SUNSUN 50298 Pond Pump

Illustration similar, may vary depending on model

Read and follow the operating instructions and safety information before using it for the first time. Technical changes reserved!
Due to further developments, illustrations, functioning steps, and technical data can differ insignificantly.

Updating the documentation
If you have suggestions for improvement or have found any irregularities, please contact us.

The information contained in this document may alter at any time without previous notice. It is prohibited to copy or spread any parts of this document in any way without prior written allowance. All rights reserved.
The WilTec Wildanger Technik GmbH cannot be held accountable for any possible mistakes in this operating manual, nor in the diagrams and figures shown.
Even though the WilTec Wildanger Technik GmbH has undergone the biggest possible efforts to ensure that the operating manual is complete, faultless, and up to date, mistakes cannot be entirely avoided.
If you should find a mistake or wish to make a suggestion for improvement, we look forward to hearing from you.

Send an e-mail to: service@wiltec.info 
or use our contact form: https://www.wiltec.de/contacts/
The most recent version of this manual in various languages can be found in our online shop via: https://www.wiltec.de/docsearch

Our postal address is: WilTec Wildanger Technik GmbH
Königsbenden 12
52249 Eschweiler
Germany

Do you wish to pick goods up? Our pick-up address is: WilTec Wildanger Technik GmbH
Königsbenden 28
52249 Eschweiler
Germany

To shorten the waiting time and allow for a rapid on-site transaction, we ask you to call us previously or place your order via the webshop.
E-mail: service@wiltec.info
Tel: +49 2403 55592–0
Fax: +49 2403 55592–15

To return orders for exchange, repair, or other purposes, please use the following address. Attention!
To allow for smooth execution of your complaint or return, it is important to contact our customer service team before returning the goods.

Returns Department
WilTec Wildanger Technik GmbH
Königsbenden 28
52249 Eschweiler

E-mail: service@wiltec.info
Tel: +49 2403 55592–0
Fax: +49 2403 55592–15

Introduction

Thank you for purchasing this quality product. To minimize the risk of injury we urge that our clients take some basic safety precautions when using this device. Please read the operation instructions carefully and make sure you have understood its content. Keep these operation instructions safe.

Safety guideline

BEWARE:
The use of this device is allowed on standing water bodies, garden pond water or swimming ponds and their surrounding areas only with fault current protection switch with a  triggering nominal current up to 30 mA (according to VDE 0100 Article 702 and 738).

The device is not suitable for use in swimming pools, paddling pools, and other water bodies where somebody can be during operation. The operation of the device during the stay of people in the danger zone is not allowed. Ask your electrician.

The device is not intended for use by persons (including children) with impaired or limited physical, sensory, and mental abilities or lack of experience and/or real knowledge,  unless they are supervised by a person responsible for their safety or have obtained instructions by this person concerning the correct use of the device.
Children should be supervised to make sure that they do not play with the device.

ATTENTION:

  • Run a visual inspection of the device before every use. Do not use the device if the safety appliances are damaged or worn out. Never override safety regulations.

  • Use the device exclusively according to the intended purpose stated in the instructions for use.

  • You are responsible for the safety of the working environment.

  • If the cable or the plug is damaged due to external influences, the cable must not be repaired! It must be replaced with a new one. This work can be carried out only by an electrician.

  • The voltage of 230 V AC indicated on the device type plate must correspond to the existent mains voltage.

  • Never lift, carry, or suspend the device by using the power cable.

  • Make sure that the electrical plug connection is placed in a flood-proof area and is protected from moisture.

  • Before working on the pond pump, disconnect the appliance by pulling the plug out of the socket.

  • Avoid exposing the appliance to a direct water jet or rain.

  • The user is responsible for compliance with location-specific safety and installing regulations.
    Ask an electrician.

  • Consequential damage arising from flooded rooms caused by appliance dysfunctions must be avoided by means of appropriate measures (e.g., installing an alarm system, a  reserve pump).

  • In case of malfunction, the repair work only can be carried out by a qualified electrician.

  • The appliance must not run dry or with a completely closed intake.

  • The appliance must not be used for swimming pools.

  • The device cannot be employed for drinking water circuits.

WARNING:
Read carefully all the safety guidelines and the instructions.
Non-compliance with the safety rules and regulations can lead to an electric shock, fire, and/or serious injury. Keep the instructions and the safety guidelines in a safe place in  case you need them in the future.

Stability

  • The temperature of the liquid transported should not exceed +35 ℃ in permanent operation.
  • The transport of aggressive fluids (acids, bases, etc.) as well as of abrasive substances (e.g., sand) must be avoided.

Electrical connection

  • The electrical connection takes place via an electric safety socket 230 V ~ 50 Hz. Fuse protection at least 10 A.
  • The engine is protected against overloading or blocking by means of built-in motor protection. In case of overheating, the pump is turned off automatically due to the overheat protection, and after the cooling, the pump is automatically started.

Power connection

The pond pump is equipped with a safety plug. The device is designed for connection to an isolated ground receptacle with 230 V ~ 50 Hz. Make sure that the socket outlet is sufficiently fused (at least 6 A) and safe. Insert the plugin the socket outlet and the pond pump is ready for use.

Note:

Installation

The pump must be installed underwater. Make sure that moisture or water never reaches the main connection.

SUNSUN 50298 Pond Pump - Installation

The pump is to be installed as follows: in a fixed position with a fixed or flexible hose.

Use as a submerged pump (see Fig. 1)

  • Immerse the pump into the pond water, so that it is filled with water.
  • To avoid the premature clogging of the filter, position the pump above the pond sludge.
  • Install the supplied filter sponge to keep the pump inlet free.
  • The pump is started by plugging in the mains plug.

Operation

After reading the installation instructions carefully, you can start the new pump if you note the following aspects:

  • Connect the rubber feet with the motor body and filter basket.
  • Check if the pressure pipes have been installed properly.
  • Make sure that the electrical connection is 230 V ~ 50 Hz.
  • Check if the socket works properly.
  • Make sure that moisture or water never reaches the main connection.
  • Install the pump beneath the water surface.
  • Avoid that the pump operates dry.

Maintenance and cleaning

The pond motor pump is a maintenance-free and practice-proven quality product that was subjected to rigorous final inspections. Though, for long working life and continuous operation, we recommend regular checking and proper care. Proceed as follows:

  • Pull out the plug.
  • Turn the filter basket (Pump construction, 5) and the pump housing (3) to the left side (over 90°) and pull it away from the motor body. Now you can see the motor body.
  • Pull the impeller (2) out of the motor body.
  • Clean everything by using a sponge with water.
  • Re-introduce the rotor/impeller assembly (2) carefully into the motor housing/pump body (1).
  • Make sure that the rotor is properly placed and can rotate freely.
  • Connect the pump housing (3) to the filter basket (5) and place them onto the motor body (slanted leftwards more than 90°). Then turn it to the right and the pump is ready to use.

Overload protection

The pump has integrated overheat protection. After the pump is stopped it has to cool down for a while due to the overheat control device, before it runs again. In case it  does not run again by itself, the following checks shall be conducted:

Could the pump cool down sufficiently due to the overheat protection after having been stopped?

Is the water supply sufficient? > Improve the water supply!
Is the filter blocked? > If necessary, rinse the filter!
Is there dirt in the pump housing? > Perform cleaning!
Is the hose or the pipe blocked? > Clear the hose/pipe!
Is the hose broken, too long? > Check, replace, shorten!

Main components and installation

SUNSUN 50298 Pond Pump - components and installation

No Name No Name
1 Motor body 4 Rubber feet
2 Rotor/impeller 5 Filter basket
3 Pump housing

Technical specifications

Item num-
ber| Model| Power supply| Power (W)| Flow rate (%h)| Pump Pump  head (m)| (mm)
---|---|---|---|---|---|---
50258| CHJ-5oo| 230 V / 5o Hz| 7| 500| 0.9| 8ox45x6o
50299| CHJ-600| 8| 600| 1.| 73.5x61x86
50318| CHJ-l5oo| 25| 1,800| 2.| 1o5x55x90
50320| CHJ-2500| 45| 2,500| 10| ii5x66x131
50321| CHJ-3000| 55| 3,000| 3| 137x71x16g
50322| CHJ-4500| 65| 4,500| 4.| 157x89x191
50323| CHJ-5000| 8o| 5,000| 4.| 157x8gx1g1
50324| CHJ-6000| 100| 6,000| 4| 168x91x1g1

Disposal regulations

EU guidelines regarding the disposal of scrap electric appliances (WEEE, 2012/19/EU) were implemented in the law related to electrical and electronic equipment and appliances.
All WilTec electric devices that fall under the WEEE regulations are labeled with the crossed-out wheeled waste bin logo. This logo indicates that this electric equipment must not be disposed of with domestic waste.
The company WilTec Technik GmbH has been registered in the German registry EAR under the WEEEregistration number DE45283704.
Disposal of used electrical and electronic appliances (intended for use in the countries of the European Union and other European countries with a separate collection system for these appliances). The logo on the article or on its packaging points out that this article must not be treated as normal household waste but must be disposed to a recycling collection point for electronic and electrical waste equipment. By contributing to the correct disposal of this article you protect the environment and the health of your fellow men. Environment and health are threatened by inappropriate disposal.

Material recycling helps reduce the consumption of raw materials.
Additional information on recycling this article can be provided by your local community, municipal waste disposal facilities, or the store where you purchased the article.

Address:
WilTec Wildanger Technik GmbH
Königsbenden 12 / 28
D-52249 Eschweiler

Important notice:
The reprint or reproduction, even of excerpts, and any commercial use, even in part, of this instruction manual, require the written permission of WilTec Wildanger Technik  GmbH.

© by WilTec Wildanger Technik GmbH
http://www.WilTec.de
http://www.aoyue.eu
http://www.teichtip.de

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals