ROHM BM2PDA1Y-Z Evaluation Board User Guide

June 5, 2024
ROHM

ROHM BM2PDA1Y-Z Evaluation Board

Please note that this document covers only the BM2PDA1Y-Z evaluation board (B M2PDA1Y-EVK-001) and its functions. For additional information, please refer to the datasheet.

To ensure safe operation, please carefully read all precautions before
handling the evaluation board

| Depending on the configuration of the board and voltages used,
Potentially lethal voltages may be generated.
Therefore, please make sure to read and observe all safety precautions described in the red box below.
---|---
**Before Use**

  1. Verify that the parts/components are not damaged or missing (i.e. due to the drops).

  2.  Check that there are no conductive foreign objects on the board.

  3. Be careful when performing soldering on the module and/or evaluation board to ensure that solder splash does not occur.

  4. Check that there is no condensation or water droplets on the circuit board.
    **During Use**

  5. ``Be careful to not allow conductive objects to come into contact with the board.

  6. Brief accidental contact or even bringing your hand close board may result in discharge and lead to severe injury or death.
    Therefore, DO NOT touch the board with your bare hands or bring them too close to the board.
    In addition, as mentioned above please exercise extreme caution when using conductive tools such as tweezers and screwdrivers.

  7.  If used under conditions beyond its rated voltage, it may cause defects such as short-circuit or, depending on the circumstances, explosion or other permanent damages.

  8. Be sure to wear insulated gloves when handling is required during operation.
    **After Use**

  9. ``The ROHM Evaluation Board contains the circuits which store the high voltage. Since it stores the charges even after the connected power circuits are cut, please discharge the electricity after using it, and please deal with it after confirming such electric discharge.

  10. Protect against electric shocks by wearing insulated gloves when handling.


This evaluation board is intended for use only in research and development facilities and should by handled only by qualified personnel familiar with all safety and operating procedures.
We recommend carrying out operation in a safe environment that includes the use of high voltage signage at all entrances, safety interlocks, and protective glasses.

**AC/DC Converter**

Non-Isolated Buck Convertor 24 V 8.4 W Output **BM2PDA1Y-Z

Evaluation Board**

**BM2PDA1Y-EVK-001**

Feature
  1. (Adjustable Output Voltage with External Resistor
  2. Frequency 65 kHz
  3. Internal Start up Circuit 730 V(peak)
  4. Internal Super Junction FET 730 V(peak) (Ron= 1.2 0)
  5. Internal Current Sense Resistor (Detection Current 0.93 A)
  6. Contributes to Low EMI by Internal Hopping Function

Specification

Table 1. Input Range

Parameter Min Typ Max Units Conditions
Input Voltage Range 90 230 264 Vac
Input Frequency Range 47 50 / 60 63 Hz
Operating Temperature -10 25 +65 °C

Table 2. Evaluation board specification

These are representative values and not a guarantee of the characteristics, unless stated otherwise use VIN = 230 Vac, IOUT = 0.35 A, Ta= 25 ° C.

Parameter Min Typ Max Units Conditions
Output Voltage 22.08 24.0 25.2 V
Output Maximum Power 8.4 W
Output Current Range (Note 1) 0 0.35 A
No Load Power Consumption 100 mW IOUT = 0 A
Efficiency 89 %
Output Ripple Voltage (Note 2) 100 mVpp

(Note 1) Adjust the operating time so that surface temperature of no component exceeds 105 ° C
(Note 2) Do not consider spike nois

Operation Procedure

  1. Operation equipment
    (1) AC power supply 90 Vac to 264 Vac, 15 W or more
    (2) Electronic Load capacity 0.35A
    (3) Multimeter

  2. Connection Instruments
    (1) Tum off each power supply and connect the measuring instrument as shown below.
    (2) Turn on the power supply setting between 90 Vac to 264 Vac
    (3) Tum on the electrical load setting between Oto 0.35 A.
    (4) Connect the multimeter directly to the output and check the voltage by sensing.

Circuit

VIN = 90 to 264 Vac, VOUT = 24 V

**BOM List

**

Item Specifications Parts name Manufacture
Capacitor Cl 12 µF, 450 V UCY2W120MP01TD
C2 12 µF, 450 V UCY2W120MP01TD NICHICON
C3 NON MOUNTED
C4 2.2 µF, 50 V UMK316B7225KL-T TAIYO YUDEN
cs 1000 pF, 100 V HMK107B7102KA-T TAIYO YUDEN
C6 1000 pF, 100 V HMK107B7102KA-T TAIYO YUDEN
cs NON MOUNTED
C9 NON MOUNTED
Cl0 NON MOUNTED
Cll NON MOUNTED
C12 470 µF, 35 V UPW1V471MPD NICHICON
Connector CNl B02P-NV
Diode Dl FRO, 3 A, 600 V RFN3BM6S
D2 FRO, 0.2 A, 600 V RFU02VSM6S ROHM
DBl 1 A, 800 V D1UBA80 SHINDENGEN
Fuse Fl 1.6 A, 300 V 36911600000-
IC ICl BM2PDA1Y-Z
Jumper Jl 0Q MCR18EZPJ000
Inductor Ll 390 µH RFS1317-394KL
L2 NON MOUNTED
L3 470 µH 7447462471- WURTH ELECTRONIK
PhotoCoup ler PCl NON MOUNTED
PCB PCBl PCB0178
Resistor Rl SHORT
R2 1.2 MQ MCR03EZPFX1204 ROHM
R3 1 MQ MCR03EZPFX1004 ROHM
R4 200 kQ MCR03EZPFX2003 ROHM
R6 10 kQ MCR18EZPJ103 ROHM
R7 NON MOUNTED
R9 NON MOUNTED
**Layout

**

**Size 70 mm x 30 mm


BM2Pxx1Y Overview**

Features
  • PWM Current Mode
  • Built-in Frequency Hopping Function
  • Burst Operation at Light Load
  • Built-in 730 V(peak) Starter Circuit
  • Built-in 730 V(peak) Super Junction MOSFET
  • VCC UVLO (Under Voltage Lockout)
  • VCC OVP (Over Voltage Protection)
  • Over Current Limiter Function per Cycle
  • Soft Start Function
  • Sleep Mode

Line Up

Model Name| Switching Frequency| Frequency Reduction| OCP

Current

---|---|---|---
BM2PAA1Y-Z| 65 kHz| 0| 1.76 A
BM2PAB1Y-Z| 25 kHz|
BM2PDA1Y-Z| 65 kHz| 0| ****

0.93 A

BM2PDB1Y-Z| 25 kHz| –

Key Specifications
  • Operating Power Supply Voltage Range
    VCC                         11.10 V to 26.00 V
    DRAIN                   730 V(peak) (Max)

  •  Operating Current (Normal): 650 μA (Typ)

  • Operating Current (Burst): 350 μA (Typ)

  •  Operating Current (Sleep): 65 μA (Typ)

  •  Switching Frequency: 25 kHz / 65 kHz (Typ)

  •  Operation Temperature: -40 °C to +105 °C

  •  MOSFET ON Resistance: 1.2 Ω (Typ)

Table 3. BM2Pxx1Y-Z Pin Description

No. Name I/O Function
1 N.C. Non connection
2 SLEEP I Sleep/Normal modes witching pin
3 GND_IC I/O GND pin
4 FB I Output voltage feedback pin
5 VCC I Input voltage pin
6 DRAIN I/O MOSFET drain pin
7 DRAIN I/O MOSFET drain pin
Application

Washing machine, Air conditioner, Other white goods

Package

W(Typ) x D(Typ) x H(Typ)
DIP7K                              9.27 mm x 6.35 mm x 8.63 mm
Pitch 2.54 mm

Measurement Data

Constant Load Regulations

Waveform





Waveform (Start Up)

Waveform (Load Response)


Waveform (Ripple Voltage)

Operation Temperature

Condition Iout=0.35 A. 20 min

Consider selecting parts after checking the temperature range of the parts used.

EMI

**



Revision History
**

Date Rev. Changes
Mar.2021 001 New Release
Nov. 2021 002 Max Output Power =10 W->8.4 W

Max Output Current =0.417 A->0.35 A
OCP Detection Current =1.0 A->  0.93
AFET Withstand voltage =650 V-> 730 V(peak)
Fiqure 8~30 modified

Notes

  1. The information contained herein is subject to change without notice.
  2. Before you use our Products, please contact our sales representative and verify the latest specifications :
  3. Although ROHM is continuously working to improve product reliability and quality, semiconductors can break down and malfunction due to various factors. Therefore, in order to prevent personal injury or fire arising from failure, please take safety measures such as complying with the derating characteristics, implementing redundant and fire prevention designs, and utilizing backups and fail-safe procedures. ROHM shall have no responsibility for any damages arising out of the use of our Poducts beyond the rating specified by ROHM.
  4. Examples of application circuits, circuit constants and any other information contained herein are provided only to illustrate the standard usage and operations of the Products. The peripheral conditions must be taken into account when designing circuits for mass production.
  5. The technical information specified herein is intended only to show the typical functions of and examples of application circuits for the Products. ROHM does not grant you, explicitly or implicitly, any license to use or exercise intellectual property or other rights held by ROHM or any other parties. ROHM shall have no responsibility whatsoever for any dispute arising out of the use of such technical information.
  6. The Products specified in this document are not designed to be radiation tolerant.
  7. For use of our Products in applications requiring a high degree of reliability (as exemplified below), please contact and consult with a ROHM representative : transportation equipment (i.e. cars, ships, trains), primary communication equipment, traffic lights, fire/crime prevention, safety equipment, medical systems, servers, solar cells, and power transmission systems.
  8. Do not use our Products in applications requiring extremely high reliability, such as aerospace equipment, nuclear power control systems, and submarine repeaters.
  9. ROHM shall have no responsibility for any damages or injury arising from non-compliance with the recommended usage conditions and specifications contained herein.
  10. ROHM has used reasonable care to ensurH the accuracy of the information contained in this document. However, ROHM does not warrants that such information is error-free, and ROHM shall have no responsibility for any damages arising from any inaccuracy or misprint of such information.
  11. Please use the Products in accordance with any applicable environmental laws and regulations, such as the RoHS Directive. For more details, including RoHS compatibility, please contact a ROHM sales office. ROHM shall have no responsibility for any damages or losses resulting non-compliance with any applicable laws or regulations.
  12. When providing our Products and technologies contained in this document to other countries, you must abide by the procedures and provisions stipulated in all applicable export laws and regulations, including without limitation the US Export Administration Regulations and the Foreign Exchange and Foreign Trade Act.
  13. This document, in part or in whole, may not be reprinted or reproduced without prior consent of ROHM.

Thank you for your accessing to ROHM product informations.
More detail product informations and catalogs are available, please contact us
ROHM Customer Support System http://www.rohm.com/contact/

[ **www.rohm.com**](http://www.rohm.com)

Documents / Resources

| ROHM BM2PDA1Y-Z Evaluation Board [pdf] User Guide
BM2PDA1Y-Z, Evaluation Board, BM2PDA1Y-Z Evaluation Board
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ROHM User Manuals

Related Manuals