ServeRAID-MR10i SAS-SATA Controller
ServeRAID-MR10i SAS/SATA Controller (Withdrawn)
Product Guide (withdrawn product)
The ServeRAID-MR10i SAS/SATA Controller is a low-cost PCI Express RAID
controller for Internal System RAID 0, 1, 10, 5, 50, 6, and 60. This full-
height, half-length adapter uses an LSI 1078 controller with an x8 PCI Express
host interface and eight internal SAS/SATA II 3 Gb/s ports. MegaRAID Storage
Manager (MSM), included with ServeRAID-MR10i, is a robust RAID management,
configuration, and reporting application.
Figure 1 shows the ServeRAID-MR10i SAS/SATA Controller.
Did you know?
This adapter is a mainstream RAID controller offering a wide range of RAID
features and is suitable for most entry and midrange System x servers.
Part number information
Table 1. Ordering part numbers and feature codes
Description | Part number | Feature code |
---|---|---|
ServeRAID MR10i SAS/SATA Controller | 43W4296 | 3571 |
ServeRAID-MR10i NiMH Battery | 43W4299* | None |
ServeRAID-MR10i Li-Ion Battery | 44E8826 | 5864 |
- Withdrawn from marketing
Specifications
The ServeRAID-MR10i SAS/SATA Controller has the following specifications:
- Full-height (3U), half-length card
- Two internal x4 SFF-8087 connectors
- PCI Express x8 host interface
- SAS Controller: LSI 1078e
- 3 Gbps per port data transfer rate
- Supports SAS 3 Gbps and SATA 2
- 256 MB cache
- Optional battery backup; two options: NiMH (now withdrawn from marketing) or Li-Ion
- Maximum stripe size: 1024 KB
- RAID levels: RAID 0, 1, 5, 6, 10, 50, and 60
Note: Not all servers that support this controller also support the battery. See ServerProven for details.
Operating environment
The ServeRAID-MR10i SAS/SATA Controller is supported in the following environment:
-
Temperature:
At 0 – 1000 m (0 – 3000 ft): 10 – 35° C (50 – 95° F)
At 1000 – 2100 m (3000 – 7000 ft): 10 – 32° C (50 – 90° F) -
Relative humidity: 20 – 80% (non-condensing)
Warranty
The ServeRAID-MR10i SAS/SATA Controller has a one-year limited warranty. When installed on a System x server, these cards assume your system’s base warranty and any IBM ServicePac upgrade. Batteries are consumables and therefore are not covered under the warranty.
Supported servers
The ServeRAID-MR10i SAS/SATA Controller is supported on the IBM System x
servers listed in Table 2.
Table 2. Supported System x servers
‡ The ServeRAID MR10i is only supported on models of the x3250 M2 with 2.5″ drive bays. The MR10i is not supported on models with 3.5″ drive bays.
Table 2 (continued). Supported System x servers
See the IBM ServerProven website for the latest information about the adapters supported by each System x server type: http://ibm.com/servers/eserver/serverproven/compat/us/
Related publications
For more information refer to the following documents:
-
ServeRAID MR10i User’s Guide
http://www.ibm.com/support/docview.wss?uid=psg1MIGR-5074114 -
ServeRAID software and drivers
http://www.ibm.com/support/docview.wss?uid=psg1SERV-RAID -
IBM Announcement Letter
US: http://ibm.com/common/ssi/cgi- bin/ssialias?infotype=dd&subtype=ca&&htmlfid=897/ENUS108055
EMEA:
http://ibm.com/common/ssi/cgi- bin/ssialias?infotype=dd&subtype=ca&&htmlfid=877/ENUSZG08-0114
Related product families
Product families related to this document are the following:
- RAID Adapters
Notices
Lenovo may not offer the products, services, or features discussed in this
document in all countries. Consult your local Lenovo representative for
information on the products and services currently available in your area. Any
reference to a Lenovo product, program, or service is not intended to state or
imply that only the Lenovo product, program, or service may be used. Any
functionally equivalent product, program, or service that does not infringe
any Lenovo intellectual property right may be used instead. However, it is the
user’s responsibility to evaluate and verify the operation of any other
product, program, or service. Lenovo may have patents or pending patent
applications covering the subject matter described in this document. The
furnishing of this document does not give you any license to these patents.
You can send license inquiries, in writing, to:
Lenovo (United States), Inc.
8001 Development Drive
Morrisville, NC 27560
U.S.A.
Attention: Lenovo Director of Licensing
LENOVO PROVIDES THIS PUBLICATION ”AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER
EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR A PARTICULAR PURPOSE. Some
jurisdictions do not allow disclaimers of express or implied warranties in
certain transactions, therefore, this statement may not apply to you.
This information could include technical inaccuracies or typographical errors.
Changes are periodically made to the information herein; these changes will be
incorporated in new editions of the publication. Lenovo may make improvements
and/or changes in the product(s) and/or the program(s) described in this
publication at any time without notice.
The products described in this document are not intended for use in
implantation or other life support applications where malfunction may result
in injury or death to persons. The information contained in this document does
not affect or change Lenovo product specifications or warranties. Nothing in
this document shall operate as an express or implied license or indemnity
under the intellectual property rights of Lenovo or third parties. All
information contained in this document was obtained in specific environments
and is presented as an illustration. The result obtained in other operating
environments may vary. Lenovo may use or distribute any of the information you
supply in any way it believes appropriate without incurring any obligation to
you.
Any references in this publication to non-Lenovo Web sites are provided for
convenience only and do not in any manner serve as an endorsement of those Web
sites. The materials at those Web sites are not part of the materials for this
Lenovo product, and use of those Web sites is at your own risk. Any
performance data contained herein was determined in a controlled environment.
Therefore, the result obtained in other operating environments may vary
significantly. Some measurements may have been made on development-level
systems and there is no guarantee that these measurements will be the same on
generally available systems. Furthermore, some measurements may have been
estimated through extrapolation. Actual results may vary. Users of this
document should verify the applicable data for their specific environment.
© Copyright Lenovo 2022. All rights reserved.
This document, TIPS0735, was created or updated on September 29, 2010.
Send us your comments in one of the following ways:
-
Use the online Contact us review form found at:
https://lenovopress.lenovo.com/TIPS0735 -
Send your comments in an e-mail to:
comments@lenovopress.com
This document is available online at https://lenovopress.lenovo.com/TIPS0735.
Trademarks
Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.
The following terms are trademarks of Lenovo in the United States, other
countries, or both:
Lenovo®
ServeRAID
ServerProven®
System x®
Other company, product, or service names may be trademarks or service marks of
others.
ServeRAID-MR10i SAS/SATA Controller (Withdrawn) (withdrawn product)
References
- ibm.com/common/ssi/cgi-bin/ssialias
- Enterprise Business Server Solutions | IBM
- RAID Adapters > Lenovo Press
- ServeRAID-MR10i SAS/SATA Controller (Withdrawn) Product Guide (withdrawn product) > Lenovo Press
- Copyright and Trademark Information | Lenovo US | Lenovo US
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>