steinel IS 2180-2 Indoor Detectors Instruction Manual
- June 1, 2024
- STEINEL
Table of Contents
Steiner IS 2180-2 Indoor Detectors
Dear Customer,
Congratulations on purchasing this STEINEL Infrared Sensor and thank you for
the confidence you have shown in us. You have chosen a high-quality product
that has been manufactured, tested, and packed with the greatest care. Please
familiarise yourself with these instructions before attempting to install the
sensor since prolonged reliable and trouble-free operation will only be
ensured if it is installed properly. We hope your new Infrared sensor will
give you lasting satisfaction.
System components
- Security screw
- Front cover
- Lens (can be removed and turned to select the max. basic reach settings of 5 m or 12 m)
- Light threshold setting control 2–2,000 lux
- Time setting control
- 5 sec. –15 min.
- Clip (housing can be flipped up for assembly and connection to the main power supply)
Technical specifications
Principle
The IS 2180-2 is equipped with two 120° pyro sensors which detect the
invisible heat emitted by moving objects (people, animals, etc.). The heat
detected is electronically converted into a signal that switches on loads
(e.g. a light) connected to it. Heat is not detected through obstacles, such
as walls or panes of glass.
Heat radiation from this type will, therefore, not trigger the sensor. With a 90° angle of the aperture, the two pyro sensors cover a detection angle of 180°. The lens can be removed and turned, thereby permitting two max. basic reach settings of 5 m or 12 m. With the separately available wall brackets, the infrared sensor can be easily mounted on the inside and outside corners.
Important : The most reliable way of detecting motion is to install the
unit so that the sensor is aimed across the direction in which a person would
walk and by ensuring that no obstacles (such as trees, walls, etc.) obstruct
the line of sensor vision.
Safety warnings
- Disconnect the power before attempting any work on the motion detector.
- The electrical connection lead must be dead during installation.
- Therefore, switch off the power supply first and check that the circuit is disconnected using a voltage tester.
- Installation of the sensor involves work on the main power supply.
- This work must therefore be carried out professionally by the applicable wiring regulations and supply conditions.
- (DE-VDE 0100, AT-ÖVEEN 1, CH-SEV 1000)
- Please note that the sensor must be protected by a 10 A circuit breaker.
- The main supply lead must be no greater than 10 mm in diameter.
- Only carry out time and light threshold settings with the lens fitted.
Installation / Wall mounting
The site of installation should be at least 50 cm from light because heat
radiated from it may trigger the sensor unintentionally. To obtain the
specified ranges of 5 / 12 m, the the sensor should be installed at a height
of approx. 2 m.
Installation procedure
- Detach front cover 2
- Release clip 6 and flip up the lower half of the housing
- Mark drill hole
- Drill the holes, insert wall plugs (6 mm dia.)
- Break open cable entry for surface or concealed wiring.
- Feed through mains supply and service cable and connect to terminals. Use sealing plugs for surface wiring.
- a) Connect mains supply lead
- The mains supply leads is a 2 to 3-core cable:
- L = phase conductor
- N = neutral conductor
- PE = protective-earth
- conductor ( )
- If you are in any doubt, you must identify the cables using a voltage tester; once you have done so, disconnect the power supply again. Connect the phase (L) and neutral conductor (N) to the clamp-type terminal. Connect the protective earth conductor to the earth terminal ( ).
- A power ON / OFF switch may of course be installed in the power supply lead. Alternatively, you may use a normally closed contact pushbutton to activate the sensor manually for the duration of the time setting.
Note: The separately available inside the corner wall bracket can also be used for wall mounting.
In this way, the cables can be conveniently routed behind the device from
above and through the opening of the surface-mounted cable feed line. Connect
service lead The service supply lead to the light is also a 2-to 3-core cable.
Connect the light’s current-carrying conductor to the terminal
marked L’. The service lead neutral conductor must be connected to the
terminal marked N together with the mains lead neutral conductor. Connect the
protective earth conductor to the earth contact ( ). Screw on the housing and
close again. Fit lens (set reach to either 5 m or 12 m max),
see ‘Reach setting’ section. Select time 5 and light threshold setting 4 (see
‘Functions’ section). Locate front cover 2 and fit security screw 1 to protect
the cover from unauthorized removal. Important: Reversing the connections may
result in damage to the unit.
Installation using a corner wall mount
With the corner wall brackets, the IS 2180-2 can be conveniently mounted on
inside and outside corners. Use the corner wall bracket as a drilling template
when drilling the holes. In this way, you place the drill hole at the right
angle and the corner wall bracket can be mounted without any problems. The
corner wall brackets (EAN 40071085131 black / 40071085148 white) are available
as accessories.
Functions
Once you have connected the unit to the mains power supply closed the
housing and fitted the lens, you are ready to put the system into operation.
Two setting controls are concealed behind the front cover 2.
Important: Only carry out time and light threshold settings with the lens
fitted. Switch-off delay (time setting) The chosen light ON time can be varied
continuously from approx. 5 sec. to a maximum of 15 min. Turning the
adjustment screw fully anti-clockwise selects the shortest time of approx. 5
sec., turning the adjustment screw fully clockwise for the longest time of
approx. 15 min. The shortest time setting is recommended for setting the
detection zone and performing the walk test.
Twilight setting (response threshold)
The chosen detector response threshold can be adjusted continuously from
approx. 2 lux to 2,000 lux. Turning the adjustment screw fully anti-clockwise
selects daylight operation at approx. 2,000 lux. Turning the adjustment screw
fully clockwise selects twilight operation at approx. 2 lux. The adjustment
screw must be turned fully anti-clockwise for setting the detection zone and
performing the walk test in daylight.
Basic reach settings
The lens of the IS 2180-2 is divided into two detection zones. One-half covers
a max. reach of 5 m, the other half a max. reach of 12 m (when installed at a
height of approx. 2 m). After fitting the lens (press the lens firmly into the
channel provided) you will see the max. reach setting (12 m or 5 m) at the
bottom right. Using a screwdriver, the lens can be unclipped from the groove
at the side and re-positioned for the reach you require.
Examples
Precision adjustment using shrouds
Shrouds may be used to define the detection zone exactly as you require in
order, for example, to blank out or specifically target paths or neighboring
premises. The shrouds can be divided or cut with a pair of scissors along the
vertical and horizontal grooves. They can be clipped into the top channel
around the center of the lens. They are fixed in place by fitting the front
cover. (See below: Examples showing how to reduce the angle of detection and
shorten the reach).
Examples
Wiring examples
- Light without a neutral conductor
- Light with a neutral conductor
- Connection using series switch for manual and automatic operation
- Connection to double-throw switch for permanent light ON and automatic operation
Setting I: automatic operation
Setting II: manual operation for permanent light ON
Important: the unit cannot be switched OFF but operated only at settings
I and II.
- e.g. 1–4 × 100 W filament bulbs
- Service load, light of 1.000 W max. (see Technical specifications)
- IS 2180-2 connection terminals
- Indoor switch
- Indoor series switch, manual, automatic
- Indoor double-throw switch, automatic, permanent light ON
Operation / Maintenance
The Infrared Sensor is suitable for switching light on and off automatically. The unit is not suitable for special burglary alarm systems since it lacks the tampering protection prescribed for this purpose. Weather conditions may affect the way the motion detector works. Strong gusts of wind, snow, rain, or hail may cause the light to come on when it is not wanted because the sensor is unable to distinguish sudden changes of tem-perature from sources of heat. The detector lens may be cleaned with a damp cloth if it gets dirty (do not use cleaning agents).
Troubleshooting
Disposal
Electrical and electronic equipment, accessories, and packaging must be
recycled in an environmentally compatible manner. Do not dispose of electrical
and electronic equipment as domestic waste.
EU countries only
Under the current European Directive on Waste Electrical and Electronic
Equipment and its implementation in national law, electrical and electronic
equipment no longer suitable for use must be collected separately and recycled
in an environmentally compatible manner. 6. Manufacturer’s Warranty
Manufacturer’s warranty of STEINEL GmbH, Diesel- Strasse 80-84, DE-33442
Herzebrock-Clarholz, Germany
All STEINEL products Meet the highest quality standards. For this reason, we, the manufacturer, are pleased to provide you, the customer, with a warranty under the following terms and conditions: The warranty covers the absence of deficiencies that are proven to be the result of a material defect or fault in manufacturing and which are reported to us immediately after detection and within the warranty period. The warranty shall cover all STEINEL Professional products sold and used in Germany.
Our warranty covers for consumers The provisions below apply to consumers. A consumer is any natural person who, on entering into the purchase transaction, neither acts in exercising their commercial nor their self-employed activity. You can opt for a warranty cover in the form of a repair or replacement which will be provided free of charge (if applicable, in the form of a successor model of the same or higher quality) or in the form of a credit note. In the case of sensors, floodlights, and outdoor and indoor lights, the warranty period for the STEINEL Professional product you have purchased is 5 years for hot-air and hot-melt gluing products: 1 year in each case from the date on which the product was purchased. We shall bear the shipping costs but not the transport risks involved in the return shipment.
Our warranty covers entrepreneurs
The provisions below apply to entrepreneurs. An entrepreneur is a natural or
legal person or partnership with a legal personality who, on entering into the
purchase transaction, acts in exercising their or its commercial or self-
employment activity. We have the option of providing warranty cover by
rectifying deficiencies free of charge, replacing a product free of charge (if
applicable, in the form of a successor model of the same or higher quality),
or issuing a credit note. In the case of sensors, floodlights, outdoor and
indoor lights, the warranty period for the STEINEL
The professional product you have purchased is 5 years for hot-air and hot-
melt gluing products: 1 year in each case from the date on which the product
was purchased.
Within the scope of warranty cover, we shall not bear your expenses accruing from subsequent fulfillment nor shall we bear your expenses for removing the defective product and installing a replacement product. Statutory rights accruing from defects, and gratuitousness The warranty cover description here shall be applicable in addition to the statutory rights of warranty – including special consumer protection provisions – and shall not restrict or replace them. Exercising your statutory rights in the event of defects is gratuitous.
Manufacturer’s warranty
Exemptions from the warranty All replaceable lamps are expressly excluded from
this warranty. In addition to this, the warranty shall not cover:
- any wear resulting from the use or any other natural wear of product parts or any deficiencies in the STEINEL Professional product that are attributable to wear caused by the use of other natural wear,
- any improper or unintended use of the product or any failure to observe the operating instructions, any unauthorized additions, alterations, or other modifications to the product, or any deficiencies attributable to the use of accessory, supplementary, or replacement parts that are not genuine STEINEL parts,
- any maintenance or care of products that are not carried out by the operating instructions,
- any attachment or installation that is not by STEINEL’s installation instructions, any damage or loss occurring in transit. Application of German law
- The warranty shall be governed by German law excluding the United Nations Convention concerning the International Sale of Goods (CISG).
- Making claims If you wish to make a warranty claim, please send your product complete and carriage paid with the original receipt of purchase, which must show the date of purchase and product designation, either to your retailer or directly to us at STEINEL (UK) Ltd. – 25 Manasty Road, Axis Park, Orton Southgate, GBPeterborough Cambs PE2 6UP United Kingdom.
- For this reason, we recommend that you keep your receipt of purchase in a safe place until the warranty period expires.
References
- Avalehele
- russland.RU Verlag
- Steinel Group | STEINEL
- STEINEL | Steinel Grupul
- F.Fonseca - High-tech Solutions since 1978
- SAOS Teknoloji STEINEL Türkiye Distribütörü | SAOS Teknoloji
- 【steinel 】施特朗中国官方网站
- Steinel Group | STEINEL
- International | STEINEL
- Ташев-Галвинг ООД: магазин за машини, инструменти, строителни материали, крепежи и градинска техника
- www.veleprodaja-ep.si