REGENCY 600PHSPUMP Water Pump for Portable Sinks User Manual

June 5, 2024
Regency

REGENCY 600PHSPUMP Water Pump for Portable Sinks

REGENCY-600PHSPUMP-
Water-Pump-for-Portable-Sinks-PRODUCT

PERFORMANCE

Item #

|

HP

| GPH of Water @ Total Feet of Lift| Max. Lift
---|---|---|---
0 ft.| 10 ft.| 20 ft.| 30 ft.| 42 ft.
600PHSPUMP| 1/10| 320 GPH| 280 GPH| 190 GPH| 90 GPH| 0 GPH| 42 ft.

SAFETY INSTRUCTIONS

  1. Do not pump flammable or explosive liquids such as oil, gasoline, kerosene, ethanol, etc. Do not use in the presence of flammable or explosive vapors. Using this pump with or near flammable liquids can cause an explosion or fire, resulting in property damage, serious personal injury, and/or death.
  2. ALWAYS disconnect the power to the pump before servicing.
  3. Do not touch the motor housing during operation. The motor is designed to operate at high temperatures. Do not disassemble the motor housing.
  4. Do not handle the pump or pump motor with wet hands or when standing on a wet or damp surface, or in water before disconnecting the power.
  5. Release all pressure and drain all water from the system before servicing any component.
  6. Secure the discharge line before starting the pump. An unsecured discharge line will whip, possibly causing personal injury, and/or property damage.
  7. Extension cords may not deliver sufficient voltage to the pump motor. Extension cords present a life-threatening safety hazard if the insulation becomes damaged or the connection ends fall into water. The use of an extension cord to power this pump is not permitted.
  8. Wear safety goggles at all times when working with pumps.
  9. This unit is designed only for use on 115 volts (single-phase), 60 Hz, and is equipped with an approved 3 conductor cord and 3 prongs grounded plug. Do not remove the ground pin under any circumstances. The 3 prong plug must be directly inserted into a properly installed and grounded 3 prong, grounding-type receptacle. Do not use this pump with a 2 prong wall outlet. Replace the 2 prong outlet with a properly grounded 3 prong receptacle (a GFCI outlet) installed in accordance with the National Electrical Code and local codes and ordinances. All wiring should be performed by a qualified electrician.
  10. Protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking the cord. Do not use damaged or worn cords.
  11. Failure to comply with the instruction and designed operation of this unit may void the warranty. ATTEMPTING TO USE A DAMAGED PUMP can result in property damage, serious personal injury, and/or death.
  12. Ensure that the electrical circuit to the pump is protected by a 5 amp minimum (15 amp max.) fuse or circuit breaker.
  13. Do not lift the pump by the power cord.
  14. Know the pump and its applications, limitations, and potential hazards.
  15. Periodically inspect the pump and system components to ensure the pump suction screen is free of mud, sand, and debris. Disconnect the pump from the power supply before inspecting it.
  16. Follow all local electrical and safety codes, along with the National Electrical Code (NEC). In addition, all Occupational Safety and Health Administration (OSHA) guidelines must be followed.
  17. The motor of this pump has a thermal protector that will trip if the motor becomes too hot. The protector will reset itself once the motor cools down and an acceptable temperature has been reached. The pump may start Munexpectedly if it is plugged in.
  18. Ensure the electrical power source is adequate for the requirements of the pump.
  19. Before using the pump, check the hose for holes or excess wear, which could cause leaks, and ensure the hose is not kinked or making sharp angles. A straight hose allows the pump to move the greatest amount of water quickly, and also checks that all hose connections are tight to minimize leaks.
  20. This pump is made of high-strength, corrosion-resistant materials. It will provide trouble-free service for a long time when properly installed, maintained, and used. However, inadequate electrical power to the pump, dirt, or debris may cause the pump to fail. Please carefully read the manual and follow the instructions regarding common pump problems and remedies.

APPLICATION

  • This pump is designed for operating portable hand washing stations by transferring clean water from storage tanks to the sink faucet.

SPECIFICATIONS

POWER SUPPLY 115V • 60 Hz
LIQUID TEMP. RANGE 32- 95°F
DISCHARGE CONNECTION 3/4″ Garden Hose Thread Connection

½” NPT adaptor included   connecting   to your water heater or faucet

POWER CORD| SJTW, 18AWG/3C, 6 ft.

INSTALLATION

The pump must be installed in a stationary position with either:

  • A fixed pipeline
  • A flexible hose

NOTE: Do not allow the pump to hang suspended by the power cord, inlet pipe, or hose. The pump must be set on a stable surface or suspended from the handle. To ensure that the pump works properly, keep the intake area free from sludge and dirt of all kinds.

POWER SUPPLY

WARNING

  • To prevent death from electric shock, the pump must be connected only to a GFCI-protected outlet.
  • If the power cord or plug is damaged, do not use the pump. The power cord or plug may only be repaired by a certified electrician.
  1. The pump is equipped with a shock-proof plug according to regulations. The pump is designed to be connected to 120 VAC, 60 Hz GFCI protected socket.
  2. Make sure that the socket is sufficiently secured and is in excellent condition.

AREAS OF USE

  1. This pump is designed to pump clear water only.
  2. This pump should be used for transferring clean water within the portable hand washing station.

INSTALLATION INSTRUCTIONS

  1. Attach the hose to pump intake port. Attach the second hose to Pump discharge port.
  2. Position the Pump on solid surface so that both hoses are free from kinks.
  3. Place the unused end of intake hose in water to be transferred. Place unused end of discharge hose as needed to direct the water discharge at least 3 feet away from the source.

OPERATION

After reading these instructions, consider the following points before starting the pump:

  1. Verify that the discharge pipe is properly connected.
  2. Verify that the electrical connection is 120 VAC, 60 Hz.
  3. Verify that the electrical socket is GFCI protected and in good condition.
  4. Test GFCI-protected outlet before use.
  5. Verify that water and moisture cannot get near the power supply socket.
  6. Verify that the pump is installed so as to prevent running dry.
  7. Once plugged in, the pump will continue pumping until it is unplugged.

CARE & CLEANING

NOTE

  • Do not disassemble the motor housing. This motor has NO repairable internal parts, and disassembly may cause leakage or dangerous electrical wiring issues.
  • Do not lift up the pump by the power cord.REGENCY-600PHSPUMP-Water-Pump-for-Portable-Sinks-fig-1
Item Description Qty
1 Screw 4
2 Impeller Cover 1
3 Gasket 1
4 Impeller 1
5 Handle 1
6 Screw 2
7 Pump Body 1
8 Shaft 1
9 Motor 1

IF THE PUMP IS NOT RUNNING PROPERLY

  1. Remove the Impeller Cover Screws (1).
  2. Remove the Impeller Cover (2).
  3. Inspect the Gasket (3) and Impeller (4). If the Impeller wears out, replace it. The brushes could run up to 200 hours. If the brushes have been worn off, replace the Brush.
  4. The Brush must enter the square hole. Match the Brush curve to the armature curve.

TROUBLESHOOTING

Problem Possible Cause Corrective Action

The pump does not start or run.

| The fuse is blown| Replace the fuse
The breaker is tripped| Reset the breaker
The plug is disconnected| Secure the plug
The plug is corroded| Clean the plug prongs
The brushes are worn| Replace the brushes
The motor is overheated| Unplug from power and wait for 30 minutes, then plug power cord back in

The pump does not prime

|

The suction line is leaking air

| Repair the suction line by tightening hose connection or replacing hose washer if necessary
The impeller is clogged| Remove the blockage
The impeller is worn or damaged| Replace the impeller
The impeller is dry| Add water to the pump inlet

The flow rate is too low

| The hose is kinked or coiled| Straighten the hose
The strainer or hose is blocked| Clean the strainer or hose
The discharge hose is too long| Shorten the hose (50 ft. max.)
The impeller is worn| Replace the impeller

Documents / Resources

| REGENCY 600PHSPUMP Water Pump for Portable Sinks [pdf] User Manual
600PHSPUMP, Water Pump for Portable Sinks, Water Pump
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals