LOREX 393ACVRC ACVTR Transmitter Owner’s Manual

June 15, 2024
Lorex

LOREX logo

393ACVRC ACVTR Transmitter
Owner’s Manual

393ACVRC ACVTR Transmitter

LOREX 393ACVRC ACVTR Transmitter

Coaxial-to-Ethernet Converter
ACVRC & ACVTR Series
Quick Start Guide

Package Contents

LOREX 393ACVRC ACVTR Transmitter - feager

Safety Precautions

Please read the following safeguards and warnings carefully before using the product in order to avoid damages and losses:

  • Do not expose the device to lampblack, steam or dust. Otherwise, it may cause fire or electric shock.
  • Do not install the device at position exposed to sunlight or in high temperature. Temperature rise in device may cause fire.
  • Do not expose the device to humid environment. Otherwise, it may cause fire.
  • The device must be installed on solid and flat surface in order to guarantee safety under load and earthquake. Otherwise, it may cause device to fall off or turnover.
  • Do not place the device on carpet or quilt.
  • Do not block air vent of the device or ventilation around the device. Otherwise, temperature in device will rise and may cause fire.
  • Do not place any object on the device.
  • Do not disassemble the device without professional instruction.

Warnings

Do not use power line other than the one specified. Please use It properly. Otherwise, it may
cause fire or electric shock.

Disclaimers

  • This manual is for reference only
  • All the designs and software here are subject to change without prior written notice
  • All trademarks and registered trademarks are the properties of their respective owners
  • The function of the ITE being investigated to EN 62368-1 is considered not likely to require connection to an Ethernet network with outside plant routing, including campus environment
  • The installation instructions clearly state that the ITE is to be connected only to PoE networks without routing to the outside plant

Product Overview

Transmitter

LOREX 393ACVRC ACVTR Transmitter - Transmitter

Receiver

LOREX 393ACVRC ACVTR Transmitter - Receiver

Name Function
PoE OUT PoE output port
PoE IN PoE input port
Link BNC port Link indicator light

E100: On for 3 seconds, off for 1 second
E10: On for 1 second, off for 1 second
PWR| Power indicator light
Long Reach| Coaxial cable port

Setup

LOREX 393ACVRC ACVTR Transmitter - Setup

  • Performance and supported length are subject to transmission coaxial cable and coupler quality.
    ** Use a solid wire Cat5e/Cat6 network cable (not included)
    PoE Switch, NVR, camera, network cables and coaxial not included.

Mounting

Optional

The Coaxial-to-Ethernet Converter supports two installation modes: junction box or it can support DIN rail mount (not included). Refer to the junction box manual for installation instructions. Note: Supports slide width of 28mm (1.1”).

Supports slide width of 28mm (1.1”).

Product Description

The Coaxial-to-Ethernet Converter is a type of converter from RJ45 to BNC port, which supports long range power supply transmission via coaxial cable. It provides one BNC coaxial port and one RJ45 port. The product is equipped with  two transmission modes which are 100 Mbps and 10Mbps. It can be modified according to the transmission distance.
Features

  • Supports IEEE802.3, IEEE802.3u and IEEE802.3X standards.
  • Supports IEEE802.3af and IEEE802.3at power supply standards.
  • Port: 1 x RJ45 10/100Mbps, 1 x BNC.
  • Supports RG59 coaxial cable: 400m/1 OO Mbps, 1000m/10Mbps.
  • Supports MDI/MDIX self-adaption.
  • Supports long range power supply transmission via coaxial cable.
  • Operating temperature: -30-65°C.

PoE Power Supply Specifications (RG59 Coaxial Cable)

Cable Length (m)| Communication Bandwidth (Mbps)| PoE Max Load Capacity (W)| Network Operating Mode
---|---|---|---
100| 100| 21| E100
200| 100| 15| E100
300| 100| 11| E100
400| 100| 9| E100
500| 10| 7| E10
800| 10| 5| E10
1000| 10| 4| E10

ePoE switch supply voltage 48V. / RG-59, max. DC resistance < 5 Q / 100m (328 ft).
Caution: The load capacity can be applied to networking scheme 3. Cable length means the total wire length from switch to transmitter (including network cable and coaxial cable). It can use max. 2m network cable to connection transmitter to IPC.

Cable Length (m)| Communication Bandwidth (Mbps)| PoE Max Load Capacity (W)| Network Operating Mode
---|---|---|---
100| 100| 25.5| E100
200| 100| 24| E100
300| 100| 19| E100
400| 100| 16| E100
500| 10| 13| E10
800| 10| 8| E10
1000| 10| 6| E10

ePoE switch supply voltage 53V. / RG-59, max. DC resistance < 5 Q / 100m (328 ft).
Caution: The load capacity can be applied to networking scheme 3. Cable length means the total wire length from switch to transmitter (including network cable and coaxial cable). It can use max. 2m network cable to connection transmitter to IPC.

Need Help?
For up-to-date information and resources:

  1. Visit help.lorex.com
  2. Click on our product in the search results
  3. Click or your product in the search results
  4. Click on the Downloads tab

Register your product
Please see our full Terms of Service and Limited Hardware Warranty Policy at: lorex.com/warranty
Copyright © 2022 Lurex Technology Inc
As our products are subject to continuous improvement, Lurex reserves the right to modify product design, specifications and prices, without notice and without incurring any obligation. E&OE. All rights reserved.
** This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
Coaxial to Ethernet Converter for PoE Cameras**

LOREX 393ACVRC ACVTR Transmitter - feager1

This product is divided into the transmitter (ACVTR) and receiver (ACVRC). Designed to work as a type of converter from RJ45 to BNC port, which supports long-range power supply transmission via coaxial cable adding convenience to expand your network security system. It provides one BNC coaxial port and one RJ45 port. For a reliable connection, this is equipped with two transmission modes that are 100Mbps and 10Mbps. Stay connected and be able to modify the transmission distance.

  • Supports IEEE802.3, IEEE802.3u standards
  • Support data line (1, 2, 3, 6) PoE power supply
  • Port: 1RJ45 10/100Mbps, 1BNC
  • Supports RG59 coaxial cable: 400m/100Mbps,1000m/10Mbps
  • Supports MDI/MDIX self-adaption.
  • Supports long range power supply transmission via coaxial cable*

Specifications

Function Port
Power Consumption
Transmission
Bandwidth
PoE Protocol
Network Standard
Lightning Protection
Operating Temperature Operating Humidity
Weight
Dimension (W×D×H)| 110/100 Mbps Base-TX, 1BNC
<2W
RG59 coaxial cable:
400m/100Mbps, 1000m/10Mbps
48V Passive PoE (Pairs 1, 2+; 3, 6 Return)
IEEE802.3, IEEE802.3u, IEEE802.3x
Common Mode 4KV Differential Mode 2KV
–30°C to 65°C (–22°F to 149 °F )
5%–95%
61 g (0.13 lb)
79 mm × 52 mm × 23 mm
---|---

Model Information

ACVTR
ACVRC| Ethernet Over Coax Transmitter
Ethernet Over Coax Receiver| 6-95529-05059-1
6-95529-05060-7
---|---|---

Package Dimensions

Package
Package Weight
Package Dimensions
(W × D × H)
Package Cube| Plain Box
0.31 lb / 0.14 kg
4.5 × 3.1 × 3.0” /
115 × 80 × 78mm
0.02 lbf / 0.0007 dbm
---|---

Take RG59 as an example (Max. DC resistance < 5.0Ω/100m)

| ACVTR/ACVRC| Supports with 48V| Supports with 53V
---|---|---|---
100m
200m
300m
400m
500m
800m
1000m| Bandwidth (Mbps)
Load Capacity (W)
Bandwidth (Mbps)
Load Capacity (W)
Bandwidth (Mbps)
Load Capacity (W)
Bandwidth (Mbps)
Load Capacity (W)
Bandwidth (Mbps)
Load Capacity (W)
Bandwidth (Mbps)
Load Capacity (W)
Bandwidth (Mbps)
Load Capacity (W)| 100
21
100
15
100
11
100
9
10
7
10
5
10
4| 100
25.5
100
24
100
19
100
16
10
13
10
8
10
6

Diagram

LOREX 393ACVRC ACVTR Transmitter - Diagram

The number of ACVRC connected to the same switch cannot exceed 8.
*Performance and transmission speed are subject to coaxial cable quality and coupler quality.

Regulatory Information

The regulatory information herein might vary according to the model you purchased. Some information is only applicable for the country or region where the product is sold.
FCC Information
CAUTION
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
FCC conditions:
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
• This device may not cause harmful interference.
• This device must accept any interference received, including interference that may cause undesired operation.
FCC compliance:
This equipment has been tested and found to comply with the limits for a digital device, pursuant to part 15 of the FCC Rules. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in  accordance with the instructions, may cause harmful interference to radio communication.

  • For class A device, these limits are designed to provide reasonable protection against harmful interference in a commercial environment. Operation of this equipment in a residential area is likely to cause harmful interference in  which case the user will be required to correct the interference at his own expense.
  • For class B device, these limits are designed to provide reasonable protection against harmful interference in a residential installation. However, there is no guarantee that interference will not occur in a particular installation. If this  equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radiorrv technician for help.

Declaration of Conformity UKCA


This device complies with UKCA relevant directives and standards.
UK Declaration of Conformity (DoC) can be downloaded from: https://www.lorex.com/pages/ukca-compliance
Lurex Technology UK Limited
1 Georges Square, Bath Street, Bristol, United Kingdom, BS1 6BA.
Battery Replacement and Disposal
Applicable to products with battery.
CAUTION
Risk of explosion if battery is replaced by an incorrect type.
Dispose of used batteries according to the instructions.
Privacy Protection Notice
As the device user or data controller, you might collect personal data of others such as face, fingerprints, car plate number, Email address, phone number, GPS and so on. You need to be in compliance with the local privacy protection laws  and regulations to protect the legitimate rights and interests of other people by implementing measures include but not limited to: providing clear and visible identification to inform data subject the existence of surveillance area  and providing related contact For full FCC compliance declarations, visit https://www.lorex.com/pages/fcc-compliance

SCAN TO SEE QUICK START GUIDE.

         help.lorex.com/supportpage

LOREX.
Thank you for purchasing a Lurex product.
Warranty

Scan to see our full Terms of Service and Limited Hardware Warranty Policy.

lorex.com/warranty LOREX
logo

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals