Clarke SHHHAIR 30 Silent Air Compressor Instruction Manual

June 5, 2024
Clarke

Clarke SHHHAIR 30 Silent Air Compressor logo

Clarke SHHHAIR 30 Silent Air Compressor

INTRODUCTION

Thank you for purchasing this Air Compressor.
Before attempting to operate the machine, it is essential that you read this manual thoroughly and carefully follow all instructions given. In doing so you will ensure the safety of yourself and that of others around you, and you can also look forward to the product giving you long and satisfactory service.

SPECIFICATION

Power supply 230 V/ 50 Hz
Dimensions (L x W x H) 330 x 470 x 330 mm
Weight 18 kg
Receiver capacity 9L
Compressor oil 500ml synthetic oil
Ingress protection IP20
Max working pressure 8 Bar/116 psi
Max flow rate 18.2 L/min @100 psi
Sound power level 40 dBA
Duty cycle 50% (15mins on/15 minutes off)

Please note that the details and specifications contained herein are correct at the time of going to print.

GUARANTEE

This product is guaranteed against faulty manufacture for a period of 12 months from the date of purchase. Please keep your receipt as proof of purchase.
This guarantee is invalid if the product is found to have been abused or tampered with in any way, or not used for the purpose for which it was intended.
Faulty goods should be returned to their place of purchase, no product can be returned to us without prior permission. This guarantee does not effect your statutory rights.

GENERAL SAFETY WARNINGS

WARNING: WHEN USING ELECTRICAL TOOLS, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND PERSONAL INJURY
WARNING: READ ALL THESE INSTRUCTIONS BEFORE ATTEMPTING TO OPERATE THIS PRODUCT AND KEEP THESE INSTRUCTIONS IN A SAFE PLACE.

WORK AREA

  1. Keep the work area clean and well lit. Floors should always be kept clear. Cluttered or dark areas invite accidents.
  2. Keep children and bystanders away while operating a power tool. Distractions can cause loss of control.
  3. The compressor should only be used in areas with adequate ventilation and should not be exposed to heat or used near flammable substances

PERSONAL SAFETY

  1. ALWAYS stay alert, watch what you are doing and use common sense when operating the compressor. Do not use the compressor while you are tired or under the influence of medication, drugs or alcohol. A moment of inattention can result in personal injury.
  2. ALWAYS use eye protection when operating compressed air equipment, and ensure that others in the work area are protected from flying particles from the front and from the side.
  3. ALWAYS protect yourself against electric shock. Never operate the compressor in wet or damp locations.
  4. NEVER over-reach. Keep your proper footing and balance at all times to enable better control of the compressor in unexpected situations.
  5. NEVER attempt any complex repairs yourself. If you have a technical problem contact your local dealer.
  6. ALWAYS store the compressor out of reach of children.
  7. ALWAYS protect your hearing. Ear protection should be worn when operating this compressor and it’s associated power tools.
  8. NEVER direct the air stream at people or animals, as injury may result. Compressed air can cause soft tissue damage and propel dirt and other particles at high speed.
  9. NEVER insert your fingers or other objects inside the motor housing. Never operate the compressor without the cover in place.

GENERAL MACHINE USE AND CARE

  1. Prior to use, all operators should become familiar with the instructions in this booklet especially the ON/OFF switch for emergency stopping.
  2. ALWAYS maintain the compressor with care and keep it clean for best /safest performance.
  3. NEVER use this compressor if any part is damaged. Have it inspected and repaired by your dealer.
  4. NEVER attempt to modify the air compressor, tank, fittings or attachments in any way. Doing so will invalidate the guarantee and could result in personal injury.
  5. NEVER abuse the power cable. Never pull on the cable when removing the plug from the socket, or lift the compressor by the power cable.
  6. ONLY use extension leads that are of an appropriate power rating and suitable for the work environment. Extension leads must have an earth connection. Inspect the extension lead regularly and replace if damaged.
  7. ONLY USE RECOMMENDED PARTS: To avoid the risk of bursting, only hoses with a rated pressure of 10 bar, or more should be used. Never attempt to repair damaged hoses.
  8. NEVER abuse the compressor by standing on it.

AIRLINE HOSES

  1. ALWAYS ensure that equipment or power tools used in conjunction with the compressor have a safe working pressure exceeding that of the machine.
  2. ALWAYS keep the air hose away from any attached power tools and ensure that the operator is not restricted by the length of the hose.
  3. ALWAYS take care when a long air hose is required in the work area as it presents a trip hazard. Coil the hose away as soon as the job is finished.
  4. ALWAYS avoid kinking or trapping the air hose. Always replace faulty hoses and never attempt a repair if a leak is detected.
  5. NEVER abuse hoses or connectors. NEVER carry an air tool by the hose, or yank it to disconnect from the air supply. Keep hoses away from heat, oil and sharp edges. Check hoses for leaks or worn condition before use and ensure that all connections are secure.
  6. ALWAYS ensure that the air supply is turned off at the machine outlet and any air pressure vented from within the compressor and any attached equipment when disconnecting air hoses or other equipment.

AIR COMPRESSOR SAFETY INSTRUCTIONS

  1. ONLY USE WITHIN THE RECOMMENDED OPERATING TEMPERATURE RANGE: This compressor should only be used in an ambient temperature of between +5OC and +40OC (never at or below freezing temperatures).
  2. NEVER USE AN AIR COMPRESSOR WHICH APPEARS DEFECTIVE OR IS OPERATING ABNORMALLY: If the compressor operates unusually or makes strange noises, switch off immediately and purge the air reservoir. Arrange repairs with your nearest dealer.
  3. BREATHING QUALITY AIR: This compressor should not be used to supply breathing quality air.
  4. SAFETY VALVE: Never remove or attempt to adjust the safety valve. The maximum pressure is factory set. Keep the safety valve free from paint and other accumulations.
  5. AVOID UNINTENTIONAL STARTING: Do not move the compressor when it is connected to the mains power supply.
  6. BEFORE EACH USE CHECK THE COMPRESSOR AND HOSE FOR DAMAGED PARTS: Never use the compressor if it has been damaged in any way. Have the compressor repaired by a qualified service engineer. Do not use the compressor if the On/Off switch does not operate correctly.
  7. KEEP THE MOTOR AIR VENTS CLEAR: Keep the motor vents clear and free from dust. Wipe regularly to maintain an adequate supply of clean air. Avoid using in dusty conditions.
  8. OPERATE THE COMPRESSOR AT THE CORRECT VOLTAGE: Make sure that the mains supply voltage is the same as the voltage shown on the label.
  9. ALWAYS adjust the pressure regulator to the recommended setting for the particular spray gun or air tool being used.
  10. When using the compressor for painting:
    • DO NOT work in enclosed areas or near naked flames.
    • Ensure that the area in which you are working has good ventilation.
    • Protect your nose and mouth with a suitable face mask.
    • ALWAYS check the safety data sheets for substances being sprayed & ensure manufacturer’s instructions are followed.
  11. DO NOT USE THIS COMPRESSOR TO INFLATE SMALL, LOW-PRESSURE OBJECTS: Items such as children’s toys or footballs can explode if over-inflated.
  12. NEVER STOP THE COMPRESSOR BY REMOVING THE PLUG OR SWITCHING OFF AT THE MAINS SUPPLY: Always use the On/Off switch on the compressor.

ELECTRICAL CONNECTIONS

WARNING! READ THESE ELECTRICAL SAFETY INSTRUCTIONS THOROUGHLY BEFORE CONNECTING THE PRODUCT TO THE MAINS SUPPLY.

Before switching the product on, make sure that the voltage of your electricity supply is the same as that indicated on the rating plate. This product is designed to operate on 230VAC 50Hz. Connecting it to any other power source may cause damage.
This product may be fitted with a non-rewireable plug. If it is necessary to change the fuse in the plug, the fuse cover must be refitted. If the fuse cover becomes lost or damaged, the plug must not be used until a suitable replacement is obtained.
If the plug has to be changed because it is not suitable for your socket, or due to damage, it should be cut off and a replacement fitted, following the wiring instructions shown below. The old plug must be disposed of safely, as insertion into a mains socket could cause an electrical hazard.

WARNING! THE WIRES IN THE POWER CABLE OF THIS PRODUCT ARE COLOURED IN ACCORDANCE WITH THE FOLLOWING CODE: BLUE = NEUTRAL BROWN = LIVE YELLOW AND GREEN = EARTH

If the colours of the wires in the power cable of this product do not correspond with the markings on the terminals of your plug, proceed as follows.

  • The Blue wire must be connected to the terminal marked N or coloured Black.
  • The Brown wire must be connected to the terminal marked L or coloured Red.
  • The Yellow and Green wire must be connected to the terminal marked E or or coloured Green. Clarke SHHHAIR 30 Silent Air Compressor fig 1

We strongly recommend that this machine is connected to the mains supply via a Residual Current Device (RCD). If in any doubt, consult a qualified electrician. DO NOT attempt any repairs yourself.

PREPARING FOR USE

Before connecting your compressor to the mains supply, check the following:-

  • Firstly, ensure the compressor is on level ground. Do not allow it to run if it is standing on an incline.
  • Check also that the mains voltage corresponds with that shown on the data label on the side of the compressor.
  • The ON/OFF switch is in the OFF position.

FITTING THE INLET FILTER

  1. Remove the cap from the top of the air inlet tube. Clarke SHHHAIR 30 Silent Air Compressor fig 3
  2. Push the air inlet filter supplied  securely on to the tube.

FITTING THE REGULATOR

  1. Fit the regulator into position as shown.
  2. Do not overtighten the nut.

ADDING OIL

The compressor is supplied without any oil inside.v

  1. Remove the oil cap from the top of the oil filler tube. Clarke SHHHAIR 30 Silent Air Compressor fig 5
  2. Pour the oil into the oil filler tube using the funnel on the bottle, then replace the oil cap.
    • Only use Clarke synthetic compressor oil, available from your Clarke dealer (Part No. 3050795).
  3.  Make sure that the oil level is half way up the oil sight glass.

SWITCHING THE AIR COMPRESSOR ON

  1. To start the compressor, turn the ON/OFF switch to the ‘I’ (ON) position – the motor should start immediately. NOTE: If the motor fails to start immediately, the air receiver may already be full of air. Check the tank pressure gauge (shown on the right). If you release air, by opening the air outlet tap, the motor will start automatically once the cut-in pressure is reached.

  2. Allow the compressor to run for 10 – 15 seconds, with the air outlet tap, (A) open.

    • This will distribute the lubricating oil.
  3. Close the outlet tap and connect a suitable air hose to the filter/regulator outlet (B). Connect the other end to the equipment to be used.

  4. Check the safety valve by pulling on the end cap shown.

    • Pliers will be needed to grip the end cap and pull against the spring. Air should hiss out when the valve is pulled.
  5. Adjust the pressure regulator.

    • To do this, lift the pressure regulator knob (C), and turn it clockwise to increase the pressure, anticlockwise to decrease the pressure. The pressure is shown on the outlet gauge (D).
    • To lock the pressure regulator knob, push the pressure regulator knob down until it clicks into place.
      IMPORTANT: Always refer to the accessory manufacturers recommendations for optimum operating pressures for their equipment.
  6. With operating pressure set, open the air outlet tap.

  7. If the machine pumps continuously without cutting out then the compressor is too small for the application/tool being used, and damage may result. Consult your Clarke dealer.
    NOTE: DO NOT exceed the duty cycle for the machine (see Specifications).

SHUTTING DOWN THE COMPRESSOR

  1. To shut off the compressor, simply turn the ON/OFF switch to the O (OFF) position.
  2. Close the air outlet tap and trigger the equipment (spray gun, air tool etc.) to release air from the air hose before disconnecting the hose from the machine.
  3. Before transporting your compressor or when leaving overnight, expel all air from the receiver by opening the vent valve.

DRAINING THE RESERVOIR

  1. Pressurise the reservoir slightly and then turn the compressor off.
  2. Attach the small hose supplied to the vent valve as shown.
  3. Take the compressor to the sink and place the free end of the small hose in the sink.
  4. Tilt the compressor forward slightly and slowly open the vent valve.
  5. When the reservoir has been drained, re-tighten the vent valve and remove the hose.
  6. Drain any condensate that may have accumulated in the air outlet filter, by twisting and pushing the valve upwards.

TROUBLESHOOTING

PROBLEM PROBABLE CAUSE REMEDY
The compressor will not start, or stops and will not start again Bad
connections Check the electrical connections
Blown fuse Replace fuse
Overload cutout switch has tripped Wait 25-20 mins before attempting to

restart
Compressor does not start| Air receiver charged| Open drain valve to expel air. Compressor should start again when pressure reduces to approx 95 psi.
The compressor does not reach the set pressure and overheats easily| Inlet Air Filter is blocked NOTE: It is also possible that you are trying to use more air than the compressor is capable of delivering| Renew oil filler/air Filter plug
Air leaking from the pressure switch valve when the compressor is not running| Faulty non-return valve| First drain the receiver completely of air.

Renew the non-return valve

Air pressure from the regulator will not adjust| Broken diaphragm within the regulator body| Replace regulator
Compressor operating, but no air from outlet| Inlet air filter blocked| Renew oil filler/air Filter plug
Pressure regulator closed| Turn regulator clockwise to set required pressure
Drain valve open| Close vent valve
Bleed pipe (from Pressure Switch to non-return valve) broken or disconnected| Reconnect or replace bleed pipe

MAINTENANCE

| Daily| Monthly| Yearly
---|---|---|---
Check the oil level, See “Adding Oil” on page 6.| X| |
Drain the water collected in the air outlet filter. See Draining the Reservoir on page 11.| X| |
Remove the condensate that has collected in the air tank. See Draining the Reservoir on page 11.| X| |
Once a month check the compressor for loose connections, wear, etc.| | X|
Clean the compressor with a soft cloth.| | X|
Check the safety valve pulling the ring gently when there is pressure in the tank.| X| |
Total replacement of oil. See below.| | | X

DRAIN AND REPLACE THE OIL

Drain and replace the oil annually, as follows:

  1. Loosen the collar securing screw and remove the collar.
  2. Pull off the head, complete with sealing ring.Clarke SHHHAIR 30 Silent Air Compressor fig 14
  3. Tilt the compressor carefully on to its side, so that the oil is drained into a suitable container.
    • Dispose of the oil according to local regulations.
  4. Reassemble the head ensuring the sealing ring is in perfect condition and is located correctly.

CHECK THE NON RETURN VALVE

If the tank pressure decreases for no apparent reason, it is possible that the non-return valve is leaking. To check, ensure the tank is under pressure and the machine switched OFF,

  1. Take off the flexible hose and check if air leaks out from the valve.
  2. If so, unscrew the valve from the connection and disassemble it as shown.
  3. Clean all the components with a dry cloth and reassemble the valve taking care to place the internal rubber disc(2) as shown.
  4. Fasten the valve to the connection and join the flexible hose. If the leakage persists, the whole valve must be replaced.

REPLACING THE AIR OUTLET FILTER

The compressor must be completely depressurised before carrying out this procedure.

  1. Unscrew the cartridge from the air filter assembly.
  2. Unscrew and replace the small air filter.

STORAGE

Disconnect the mains plug and ventilate the compressor and any connected pneumatic tools. Store the compressor in a dry location. Always store upright.

ENVIRONMENTAL RECYCLING POLICY

By purchasing this product, the customer is taking on the obligation to comply with current WEEE regulations.
This means that this product must not be disposed of with general household waste. It must be disposed of according to the laws governing Waste Electrical and Electronic Equipment (WEEE) at a recognised disposal facility.
This product contains valuable raw materials. Metal products should be taken to your local civic amenity site for recycling of metal products.

COMPONENT DIAGRAMS & PARTS LIST

Clarke SHHHAIR 30 Silent Air Compressor
fig 18

PUMP ELECTRICAL DIAGRAM

Clarke SHHHAIR 30 Silent Air Compressor fig
19 Clarke SHHHAIR 30 Silent Air Compressor fig
20

NO DESCRIPTION
C0024 Rubber Oil Plug Ø8
C2638 Spacer
C2639 Rubber Grommet
C1099 Oil Level Glass 1/2″
C1769 Kit Holding Band L55-L88
C2585 Kit Terminal Box L88 ( 230V )
C2580 Overload Protector L88 ( 230V )
C2581 Start Relay L88 ( 230V )
C1794 Kit Intake Filter
C2247 O’ Ring
C1906 Motor Protection Ring
C0046 Non Return Valve M-F 1/8″
C0047 Quick Coupling M5XØ6
C0051 Rylsan Hose Ø4/6
C0077 Swivel Connector M1/4
C0082 Pressure 1 WAY
C0083 Connection M 1/4 L=80
C0089 Nipple 1/4″ L=95
C0091 Electric Cable MM 500
C0348 “T” Connection F-F-F 1/4″
C0133 Electric Cable 3X0.75 L.2500 ( 230V )
C015524 Reservoir
C2376 Filter Regulator
C0297 Air Hose
C0301 Exhaust Valve
C0354 Draincock M 1/4 90
C0517 Plug M1″
C0522 Aluminium Washer 1″
C0567 Nipple 1/8″
C0573 Hand Grip
C0582 Black Rubber Support D20
C1681 “L” Connection M 1/8X8
C1712 Gauge D40 1/8 0-12 BAR
C1728 Hose
C1965a Pressure Relief Valve
C2369 Outlet tap

DECLARATION OF CONFORMITY

Clarke SHHHAIR 30 Silent Air Compressor fig
21 Clarke SHHHAIR 30 Silent Air Compressor fig
22

A SELECTION FROM THE VAST RANGE OFClarke SHHHAIR 30 Silent Air Compressor
fig 23

PARTS & SERVICE:
0208 988 74000
Parts Enquiries
Parts@clarkeinternational.com
Servicing & Technical Enquiries
Service@clarkeinternational.com 

SALES: UK 01992 565333 or Export 00 44 (0)1992 565335
larrREINTERNATIONAL Hemnal Street, Epping, Essex CM16 4LG
www.clarkeinternational.comn 

Read User Manual Online (PDF format)

Loading......