About this document

Please read carefully and keep in a safe place.

  • Under copyright. Reproduction either in whole or in part only with our consent.
  • Subject to change in the interest of technical progress.
  • All product dimensions in mm.

Symbols

Hazard warning!

Reference to other information in the document.

Note:
Diagrams without captions apply to all versions.

General safety precautions


Disconnect the power supply before attempting any work on the unit.

  • Installing the LED floodlight involves work on the mains voltage supply; installation must therefore be carried out professionally in accordance with the applicable national wiring regulations and electrical operating conditions (DE-VDE 0100, AT-ÖVE/ÖNORM E 8001-1, CH-SEV 1000).
  • The LED floodlight must be positioned so that it is not expected that anybody can stare into the light for any prolonged period from a distance of less than 0.3 m.
  • The floodlight enclosure heats up when the light is on. Only adjust the angle of the LED panel once it has cooled down.
  • Do not install the LED floodlight on (normally) flammable surfaces.

XLED home 2/XLED home 2 XL XLED home 2 SL XLED home 2 Connect

Proper use

  • LED floodlight suitable for wall mounting outdoors.
  • Fully swivelling LED panel.
  • Can be used on its own or interconnected with other floodlights.

XLED home 2/XLED home 2 XL

  • Wired interconnection.
  • Operation via control dial.

XLED home 2 Connect

  • Wireless interconnection (<100 m).
  • Operation via Smart Remote app.

Master versions

  • The sensor-switched LED floodlight contains an infrared motion detector.

Movement triggers lights, alarms and many other devices. With the fully swivelling panel, the LED floodlight can be used at home to provide perfect illumination for lighting up property, or commercially for lighting up business premises. In conjunction with the opal cover, this extremely efficient technology provides wide-area lighting.

Models

  • XLED home 2/XLED home 2 XL
  • XLED home 2 SL
  • XLED home 2 Connect

Package contents for master versions (Fig. 3.1)
Package contents
Package contents for slave version (Fig. 3.2)
Package contents

Adjustment range for floodlight head and sensor-switched master (Fig. 3.3/3.4/6.2/6.3/6.6)
Dimensins
Dimensins

Adjustment range for slave floodlight head (Fig. 3.5/3.6/6.2)
Dimensins
Dimensins

Product dimensions, master (Fig. 3.7/3.8)
Dimensins
Dimensins

Product dimensions, slave (Fig. 3.9/3.10)
Dimensins
Dimensins

Product components, master (Fig. 3.11)

Product Components

A LED panel
B Enclosure
C Wall mount
D Sensor unit
E Time setting (XLED home 2/XLED home 2 XL)
F Twilight setting (XLED home 2/XLED Home 2 XL)

Product components, slave (Fig. 3.12)

A LED panel
B Enclosure
C Wall mount

Electrical installation

Switch OFF power supply. (Fig. 4.1)

Switch OFF power

Connecting the mains power supply lead
The supply lead is a 2 or 3-core cable:

  • L = phase conductor (usually black, brown or grey)
  • L’ or   = phase conductor (usually black, brown or grey), in master/master or master/slave mode only. Mains supply lead is used as connection lead for switching output.
  • N = neutral conductor (usually blue)
  • PE = protective-earth conductor (green/ yellow)

Note:
The protective-earth conductor need not be connected for this product.

Wiring diagram, master/slave (Fig. 4.2)
Wiring diagram
Wiring diagram, master/master (Fig. 4.3)
Wiring diagram

Wiring diagrams, slave (Fig. 4.4)
Wiring diagram

Wiring diagram, XLED home 2 Connect (Fig. 4.5)
Wiring diagram

Important:
Incorrectly wired connections will produce a short circuit later on in the LED floodlight or your fuse box. In this case, you must identify the individual conductors once again and reconnect them. The light source of this LED floodlight cannot be replaced. If the light source needs to be replaced (e.g. at the end of its service life), the complete LED floodlight must be replaced.

Installation

  • Check all components for damage.

  • Do not use the product if the LED floodlight is damaged.

  • Select an appropriate mounting location, taking the reach and motion detection into consideration. (Fig. 5.1/5.2/5.3)
    Installation Installations
    Installation Installations
    Installation Installations

  • Align the LED floodlight. (Fig. 5.4)
    Installation Installations

The most reliable way to detect movement is given by mounting the LED floodlight to point across the direction in which people walk and by making sure no obstacles (e.g. trees, walls etc.) interrupt the line of sensor vision. (Fig. 5.2/5.3)

Mounting procedure

  • Switch OFF power supply. (Fig. 4.1)

  • Undo retaining screw. (Fig. 5.5)
    Mounting procedure 

  • Detach enclosure (B) from wall mount (C). (Fig. 5.6)
    Mounting procedure 

  • Detach plug-in terminal from wall mount. (Fig. 5.7)
    Mounting procedure 

  • Mark drill holes. (Fig. 5.8)
    Mounting procedure 

  • Drill holes and fit ground plugs. (Fig. 5.9)
    Mounting procedure 

  • Fit sealing plug. (Fig. 5.10)
    Mounting procedure 

    • Power supply lead, concealed (Fig. 5.11)
      Mounting procedure 

    • Power supply lead, surface-mounted, with spacers (Fig. 5.12)
      Mounting procedure 

  • Connect conductors.

    • XLED home 2/XLED home 2 XL (Fig. 5.13) An additional external load can be connected to N und L’/.
      Mounting procedure 

    • XLED home 2 Connect/XLED home 2 SL (Fig. 5.14)

  • Connect plug-in terminal. (Fig. 5.15)
    Mounting procedure 

  • Fit enclosure onto wall mount. (Fig. 5.16)
    Mounting procedure 

  • Screw in locking screw. (Fig. 5.17)

  • Switch ON power supply. (Fig. 5.17)
    Mounting procedure 

  • Make settings ➜ “6. Function“

Function

XLED home 2/XLED home 2 XL
XLED home 2 SL

Factory settings

Time setting (E): 8 seconds
Twilight setting (F): 2000 lux, (daytime mode)

Time setting (Fig. 6.1/E)
Time setting

The time you want the LED floodlight to stay on for (main light) is infinitely adjustable from approx. 8 seconds to a maximum of 35 minutes. Any movement detected before this time elapses will restart the timer.

  • Control dial set to + = longest time, approx. 35 minutes
  • Control dial set to – = approx. 8 seconds

Twilight setting (Fig. 6.1/F)
The LED floodlight’s chosen response threshold can be infinitely varied from approx. 2 to 1000 lux

  • Control dial set to = daylight operation (independent of ambient brightness)
  • Control dial set to = night-time operation (approx. 2 lux)

The control dial must be turned to when adjusting the detection zone and performing the functional test in daylight.

Note:
When setting the detection zone, we recommend selecting the shortest time.

Note:
After the LED floodlight switches OFF, it takes approx. 1 second before it is able to start detecting movement again. The LED floodlight will only switch ON in response to movement once this period has elapsed.

XLED home 2 Connect
Factory settings
Twilight setting: 2000 lux, daytime mode, lux teach Time setting: 5 seconds

Reach setting/adjustment
The detection zone can be optimised to suit requirements.

Sensor unit

  • Sensor unit swivels through 180°. (Fig. 6.3)
    Sensor unit 

  • Sensor unit tilts through 90°. (Fig. 6.6)
    Sensor unit 

Adhesive shroud (Fig. 6.4)

The film shroud can be used for masking out any number of lens segments to limit reach as required. Inadvertent triggering is ruled out or the sensor can be targeted to watch over danger spots (Fig. 6.5). Other information:
Adhesive shroud

Other information:

Floodlight adjustment range (Fig. 6.2)
Other information

Setting functions

  • Setting via control dial (XLED home 2)
  • Setting via Smart Remote app (XLED home 2 Connect)

Note:
The settings last selected on the control will be used.

Smart Remote app
To configure the LED floodlight via smartphone or tablet, you must download the STEINEL Smart Remote app from your app store. You will need a Bluetooth- capable smartphone or tablet.

Additional functions only via the

Android

QR Code

iOS

QR Code

Smart Remote app:

  • Twilight setting 2 – 2000 lux, daytime mode, lux teach, time teach
  • Time setting 5 s – 60 min
  • ON / OFF times based on time of day
  • Night economy mode
  • Reach setting based on sensitivity
  • Group interconnection and naming lights / groups
  • Manual override 4h ON / 4h OFF
  • Password protection

The functions of the LED floodlight can be set via smartphone or tablet. Bluetooth interconnection is only possible via smartphone or tablet.

Note:
After the LED floodlight switches OFF, it takes approx. 1 second before it is able to start detecting movement again. The LED floodlight will only switch ON in response to movement once this period has elapsed.

The XLED home 2 Connect has an internal clock for time-based activation and deactivation. This automatically synchronises with the clock of the connected smartphone via the Smart Remote app each time a Bluetooth connection is established.

To ensure correct function following an interruption in the LED floodlight’s power supply, it must be re-connected via the Smart Remote app. The internal clock is re-synchronised with the smartphone clock.

Operation/maintenance

The LED floodlight is not suitable for burglar alarm systems as it is not tamperproof in the manner prescribed for such systems. Weather conditions may affect the way the LED floodlight works. Strong gusts of wind, snow, rain and hail may cause the light to come ON when it is not wanted because the sensor is unable to distinguish between sudden changes in temperature and sources of heat. The detector lens may be cleaned with a damp cloth if it gets dirty (do not use cleaning agents).

Disposal

Electrical and electronic equipment, accessories and packaging must be recycled in an environmentally compatible manner.

Symbol
Do not dispose of electrical and electronic equipment as domestic waste.

EU countries only:
Under the current European Directive on Waste Electrical and Electronic Equipment and its implementation in national law, electrical and electronic equipment no longer suitable for use must be collected separately and recycled in an environmentally compatible manner.

Declaration of Conformity

STEINEL Vertrieb GmbH hereby declares that the XLED home 2 Connect radio equipment type conforms to Directive 2014/53/EU. The full wording of the EU Declaration of Conformity is available for downloading from the following Internet address: www.steinel.de

Manufacturer’s Warranty

This STEINEL product has been manufactured with utmost care, tested for proper operation and safety and then subjected to random sample inspection. Steinel guarantees that it is in perfect condition and proper working order. The warranty period is 5 years and starts on the date of sale to the consumer. We will remedy defects caused by material flaws or manufacturing faults. The warranty will be met by repair or replacement of defective parts at our own discretion. The warranty shall not cover damage to wear parts, damage or defects caused by improper treatment or maintenance. Further consequential damage to other objects shall be excluded. Claims under the warranty will only be accepted if the unit is sent fully assembled and well-packed with a brief description of the fault, a receipt or invoice (date of purchase and dealer’s stamp) to the appropriate Service Centre.

Service:
Our Customer Service Department will repair faults not covered by warranty or after the warranty period. Please send the product well-packed to your nearest Service Centre.

5 YEAR
MANUFACTURER’S
WARRANTY

Technical specifications

| XLED Home 2| XLED Home 2 XL| XLED Home 2 Connect| XLED Home 2 SL
---|---|---|---|---
Dimensions (H × W × D)| 218 × 180 × 161| 240 × 180 × 161| 218 × 180 × 161| 181 × 180 × 161
Output/efficiency| 14 W / 106 lm/W| 20 W / 106 lm/W| 13.5 W / 109 lm/W| 13 W / 111 lm/W
Luminous flux / brightness| 1484 lm| 2120 lm| 1472 lm| 1443 lm
Power consumption| 0.55 W| 0.55 W| 0.35 W| –
Weight| 0.575 kg| 0.620 kg| 0.575 kg| 0.480 kg
Area illuminated| Front view| Front view| Front view| Front view
| 283.1 cm2| 316.2 cm2| 283.1 cm2| 274.1 cm2
| Side view| Side view| Side view| Side view
| 113 cm2| 115 cm2| 113 cm2| 86.3 cm2
Mains current| 79 mA| 103 mA| 69 mA| 66 mA
Power factor| 0.77| 0.85| 0.86| 0.86
Additional swit-| Incandescent / halogen lamp load| 1000 W|
ching capacity| Fluorescent-lamp electronic ballasts| 430 W|
| Fluorescent lamps, uncorrected| 500 VA|
XLED home 2| Fluorescent lamps, series-corrected| 900 VA|
XLED home 2 XL| Fluorescent lamps, parallel-corrected| 500 VA|
| Low-voltage halogen lamps| 1000 VA|
| LED < 2 W| 16 W|
| 2 W < LED < 8 W| 64 W|
| LED > 8 W| 64 W|
| Capacitive load| 88 μF|
Colour temperature| 3000 K (warm white)
Colour rendering index| Ra ≥ 80
Supply voltage| 220-240 ~V / 50/60 Hz
Sensor system| Passive infrared
Reach| max. 10 m
Angle of coverage| 180°
Time setting| 8 s – 35 min (XLED home 2 Connect 5 s -60 min)
Twilight setting| 2-2000 lux
IP /protection class| IP44 / II
Bluetooth frequency| | 2.4-2.48 GHz|
Bluetooth trans- mitter power| | 5 dBm/3 mW|

Troubleshooting

Malfunction Cause Remedy

LED floodlight without power

  • Fuse has blown,not switched ON, break in wiring
  • Short circuit

|

  • New fuse, turn on power switch, check wiring with voltage tester
  • Check connections

Sensor-switched LED floodlight will not switch ON|

  • Twilight setting in night-time mode during daytime operation
  • Mains switch OFF
  • Fuse blown
  • Detection zone not correctly adjusted

|

  • Reset
  • Switch ON
  • Replace fuse, check connection if necessary
  • Readjust

Sensor-switched LED floodlight will not switch OFF|

  • Continued movement within the detection zone

|

  • Check zone and readjust if necessary or apply shroud

Sensor-switched LED floodlight keeps switching ON and OFF|

  • Animals moving in detection zone

|

  • Tilt sensor higher or fit shrouds to target sensor; adjust detection zone or fit shrouds

Sensor-switched LED floodlight switches ON when it should not|

  • Wind is moving trees and bushes in the detection zone
  • Cars in the street are detected
  • Sudden temperature changes due to weather (wind, rain, snow) or air expelled from fans, open windows
  • Sensor-switched LED floodlight swaying (moving), resulting, for example, from gusts of wind or heavy precipitation

|

  • Change detection zone
  • Change detection zone
  • Adjust detection zone or install in a different place
  • Fit sensor-switched LED floodlight to a firm surface

LED floodlight is now shown

  • Incorrect region selected in the Bluetooth listing

|

  • Settings? Region EU/Region US

Forgotten password?|

  • After entering wrong password: “Reset password” button; switch power supply OFF and back ON again within 10 minutes; thenre-enter password

App won’t start|

  • Location is not activated

|

  • Activate location in smartphone settings

Settings for LED floodlight are greyed out|

  • LED floodlight is not declared as group master (slave mode)

|

  • Set master floodlight
  • Declare LED floodlight as master

No Bluetooth LED floodlight

  • LED floodlight is not in reach found
  • Bluetooth is deactivated on smartphone

|

  • Check whether Bluetooth is activated on smartphone or reduce distance to the product
  • Re-start search

No connection being set up

  • Smartphone too close to device from smartphone to LEDfloodligh
  • Smartphone not compatible with app
  • App version not up to date

|

  • Distance to LED floodlight at least1.5 m
  • Use different smartphone
  • Update Smart Remote app in app store