General safety precautions
- Disconnect the power supply before attempting any work on the unit.
- During installation, the electric power cable to be connected must not be live. Therefore, switch off the power first and use a voltage tester to make sure the wiring is off-circuit.
- Installing these lights involves work on the mains voltage supply; installation must therefore be carried out professionally in accordance with the applicable national wiring regulations and electrical operating conditions
- Only use genuine replacement parts.
- Repairs may only be made by specialist work-shops.
L 240 S / L 220 S L 220
L 240 S
L
220 S L 220
L 240 S
L 220 S L 220 L 240 S L 220 S L 220 S
Proper Use
-
Outdoor light with LEDs as the light source.
-
Suitable for wall mounting outdoors.
-
The unit is not suitable for connecting to a dimmer.
-
These sensor versions (S versions) also feature an infrared sensor for detecting movement.
Operating Principle
- Outdoor lights
- LED technology
The S versions also provide these functions
- The integrated infrared sensor detects the heat radiated from moving objects e.g. people, animals.
- The heat detected in this way is converted electronically into a signal that switches the LED light ON automatically.
- The most reliable way of detecting motion is to install the unit with the sensor aimed across the direction in which a person would walk.
- Obstacles (e.g. trees, walls etc.) interrupt the line of sensor vision.
- Heat radiation is not detected through obstacles e.g. walls or panes of glass the sensor is not triggered.
- Sudden fluctuations in temperature as a result of reach is restricted when the unit is approached head on changes in weather are not distinguished from sources of heat.
Installation
The leads consist of three wires L phase conductor (usually black, brown
or grey)
N neutral conductor (usually blue)
PE protective-earth conductor (green/yellow) If you are in any doubt, identify
the conductors using a voltage tester; then disconnect from the power supply
again. Connect the phase conductor (L) and neutral conductor (N) to the
terminal block.
L 240 S, L 220 S L 220 L 240 S, L 220 S L 240 S, L 220 S
Important
Incorrectly wired connections will produce a short circuit later on in the
product or your fuse box. In this case, you must identify the individual
conductors once again and reconnect them. A mains power switch for turning the
unit ON and OFF may of course be installed in the mains supply lead.
Note
The light source in this light must only replaced by the manufacturer or a
service engineer authorised by the manufacturer or by a similarly qualified
person.
Mounting
- Check all components for damage.
- Do not use the product if it is damaged.
- Select an appropriate mounting location, giving consideration to sensor reach and mounting height
Mounting Procedure
- Switch OFF power supply
- Detach light housing from the wall mount, paying attention to the position of the sensor
- Mark drill holes .
- Drill holes and insert wall plugs (concealed power supply cable.
- Drill holes and insert wall plugs (with spacers for surface power supply cable.
- Connect conductors.
- Connect plug-in connectors.
- Fit light enclosure (A) onto wall mount (C).
- Pay attention to plug-in connections as well as the position of the sensor.
- Screw light enclosure into place.
- Switch ON power supply.
- Make settings (S only).
Clean device with a moist cloth without detergent the control gear cannot be replaced.
Functions
The sensor-switched light can be put into service after mounting the light
enclosure and connecting to the mains power supply.
Factory settings
Twilight setting daylight operation 2000 lux Time setting 8s
Twilight setting / response threshold S only
The sensor’s response threshold can be infinitely varied from 2–2000 lux.
Control dial set to daylight operation, approx. 2000 lux. Control dial set to
night-time operation, approx. 2 lux.
Time
Light ON duration can be infinitely varied from 8 s – 35 min. It is
recommended that the shortest time be
selected for setting the detection zone. Control dial, shortest time = approx.
8 s. Control dial, longest time = approx. 35 min
Adjusting the detection zone / reach setting
Depending on the mounting height, the detection zone setting can be
optimized to suit requirements. The shroud foil can be used for masking out
any number of lens segments to limit reach as required, e.g. to mask out paths
or neighboring property .Reach can be adjusted from 2-10 m by tilting the
sensor (D) through 90° House numbers Affix the house street number using the
stickers provided
Maintenance / Care
Warning of hazards from electricity contact between water and live parts can
result in an electric shock, burns or death. Only clean device in a dry state.
Risk of damage to property
Using the wrong cleaning product can damage the light.
Disposal
Electrical and electronic equipment, accessories and packaging must be
recycled in an environmentally compatible manner.
Do not dispose of electrical and electronic equipment as domestic waste.
EU countries only under the current European directive on waste electrical and
electronic equipment and its implementation in national law, electrical and
electronic equipment no longer suitable for use must be collected separately
and recycled in an environmentally compatible manner.
Manufacturer’s Warranty
This Steinel product has been manufactured with utmost care, tested for proper
operation and safety and then subjected to random sample inspection. Steinel
guarantees that it is in perfect condition and proper working order. The
warranty period is 36 months and starts on the date of sale to the consumer.
We will remedy defects caused by material flaws or manufacturing faults. The
warranty will be met by repair or replacement of defective parts at our own
discretion. The warranty shall not cover damage to wear parts, damage or
defects caused by improper treatment or maintenance. Further consequential
damage to other objects shall be excluded.
Claims under the warranty will only be accepted if the unit is sent fully
assembled and well-packed with a brief description of the fault, a receipt or
invoice (date of purchase and dealer’s stamp) to the appropriate Service
Centre.
Troubleshooting
Malfunction | Cause | Remedy |
---|---|---|
Light without power |
- Fuse faulty, not switched ON, break in wiring
|
- Fit new fuse, turn ON mains switch, check wiring with voltage tester
Light not switching ON|
- Surroundings still too bright (S only)
- Mains switch OFF
- Fuse blown
- Detection zone not correctly adjusted (S only)
|
- Wait until response threshold is reached or adjust setting
- Switch ON
- Fit new fuse, check connection if necessary
- Readjust
Light not switching OFF|
- Continued movement within the detection zone (S only)
|
- Check detection zone and readjust if necessary
Light switches ON when it should not|
- Cars in the street are detected, for example (S only)
|
- Check detection zone and readjust if necessary
Changing reach|
- Differing ambient temperatures (S only)
|
- When it is cold, shorten reach by tilting sensor down, move it up in warm weather
Technical specifications
Technical documentation at www.steinel.de These products contain an energy efficiency class “D” light source.
References
- International | STEINEL
- Steinel Group | STEINEL
- Steinel Group | STEINEL
- International | STEINEL
- EU-Verordnung (SLR & ELR) | STEINEL
- Luminaires & Détecteurs | STEINEL
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>