AVANTCO 178APPT71HC 2 Door Commercial Refrigerator User Manual
- June 5, 2024
- AVANTCO
Table of Contents
178APPT71HC 2 Door Commercial Refrigerator
User Manual
Refrigerated Pizza Prep Units
178APPT71HC, 178APPT49HC, 178APPT91HC
Refrigerated Sandwich Prep Units
178APT27HC, 178APT27MHC, 178APT48HC, 178APT48MHC, 178APT60HC, 178APT60MHC,
178APT71HC, 178APT71MHC
Please read the manual thoroughly prior to equipment set-up, operation and maintenance.
Warning
DANGER – RISK OF FIRE OR EXPLOSION. FLAMMABLE REFRIGERANT USED. TO BE REPAIRED ONLY BY TRAINED SERVICE PERSONNEL. DO NOT PUNCTURE REFRIGERANT TUBING.
CAUTION – RISK OF FIRE OR EXPLOSION. FLAMMABLE REFRIGERANT USED. CONSULT THE REPAIR MANUAL/OWNER’S GUIDE BEFORE ATTEMPTING TO SERVICE THIS PRODUCT. ALL SAFETY PRECAUTIONS MUST BE FOLLOWED.
CAUTION – RISK OF FIRE OR EXPLOSION DUE TO PUNCTURE OF REFRIGERANT TUBING; FOLLOW HANDLING INSTRUCTIONS CAREFULLY. FLAMMABLE REFRIGERANT USED.
CAUTION – RISK OF FIRE OR EXPLOSION DUE TO FLAMMABLE REFRIGERANT USED. FOLLOW HANDLING INSTRUCTIONS CAREFULLY IN COMPLIANCE WITH LOCAL GOVERNMENT REGULATIONS.
Installation
Important!!! Please Read Before Installation
- If the shelf has a raised lip, the lip needs to be installed facing up towards the rear of the cabinet to promote proper airflow. Failure to install the shelves properly is considered a user error and is not covered by a warranty.
- If the unit has recently been transported on its side, please let the unit stand still for a minimum of 24 hours before plugging it in.
- Make sure that the unit drops down to the desired temperature before loading the unit with the product.
- Make sure that there is proper ventilation around the unit in the area where it will operate.
- Make sure all accessories are installed (i.e.. Shelves, shelf clips, casters) before plugging the unit in.
- Please read through the manual in its entirety.
Cabinet Location Guidelines
-
Install the unit on strong and leveled surfaces
– Unit may be noisy and/or malfunction if the surface is uneven. -
Install the unit in an indoor, well-ventilated area
-For best performance, please maintain clearance of 4” on the back of the unit. Brackets should be attached to the back of the unit.
– Outdoor use may cause decreased efficiency and damage to the unit. -
Avoid installation in high humidity and/or dusty area
– Humidity could cause the unit to rust and decrease its efficiency of the unit.
– Dust collected on the condenser coil will cause the unit to malfunction.
– Malfunction due to a dirty condenser will void the warranty. -
Select a location away from heat and moisture-generating equipment
– High ambient temperatures will cause the compressor to overwork, leading to higher energy bills and the gradual breakdown of the unit.
-With the lid open, the unit should not be used in areas over 80 degrees. The unit should not be used in areas over 90 degrees.
-Malfunction due to high ambient temperature will void the warranty. -
For optimal performance, 3” of clearance is required around all louvered or vented panels, to allow for proper airflow
-For your convenience, a set of brackets is included to prevent this unit from being pushed up against a wall
-Component failure due to improper installation is not covered under warranty.
Electrical
- Please ensure that the required voltage of the compressor is being supplied at all times. Low or high voltage can detrimentally affect the refrigeration unit.
- All units should be plugged into a grounded and properly-sized electrical outlet with appropriate overcurrent protection. Please refer to the electrical requirements on the nameplate.
- Please make sure that your unit has its own dedicated outlet.
- Do not use an extension cord.
Temperature Controls
- Refrigerant LED – Compressor is on
- Fan LED – The fan is on
- Defrost LED – Defrost cycle is running
Functions
Adjusting the Temperature
Your new refrigerator or freezer is already factory-set to run at optimum temperatures for food safety and should require no adjustments.
Refrigerators are set to cycle between a minimum temperature of 33 degrees Fahrenheit and a maximum temperature of 40 degrees Fahrenheit.
Adjusting the temperature changes the minimum temperature your unit will run at. Your unit will not run constantly at this setting. To change it, follow these instructions:
Digital Control Units
- Hold “SET” for 1 sec. The display will flash the current minimum temperature.
- Use the arrow buttons to adjust the minimum temperature you want it to run at.
- Press “SET” again to save your settings
Always remember to calculate the differential if you change the minimum temperature setting. The cabinet temperature will fluctuate up to +7 degrees over your set minimum temperature as the compressor runs and shuts off. Setting the temperature too high will result in unsafe maximum temperatures.
Loading Product
Before loading shelves, please be sure that all shelf clips are completely
fastened in their correct locations. It is important that all shelves rest
completely level before stocking your cabinet with products.
In order to maintain correct air flow inside the unit, please be sure to leave
two to four (2 to 4) inches of space between the back wall and stored product.
Blocking the evaporator fans will result in a warmer cabinet temperature, and
ultimately compressor failure.
Running a Manual Defrost Cycle
This unit is pre-programmed to run automatic defrost cycles at preset
intervals. However, if you would like to run a manual defrost cycle at any
time, please follow the steps below:
Refrigerators: Press the defrost button (snowflake symbol and down arrow) for approximately 3 seconds. Repeat to stop the defrost cycle.
Defrost Systems
Refrigerator coils are kept below the freezing point (32° F). During
compressor downtime, the evaporator fan continues to circulate air through the
evaporator coil. This air circulation raises the coil temperature above the
freezing point, melting any accumulated frost. Run-off water is drained into
the evaporator pan and evaporated. Freezer coils are defrosted electrically.
Automatic defrost timers automatically initiate at pre-set intervals and for a
pre-determined duration.
Loading Food Pans
Pizza prep units and sandwich prep units are designed to function with all
pans in place, even if some pans are to be left empty. For maximum food
freshness, fill the pans only with an amount that can be used in a specific
usage period. During non-use, please close the insulated lid cover.
Safety / Warning
Please pay close attention to the safety notices in this section. Disregarding these notices may lead to serious injury and/or damage to the unit.
Attention
- To minimize shock and fire hazards, be sure not to overload the outlet. Please designate one outlet for your unit.
- Do not use extension cords.
- Do not put your hands under the unit while it is being moved.
- When the unit is not in use for a long period of time, please unplug the unit from the outlet.
- After unplugging the unit, wait at least 10 minutes before plugging it back in. Failure to do so could cause damage to the compressor.
Unplug Cord
- To minimize shock and fire hazards, please do not plug or unplug the cord with wet hands.
- During maintenance and cleaning, please unplug the unit.
Proper Grounding Required
- To minimize shock and fire hazards, make sure that the unit is properly grounded.
Warning
- Do not attempt to remove or repair any component unless instructed by the factory.
- Make sure that the unit is not resting on or against the electrical cord and plug.
- To minimize personal injury, do not hang on the doors.
- Do not store any flammable and explosive gas or liquids inside the unit.
- Do not attempt to alter or tamper with the electrical cord.
Food Pan Layouts:
Standard Top
Mega Top
Food Pan Divider Bars:
ITEM #| SIZE| APT27HC| APT48HC| APPT49HC|
APT6OHC| APPT71HC| APT-71-HC| APPT91HC
---|---|---|---|---|---|---|---|---
178SCLB15354| 13 15/16″ x
9/16″| 2| | | | | |
178SCLB15327| 12 7/s” X 9/16″| | 2| | 2| | 11|
178SCLB25354| 13 15/16″ x 1″| 3| | | | | |
178SCLB25327| 12 7/8″ x 1″| | 5| | 7| | |
178PICB15331| 13″ x 9/16″| | | | | 2| |
178PICB25331| 13″ x 1″| | | | | 8| |
178PICB15331| 13″ x 9/16″| | | 2| | | |
178PICB25331| 13″ x 1″| | | 5| | | |
178PICB15331| 13″ x 9/16″| | | | | | | 2
178PICB25331| 13″ x 1″| | | | | | | 11
Food Pan Divider Bars: A-
ITEM #| SIZE| APT-27-MHC| APT-48-MHC| APT-60-MHC|
APT-71-MHC
---|---|---|---|---|---
178SCLB15532| 20 15/16″ x 9/16″| 2| | |
178SCLB25532| 20 15/16″ x 1″| 3| 6| 8| 11
178SCLB90532| 20 15/16″ x 3 9/16″| | 1| |
178SCLB10853| 20 15/16″ x 4 1/4″| | | 1|
Regular Maintenance
WARNING: DISCONNECT THE POWER CORD BEFORE CLEANING ANY PARTS OF THE UNIT.
Cleaning The Condenser Coil
-
For efficient operation, it is important that the condenser surface be kept free of dust, dirt, and lint.
-
We recommend cleaning the condenser coil and fins at least once per month.
-
Clean with a commercial condenser coil cleaner, available from any kitchen equipment retailer.
Brush the condenser fins from top to bottom, not side to side. -
After cleaning, straighten any bent condenser fins with a fin comb.
Cleaning The Fan Blades and Motor
If necessary, clean the fan blades and motor with a soft cloth. If it is
necessary to wash the fan blades, cover the fan motor to prevent moisture
damage.
Cleaning The Interior of Unit
- When cleaning the cabinet interior, use a solvent of warm water and mild soap.
- Do not use steel wool, caustic soap, abrasive cleaners, or bleach that may damage the stainless steel surface.
- Wash door gaskets on a regular basis, preferably weekly. Simply remove the door gasket from the frame of the door, soak it in warm water and soap for thirty (30) minutes, dry with a soft cloth, and replace it.
- Check door gaskets for proper seals after they are replaced.
- Periodically remove the shelves and pilasters from the unit and clean them with mild soap and warm water. To remove the pilasters, first, remove the shelves and shelf brackets. Then, simply lift the pilaster up and out.
Troubleshooting
Compressor Not Running
The fuse has blown or the circuit breaker tripped.| Replace fuse or reset
circuit breaker.
---|---
The power cord is unplugged.| Plug in the power cord.
Thermostat was set too high.| Set the thermostat to a lower temperature.
Cabinet in defrosts cycle.| Wait for defrost cycle to finish.
Condensing Units Run For Long Periods of Time.
An excessive amount of warm product was placed in a cabinet.| Allow adequate
time for the product to cool down.
---|---
Prolonged door opening or door ajar.| Ensure doors are closed when not in use.
Avoid opening doors for long periods of time.
Door gasket(s) not sealing properly.| Ensure gaskets are snapped in
completely. Remove the gasket and wash with soap and water. Check the
condition of the gasket and replace it if necessary.
Dirty condenser coil.| Clean the condenser coil.
Evaporator coil iced over.| Unplug the unit and allow the coil to defrost.
Make sure the thermostat is not set too cold. Ensure that door gasket(s) are
sealing properly.
Cabinet Temperature is too warm.
The thermostat set is too warm.| Set the thermostat to lower the
temperature
---|---
Airflow blocked.| Re-arrange product to allow for proper airflow.
Make sure there is at least four inches of clearance
from evaporator.
An excessive amount of warm product is placed in a cabinet.| Allow adequate
time for the product to cool down.
The fuse has blown or the circuit breaker tripped.| Replace fuse or reset
circuit breaker.
Dirty condenser coil.| Clean the condenser coil.
Evaporator coil iced over.| Ensure doors are closed when not in use. Avoid
opening doors for long periods of time.