KLARKTEKNIK DN9680 8 Port AES50 Extender and Multiplexer User Guide

June 5, 2024
KLARKTEKNIK

Quick Start GuideKLARKTEKNIK DN9680 8 Port AES50 Extender and
Multiplexer

DN9680
8 Port AES50 Extender and Multiplexer with up to 1000 Metre Range

**Important Safety

**

Instructions

CAUTION
RISK OF ELECTRIC SHOCK!
DO NOT OPEN!
Terminals marked with this symbol carry an electrical current of sufficient magnitude to constitute risk of electric shock.
Use only high-quality professional speaker cables with ¼” TS or twist-locking plugs pre-installed. All other installations or modifications should be performed only by qualified personnel.
This symbol, wherever it appears, alerts you to the presence of uninsulated dangerous voltage inside the enclosure – voltage that may be sufficient to constitute a risk of shock.
**** This symbol, wherever it appears, alerts you to important operating and maintenance instructions in the accompanying literature. Please read the manual.

Caution
To reduce the risk of electric shock, do not remove the top cover (or the rear section). No user-serviceable parts inside. Refer servicing to qualified personnel.
Caution
To reduce the risk of fire or electric shock,do not expose this appliance to rain and moisture. The apparatus shall not be exposed to drippingor splashing liquids and no objects filled with liquids, such as vases, shall be placed on the apparatus.
Caution
These service instructions are for use by qualified service personnel only.
To reduce the risk of electric shock do not perform any servicing other than that contained in the operation instructions. Repairs have to be performed by qualified service personnel.

  1. Read these instructions.
  2. Keep these instructions.
  3. Heed all warnings.
  4. Follow all instructions.
  5. Do not use this apparatus near water.
  6. Clean only with dry cloth.
  7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
  8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
  9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
  10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
  11. Use only attachments/accessories specified by the manufacturer.
  12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the  cart/apparatus combination to avoid injury from tip-over
  13.  Unplug this apparatus during lightning storms or when unused for long periods of time.
  14.  Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
  15.  The apparatus shall be connected to a MAINS socket outlet with a protective earthing connection.
  16. Where the MAINS plug or an appliance coupler is used as the disconnect device, the disconnect device shall remain readily operable.
  17. Correct disposal of this product: This symbol indicates that this product must not be disposed of with household waste, according to the WEEE Directive (2012/19/EU) and your national law. This product should be taken to a collection center licensed for the recycling of waste electrical and electronic equipment (EEE). The mishandling of this type of waste could have a possible negative impact on the environment and human health due to potentially hazardous substances that are generally associated with EEE. At the same time, your cooperation in the correct disposal of this product will contribute to the efficient use of natural resources. For more information about where you can take your waste equipment for recycling, please contact your local city office or your household waste collection service.
  18. Do not install in a confined space, such as a bookcase or similar unit.
  19. Do not place naked flame sources, such as lighted candles, on the apparatus.
  20.  Please keep the environmental aspects of battery disposal in mind. Batteries must be disposed of at a battery collection point.
  21. This apparatus may be used in tropical and moderate climates up to 45°C.

LEGAL DISCLAIMER

Music Tribe accepts no liability for any loss which may be suffered by any person who relies either wholly or in part upon any description, photograph, or statement contained herein. Technical specifications, appearances and other information are subject to change without notice. All trademarks are the property of their respective owners. Midas, Klark Teknik, Lab Gruppen, Lake, Tannoy, Turbosound, TC Electronic, TC Helicon, Behringer, Bugera, Oberheim, Auratone, Aston Microphones and Coolaudio are trademarks or registered trademarks of Music Tribe Global Brands Ltd. © Music Tribe Global Brands Ltd. 2021 All rights reserved.

LIMITED WARRANTY

For the applicable warranty terms and conditions and additional information regarding Music Tribe’s Limited Warranty, please see complete details online at musictribe.com/warranty.

DN9680 – ControlsKLARKTEKNIK DN9680 8 Port AES50 Extender and
Multiplexer - control palel

Controls

FRONT PANEL

  1. Four holes for rack mounting.

  2. Ventilation grill. Do not obstruct.

  3. Ethernet control status LED. Shows the current activity on the ETHERNET CONTROL port, where: off = not connected; on = connected, and flashing = active communications.

  4. Snake status LEDs. Show the status of the connected snake, where OK pulsates when the link is synchronized between router and endpoint, and ERROR illuminates to show no communications or a fault.

  5.  Shows the currently selected clock source, where: INTERNAL = the DN9680’s internally generated clock is used; EXTERNAL AES50 the DN9680 automatically searches the AES50 ports for the first valid clock; and EXTERNAL SNAKE = the clock on the snake connection is used.

  6. LCD display, which has 32 characters in a 16 x 2 configuration.

  7. Backlit KLARK TEKNIK roundel, which illuminates light blue to show that the unit is powered up.

  8.  Shows the currently selected snake type.

  9. AES50 audio status LEDs show the status of each AES50 port, where OK pulsates to show good communication and ERROR illuminates to show a communication error.
    REAR PANEL

  10. Ventilation grill. Do not obstruct.

  11.  Mains power inlet. This is a switch-mode power supply that has a mains IEC socket (11a), power on/off switch (11c) and a fuse drawer (11b) that houses an easily replaceable mains fuse.

  12.  Snake connectors for connecting the two DN9680s together via a single optical (12a) or Cat 5/5e (12b) snake.

  13.  Ethernet control port for connecting a PC/Mac for configuring the unit.

  14. Eight AES50 connectors.

  15.  Reset button for resetting the unit to its factory default condition.

Specifications

DN9680 General Specifications

Dimensions| 1U high (44.5 mm (1.75″)), 482.0 mm (19″) wide, 410.0 mm (16.1″) deep
Net weight| 4.9 kg
Shipping weight| 6.9 kg
Power consumption| 50 W
Power requirement| 110-240 V~, 50-60 Hz
Operating temperature range| +5°C to 45°C
Storage temperature range| -20°C to +60°C
Inputs and Outputs

Audio| 8 x AES50 etherCON ports with integral status LEDs
Snake (options)| 1 x copper snake (cable can be up to 100 m long)
1 x optical snake (cable can be up to 1000 m long)
Unit configuration port| 1 x Ethernet control port for RJ45 connector
Mains power inlet| 3-pin IEC connector

Other important information

Important information

  1. Register online. Please register your new Music Tribe equipment right after you purchase it by visiting musictribe.com. Registering your purchase using our simple online form helps us to process your repair claims more quickly and efficiently. Also, read the terms and conditions of our warranty, if applicable.
  2. Malfunction. Should your Music Tribe Authorized Reseller not be located in your vicinity, you may contact the Music Tribe Authorized Fulfiller for your country listed under “Support” at musictribe.com. Should your country not be listed, please check if your problem can be dealt with by our “Online Support” which may also be found under “Support” at musictribe.com. Alternatively, please submit an online warranty claim at musictribe.com BEFORE returning the product.
  3. Power Connections. Before plugging the unit into a power socket, please make sure you are using the correct mains voltage for your particular model. Faulty fuses must be replaced with fuses of the same type and rating without exception.

FEDERAL COMMUNICATIONS
COMMISSION COMPLIANCE
INFORMATION Klark Teknik DN9680

Responsible Party Name: Music Tribe Commercial NV Inc.
Address: 5270 Procyon Street, Las Vegas NV 89118,

United States
Phone Number:| +1 702 800 8290

DN9680
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
This equipment complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation.
Warning: Operation of this equipment in a residential environment could cause radio interference.
Hereby, Music Tribe declares that this product is in compliance with Directive 2014/35/EU,Directive 2014/30/EU, Directive 2011/65/EU and Amendment 2015/863/ EU, Directive 2012/19/EU, Regulation 519/2012 REACH SVHC and Directive 1907/2006/EC.
Full text of EU DoC is available at https://community.musictribe.com/ EU Representative: Music Tribe Brands DK A/S Address: Ib Spang Olsens Gade 17, DK – 8200 Aarhus N, Denmark

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

KLARKTEKNIK User Manuals