THT600 Advanced Thermal Camera User Manual
- June 15, 2024
- THT
Table of Contents
- THT600 Advanced Thermal Camera
- Technical Specifications
- Product Information
- Main Characteristics
- Applications
- Precautions and Safety Measures
- During Use
- After Use
- Preparation for Use
- Nomenclature
- Q: What is the model of the thermal camera?
- Q: What are the main characteristics of the instrument?
- Q: What are the applications of the digital thermal
- Q: How should I prepare the instrument for use?
THT600 Advanced Thermal Camera
Technical Specifications
- Model: THT500x
- Release: EN 1.00 – 17/05/2022
Product Information
The THT500x is a professional digital thermal camera designed
for infrared temperature measurements of objects. It provides
high-resolution images and is extremely flexible and easy to use.
The instrument has been designed in compliance with the directives
relevant to electronic measuring instruments.
Main Characteristics
- High-resolution images
- Flexible usage
- Easy to use
- Requires little maintenance
Applications
The digital thermal camera can be used for various applications
including:
- Infrared temperature measurements of objects
Product Usage Instructions
Precautions and Safety Measures
Before and after carrying out measurements, carefully observe
the following instructions:
- Switch off the instrument after use.
- If not using the instrument for a long period, remove the
battery.
During Use
Follow the instructions given in the manual to prevent damage to
the instrument or its components.
After Use
When measurement is complete, switch off the instrument. If you
expect not to use the instrument for a long period, remove the
battery.
Preparation for Use
Refer to the manual for instructions on preparing the instrument
for use.
Nomenclature
Refer to the manual for a detailed description of the
instrument’s nomenclature.
Description of the Instrument (Backside)
Refer to Fig. 1 in the manual for a visual representation of the
instrument’s backside and its corresponding nomenclature.
- Audio/Microphone, USB, micro SD, and HDMI
- LCD touch-screen display
- Function key (Image/video gallery)
- Function key LASER
- Function key (ON/OFF and Measuring Mode)
FAQ
Q: What is the model of the thermal camera?
A: The model of the thermal camera is THT500x.
Q: What are the main characteristics of the instrument?
A: The main characteristics of the instrument are
high-resolution images, flexible usage, easy to use, and requires
little maintenance.
Q: What are the applications of the digital thermal
camera?
A: The digital thermal camera can be used for infrared
temperature measurements of objects.
Q: How should I prepare the instrument for use?
A: Please refer to the manual for instructions on preparing the
instrument for use.
User man ual
THT 500x
THT 600x
©Copyright HT ITALIA 2022
Release EN 1.00 – 17/05/2022
©Copyright HT ITALIA 2022
Release EN 1.00 – 17/05/2022
THT500x – THT600x
TABLE OF CONTENTS 1. PRECAUTIONS AND SAFETY
MEASURES…………………………………………………………………….1
1.1. During use …………………………………………………………………………………………………………………………..3 1.2. After
use ……………………………………………………………………………………………………………………………..3 2. GENERAL
DESCRIPTION……………………………………………………………………………………………..3 3. PREPARATION FOR USE
……………………………………………………………………………………………..4 3.1. Initial checks
………………………………………………………………………………………………………………………..4 3.2. Instrument power supply
……………………………………………………………………………………………………….4 3.3. Storage
……………………………………………………………………………………………………………………………….4 4. NOMENCLATURE
………………………………………………………………………………………………………..5 4.1. Description of the
instrument………………………………………………………………………………………………….5 4.2. Description of function
keys …………………………………………………………………………………………………..9
4.2.1. Switching on the instrument …………………………………………………………………………………………………….9
4.2.2. Switching off the instrument……………………………………………………………………………………………………..9
4.2.3. Key LASER………………………………………………………………………………………………………………………….10 4.2.4. Key
10 4.2.5. Key T (Trigger)……………………………………………………………………………………………………………………..10
4.2.6. Key MENU/OK……………………………………………………………………………………………………………………..10 4.2.7. Key
10
5. USING THE INSTRUMENT ………………………………………………………………………………………….11 5.1.
Description of the main interface …………………………………………………………………………………………..11 5.2.
Image focusing …………………………………………………………………………………………………………………..12 5.3. Main menu
description ………………………………………………………………………………………………………..13
5.3.1. Settings Menu………………………………………………………………………………………………………………………14 5.3.1.1.
Menu “Device Settings” …………………………………………………………………………………………………………………….14
5.3.1.2. Menu “Measure settings”
…………………………………………………………………………………………………………………..20 5.3.1.3. Menu “Reset”
…………………………………………………………………………………………………………………………………..25
5.3.2. Measurement Menu………………………………………………………………………………………………………………27 5.3.3.
Menu Image, Distance measurement and Zoom ………………………………………………………………………30 5.3.4.
Menu Palette and isotherm lines’ functions ………………………………………………………………………………33
5.3.5. Menu Parameters …………………………………………………………………………………………………………………37 5.3.6.
Alarm menu …………………………………………………………………………………………………………………………40 5.4. Adjusting the
image temperature ………………………………………………………………………………………….41 5.5. Saving IR images
and videos ……………………………………………………………………………………………….43 5.5.1. Image saving
……………………………………………………………………………………………………………………….43 5.5.2. Recording IR videos
……………………………………………………………………………………………………………..44 5.5.3. Gallery menu
……………………………………………………………………………………………………………………….45 5.6. HDMI video
output………………………………………………………………………………………………………………46 5.7. Characteristics of the
lens ……………………………………………………………………………………………………46 5.8. Use of the Screening mode
………………………………………………………………………………………………….47
6. USING THE THTLINK SOFTWARE ………………………………………………………………………………48 6.1. Minimum
system requirements …………………………………………………………………………………………….48 6.2. Installing the
THTLink software …………………………………………………………………………………………….48 6.3. Main
characteristics of the THTLink software………………………………………………………………………….48
7. MAINTENANCE ………………………………………………………………………………………………………….49 7.1. General
information …………………………………………………………………………………………………………….49 7.2. Recharging the
internal battery …………………………………………………………………………………………….49 7.3. Cleaning the
instrument ………………………………………………………………………………………………………50 7.4. End of life
………………………………………………………………………………………………………………………….50 7.5. Accessories
……………………………………………………………………………………………………………………….50
7.5.1. Accessories provided ……………………………………………………………………………………………………………50
8. TECHNICAL SPECIFICATIONS ……………………………………………………………………………………51 8.1.
Environment ………………………………………………………………………………………………………………………53
8.1.1. Environmental conditions for use ……………………………………………………………………………………………53
9. ASSISTANCE……………………………………………………………………………………………………………..53 9.1. Warranty
conditions…………………………………………………………………………………………………………….53 9.2. Assistance
…………………………………………………………………………………………………………………………54
PRECAUTIONS AND SAFETY MEASURES
In the whole manual, the word “instrument” generically indicates THT500,
THT500H, THT600, THT600L and THT600H models unless otherwise indicated. The
instrument has been designed in compliance with the directives relevant to
electronic measuring
EN – 1
THT500x – THT600x
instruments. For your safety and to prevent damaging the instrument, please
carefully follow the procedures described in this manual and read all notes
preceded by symbol with the utmost attention. Before and after carrying out
the measurements, carefully observe the following instructions:
CAUTION
· Do not carry out any measurements in case gas, explosive materials or
flammables are present, or in humid or dusty environments
· Do not carry out any measurement in case you find anomalies in the
instrument such as deformation, breaks, substance leaks, absence of display on
the screen, etc
· Keep the instrument steady during any measuring operation · Do not use the
instrument in environments with temperatures
exceeding the operating and storage limits specified in § 8.1.1 in order not
to damage it · Only the accessories provided together with the instrument will
guarantee safety standards. They must be used only if in good conditions and
replaced with identical models, when necessary · Check that the battery is
correctly inserted · Check that the LCD display gives indications consistent
with the function selected · Do not direct the instrument at very high
intensity radiation sources (e.g. the sun) in order to prevent damaging the IR
sensor · Prevent hits or strong vibrations in order to keep the instrument
from damage · When bringing the instrument from a cold to a hot environment,
leave it on long enough for condensation water to evaporate
In this manual, and on the instrument, the following symbols are used:
Warning: observe the instructions given in this manual; improper use could
damage the instrument or its components.
This symbol on the display means that the instrument is able to emit a laser
pointer in Class 2. Do not direct the radiation towards the eyes in order to
prevent injury.
EN – 2
THT500x – THT600x
1. DURING USE
CAUTION
· Failure to comply with the caution notes and/or instructions may damage the
instrument or be a source of danger for the operator.
· Use the instrument only in the temperature ranges indicated in § 8.1.1.
2. AFTER USE When measurement is complete, switch off the instrument. If you
expect not to use the instrument for a long period, remove the battery.
2. GENERAL DESCRIPTION
The instrument is a professional digital thermal camera capable of carrying
out infrared temperature measurements of objects and providing high-resolution
images in an extremely flexible way. It is also very easy to use and needs
little maintenance.
The main characteristics of the instrument are:
· Infrared temperature ranging from -20°C to 650°C (THT500, THT600, THT600L) ·
Infrared temperature ranging from -20°C to 1200°C (THT500H, THT600H) · Built-
in photo camera for a visible image · PiP Fusion and Auto Fusion (AUF)
function · Cursor in a fixed central position · Cursors for automatic
detection of “hot” and “cold” spots of the image · TFT colour display with
capacitive touch-screen · Alarm conditions on temperature measurement · 8
colour palettes available · Electronic zoom x1-x32 · Advanced analyses (Spots,
Lines, Areas, Isotherm lines) · Automatic detection of hot/cold spots of the
image · “Screening” function for a quick measurement of surface temperature ·
Storage of JPG images on external micro-SD card and in the internal memory ·
IR sensor resolution: 384x288pxl (THT600, THT600L, THT600H) · IR sensor
resolution: 160x120pxl (THT500, THT500H) · USB port for PC connection and
image and video transfer · Voice and text annotation on saved images · IR
MPEG4 video recording on micro SD card and in the internal memory · HDMI video
output · Built-in laser pointer and illuminator · Measurement of the distance
from target with laser pointer · Rechargeable Li-ION battery · Analysis and
creation of reports with the provided dedicated software · WiFi interface to
mobile devices through the APP HTProCamera
The applications of the digital thermal camera are:
· Predictive and preventive maintenance of electrical and mechanical
appliances · Monitoring of the temperature of working processes · Maintenance
and troubleshooting on forced ventilation ducts · Domestic/industrial use in
troubleshooting room insulation problems
EN – 3
· Applications in the construction field · Safety problems
THT500x – THT600x
3. PREPARATION FOR USE
3.1. INITIAL CHECKS Before shipping, the instrument has been checked from an
electric as well as mechanical point of view. All possible precautions have
been taken so that it is delivered undamaged. However, we recommend generally
checking the instrument in order to detect possible damage suffered during
transport. In case anomalies are found, immediately contact the forwarding
agent. We also recommend checking that the packaging contains all components
indicated in § 7.5. In case of discrepancy, please contact the Dealer. In case
the instrument should be returned, please follow the instructions given in §
9.
3.2. INSTRUMENT POWER SUPPLY The instrument is supplied by a 1×3.7V, 5200mAh
rechargeable Li-ION battery and AC mains power supply, which also provides for
the recharge of the mentioned battery. Both of these systems are provided
together with the instrument. For battery recharge, please refer to § 7.2.
3.3. STORAGE In order to guarantee precise measurement, after a long storage
time under extreme environmental conditions, wait for the instrument to come
back to normal operating conditions (see § 8.1.1).
EN – 4
4. NOMENCLATURE
4.1. DESCRIPTION OF THE INSTRUMENT
THT500x – THT600x
CAPTION:
Fig. 1: Description of the instrument’s backside
1 Audio/Microphone, USB, micro SD and HDMI
2 LCD touch-screen display
3 Function key (Image/video gallery)
4 Function key LASER
5 Function key
(ON/OFF and Measuring Mode)
6 Pins for strap belt fixing
7 Function key MENU/OK and arrow keys ,,,
8 Rechargeable battery
EN – 5
THT500x – THT600x
CAPTION:
Fig. 2: Description of the instruments front side
1 Built-in white LED illuminator 2 Laser pointer 3 Laser pointer for distance measurement 4 Photo camera 5 IR sensor 6 Slot for inserting lens protection cap 7 Trigger key (T) 8 Slots for the passage of the strap belt fixing 9 Rechargeable battery
EN – 6
THT500x – THT600x
CAPTION
Fig. 3: Description of the lateral part of the instrument
1 Lens associated to IR sensor 2 Trigger key (T) 3 Strap belt
EN – 7
THT500x – THT600x
CAPTION
Fig. 4: Description of upper and lower parts of the instrument
1 Lens associated to IR sensor 2 Headphone/microphone input 3 HDMI video output 4 Slot for micro-SD card insertion 5 Micro USB port 6 Threaded hole (¼”) for tripod insertion
EN – 8
THT500x – THT600x
4.2. DESCRIPTION OF FUNCTION KEYS The instrument has 8 function keys described further in this text and a trigger key “T” with multiple functions.
4.2.1. Switching on the instrument
1. Press and hold key
for 2s to switch on the instrument. After the initial splash
screen is displayed (see Fig. 5 left side), the instrument needs for a certain heating
time (approx. 30s) in order to provide accurate temperature measurements and quality
images.
2. The instrument initially shows the visible image for a few seconds and the message “IR
calibration…” while it correctly calibrates the internal sensor (see Fig. 5 middle).
3. After a few seconds, the IR image is shown on the display and the instrument is ready
for measurement (see Fig. 5 right side).
Fig. 5: Sequence upon switching on the instrument
CAUTION
· The sound that accompanies the message “IR calibration…” is a
necessary condition for the instrument’s internal calibration.
· Pressing the
key allows switching on/off the instrument. The
instrument also has an Auto-Power-Off function with selectable time.
4.2.2. Switching off the instrument
1. Press and hold key
for at least 4s to switch off the instrument. The following
screen appears on the display.
Fig. 6: Switching off the instrument
2. Touch the virtual button “OK” to switch off the instrument. EN – 9
THT500x – THT600x
3. Touch the virtual button “Cancel” to cancel the operation and go back to normal display.
4. By pressing and holding the key
for at least 7s, the instrument is directly switched
off.
4.2.3. Key LASER
Press key LASER to switch on/off the instrument’s laser pointer. The symbol ” ” is found
in the top part of the display. Press and hold key LASER to manually calibrate the
instrument. The “IR calibration…” message appears for an instant on the display
4.2.4. Key Press key to enter the gallery of images/videos saved in the internal memory or on the inserted micro SD card (see § 5.5.3).
4.2.5. Key T (Trigger) Pressing the T key found on the front part of the instrument allows freezing the IR image on the display and automatically opens the section for saving the image (see § 5.5.1). Press the T key again to save the image on the display or touch the display to return to normal viewing.
4.2.6. Key MENU/OK Pressing the key MENU/OK allows displaying/hiding the instrument’s main menu (see § 5.3). The operation is always possible also by touching the display.
4.2.7. Key
Long pressing key
allows switching on/off the instrument (see § 4.2.1 and § 4.2.2).
With the instrument switched on, by pressing key
several times, it is possible to
select the image temperature adjusting modes (see § 5.4).
EN – 10
THT500x – THT600x
5. USING THE INSTRUMENT
5.1. DESCRIPTION OF THE MAIN INTERFACE The instrument shows the following
interface on the display:
CAPTION
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Fig. 7: Main instrument interface
Measuring unit of temperature (°C, °F, K) Measuring unit of distance (m, Ft)
Set emissivity value Active zoom indication Number of detections statistically
valid in Face Mode (see § 5.3.2) Indication of laser pointer activation
Presence of micro SD card in the instrument Active WiFi connection Battery
charge level System time Main instrument menu Detection of the person’s face
and maximum measured temperature Maximum temperature associated to the image
on the display Set color palette Minimum temperature associated to the image
on the display Indication of the selected adjustment mode (Manual, Auto, HG)
EN – 11
THT500x – THT600x
5.2. IMAGE FOCUSING Focusing the IR image found on the instrument display must
be performed manually by rotating the lens installed on the IR sensor (see
Fig. 1 Part 3). Keep the instrument steady while performing this operation.
CAUTION
· Always focus the image before saving it, in order to perform correct
temperature measurements of the framed target.
· The IR image on the display may be out of focus after a few minutes or if a
new object is framed. In order to solve this problem, the instrument performs
its internal calibration and makes a sound which must be considered as fully
normal.
Fig. 8: Focusing the image on the display The correct focusing of the image
allo ws for the whole of the infrared energy irradiated by the target to be
directed at the pixels of the IR sensor. Without focusing, the thermal image
may be out of focus and the indicated radiometric data will be inaccurate.
EN – 12
THT500x – THT600x
5.3. MAIN MENU DESCRIPTION By pressing the key MENU/OK or by simply touching
the display, the instrument shows/ hides the following main menu on the
display. Use the touch-screen or the arrow keys to select menu items.
Fig. 9: Main instrument menu
The following options are available:
Menu Alarm allows setting the alarm thresholds on the temperature measurements
associated with the items inserted onto the image (cursor, dots, lines and
areas).
Menu Parameters defines the values of the correction parameters used for
temperature measurement.
Menu Measurement allows inserting items (dots, lines, areas) onto the image with the relevant associated temperature values.
Menu Image allows selecting the display mode of the framed target as regards thermal image, visible image and combinations thereof. In the same section it is also possible to use the function for measuring the distance from target.
Menu Palette
allows selecting the available colour palettes and setting the
visible alarm conditions according to the measured temperature.
Menu Settings allows setting system parameters, the type of measurement, the values of the compensation parameters and the reset of the instrument.
EN – 13
THT500x – THT600x
5.3.1. Settings Menu By touching the icon , the instrument enters the
“Settings” menu, in which it is possible to define the values of system
parameters, the settings of measurements and the reset of the instrument. The
following screen appears on the display:
Fig. 10: Section Setting of the general menu
5.3.1.1. Menu “Device Settings” In this section (see Fig. 11) it is possible
to define the instrument’s system parameters. Touch the screen to
activate/deactivate the desired options.
USB mode
Fig. 11: Instrument settings
1. Touch the item “USB mode”. The following screen appears on the instrument’s display:
EN – 14
THT500x – THT600x
Fig. 12: USB mode 2. Touch the option “PC Connection” to make the instrument
communicate with the PC. 3. Connect the instrument to the PC via the provided
USB cable. The screen in Fig. 13
left side appears on the display:
Fig. 13: Connecting the instrument to the PC 4. Confirm with “OK” to activate
the connection, or touch “Cancel” to go back to the main
menu. The screen in Fig. 13 right side appears on the display, and the
instrument does not accept any command. 5. The instrument is detected by the
PC like a “Removable disk” and it will be possible to download the IR
images/videos found in the internal memory or on the inserted micro SD card.
6. Disconnect the USB cable from the instrument in order to restore normal
operation. 7. Select option “PC Camera” to allow displaying on the PC in real
time the image shown on the display. Within “My Computer”, search for the “USB
video device” which is automatically recognized by the PC and allows showing
the (IR or visible) image found on the display in real time. Re-boot the
instrument to make active the function White LED illuminator 1. Touch the item
“Flashlight” to activate/deactivate the instrument’s built-in white LED
illuminator (see Fig. 2 part 1) . The following screen appears on the
display:
EN – 15
THT500x – THT600x
Fig. 14: Activation of the illuminator
2. Touch the icon ” illuminator.
” to activate the illuminator, or icon ”
” to deactivate the
Display brightness
1. Touch the item “Brightness” to adjust display brightness. The following
screen appears on the display:
Fig. 15: Adjusting display brightness 2. Touch and drag the white bar to
adjust brightness, observing the display as you do so. Laser pointer
activation 1. Touch the item “Laser” to activate/deactivate the laser pointer
(see Fig. 2 part 2). The
following screen appears on the display:
EN – 16
THT500x – THT600x
2. Touch the icon ”
Fig. 16: Laser pointer activation ” to activate the pointer, or icon ” ” to deactivate the pointer.
Activation of WiFi connection 1. Touch the item “WiFi” to enter the section
for the activation/deactivation and
customization of the instrument’s WiFi connection. The screen in Fig. 17
right side appears on the display.
CAUTION
WiFi connection only allows carrying out the instrument’s connection to mobile
devices (Android/iOS) through the dedicated APP HTPr C
EN – 17
THT500x – THT600x Fig. 17: Activation of WiFi connection 2. Touch the icon ” ”
to activate WiFi connection, or icon ” ” to deactivate WiFi connection. The
icon ” ” is shown on the display 3. Touch item “SSID” to define a custom
identification ID of the WiFi connection (default THT500). The screen in Fig.
18 left side appears on the display.
Fig. 18: Definition of SSID and Password of the WiFi connection 4. Define the
desired name of the SSID and touch the icon ” ” to confirm, or icon “X” to
quit without changes. 5. Touch item “Password” to define a custom Password for
the WiFi connection (default
“12345678”). The screen in Fig. 18 right side appears on the display. 6.
Define the desired Password (max 8 digits) and touch the icon ” ” to confirm,
or icon
“X” to quit without changes.
Date/Time setting 1. Touch the item “Date/Time” to set the system’s Date/Time.
The screen in Fig. 19 right
side appears on the display:
Fig. 19: System date/time setting
EN – 18
THT500x – THT600x 2. Touch the arrows ” ” or ” ” to perform setting. Options
“AM” and “PM” indicate the
time in a (0-12h) format, whole option “24Hr” indicates format (0-24h). Touch
“Set Date” to confirm, or “Cancel” to quit without changes. Language setting
- Touch the item “Language” to set the system’s Language. The screen in Fig.
20 right side appears on the display:
Fig. 20: System language setting 2. Select the desired language by scrolling down the list with the arrow key ” ” and quit
the section by touching the arrow key ” ” to confirm setting.
Auto power off setting 1. Touch item “Auto Power Off” to set the instrument’s auto power off time. The screen in
Fig. 21 right side appears on the display:
Fig. 21: Auto power off setting EN – 19
THT500x – THT600x
2. Select one of the options: “OFF” (deactivation), 5MIn, 10Min, 15Min or
30Min and touch the arrow key ” ” to quit and confirm setting.
Information on the instrument
1. Touch the item “About” to display the information about the instrument ad
regards: model, serial number, internal Firmware version and available
residual memory. The screen in Fig. 22 right side appears on the display:
Fig. 22: Information on the instrument 2. Touch the arrow key ” ” to quit and confirm.
5.3.1.2. Menu “Measure settings” In this section (see Fig. 23), it is possible to define the type of measurement, the values of the compensation parameters and the settings of the alarm conditions. Touch the screen to activate/deactivate the desired options.
Thermometer section
Fig. 23: Menu “Measure settings” EN – 20
THT500x – THT600x In this section it is possible to define the following
temperature measuring modes: Normal mode the instrument measures the surface
temperature of any object
(according to its emissivity) in the range: -20°C ÷ 150°C / 0°C ÷ 650°C
(THT500, THT600, THT600L) or -20°C ÷ 150°C / 0°C ÷ 1200°C (THT500H, THT600H)
with accuracy ±2°C/±2%reading Screening mode the instrument measures the
temperature of parts of the human body in the range: 32.0°C ÷ 42.0°C with
accuracy ±0.5°C. This mode is also used to evaluate whether a person has a
fever or not (see § 5.8). 1. Touch the item “Thermometer”. The screen in Fig.
24 right side appears on the display:
Fig. 24: Menu Thermometer 2. Touch one of the options “Normal mode” or
“Screening Mode” and the arrow key ” ” to
quit and confirm setting.
Setting the distance measuring unit 1. Touch the item “Distance unit” to set
the measuring unit of distance. The screen in Fig.
25 right side appears on the display:
EN – 21
THT500x – THT600x
Fig. 25: Menu Setting the distance measuring unit 2. Touch one of the options
“m” (meters) or “Ft” (feet) and the arrow key ” ” to quit and
confirm setting. Setting the temperature measuring unit 1. Touch the item
“Temperature unit” to set the measuring unit of temperature. The screen
in Fig. 26 right side appears on the display:
Fig. 26: Menu Setting the temperature measuring unit 2. Touch one of the
options “°C” (Celsius), “°F” (Fahrenheit), “K” (Kelvin) and the arrow
key ” ” to quit and confirm setting.
Setting of temperature range 1. Touch the item “Temperature range” to set the
instrument’s measuring range of
temperature (This option is relevant to the relevant to the Normal measuring
mode). The screen in Fig. 27 right side appears on the display:
EN – 22
THT500x – THT600x
Fig. 27: Menu Setting the temperature measuring range
2. Touch one of the options “-20÷150°C” or “0÷650°C” and the arrow key ” ” to
quit and confirm.
Setting Emissivity of the material
1. Touch item “Emissivity” to set the emissivity values of the item whose
temperature needs to be measured. In order to carry out accurate temperature
measurements, it is important to define the correct value of this parameter,
which represents the ability of a body to emit infrared radiation, according
to the kind of material the measured object is made of. Table 1 shows the
emissivity values for the most common materials. Emissivity takes values
between 0 (mirror or perfectly reflecting surface) and 1 (perfectly radiating
blackbody). Most of the painted or oxydized surfaces have an emissivity value
of approximately 0.95.
Material
Water
0.96
Stainless steel
0.14
Aluminium foil
0.09
Asphalt
0.96
Cement
0.97
Cast iron
0.81
Rubber
0.95
Wood
0.85
Bricks
0.75
Tape
0.96
Brass foil
0.06
Human skin
0.98
PVC plastic
0.93
Polycarbonate
0.80
Oxydized Copper
0.73
EN – 23
THT500x – THT600x
Rust
0.80
Paint
0.90
Earth
0.93
Table 1: Emissivity values of typical materials
Fig. 28: Emissivity setting menu
2. Touch one of the items corresponding to the type of material and the arrow
key ” ” to quit and confirm. To customize the emissivity value, see § 5.3.5.
Setting Alarm mode 1. Touch the item “Alarm mode” to activate the acoustic
alarm thresholds on temperature
measurement associated to the objects inserted onto the image (cursor, dots,
lines and areas) associated to the “Alarm” function in the main menu (see §
5.3). The screen in Fig. 29 right side appears on the display:
Fig. 29: Menu for Activation of alarm thresholds on measurements
2. Touch one of the following options: OFF (alarm deactivated), Above MAX
alarm (active alarm for measured values exceeding the set threshold), Below
MIN alarm (active alarm for measured values lower than the set threshold),
Interval alarm (active alarm for measured values within the range between the
set minimum and maximum thresholds).
3. Touch the arrow key ” ” to quit and confirm.
EN – 24
THT500x – THT600x
Section Image Align In this section it is possible to align the IR image to
the visible one shown on the display. These images could not be aligned due to
the different position of the IR sensor and of the internal photo camera on
the instrument.
Fig. 30: Alignment of the image on the display 1. Touch the item “Image
Align”. Fig. 30 middle is shown on the display. In this figure,
the two images with a low infrared value are overlapping. 2. Touch the 4
arrows on the display in order to move the IR image by overlapping it onto
the visible one (see Fig. 30 right side). 3. Touch the icon ” ” to confirm
or icon “X” to quit without changes. 5.3.1.3. Menu “Reset” In this section, it
is possible to delete the content of the internal memory or of the inserted
micro SD card and restore the instrument’s default conditions. Touch the
screen to activate/deactivate the desired options.
Fig. 31: Instrument reset menu 1. Touch the item “Reset”. The screen in Fig.
31 right side appears on the display. Touch
the item “Delete memory”. The following confirmation screen is displayed: EN –
25
THT500x – THT600x
Fig. 32: Confirm memory deletion
2. Touch the option “Yes” to confirm deletion, or option “No” to cancel the
operation and go back to the previous screen.
3. Touch the item “Default settings”. The following confirmation screen is
displayed:
Fig. 33: Default settings
4. Touch the option “Yes” to confirm deletion, or option “No” to cancel the
operation and go back to the previous screen. The default conditions of the
instrument are reported in the following
Menu Measurement
Measuring parameters
Image
Parameter Central measuring cursor
Cursor “hot” spot Cursor “cold” spot
Emissivity Reflected temperature
Mode Palette Image adjustment Language
EN – 26
Value OFF OFF OFF 0.95 25°C IR Iron Auto English
System settings
pointer Illuminator Table 2: Parameters’ default values
THT500x – THT600x
OFF OFF
5.3.2. Measurement Menu Within this menu, it is possible to enable/disable
different objects on the image, in order to prepare an advanced analysis of
the temperature measurement. The instrument is provided with:
1 fixed cursor in a central position Max 3 spots, which can be freely placed
onto the image 2 cursors for the detection of “hot” and “cold” spots of the
image Max 3 dynamic measuring areas Max 2 dynamic horizontal and vertical
lines Face mode to detect face temperature
1. Touch the screen or press key MENU/OK to enter the main menu.
2. Touch the icon ” ” to enter the “Measurement” menu. The following screen
appears on the display:
Fig. 34: Measurement Menu 3. The following functions can be mutually used
(each one excludes the other):
Central spot Touch the icon ” ” to activate the cursor in
a fixed central position on the display. The temperature associated with the
central cursor is shown in the top left-hand part of the display. Touch the
icon ” ” to remove the central cursor.
EN – 27
THT500x – THT600x
3 mobile cursors Touch the icon ” ” to activate the mobile
cursor P1 which can be freely dragged on the display. Touch the icon
repeatedly to activate the other mobile cursors indicated as P2 and P3. The
temperatures associated with the mobile cursors is shown in the top left-hand
part of the display. Touch the icon ” ” to remove the cursors.
Cursors for “hot” and “cold” spots Touch the icon ” ” to activate the dynamic
cursors indicating the “hottest” (red) and “coldest” (blue) spots of the
image. The temperatures associated with the dynamic cursors (Hi and Lo) is
shown in the top left-hand part of the display. Touch the icon ” ” to remove
the cursors.
Area Cursors Touch the icon ” ” to activate the mobile
cursor A1 indicating a closed area, which can be freely modified and dragged
on the display. Touch the icon repeatedly to activate the other mobile cursors
indicated as A2 and A3. The temperatures MIN, MAX, AVG (average) of the spots
inside the area are shown in the top left-hand part of the display. Touch the
icon ” ” to remove the cursors.
Line Cursors
EN – 28
THT500x – THT600x
Touch the icon ” ” to activate the horizontal line mobile cursor which can be
freely dragged on the display. Touch the icon a second time to activate the
vertical line cursor. The display shows the dynamic trend of temperature.
The temperatures MIN, MAX, AVG (average) of the spots on the line are shown in
the top left-hand part of the display.
Face mode Touch the icon ” ” to activate the “Face
mode”, which allows measuring the maximum face temperature of a person who
must be framed within the area shown on the display. The face area
automatically becomes rectangular as shown in Fig. 35. Touch the icon ” ” to
remove the cursor.
Fig. 35: Indication of Face mode
4. The Face mode is linked to the setting of the alarm condition above
threshold (see § 5.3.1.2) and to the value of the maximum threshold set (see §
5.3.6).
5. If the face temperature of the framed person is lower than the set
threshold, it will be shown green in the top part o the shown area (see Fig.
35 middle).
6. If the face temperature of the framed person is higher than the set
threshold, it will be shown red in the top part o the shown area (see Fig. 35
right side).
7. The Face mode allows for the face temperature of several people (up to 10
people) to be evaluated at the same time (see Fig. 36). The counter ” ” found
at the top of the display indicates the number of statistically valid
detections.
EN – 29
THT500x – THT600x
Fig. 36: Face mode on more people
5.3.3. Menu Image, Distance measurement and Zoom In this menu it is possible
to select the type of image displayed, to measure the distance between the
instrument and the framed target and to zoom in and out the image. The
following options are available: Thermal Display of the IR image only Visible
Display of the visible image only Fusion Display of the IR image within the
visible image (PiP feature) Visible and Thermal Display IR and visible image
divided into half the screen Auto Fusion In this display mode, the instrument
automatically mixes the infrared
and the visible part of the image Distance measurement from the framed target
it is possible to carry out this
operation by means of the laser pointer Zoom it is possible to activate an
electronic zoom x1 ÷ x32 1. Touch the screen or press key MENU/OK to enter the
main menu. 2. Touch the icon ” ” to enter the “Image” menu. The following
screen appears on the
display:
EN – 30
THT500x – THT600x
Fig. 37: Image menu 3. The following options can be selected:
Thermal image Touch the icon ” ” to display the IR thermal image
Fusion image (Picture in Picture) Touch the icon ” ” to display the Fusion
image (IR within the visible image). Use the arrow keys or or touch the
arrow icons found in the “Fusion” box to adjust the IR level percentage Drag
the IR frame into the visible image for a possible alignment.
Visible & Thermal image EN – 31
THT500x – THT600x Touch the icon ” ” to display the thermal
and visible image at the same time. The two images are shown on the screen
divided into two halves.
Visible image Touch the icon ” ” to display the visible image.
AUF image (Auto Fusion) Touch the icon ” ” to display the image in
“Auto Fusion” mode. In this display mode, the instrument
compares the temperature in the middle of the display with the temperatures of
the whole framed image, in order to automatically determine the mix between
the infrared and the visible part. This function allows producing clearer
printouts of the saved image.
4. Touch the icon ” ” to activate the measurement of the distance between the
instrument and the framed target. The sequence of screens appears on the
display are shown in Fig. 38
EN – 32
THT500x – THT600x Fig. 38: Function for measuring distance with laser pointer
5. The laser pointer (see Fig. 2 – part 3) turns on and blinks intermittently.
The distance measurement is always active on the instrument and the result is
shown in the upper central part of the display (see Fig. 38 – right part).
Move the instrument to the positions where you want to take the measurement 6.
Press key Trigger (T) to freeze the image and save it in the instrument’s
memory (see § 4.2.5)
CAUTION
Distance measurement is NOT possible if the surface of the framed target is
made of a reflecting material (e.g.: glass, Plexiglas, aluminium, etc.)
7. Touch the icon ” ” to activate the electronic Zoom of the image. The
following screen appears on the display.
Fig. 39: Activating image zoom 8. Press the arrow keys or or touch the scroll
bar to increase/decrease the zoom
level in the range 1.0x ÷ 32.0x by steps of 0.1x and observe the result on the
display. The zoom value is shown at the top of the display (see Fig. 7 part
4). 9. Set the value back to 1.0 to go back to the original size of the image.
CAUTION
The image obtained through the zoom CANNOT be saved in the instrument’s memory
5.3.4. Menu Palette and isotherm lines’ functions In this menu, it is possible
to select the type of colour palette associated with the IR image and define
the parameters of the isotherm line function. 1. Touch the screen or press key
MENU/OK to enter the main menu.
EN – 33
THT500x – THT600x
2. Touch the icon ” ” to enter the “Palette” menu. The screen in Fig. 40
right side appears on the display.
Fig. 40: Selection of colour palettes and isotherm lines’ functions
3. Touch the icon corresponding to the desired colour palette, which will be
automatically changed on the display. The following options are available:
Iron
Rainbow
Grey scale
Grey Inverted
Brown hot
Blue/Red Hot/Cold Feather
4. Touch the icon ” ” to activate the isotherm line function “Alarm high Temp.”. The following screen appears on the display:
Fig. 41: Selection of isotherm line Alarm high Temp
5. Touch the “Hi” field at the bottom of the display and use the arrow keys
or to set the value of the maximum temperature threshold above which the
instrument shows image spots in red colour, and the remaining spots in grey
colour (see Fig. 41).
6. Touch the icon ” ” to activate the isotherm line function “Alarm low
Temp.”. The following screen appears on the display:
EN – 34
THT500x – THT600x
Fig. 42: Selection of isotherm line Alarm low Temp. 7. Touch the “Lo” field at
the bottom of the display and use the arrow keys or to set
the value of the minimum temperature threshold below which the instrument
shows image spots in blue colour, and the remaining spots in grey colour (see
Fig. 42). 8. Touch the icon ” ” to activate the isotherm line function “Alarm
Temp. range”. The following screen appears on the display:
Fig. 43: Selection of isotherm line Alarm Temp. range 9. Touch the “Hi” and
“Lo” field at the bottom of the display and use the arrow keys or
to set the value of the maximum and minimum temperature threshold. The
instrument shows the image spots with temperature between the “Lo” and the
“Hi” threshold in orange colour, and the remaining spots in grey colour (see
Fig. 43).
10. Touch the icon ” ” to activate the isotherm line function “Visible
range”. The following screen appears on the display: EN – 35
THT500x – THT600x
Fig. 44: Selection of Visible range 11. Touch the “Hi” and “Lo” fields at the
bottom of the display and use the arrow keys or
to set the value of the maximum and minimum temperature threshold. The
instrument shows as radiometric IR image the spots with a temperature between
the “Lo” and the “Hi” threshold, and as a visible image the spots with a
temperature outside that range (see Fig. 44).
CAUTION
Le
The isotherm lines’ functions can be used only with the instrument set to
Normal measuring mode (see § 5.3.1.2)
EN – 36
THT500x – THT600x
5.3.5. Menu Parameters In this menu it is possible to set the value of the
following correction parameters, necessary for a correct temperature
measurement to be performed by the instrument:
Material emissivity see § 5.3.1.2 Ambient temperature Reflection temperature
Relative humidity Temperature compensation (offset) Distance from target
Parameters reflection temperature and ambient temperature Objects with a low
emissivity may reflect infrared energy coming from adjacent objects; this
energy is added to the energy of the object itself, thus causing possible
measurement mistakes. In several situations, there are sources of heat with a
higher temperature than the temperature found near the object being measured.
In this case, it is necessary to compensate this reflected energy by entering
the presumed temperature value of the adjacent heat source into the thermal
camera. In most of the applications, the reflection temperature is identical
to the ambient temperature and has negligible effects on temperature
measurement on objects with a high emissivity.
Ambient temperature which can be set within the range: -10°C ÷ 50°C Reflection
temperature set within the range: 0.0°C ÷ 650.0°C (THT500, THT600, THT600L)
Reflection temperature set within the range: 0.0°C ÷ 1200.0°C (THT500H,
THT600H)
Parameter Temperature compensation (Offset) This parameter can be set if, in
automatic mode, you are sure of the values which the temperature levels
associated with the colour palette must take (see § 5.4). In this case, the
levels ate increased or decreased by the quantity inserted in that field.
Offset which can be set within the range: -5.0°C ÷ 5.0°C
Parameter Distance This parameter identifies the distance between the thermal
camera and the object to be measured. In most of the applications, the
temperature levels associated to the colour palette (see § 5.4) are influenced
negligibly by small variations of distance. Therefore, it is possible to leave
this parameter set to the default value without having significant errors on
measurement. For distances higher than 300m it is possible to have variations
1°C in temperature level.
Distance which can be set within the range: 0m ÷ 2000m
Parameter Relative humidity This parameter identifies the value of relative humidity of the environment where measurement is carried out. In most of the applications, the temperature levels associated to the colour palette (see § 5.4) are influenced negligibly by small variations of humidity.
EN – 37
THT500x – THT600x
Therefore, it is possible to leave this parameter set to the default value
without having significant errors on measurement.
Relative humidity %RH which can be set within the range: 0% ÷ 100% 1. Touch
the screen or press key MENU/OK to enter the main menu. 2. Touch the icon ” ”
to enter the “Parameters” menu. The following screens are shown
on the display: Ambient Temp. setting
Touch the icon ” ” to open the section of which to define ambient temperature.
The screen to the side appears on the display.
Use the arrow keys or or touch the arrow icons found in the “Ambient
temperature” box to set the value.
Touch the screen to quit the section.
Reflection Temp. setting Touch the icon ” ” to open the section of
which to define reflection temperature. The screen to the side appears on the
display. Use the arrow keys or or touch the arrow icons found in the
“Reflection temperature” box to set the value. Touch the screen to quit the
section.
Relative humidity setting Touch the icon ” ” to open the section of
which to define relative temperature. The screen to the side appears on the
display. Use the arrow keys or or touch the arrow icons found in the “Relative
humidity” box to set the value. Touch the screen to quit the section.
Temp. compensation setting
EN – 38
THT500x – THT600x
Touch the icon ” ” to open the section of which to define temperature
compensation. The screen to the side appears on the display.
Use the arrow keys or or touch the a r r o w i c o n s f o u n d i n t h e ”
Te m p . Compensation” box to set the value.
Touch the screen to quit the section.
Distance setting Touch the icon ” ” to open the section of
which to define the distance from target. The screen to the side appears on
the display. Use the arrow keys or or touch the arrow icons found in the
“Distance” box to set the value. Touch the screen to quit the section.
Emissivity setting Touch the icon ” ” to open the section of
which to define material emissivity. The screen to the side appears on the
display. Use the arrow keys or or touch the arrow icons found in the
“Emissivity” box to set the value. Touch the screen to quit the section.
EN – 39
THT500x – THT600x
5.3.6. Alarm menu In this section, it is possible to set the high and low
threshold values the instrument takes into consideration to activate the
acoustic alarm on temperature measurements.
CAUTION
Le
This function can only be used after activating the alarm condition in the
“Settings” menu (see § 5.3.1.2). 1. Touch the screen or press key MENU/OK to
enter the main menu. 2. Touch the icon ” ” to enter the “Alarm” menu. The
following screens are shown on the display:
Fig. 45: Setting of limit thresholds on alarms 3. Touch the icon ” ” to define
the high threshold value associated with the alarm. The
screen in Fig. 45 left side appears on the display. 4. Use the arrow keys or
or touch the arrow icons found in the “Above MAX alarm”
box to set the value according to the measuring range set on the instrument.
The instrument will sound for measured temperature values above the set
threshold. 5. Touch the icon ” ” to define the low threshold value associated
with the alarm. The screen in Fig. 45 right side appears on the display. 6.
Use the arrow keys or or touch the arrow icons found in the “Below MIN alarm”
box to set the value according to the measuring range set on the instrument.
The instrument will sound for measured temperature values below the set
threshold.
EN – 40
THT500x – THT600x
5.4. ADJUSTING THE IMAGE TEMPERATURE The instrument allows adjusting the temperature associated with the framed image on the display (levels high, low and span) as follows:
Automatic (AUTO) mode the minimum and maximum temperature levels of the framed
object on the display and associated with the colour palette are automatically
defined by the instrument and dynamically vary when moving it. This (default)
option, which can be used in most cases, allows for an optimum display of the
IR image. The relationship between temperature and colour of the palette is
linear.
Histogram (HG) mode the minimum and maximum temperature levels of the object
framed on the display are always defined automatically by the instrument, as
in the Auto mode, but in this case, the areas of the image in which
temperature values are very different from the values of adjacent areas are
highlighted. The relationship between temperature and colour of the palette is
non-linear according to a histogram algorithm. This mode emphasizes image
display in very dark working environments.
Manual (MANUAL/LOCK) mode the minimum and maximum temperature level of the
framed target on the display are manually set by the user. This mode,
particularly useful to clearly identify only some areas of the image, is
recommended in case of advanced thermographic operations.
1. Press key
or touch the icon “AUTO” found at the bottom on the right side of the
display. The screens in Fig. 46 show the selection of modes “AUTO” and “HG”.
Fig. 46: Setting the Automatic and Histogram modes
2. Press key
or touch the icon “AUTO” by selecting the “MANUAL” option. The
following screens are shown on the display:
EN – 41
THT500x – THT600x
Fig. 47: Setting the Manual mode 3. Use the arrow keys or to set the
temperature values associated with the high and
low levels by steps of 0.1°C at the same time (see Fig. 47 left side). 4.
Touch the icon ” ” near the levels to block the set temperature values. 5. Use
the arrow keys or to set the temperature value associated with the high level
by steps of 0.1°C (see Fig. 47 middle). 6. Touch the icon ” ” to block the
set temperature value. 7. Use the arrow keys or to set the temperature value
associated with the low level
by steps of 0.1°C (see Fig. 47 right side). 8. Touch the icon ” ” to block
the set temperature value.
EN – 42
THT500x – THT600x
5.5. SAVING IR IMAGES AND VIDEOS The instrument is capable of saving both IR
images and videos in the internal memory or on the inserted micro SD card.
Each image is automatically saved in a JPG (snapshot) and HIR format (which
can only be opened via the software THTLink see § 6). IR videos are saved in
a standard MP4 format. The following operations are possible: Fixing the
images on the display Saving the images in the instrument’s memory Adding
voice annotations when saving the image Adding text annotations when saving
the image Changing the image parameters upon saving 5.5.1. Image saving An IR
image on the display may be saved after it has been frozen on the display.
Proceed as follows: 1. Press the T (Trigger) key to freeze an IR image on the
display. The following screen
appears on the display:
Fig. 48: Image saving 2. Touch the icon ” ” or press again the T (Trigger) key
to confirm saving the image if no
change needs to be made to it. Touch the display to unfreeze the IR image 3.
In case it is necessary to change the image parameters, touch the
corresponding icons
” “, ” “, ” ” and ” “, follow the procedures described in the previous
chapters and touch the icon ” ” to confirm. 4. Touch the icon ” ” to add a
text annotation to the image. The screen in Fig. 49 right side appears on
the display.
EN – 43
THT500x – THT600x
Fig. 49: Adding a text annotation to the image 5. Insert the text comment by
using the virtual keyboard and confirm with ” ” or touch
“X” to go back to the previous screen. 6. Confirm saving the image with the
text annotation by touching the icon ” “. 7. Insert the connector of the
earphone set into the “Audio” input of the instrument (see
Fig. 4 part 2) and touch the icon ” ” to add a voice annotation (max 60s for
each image) to the image. The following screen appears on the display:
Fig. 50: Adding a voice annotation to the image 8. The indication “REC” and
the elapsed time are shown at the top of the display to
indicate that recording is in progress. 9. Confirm saving the image with the
voice annotation by touching icon ” “. Touch the
icon ” ” to open the section containing the information about the saved vocal
annotation 5.5.2. Recording IR videos The instrument allows recording and
saving also IR videos with or without audio in a MP4 format, as follows: 1.
Insert the connector of a headphone and microphone set into the “Audio” input
of the instrument (see Fig. 4 part 2) 2. Press and hold key T (Trigger) for
at least 2s. The indication and the elapsed time are shown at the top of the
display to indicate that recording is in progress (see Fig. 51 left side).
EN – 44
THT500x – THT600x
Fig. 51: IR video recording 3. Press key T (Trigger) to stop and automatically
save the recording in the instrument’s
memory. Touch the icon ” ” to open the section containing the information
about the saved video 5.5.3. Gallery menu In this section if is possible to
recall and display the gallery of IR images and videos saved in the
instrument’s menu or on the inserted micro SD card. In the same section it is
possible to see the text annotations and listen to the voice annotations made
while saving the images. 1. Press key to enter the gallery of the images and
videos saved in the instrument’s memory or on the micro SD card. The following
screen in Fig. 52 left side is shown on the display
Fig. 52: Recalling on the display the images saved 2. Use the arrow keys or or
touch the icons ” ” or ” ” to recall the desired image on
the display. 3. Touch the icon ” ” to open the section containing the
information about the saved
image. The screen in Fig. 52 right side appears on the display. 4. Touch the
icon ” ” to play a possible saved IR video. 5. Touch the icon ” ” to display
the icons ” “, ” “, ” ” and ” ” to make changes on
the image recalled on the display. Touch the icon ” ” to confirm the changes
made, by overlapping the modified image or saving a copy. 6. Touch the icon
“X” to quit without saving or to go back to the main menu. 7. Touch the icon ”
” to delete the image recalled on the display.
EN – 45
THT500x – THT600x
5.6. HDMI VIDEO OUTPUT The HDMI video output available in the instrument (see
Fig. 4 Part 3) enables displaying the IR image acquired on an external
monitor or device compatible with HDMI video recording. To connect the
instrument, proceed as follows:
1. Connect the instrument to the external monitor/device using the HDMI video
cable provided.
2. Turn on the external HDMI monitor or device. 3. Switch on the instrument.
4. Check for the presence of the IR image on the external monitor or device.
The image
disappears from the display. 5. Touch the instrument’s display to display the
image again. The image disappears from
the external monitor or device. 6. At the end of the operations, switch off
the external monitor or device and disconnect
the video cable from the instrument.
5.7. CHARACTERISTICS OF THE LENS The instrument is provided with a 22mm focus
lens (THT600, THT600H), 38mm (THT600L) or 9mm (THT500, THT500H). The theory of
operation is reported below, based on the 22mm lens.
Definitions
FOV (Field Of View) Visible range represents the maximum angular opening
(expressed in degrees) the instrument is capable of managing at a certain
distance.
IFOV (Instantaneous Field Of View) represents the smallest detail within the
FOV, that the instrument can detect at a certain distance. It is expressed in
radians by the following formula:
IFOV (theoretical) = (size of sensor’s pixels) / (focus length of the lens)
D:S ratio Ratio Distance / Cross-section of the target object it provides
information on the maximum distance between the instrument and the target
having a certain cross-section (spot) in order to obtain correct temperature
measurements. It is expressed as:
D:S (theoretical) = 1 / IFOV (theoretical)
Case of instrument THT600
FOV = 17° (Horizontal) x 12.7° (Vertical) Focus lens = 22mm Size of sensor’s
pxls = 17µm IFOV (theoretical) = 17µm / 22mm = 0.77mrad D:S (theoretical) = 1
/ IFOV (theoretical) = 1298:1
EN – 46
THT500x – THT600x
Fig. 53: Representation of the THT600 instrument’s field of view FOV
Typically, the IFOV parameter (real) is always considered as approx. 3 times
higher
than the theoretical one, therefore the D:S ratio (real) is approx. 3 times
lower than the theoretical one. This means that, for THT600: D:S (real) ~
433:1 5.8. USE OF THE SCREENING MODE 1. Switch on the instrument. 2. Set the
emissivity parameter to a value between 0.95 and 0.98 (typically 0.95). 3.
Activate the “Screening” mode (see § 5.3.1.2). 4. Activate the alarm condition
(see § 5.3.1.2) and set the maximum temperature threshold associated with one
of the measuring cursors (see § 5.3.6). 5. Activate the Face mode (see §
5.3.2). 6. Select the desired color palette (Iron or Grey scale recommended
see § 5.3.4). 7. Select the AUTO measuring mode (see § 5.4). 8. Correctly
focus the item to be tested (see § 5.2). 9. Frame the item to be tested at a
distance of max 2m. 10. The following screen appears on the display.
Fig. 54: Display of the alarm condition in Screening function
CAUTION
EN – 47
THT500x – THT600x
Le
The Screening function allows measuring the temperature of the human body, but
the instrument CAN IN NO WAY be used as a medical device.
Temperature measurement with the Screening function cannot replace medical
evaluation.
6. USING THE THTLINK SOFTWARE
The software “THTLink” can be used to analyse the images saved in the
instrument’s memory.
6.1. MINIMUM SYSTEM REQUIREMENTS
Hardware:
PC 3.70Ghz 32bit/64 bit
RAM memory:
8GB
Output interface:
USB ports or SD card reader
Screen resolution:
1920×1080
Operating system:
Windows 7 or higher
Software applications: Microsoft .Net Framework 4.0
6.2. INSTALLING THE THTLINK SOFTWARE 1. Download the THTLink software from www .ht-instruments.com/download website 2. Launch file “THTLink_setup.exe” and follow the guided installation procedure.
6.3. MAIN CHARACTERISTICS OF THE THTLINK SOFTWARE IR images (with HIR format) can be opened with the software, as shown in the following Fig. 55.
EN – 48
THT500x – THT600x
Fig. 55: Image display with the THTLink software Main characteristics of the
THTLink software: Display of IR, visible, Fusion, PiP images Insertion of
advanced analysis tools (spots, lines, areas, deltaT, isotherm lines)
Realization of graphs from IR images Realization of print reports Playback of
the voice and text annotations saved on the images · For information about the
use of THTLink, please refer to the Help on line of the
software itself · The THTLink software is downloadable from www.ht-
instruments.com/download
7. MAINTENANCE
7.1. GENERAL INFORMATION While using and storing the instrument, carefully
observe the recommendations listed in this manual in order to prevent possible
damage or danger during use. Do not use the instrument in environments with
high humidity levels or high temperatures. Do not expose to direct sunlight.
Always switch off the instrument after use. 7.2. RECHARGING THE INTERNAL
BATTERY The instrument is designed to be supplied with a Li-ION rechargeable
battery. With symbol ” ” shown on the display, it is necessary to recharge the
battery. Recharge can be performed as follows: By connecting the instrument to
the electric mains through the battery charger provided
with the instrument Insert the battery into the recharging base and connect it
to the electric mains.
CAUTION
EN – 49
THT500x – THT600x
· Recharge the battery at an environmental temperature between 0°C and
50°C (32°F and 122°F). With a temperature outside this range, the
battery may overheat or break and, at any rate, reduce its life cycle. · The
battery must not be removed from the instrument while recharging. · When using
the instrument for the first time, recharge the battery for at
least 3 hours.
Recharging the battery with direct connection to the electric mains
1. Connect the provided battery charger to the AC electric mains and the output to the
instrument’s micro USB port (see Fig. 3 Part 2).
2. With the instrument turned off, the indicator of the battery charge level takes the
flashing symbols ”
” in a sequence.
3. When the symbol ” ” appears steady on the display, the charging process is
complete (see Fig. 56).
Fig. 56: Indication of complete recharge of the battery
4. With the instrument turned on, the symbol ” ” is shown on the display. 5.
Disconnect the battery charger from the instrument and from the electric
mains.
Recharging by connection to the recharging base 1. Connect the provided
battery charger to the AC mains and the provided recharging
base. The green “PWR” LED on the base turns on. 2. Insert the battery into the
recharging base. The red “CHG” LED on the base turns on. 3. Carry on the
recharging process until the “CHG” LED turns off. 4. Remove the battery,
disconnect the recharging base and the battery charger from the
electric mains. 7.3. CLEANING THE INSTRUMENT Use a soft and dry cloth to clean
the instrument. Never use wet cloths, solvents, water, etc.
7.4. END OF LIFE
WARNING: this symbol found on the instrument indicates that the appliance, its
accessories and the batteries must be collected separately and correctly
disposed of.
7.5. ACCESSORIES 7.5.1. Accessories provided · Built-in focal lens for IR
measurements f= 22mm (THT600, THT600H) · Built-in focal lens for IR
measurements f= 38mm (THT600L) · Built-in focal lens for IR measurements f=
9mm (THT500, THT500H)
EN – 50
· Lens protection cap · Rechargeable Li-ION battery, 3.7V 5200mAh, 2 pieces · AC/DC 100-240V/5V adapter + universal plugs · Battery recharging base · Micro SD card, 16GB · Adapter for micro SD card · Micro USB cable · HDMI video cable · Earphone set · ISO test report · Quick user guide · Rigid transport bag
THT500x – THT600x
Cod. THTBATL Cod. THTCBL
8. TECHNICAL SPECIFICATIONS
Temperature measurement (THT500, THT600, THT600L)
Range
Resolution
Accuracy (*)
-20.0°C ÷ 650.0°C
0.1°C
±2%reading or ±2°C (higher value)
-4.0°F ÷ 1202.0°F
0.1°F
(*) Environmental temperature: 10°C ÷ 35°C, Temperature of target: >0°C
±2%reading or ±3.6°F (higher value)
Temperature measurement (THT500H, THT600H)
Range
Resolution
-20.0°C ÷ 1200°C
0.1°C
-4.0°F ÷ 2192.0°F
0.1°F
(*) Environmental temperature: 10°C ÷ 35°C, Temperature of target: >0°C
Accuracy (*) ±2%reading or ±2°C (higher value) ±2%reading or ±3.6°F (higher value)
EN – 51
THT500x – THT600x
Temperature measurement in Screening mode
Range
Resolution
32.0°C ÷ 42.0°C
0.1°C
89.6°F ÷107.6°F
0.1°F
Accuracy ±0.5°C ±0.9°F
General specifications Type of IR sensor / Resolution:
Spectrum response: Visible range (FOV) / Lens:
IFOV:
Thermal sensitivity / NETD: Image frequency: Focusing: Minimum focus distance:
Temperature readings: Available colour palettes: Laser pointer: Electronic
zoom: Emissivity correction: Image adjustment modes: Measuring functions:
Advanced analyses:
Face temp. detection: Inbuilt photo camera: Image modes: Laser distance
measurement:
Alarm conditions: Video output: Image format: IR video recording: Voice
annotation: Text annotation: Memory: No. of images/videos:
PC interface: Interface to mobile devices:
UFPA (384x288pxl, 17µm) (THT600x)
UFPA / (160x120pxl,17µm) (THT500x)
8 ÷14µm
17° x 12.7° / 22mm, f 1.0 (THT600, THT600H) 9.8° x 7.3° / 38mm f 1.0 (THT600L)
17° x 13° / 9mm f 1.0 (THT500, THT500H) 0.77mrad (THT600, THT600H) 0.45mrad
(THT600L) 1.89mrad (THT500x) <0.05°C@30°C (86°F) / 50mK 50Hz manual 0.5m °C,
°F, K 8 palettes+ 4 isotherm lines Class 2 according to IEC 60825-1 x1.0 ÷
x32.0 in steps of 0.1 0.01 ÷ 1.00 in steps of 0.01 Automatic / Manual /
Histograms (HG) corrections according to environmental temperature, reflected
temperature, distance, relative humidity, offset. fixed central cursor spots
(3), lines (2), areas (3), “Hot/Cold” cursors max 10 people at the same time
(distance 2m) 5Mpxl, FOV 59° IR, Visible, Fusion PiP, Auto Fusion range:
0.05m÷30m, accuracy:±5mm ((THT600/H) range: 0.05m÷30m, accuracy:±1.5mm
(THT600L) visible and acoustic HDMI JPG (snapshots), HIR (radiometric) MP4
format up to 60s / image with virtual keyboard Internal (3.4GB) + micro SD
card 16GB (max 32GB) 1000 photos/45min video (internal memory) >6000 photos
(micro SD card) micro USB WiFi (with APP HTProCamera)
EN – 52
Power supply Internal supply: External supply: Battery duration: Display
Characteristics:
Mechanical characteristics Dimensions (L x W x H):
Weight (battery included):
THT500x – THT600x
rechargeable Li-ION battery, 3.7V 5200mAh adapter 100-240VAC (50/60Hz)/5VDC,
2400mA approx. 4 hours (stand-by and WiFi off)
Colour, TFT LCD 3.5″, 640x480pxl capacitive touch-screen
272x101x148mm (11x4x6in) (THTx00, THTx00H) 290 x 101 x 148mm (11x4x6in)
(THT600L) 850g (30ounces) (THTx00, THTx00H) 900g (32ounces) (THT600L)
8.1. ENVIRONMENT
8.1.1. Environmental conditions for use
Operating temperature:
-15°C÷ 50°C (5°F÷ 122°F)
Storage temperature:
-40°C÷ 70°C (-40°F÷ 158°F)
Allowable relative humidity:
10%RH ÷ 90%RH
Mechanical protection:
IP54 in compliance with IEC 529
Falling test:
2m
Shock:
25G in compliance with IEC60068-2-29
Vibrations:
2G in compliance with IEC60068-2-6
This instrument complies with Directive EMC 2014/35/EU This instrument
satisfies the requirements of European Directive 2011/65/EU (RoHS)
and 2012/19/EU (WEEE).
9. ASSISTANCE
9.1. WARRANTY CONDITIONS This instrument is warranted against any material or
manufacturing defect, in compliance with the general sales conditions. During
the warranty period, defective parts may be replaced. However, the
manufacturer reserves the right to repair or replace the product. Should the
instrument be returned to the After-sales Service or to a Dealer, transport
will be at the Customer’s charge. However, shipment will be agreed in advance.
A report will
EN – 53
THT500x – THT600x always be enclosed to a shipment, stating the reasons for
the product’s return. Only use original packaging for shipment; any damage due
to the use of non-original packaging material will be charged to the Customer.
The manufacturer declines any responsibility for injury to people or damage to
property. The warranty shall not apply in the following cases: · Repair and/or
replacement of accessories and battery (not covered by warranty). · Repairs
that may become necessary as a consequence of an incorrect use of the
instrument or due to its use together with non-compatible appliances. ·
Repairs that may become necessary as a consequence of improper packaging. ·
Repairs which may become necessary as a consequence of interventions performed
by unauthorized personnel. · Modifications to the instrument performed without
the manufacturer’s explicit
authorization. · Use not provided for in the instrument’s specifications or in
the instruction manual. The content of this manual cannot be reproduced in any
form without the manufacturer’s authorization.
Our products are patented and our trademarks are registered. The manufacturer
reserves the right to make changes in the specifications and prices if this is
due to improvements in technology.
9.2. ASSISTANCE If the instrument does not operate properly, before contacting
the After-sales Service, please check the conditions of the batteries and
replace them, if necessary. Should the instrument still operate improperly,
check that the product is operated according to the instructions given in this
manual. Should the instrument be returned to the After-sales Service or to a
Dealer, transport will be at the Customer’s charge. However, shipment will be
agreed in advance. A report will always be enclosed to a shipment, stating the
reasons for the product’s return. Only use original packaging for shipment;
any damage due to the use of non-original packaging material will be charged
to the Customer.
EN – 54
HT INSTRUMENTS SA
C/ Legalitat, 89 08024 Barcelona – ESP Tel.: +34 93 408 17 77, Fax: +34 93 408
36 30 eMail: info@htinstruments.com eMail: info@htinstruments.es
Web: www.htinstruments.es
SRL
Via della Boaria, 40 48018 Faenza (RA) – ITA
Tel: +39 0546 621002 Fax: +39 0546 621144
eMail: ht@htitalia.it
Web: www.ht-instruments.com HT INSTRUMENTS BRASIL
Rua Aguaçu, 171, bl. Ipê, sala 108 13098321 Campinas SP – BRA Tel: +55 19
3367.8775 Fax: +55 19 9979.11325
eMail: vendas@ht-instruments.com.br Web: www.ht-instruments.com.br HT
INSTRUMENTS USA LLC
HT ITALIA
Read User Manual Online (PDF format)