steinel RS LED M1 Ceiling Lamp User Guide
- June 3, 2024
- STEINEL
Table of Contents
steinel RS LED M1 Ceiling Lamp User Guide
About this document
Please read carefully and keep in a safe place.
- Under copyright. Reproduction either in whole or in part only with our consent.
- Subject to change in the interest of technical progress.
Symbols
Hazard warning!
Reference to other information in the document
General safety precautions
Disconnect the power supply before attempting any work on the unit.
-
During installation, the electric power cable being connected must not be live. Therefore, switch off the power first and use a voltage tester to make sure the wiring is off-circuit.
-
Installing the sensor-switched light involves work on the mains supply voltage. This work must therefore be carried out professionally in accordance with national wiring regulations and electrical operating conditions.
(e.g.: : VDE 0100, : ÖVE / ÖNORM E8001-1, : SEV 1000) -
Only use genuine replacement parts.
-
Repairs may only be made by specialist workshops.
RS LED M1
Proper use
- Sensor-switched indoor light with active motion detector for installing indoors.
Note:
Make sure that the light is installed at a minimum distance of 3 m from any
Wi-Fi routers or Access Points.
The integrated HF sensor emits high-frequency electromagnetic waves (5.8 GHz )
and receives their echo. The change in echo caused by the slightest movement
within the detection zone of the light is detected by the sensor.
A microprocessor then issues the switch command “switch light ON”. Detection
is possible through doors, panes of glass or thin walls.
Note:
The high-frequency power of the HF sensor is approx. 1 mW – that is 1000 times
less than the transmission power of a mobile phone or microwave oven.
Package contents
M1 (Fig. 3.1)
Sensor-switched light
3 screws
3 wall plugs
3 spacers
Product dimensions M1 (Fig. 3.2)
Product components M1 (Fig. 3.3)
A Shade
B Electronics enclosure
C HF sensor
D Connecting terminal
E Basic light level
F Time setting
G Reach setting
H Twilight setting
Detection zones for ceiling mounting
M1: Ø 3-8 m (Fig. 3.4)
Detection zones for wall mounting
M1: 2.5 m (Fig. 3.5)
Detection zones may vary slightly depending on type of enclosure used.
Luminous intensity distribution (Fig. 3.6 )
Electrical connection
Wiring diagram (Fig. 4.1)
The mains power supply lead is a 3-core cable:
L = Phase conductor (usually black, brown or grey )
N = Neutral conductor (usually blue)
PE = Protective-earth conductor (green/yellow)
If you are in any doubt, identify the conductors using a voltage tester; then
disconnect from the power supply again.
Connect the phase conductor and neutral conductor to the terminal block.
Important:
incorrectly wired connections will produce a short circuit later on in the
product or your fuse box. In this case, you must identify the individual
conductors once again and reconnect them. A mains power switch for turning the
unit ON and OFF may of course be installed in the mains supply lead.
The light source of this luminaire cannot be replaced. If the light source
needs to be replaced (e.g. at the end of its service life), the complete
luminaire must be replaced.
Connection to a dimmer will result in damage to the sensor-switched light.
Mounting
- Check all components for damage.
- Do not use the product if it is damaged.
- When installing the sensor-switched light, make sure the installation site is not exposed to vibration.
- Select an appropriate mounting location, taking the reach and motion detection into consideration.
Mounting procedure
-
Switch OFF power supply (Fig. 4.1)
-
Mark drill holes (Fig. 5.1)
-
Drill holes and insert wall plugs (Fig. 5.2)
-
Installation with concealed power supply lead (Fig. 5.3)
-
Installation with surface-mounted power supply lead (Fig. 5.4)
-
Connect conductors (Fig. 5.5)
-
Switch ON power supply (Fig. 5.7)
-
Make settings (Fig. 5.6) – Settings ➔ “6. Function”
-
Fit shade (Fig. 5.7)
Function
- Factory settings:
- Time setting: 5 seconds
- Reach setting: M1: max. 8 m
- Twilight level: 2000 lux
- Basic light level: OFF
The sensor-switched light can be put into service after mounting the enclosure and connecting to the mains power supply. When putting into operation manually at the mains switch, the light will switch OFF after 10 seconds for the calibration phase and is then activated for sensor mode. It is not necessary to operate the mains switch a second time.
Function – control dials (Fig. 6.1)
Time setting (stay-ON time) (Fig. 6.1/G)
The light’s ON time can be set to any period from approx.
5 seconds to a maximum of 15 minutes. Any movement detected before this time
elapses will restart the timer.
Note:
After the light switches OFF, it takes approx. 1 second before it is able to
start detecting movement again. The light will only switch ON in response to
movement once this period has elapsed.
The shortest time setting is recommended when adjusting the detection zone and
performing the functional test.
Reach setting (sensitivity) (Fig. 6.1/H)
Reach is the term used to describe the diameter of the more or less circular
detection zone produced on the ground for a mounting height of 2.5 m.
- Control dial set to maximum = max. reach (M1 ; 8 m)
- Control dial set to minimum = min. reach (M 1 : 2.50 m)
Twilight setting (response threshold) (Fig. 6.1/I)
The light’s chosen response threshold can be infinitely varied from
approximately 2 to 2000 lux.
- Control dial set to = daylight mode (depending on ambient brightness )
- Control dial set to = twilight mode (approx. 2 lux ) The control dial must be turned to when adjusting the detection zone and performing the functional test in daylight.
Basic light level function (Fig. 6.1/J)
The basic light level function provides illumination at approx. 10% light
output when the brightness setting is reached.
Movement in the detection zone switches the light ON at 100% brightness for
the time selected.
Light switches OFF completely after the selected time has elapsed. If the
brightness setting has not yet been reached, basic light is switched back ON
again.
- Control dial set to = basic light level ON
- Control dial set to 0 = basic light level OFF
Basic light is ON when the level of light falls below the brightness threshold. Basic light is always ON when daylight mode is activated.
Basic light switches OFF every hour to measure ambient brightness. Basic light switches back ON again after a short period.
Manual override function
If an optional mains switch is installed in the mains supply lead, the
following functions are available in addition to simply switching light ON and
OFF:
Manual override (Fig. 6.2)
-
Activate manual override:
Switch OFF and ON twice. The light is set to manual override for 4 hours. Then it returns automatically to sensor mode. -
Deactivate manual override:
Switch OFF and ON once. Light goes out or switches to sensor operation.
Important:
Switching must take place within 0.2 to 1 second
Disposal
Electrical and electronic equipment, accessories and packaging must be
recycled in an environmentally compatible
manner.
Do not dispose of electrical and electronic equipment as domestic waste.
EU countries only
Under the current European Directive on Waste Electrical and Electronic
Equipment and its implementation in national law, electrical and electronic
equipment no longer suitable for use must be collected separately and recycled
in an environmentally compatible manner.
Important note: the control gear cannot be replaced.
Declaration of Conformity
STEINEL Vertrieb GmbH hereby declares that the RS LED M1 radio equipment type conforms to Directive 2014/53/EU. The full wording of the EU Declaration of Conformity is available for downloading from the following Internet address: www.steinel.de
Manufacturer’s warranty
This Steinel product has been manufactured with utmost care, tested for proper
operation and safety and then subjected to random sample inspection. Steinel
guarantees that it is in perfect condition and proper working order.
The warranty period is 36 months and starts on the date of sale to the
consumer. We will remedy defects caused by material flaws or manufacturing
faults. The warranty will be met by repair or replacement of defective parts
at our own discretion. The warranty shall not cover damage to wear parts,
damage or defects caused by improper treatment or maintenance. Further
consequential damage to other objects shall be excluded.
Claims under the warranty will only be accepted if the unit is sent fully assembled and well-packed with a brief description of the fault, a receipt or invoice (date of purchase and dealer’s stamp) to the appropriate Service Centre.
Repair service:
If defects occur outside the warranty period or are not covered by warranty,
ask your nearest service station for the possibility of repair.
Technical specifications
Dimensions (H × W × D)| M1: 200 × 200 × 53 mm
Supply voltage| 220 – 240 V, 50 / 60 Hz
Power consumption (Pon)| 8.80 W
Luminous flux *| M1: 759 lm
Efficiency| M1: 86 lm/W
Standby sensor (Psb)| 0.39 W
Mains current| 46.50 mA AC
Power factor| 0.93
Colour temperature| 3,000 K (warm white)
Colour rendering index| Ra = 82
Average rated life expectancy| L70B50 at 25°C: >60,000 hours
Colour consistency SDCM| Starting value: 3
Luminous intensity distribution
HF technology| 5.8 GHz (responds to the slightest movement regardless of
temperature)
Angle of coverage| 360° with 160° angle of aperture
Transmitter power| approx. 1 mW
Detection reach| Ø 3-8 m
Time setting| 5 s – 15 min
Twilight setting| 2 – 2,000 lux
Basic light level| 10 %
IP rating| IP20
Protection class| II
Ambient temperature| -10°C to +40°C
Energy efficiency class| This product contains an energy efficiency class “F”
light source.
Troubleshooting
Malfunction | Cause | Remedy |
---|---|---|
Sensor-switched light without power |
- Fuse has tripped, not switched ON, break in wiring
- Short circuit in mains power supply lead
- Any mains switch OFF
|
- Activate, change fuse, turn ON mains switch, check wiring with voltage tester.
- Check connections
- Switch on mains switch
Sensor-switched light will not switch ON|
- Incorrect twilight setting selected
- Mains switch OFF
- Fuse has tripped
|
- Readjust
- Switch ON
- Activate, change fuse, check connection if necessary
Sensor-switched light will not switch OFF|
- Continued movement within the detection zone
|
- Check detection zone
Sensor-switched light switches ON without any identifiable movement|
- Light not mounted for detecting movement reliably
- Movement occurred, but not identified by the sensor ( movement behind wall, movement of a small object in immediate lamp vicinity etc. )
|
- Securely mount enclosure
- Check detection zone
Sensor-switched light does not switch ON despite movement|
- Rapid movements are suppressed to minimize malfunctioning or detection zone set too small
- Incorrect twilight setting selected
|
- Check detection zone
- Readjust