls, ceiling and floor materials are suitable for use with this product. Ensure electrical power is turned off for the duration of the installation. IMPORTANT: The Digital Shower Valve must be accessible and should not be sealed in the wall PLEASE REVIEW WARNINGS BELOW AND LEAVE THIS MANUAL WITH HOMEOWNER BEFORE USING THE SHOWER, TEST THE WATER TEMPERATURE WITH YOUR HAND BEFORE FULLY ENTERING THE SHOWER. DO NOT USE THERMASOL AROMATHERAPY OILS OR SKIN CARE PRODUCTS OR ANY PRODUCT ASSOCIATED WITH YOUR THERMASOL PRODUCT WITHOUT CONSULTING WITH YOUR ALLERGIST OR DOCTOR BEFORE USE. THESE PRODUCTS MAY BE HAZARDOUS TO YOUR HEALTH. DO NOT USE THIS PRODUCT WHILE UNDER THE INFLUENCE OF ALCOHOL OR DRUGS, AS THIS CAN BE HAZARDOUS TO YOUR HEALTH. All products must be installed in accordance with installation instructions provided. Failure to do so may invalidate warranty at manufacturer’s discretion. ©2018 ThermaSol.
2 Tools and Materials
Parts enclosed with the Digital Shower:

Digital Shower 10.9″ x 6.93″ x 2.95″

Set of screws, 2 × 5 × 50 mm

Set of connection nipples All connections are 1/2″ NPT

Tools needed:
o Pencil o Drill bit 8 mm o Phillips head screwdriver

o Adjustable wrench o Drill o Level

50-foot CAN-bus cable

Digital Interface

Back up battery

2

Digital Shower Valve
3 Typical System Layout
Serenity Light and Sound

ThermaTouch Control (Inside Shower)

110V Power
Steam Generator
208/240VAC

TTC AUDIO OUT

24 VDC INPUT

SLS

TTC INPUT

INPUT

PDM

To LAN/ROUTER

CONTRCOOLNT1RINOPLU2TINPUT

Digital Interface

STEAM UNIT INPUT

110V Power
TDS-3000 Digital Shower Valve

Easy Start Control (Outside Shower)

Water Inlets (Hot/Cold)

Shower Outputs (3)

Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details.

THERMASOL.COM I 800.776.0711

3

Digital Shower Valve
4 Scope of Application

PDM

Digital Interface

TDS-3000 Digital Shower Valve

IMPORTANT: The Digital Shower Valve must be accessible and should not be sealed in the wall

Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details.

4

THERMASOL.COM I 800.776.0711

Digital Shower Valve
Hot Water Cold Water
Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details. THERMASOL.COM I 800.776.0711

Digital Shower Valve
Hot Water Cold Water
Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details. THERMASOL.COM I 800.776.0711

Digital Shower Valve
5 Remove Cover

15V ACCU

EXT RS-232 MOTOR
TLI

AUX

6 Inside Valve System Controller

Mounting Holes

Battery Compartment
15V ACCU

Power Supply
TLI

Connector Block

Hot Cold Inlets

Outlets

Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details.

THERMASOL.COM I 800.776.0711

7

Digital Shower Valve
7 Mark and Drill Holes
IMPORTANT: The Digital Shower Valve must be installed within 50′ of the PDM module.

235mm / 9.25″

235mm / 9.25″

8mm / 0.31″

Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details.

8

THERMASOL.COM I 800.776.0711

Digital Shower Valve
8 Install Valve System Controller

15V ACCU

EXT RS-232 MOTOR
TLI

AUX

9 Remove Inlet Retaining Bolt

15V ACCU

EXT RS-232 MOTOR
TLI

AUX

Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details.

THERMASOL.COM I 800.776.0711

9

Digital Shower Valve
10 Connect Hot and Cold Water Supply

1. Connect hot and cold water supply

2. Insert inlet connectors

15V ACCU

EXT RS-232 MOTOR
TLI

AUX

1/2″ NPT Connections

3. re-insert retaining bolt

15V ACCU EXT

IMPORTANT: Flush the pipework before connection

11 Remove Outlet Retaining Bolt

15V ACCU

EXT RS-232 MOTOR
TLI

AUX

Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details.

10

THERMASOL.COM I 800.776.0711

Digital Shower Valve
12 Connect Outlet Pipeworks
15V ACCU EXT RS-232 MOTOR TLI AUX

1/2″ NPT Connections
1. Connect outlet pipeworks

2. Insert outlet connectors

3. re-insert retaining bolt

15V ACCU

EXT RS-232

1

2 3

15V ACCU

EXT RS-232 MOTOR
TLI

AUX

2

3

1

IMPORTANT: Flush the waterlines prior to connecting to clear any debris.

Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details.

THERMASOL.COM I 800.776.0711

11

Digital Shower Valve
13 Connect Back Up Battery

15V ACCU

EXT RS-232 MOTOR
TLI

Accu
AUX

15V ACCU EXT

14 Connect The Digital Interface

Connect the digital interface to the RS232 port

15V ACCU

EXT RS-232 MOTOR
TLI

RS232 Port
AUX

15V ACCU

EXT RS-232 MOTOR
TLI

Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details.

12

THERMASOL.COM I 800.776.0711

Digital Shower Valve
15 Connect The PDM

15V ACCU

EXT RS-232 MOTOR
TLI

AUX

15V ACCU

EXT RS-232 MOTOR
TLI

Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details.

THERMASOL.COM I 800.776.0711

13

Digital Shower Valve
16 Re-fit Cover and Connect

15V ACCU

EXT RS-232 MOTOR
TLI

AUX

IMPORTANT: Electrical connection must be installed by a qualified electrician.

Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details.

14

THERMASOL.COM I 800.776.0711

Digital Shower Valve
ThermaSol Product Registration
Dear ThermaSol End User: Please register your product at www.thermasol.com/warranty so we can assist you much quicker if you ever need to contact our Technical Support Department. In addition we’ll keep you informed about your product and time to time we’ll update you about new products and other company announcements. Thank you from all of us at ThermaSol and we wish you many relaxing and steamy days ahead. We will not sell, rent or share your personal information.
1958 Steam Way Round Rock, TX 78665

Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details.

THERMASOL.COM I 800.776.0711

15

Digital Shower Valve
Product Warranty
This warranty shall extend only to the original retail purchaser or end user of the product and are contingent on the proper use of the product in accordance with the instructions and specifications published by ThermaSol and shall not apply to any product that has been repaired or modified by persons other than approved by ThermaSol. Proof of purchase from Authorized Reseller will be required to start any warranty process except where prohibited by law. These warranties are not valid for any product that is sold with defaced or altered serial number, or for any product that was purchased used, refurbished, “as is”, or in unknown condition.
All warranty claims must go through ThermaSol directly.
Limited Warranty
ThermaSol extends to the original purchaser a 1-year limited warranty to repair or replace (at its discretion) Digital Shower Vavle parts found to have manufacturing defects.
Exclusions
These warranties will be terminated by ThermaSol for the following reasons: 1. Improper installation, such as installation that fails to observe National/Local Plumbing and/or Electrical codes. 2. Use of the system in a non-residential or commercial application, including a hotel. 3. Service to equipment by unauthorized personnel. 4. Installation that does not permit proper access for service. 5. Non-payment of repairs not covered under warranty. 6. Modification to any part of the unit. 7. Use of non-ThermaSol repair parts. 8. Alteration or removal of product serial number.
Limitations
These warranties will be terminated by ThermaSol for the following reasons:
1.ThermaSol will not be liable in any way for any indirect, special, incidental, exemplary, or consequential damages resulting from the sale, delivery, installation or use of its products. Users are responsible for suitability of the products for their application.Damage resulting from improper specification or application or other operating conditions beyond ThermaSol’s control is not under warranty. 2. ThermaSol will not exercise reasonable efforts in rendering service under these warranties, but shall not be liable for any damagearising out of delays; these warranties only cover the repair and/or replacement of ThermaSol product as specified by the warranty. 3. ThermaSol does not guarantee that a local service person will be available for in-home services. Unit may have to be removed and reinstalled at owner’s expense. It is the responsibility of the buyer to file a claim with the carrier/carriers for any product that has shipping damage to or from ThermaSol. An EVA (Evaluation Number) must be obtained from the factory and used on any correspondence or packages sent to the factory. 4. THESE WARRANTIES ARE NON-TRANSFERABLE TO ANY OTHER PURCHASER OR PARTY OTHER THAN THE ORIGINAL PURCHASER FROM AN AUTHORIZED DEALER. THESE WARRANTIES ARE NOT VALID FOR ANY PRODUCTS SOLD USED, REFURBISHED, “AS IS”, OR IN UNKNOWN CONDITION. NO OTHER AGENT OR PARTY CAN GIVE ANY OTHER WARRANTY OR PROMISE. THESE ARE THE SOLE WARRANTIES FOR YOUR THERMASOL PRODUCT, EXCEPT AS PROVIDED BY LAW.
These warranties give you specific legal rights and you may also have other rights, which may vary, from state to state. Determination of rights under these warranties is in accordance with the laws of Texas. Any dispute under these warranties must be submitted and resolved by arbitration in Texas.

Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details.

16

THERMASOL.COM I 800.776.0711

Notes:

Digital Shower Valve

Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details.

THERMASOL.COM I 800.776.0711

17

Digital Shower Valve

1958 STEAM WAY ROUND ROCK, TX 78665 PHONE: 800.776.0711 | FAX: 800.556.5257 | WWW.THERMASOL.COM

81216 Rev D

Serenity Light, Sound, Rain Head

Installation Manual
For Tutorials and Troubleshooting visit www.thermasol.com/solutions SLSRRD-XX, SLSSQ-XX
OVER 60 YEARS OF STEAM SHOWER INNOVATION

Serenity Light, Sound, Rain Head Installation Instructions
1 Important Information Before You Install
PLEASE REVIEW WARNINGS BELOW AND LEAVE THIS MANUAL WITH HOMEOWNER DO NOT USE THIS PRODUCT UNLESS YOU HAVE CONSULTED WITH YOUR DOCTOR AND RECEIVED WRITTEN PERMISSION TO DO SO. USE OF THIS PRODUCT MAY BE HAZARDOUS TO YOUR HEALTH. PLEASE CONSULT YOUR PHYSICIAN BEFORE USING. IF YOU ARE PREGNANT, ELDERLY, HAVE HIGH BLOOD PRESSURE, DIABETES, SUFFERING FROM HEART DISEASE, ARE INTOXICATED, OR NOT IN GOOD HEALTH, DO NOT USE THIS STEAM BATH. STEAM IS HOT! DO NOT TOUCH OR GO NEAR THE STEAMHEAD FROM THE TIME THE UNIT IS “ON,” UP TO ONE HOUR AFTER IT HAS SHUT OFF. SEVERE BURNS WILL OCCUR IF YOU COME IN CONTACT WITH THE STEAMHEAD OR STEAM EMITTING FROM THE STEAMHEAD. NEVER ATTEMPT TO FILL AROMA RESERVOIR ON THE STEAMHEAD WHEN UNIT IS IN THE “ON” POSITION. SEVERE BURNS WILL OCCUR. DO NOT USE THERMASOL AROMATHERAPY OILS, SKIN CARE PRODUCTS OR ANY PRODUCT ASSOCIATED WITH YOUR THERMASOL UNIT WITHOUT CONSULTING WITH YOUR ALLERGIST OR DOCTOR BEFORE USE. THESE PRODUCTS MAY BE HAZARDOUS TO YOUR HEALTH. DO NOT USE STEAM ROOM WHILE UNDER THE INFLUENCE OF ALCOHOL OR DRUGS, AS THIS CAN BE HAZARDOUS TO YOUR HEALTH. YOUR SHOWER MAY BE A SLIP-AND-FALL HAZARD. CHECK WITH YOUR CONTRACTOR OR FLOORING MANUFACTURER REGARDING THE SAFE USE OF YOUR FLOORING IN A STEAM APPLICATION. SLIPPING AND FALLING INTO THE STEAMHEAD ITSELF OR INTO THE STREAM OF STEAM EMITTING FROM THE STEAMHEAD WILL CAUSE SERIOUS BURNS OR PHYSICAL INJURY. IF YOU ARE FEELING UNCOMFORTABLE, DIZZY, FAINT, OR STARTING TO FALL ASLEEP, IMMEDIATELY EXIT THE STEAM ROOM. DO NOT USE STEAM ROOM IF YOU ARE UNDER THE AGE OF 16 UNLESS SUPERVISED BY AN ADULT. THERMASOL STEAM BATH GENERATORS ARE NOT DESIGNED TO BE USED FOR SPACE HEATING PURPOSES. THERMASOL STEAM BATH GENERATORS ARE FOR INDOOR USE ONLY. THEY SHOULD NEVER BE LOCATED OUTSIDE THE HOME. ALL PRODUCTS MUST BE INSTALLED IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS PROVIDED. FAILURE TO DO SO MAY INVALIDATE WARRANTY AT MANUFACTURER’S DISCRETION. ©2016 THERMASOL.
THERMASOL.COM – 1.800.776.0711
2

Serenity Light, Sound, Rain Head Installation Instructions
2 Tools and Materials
Parts Enclosed:

Serenity Light, Sound, Rain Head fixture and hardware
Item SLSRX-XX
Compatable controls: ThermaTouch 7″ and 10″ SignaTouch Control Signature Control

Silicone

25-foot Yellow M12 Cable Item 03-7149-25

Materials needed: PDM (Item 10-8147) Compatible controller Drill 7/16″, 1/2″ and 1-1/2″ Drill Bits

Bluetooth Module

Installation instructions

Tile Cutter Ply Wood Backing Board 36″ long 3/8″ Compression Flexible Water Line Separate water volume control diverter
with shut off valve

Retaining nut Retaining washer
Retaining spring 3 1/2″ x 1/4″ threaded
rod-bolt (studs)
THERMASOL.COM – 1.800.776.0711

Tighten retaining spring to half its normal height

(Fig. 1) Installation Profile View 3

Plywood
Waterproof Backing Mortar Finished Shower Surface

Serenity Light, Sound, Rain Head Installation Instructions

3 Placing and Cutting Template

After completing the shower construction and running the necessary cables, water supplies and etc. using template included in these instructions (page 8) proceed to:
· After choosing the desired location, use the printed template
to drill the three 7/16″ holes
· Then proceed cutting the cutout
Note: Template must be printed out at actual size.
Install suitable wood support between joists.

Cutout 7/16″

25-foot Audio Cable Item 03-7140
ships with Serenity Light, Sound, Rain Head
This 25-foot Yellow M12 Cable
Item 03-7149-25 ships with Serenity Light,
Sound, Rain Head

ThermaTouch Control sold separately
This 25-foot Yellow M12 Cable Item 03-7149-25
ships with ThermaTouch control

PDM Sold and ships with ThermaTouch control as well as with the other ThermaSol wellness packages.
THERMASOL.COM – 1.800.776.0711
4

Template (see back cover)

Serenity Light, Sound, Rain Head Installation Instructions
4 Mounting Hardware
· Connect the 3 1/2″ x 1/4″ all-thread rod bolts (studs) together with
supplied couplings.
· Insert the 3 1/2″ x 1/4″ studs from the shower side into the 7/16″ pre-
drilled holes. Hold it in place while from the top side of the cut out insert supplied spring, washer and secure it with provided wing nut.
· Tighten retaining spring to half its normal height (shown on page 3)
Repeat the above steps for all three studs

5 Connecting Water Supply
NOTE: Make sure to flush out any debris from the pipe before connecting the fixture!
You will need a 36″ flex water supply that connects to your water pipe that you plumbed for the Rain Head. The connection to the Rain Head needs to be 3/8″ compression. Please connect the 36″ flex water supply from the water source to the Rain Head. Do NOT over tighten.
Slowly open the water and check for leaks before proceeding.

6 Connecting Cables

Connect the Audio cable that is connected to the ThermaTouch control.

· Red to (R), White to (L), and make sure that both cables are
connected to the same Input “1” or Input “2”.
· At this point IF you have any other audio source to be connected
please do it now to the open Input on the Rain Head.
· Next, connect the M12 power/data cable that runs or will run to the
Power Distribution Module (PDM).

Audio Cable from ThermaTouch
control

NOTE: Make sure that the “L” shaped end of M12 cable is connected to the Rain Head

THERMASOL.COM – 1.800.776.0711
5

Flex Water Supply
M12 power/data cable to PDM

Serenity Light, Sound, Rain Head Installation Instructions
7 Securing Serenity Rain Head

AUDIO CABLE

· Carefully conceal in attic space any extra lengths of
the cables or the water supply above the shower area. Align the Rain Head fixture to the three couplings. Make sure that the Rain Head will fit perfectly and flush with the ceiling. IF needed please adjust the studs and couplings to assure perfect fit.
· After you confirmed that the three couplings will
perfectly align and Rain Head will be flush with the finished ceiling material apply silicone around center groove on back of the fixture. Push fixture tight against ceiling.
· Use the three provided screws and secure them into
the fixture which will connect with the couplings. Tighten them carefully so you don’t cross thread them or you don’t damage the fixture.
· Allow silicone to dry for 24 hours.

M12 Power/ Data Cable

Silicone Bead
all around the perimeter of groove.
Push fixture tight against the ceiling.

PDM Provided and ships with ThermaTouch control

8 Connecting to Power Distribution Module (PDM)
· Make sure that the M12 power/data cable is
connected from the Rain Head to PDM
· PDM must be plugged in to standard 110V
electrical outlet
· If your control is plugged in and powered ON
you can test the lights and etc.
THERMASOL.COM – 1.800.776.0711
6

7

6

5

4

Serenity Light, Sound, Rain Head Installation Instructions Template must be full scale 1:1 when printed
7

3

2

1

1

2

3

4

5

65

7

1958 STEAM WAY ROUND ROCK, TX 78665 PHONE: 800.776.0711 | FAX: 800.556.5257 | WWW.THERMASOL .COM

81189_D

1958 STEAM WAY ROUND ROCK, TX 78665 PHONE: 800.776.0711 | FAX: 800.556.5257 | WWW.THERMASOL.COM

81238_A

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

THERMASOL User Manuals

Related Manuals