INTRODUCTION
Thank you for choosing this Caple extractor hood. To ensure that you get the best results from your new extractor, we strongly suggest that you read this instruction manual thoroughly before use. If treated with care, your Caple extractor should give you years of trouble-free use. To register ownership, please follow the instructions on the guarantee card supplied with the appliance or visit www.caple.co.uk and register here. This instruction manual is designed to provide you with all the required information related to the installation, use and maintenance of the appliance. This hood is designed to extract unpleasant odours from the kitchen; it is not intended to extract steam. In order to operate the unit correctly and safely, please read this instruction manual carefully before installation and use. The cooker hood uses high quality materials and is made with a streamlined design. Equipped with an electric motor and centrifugal fan, it provides strong extraction with low noise. It also features non-stick grease filters and an easy installation.
IMPORTANT
This appliance must only be used for the purpose it is intended. Other types
of use are not permitted and may prove dangerous. Caple will not be held
liable for any damage caused by the incorrect use of the appliance. Do not use
any accessories or attachments not recommended by Caple as this may result in
fire, electric shock or injury. To protect against fire, electrical shock and
injury to persons, do not immerse cords or plugs in water or any other liquid.
Never touch the appliance with wet or damp hands. Never pull the power cable
as you could damage it. If the appliance is faulty, do not attempt to repair
it. Isolate it from the mains electric supply and contact Caple Service either
by phone 0117 938 7420 or email service@caple.co.uk
Keep all packaging (including plastic bags,
polystyrene foam etc) out of the reach and away from children. Do not rest
large or unstable objects on any part of the appliance.
IMPORTANT
Caple cannot be held responsible for injuries or losses caused by incorrect
use or installation of this product. Please note that Caple reserve the right
to invalidate the guarantee supplied with this product following incorrect
installation or misuse of the appliance. Under no circumstances should any
external covers be removed for servicing or maintenance except by suitabl
qualified personnel.
SAFETY INSTRUCTIONS
-
Never let children operate the machine.
-
The cooker hood is for home use only, not suitable for barbecuing, restaurants or other commercial purposes.
-
The cooker hood and its filter should be cleaned regularly in order to keep in good working condition.
-
Clean the cooker hood according to the instruction manual to reduce the risk of fire.
-
When using a gas hob, do not leave naked flames under the extractor.
-
Before connecting this appliance check that the power supply cord is not damaged.
-
If the room where the hood is to be used contains a fuel burning appliance such as a central heating boiler then its flue must be of the sealed or balanced flue type. If other types of flue or appliances are fitted ensure that there is an adequate supply of air to the room.
-
The air must not be discharged into a flue that is used for exhausting fumes from appliances burning gas or other fuels.
-
Regulations concerning the discharge of air have to be conformed to.
-
Do not flambé under the cooker hood.
-
Never leave frying pans unattended during use as over-heated fats and oils may catch fire.
-
To ensure the best performance, we recommend switching on the extractor 15 minutes before cooking and leave it running 15 minutes after. This will ensure that the air in the kitchen is being circulated before cooking commences and the air is being cleaned after cooking has finished.
-
The performance of your extractor will vary depending on a number of factors. These include type of extraction, room volume, length of ducting, ventilation available and the cleanliness of the filters.
-
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
-
Children should be supervised to ensure that they do not play with the appliance.
-
Cleaning and user maintenance must not be made by children without supervision.
-
Never immerse the appliance in water.
-
This appliance is intended to be used in household and similar applications such as:
- Staff kitchen areas in shops, offices and other working environments.
- Farm Houses.
- By clients in hotels, motels and other residential type environments.
- Bed and breakfast type environments.
-
To avoid all risk, if the power cable is damaged, it must only be replaced by a Caple appointed engineer.
-
Appliances can be used by persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the
hazards involved. -
Children must not play with this appliance.
-
When not in use and before cleaning, always isolate the appliance from the electrical supply.
ELECTRICAL SHOCK HAZARD
- Only plug this unit into a properly earthed outlet. If in doubt seek advice from a suitably qualified engineer.
- Failure to follow these instructions can result in death, fire, or electrical shock.
- This appliance must be connected to the mains by a competent person. We recommend that the appliance is connected by a qualified electrician who is a member of the N.I.C.E.I.C who will comply with the I.E.E and local regulations. Electrical information can be found on the rating plate.
INSTALLATION
PREPARE FOR THE INSTALLATION:
- If you have an outlet to the outside, your cooker hood can be connected as per the below picture by means of an extraction duct with an interior diameter of 150mm.
- Before installation, turn the unit off and unplug it from the outlet.
- The cooker hood should be installed so that there is a space of 650-760mm from the centre of the mesh grease filters to the hob (435-545mm from the bottom of the hood to the hob). It is the manufacturer of the hob who determines the clearance required and the clearance quoted by the hob manufacturer must be followed. In the absence of any instructions supplied with a gas hob, the minimum distance between the hob and the centre of the mesh grease filters must be at least 760mm
WARNING:
Observe the warning concerning the operation of the appliance when air is
discharged from the room. When the cooker hood and appliance supplied with
energy other than electricity are simultaneously in operation, the negative
pressure in the room must not exceed 4 Pa (4×10-5 Bar) Drill 3 x 8mm holes to
accommodate the bracket. Screw and tighten the bracket onto the wall with the
screws and screw plugs provided..
Level up the cooker hood and hang onto the wall bracket hook.
After hanging the hood on the bracket, remove the grease filters, mark 2 holes inside the hood for safety screws. After marking, remove the hood, drill two holes and insert 2 wall plugs and finally fix the safety screws with 2 screws (ST4x30mm).
Place the plastic duct on the cooker hood outlet
NOTE:
We recommend the ducting does not exceed 2.5 metres in length to ensure
maximum efficiency
CHIMNEY INSTALLATION
The lower chimney bracket is used to fix the upper decorative chimney and lower decorative chimney. Use 2pcs 4x8mm screws to attach lower chimney and lower chimney bracket together. Put the lower chimney on the cooker hood and mark the location of lower chimney bracket fixing holes on the wall.
NOTE:
Do not fasten screws much, make sure upper decorative chimney can be
telescopically adjusted once assembled.
Put the chimney on the cooker hood. Fix the lower chimney bracket on the wall by 2 screws (4mm x 30mm). Then pulling out the upper chimney upwards to the target height. Adjust to reach the height required. Fix the upper chimney on the upper chimney bracket by 2 screws (4x8mm). Then fix the upper chimney bracket on the wall. Before fixing the bracket on the wall, you can decide the upper chimney bracket fixing holes for installation. Finally, fix the lower chimney to the hood using 2 screws (4x8mm).
have an outlet to the outside, the exhaust pipe is not required (as shown in the section “Installation – ducted”), and charcoal filters must be installed
INSTALLING THE CHARCOAL FILTER (CAP61CF)
An activated charcoal filter can be used to trap odours. In order to
install the charcoal filter, the grease filter should be detached first. Press
the release button and pull it downward as shown below.
Fit the activated charcoal tilter onto the side of the motor and turn it in a clockwise direction to lock into place. Repeat the same on the other side. Scan the QR Code to access the ‘How To’ video.
NOTE:
Make sure the filter is securely locked. Otherwise, it may loosen and be
dangerous. When using a charcoal filter, the extraction power may be slightly
reduced. We recommend replacing these filters every 6 months. Replacement
filters (CAP61CF) can be purchased directly from
www.caple.co.uk
-
On/Off button
Press and hold for 2-3 seconds to turn the extractor fan on. You can then change the speeds as per below. Press again to switch off. -
Low Speed button
Is suitable for simmering and cooking which does not produce much steam or odour. -
Medium Speed button
Airflow speed is ideal for extracting with standard cooking. -
High Speed button
When a high amount of steam or odours are produced, use the high speed setting for the most effective extraction. -
Light button
Switches the light on and off
CARE AND MAINTENANCE
IMPORTANT:
Before cleaning or maintenance please switch off the electricity supply and
remove the plug from the wall.
REGULAR CLEANING
Use a soft damp cloth with lukewarm mildly soapy water or household
cleaning detergent. Never use metal pads, chemicals, abrasive material,
abrasive cleaning creams or stiff brushes to clean the appliance.
CLEANING THE GREASE FILTER
Clean the filter every month to help minimise the risk of fire. The filter
collects grease, smoke and dust, therefore the filter is directly affecting
the efficiency of the cooker hood. If not cleaned, the grease residue (which
is potentially flammable) will saturate the filter. It can be easily cleaned
with warm water and washing up liquid, alternatively the filters can be
cleaned in your dishwasher. Please ensure no other items are washed with the
filters, they must be washed separately to prevent food becoming trapped in
the gauze. Cleaning the grease filters in the dishwasher may lead to
discolouration, this is normal and is a not a fault with the product.
REPLACING YOUR CHARCOAL FILTER
This only applies if you are using the hood in recirculation mode (not vented
to the outside). The charcoal filter traps your cooking odours and they need
to be replaced, this can vary depending on how frequently the cooker hood is
used. We recommend replacing them at least every 6 months. This extractor uses
CAP61CF charcoal filters. Filters can be purchased directly from
www.caple.co.uk.
REPLACING THE BULB
NOTE:
The lights must be replaced by a qualified person.
- Switch the unit off and unplug the appliance.
- Push out and unclip the old LED light.
- Replace with the same type and rated bulb/lamp fixing. LED lamp (max.1.5W).
LIGHT SOURCE ENERGY CLA SS
This product contains a light source of energy efficiency class G.
TROUBLESHOOTING
FAU LT | CAUSE | SOLUTION |
---|
The lights on, but the fan does not work
| The fan blade is jammed.| Switch off the unit and contact Caple Service. To be repaired by qualified
service personnel only.
The motor is damaged.
The lights and fan do not work
| A blown fuse.| Replace the fuse.
The power cord is loose.| Plug in to the power supply again.
Serious vibration of the unit
|
The fan blade is damaged.
| Switch off the unit and contact Caple Service. To be repaired by qualified
service personnel only.
The fan motor is not fixed tightly.
| Switch off the unit and contact Caple Service. To be repaired by qualified
service personnel only.
The unit is not hung correctly on the bracket.| Take down the unit and check
whether the bracket is in the correct location.
The extraction performance is not good|
The filter requires cleaning.
| Clean the grease filter as directed in the ‘Care and maintenance’ section. Replace the charcoal filter (if in recirculation mode).
If the above table has not solved the problem please contact Caple Service by phone oN 0117 938 7420 or by email service@caple.co.uk