Specifications
| L1 S| 255x110x120 mm
---|---|---
L11 S| 280x214x114 mm
L12 S/M| 272x155x108 mm
L15 S| 410x188x243 mm
L15 M| 404x188x243 mm
| | 230 V – 240 V, 50 Hz max. 60 W / E27
| | IP44| 2-2000 Lux
|
-20℃/+ ℃40
| |
L1 S
L11 S
L12 S
L15 S
|
8 sex.-35 mn
Principle (Sensor only):
Movement triggers lights, alarms and many other devices – for your convenience and safety. The integrated pyroelectric infrared detector senses the invisible heat radiated from moving objects (people, animals, etc.). The heat detected in this way is converted electronically into a signal that activates the light connected. Heat radiation is not detected through obstacles, such as walls or glass, and will therefore not activate the light.
Safety warnings
- During installation, the electrical wiring being connected must be dead. Therefore, switch off the power first and use a voltage tester to check that the power supply is disconnected.
- Installing this light involves work on the mains voltage supply. This work must therefore be carried out by a specialist in accordance with the applicable national wiring regulations and electrical operating conditions. (DE- VDE 0100, AT-ÖVE-ÖNORM E8001-1, CH-SEV 1000)
- Only use genuine replacement parts
- Do not dismantle the light yourself. It must only be repaired by a specialist workshop.
Installation
➊-➑
L = live conductor (usually black or brown), N = neutral conductor (usually
blue)
PE = any protective earth conductor (green/yellow)
➏ Connection, exposed wiring, ➐ Connection, concealed wiring
Attention: A mains switch for switching the light ON and OFF can of course be
installed in the mains lead.
Important: Reversing the connections may result in damage to the unit. Please
note that the light must be protected by a 10 A circuit breaker.
➎ The light arm must be engaged in the bracket to protect the internal wires
from strain.
Function
➒
Twilight setting (L 1 S / L 11 S / L 12 S / L 15 S factory setting:
daylight operation at 2000 lux):
The sensor’s response threshold can be infinitely varied from 2 – 2000 lux.
Control dial set to = daylight operation at approx. 2000 lux.
Control dial set to = night-time operation at approx. 2 lux.
To adjust the detection zone in daylight, the control dial must be set to
(daylight operation).
Time setting (L 1 S / L 11 S / L 12 S / L 15 S factory setting: 8 sec.):
Light ON time can be adjusted continuously from 8 sec. to 35 min.
Control dial set to – = shortest time (8 sec.).
Control dial set to + = longest time (35 min.)
When setting the detection zone, it is recommended to select the shortest
time.
Adjusting the detection zone L 1 S / L 11 S / L 12 S / L 15 S)
➓ using adhesive shrouds, for example, to mask out paths or neighbouring
premises reach can be adjusted as ⓫ required to between 2 and 10 m by tilting
the lens 90°.
Troubleshooting
(Fault / Cause ⇒ Remedy)
No power / Fuse faulty, not switched ON ⇒ new fuse, turn power switch ON,
check lead with voltage tester. Will not switch ON / Surroundings still too
bright ⇒ wait until response threshold is reached or adjust setting / Bulb
faulty ⇒ change bulb / Power switch OFF ⇒ switch on / Detection zone
not properly targeted ⇒ readjust. Will not switch OFF / Surroundings not
yet bright enough ⇒ wait until response threshold is reached or adjust
setting / Permanent movement in the detection zone ⇒ adjust detection
zone. Switches ON when unwanted / Detecting cars on the road, for example
⇒ Change detection zone, tilt sensor down. Reach changing / Differing
ambient temperatures ⇒ at low temperatures, shorten reach by tilting
sensor down; at high temperatures, tilt sensor up.
Disposal: Electrical and electronic equipment, accessories and packaging
must be recycled in an environmentally compatible manner.
Do not dispose of electrical and electronic equipment as domestic waste.
EU countries only: Under the current European Directive on Waste Electrical
and Electronic Equipment and its implementation in national law, electrical
and electronic equipment no longer suitable for use must be collected
separately and recycled in an environmentally compatible manner.
Manufacturer’s Warranty: This STEINEL product has been manufactured with
utmost care, tested for proper operation and safety in line with applicable
regulations and then subjected to random sample inspection. STEINEL guarantees
that it is in perfect condition and proper working order. The warranty period
is 36 months and starts on the date of sale to the consumer. We will remedy
defects caused by material flaws or manufacturing faults. The warranty will be
met by repair or replacement of defective parts at our own discretion. The
warranty shall not cover damage to wear parts, damage or defects caused by
improper treatment or maintenance. Further consequential damage to other
objects is excluded. Claims under the warranty shall only be accepted if the
product is sent fully assembled and well packed complete with a brief
description of the fault, a receipt or invoice (date of purchase and dealer’s
stamp) to the appropriate Service Centre.
Service: Please ask your nearest service centre how to proceed for
repairing faults not covered by the warranty or occurring after the warranty
expires.